962 resultados para Extracting Absolute Roughness


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the cumulative effects of brushing (B) or immersion (I), using different cleansing agents, on the surface roughness, hardness and color stability of a heat-polymerized denture resin, Lucitone 550 (L), and a hard chairside reline resin, Tokuyama Rebase Fast II (T). Methods: A total of 316 specimens (10 x 2 mm) were fabricated. The specimens (n= 9) were divided into brushing or immersion groups according to the following agents: dentifrice/distilled water (D), 1% sodium hypochlorite (Na0C1), Corega Tabs (Pb), 1% chlorhexidine gluconate (Chx), and 0.2% peracetic acid (Ac). Brushing and immersion were tested independently. Assays were performed after 1, 3, 21, 45 and 90 blushing cycles or immersion of 10 seconds each. Data were evaluated statistically by repeated measures ANOVA. Tukey's honestly significant difference (HSD) post-hoc test was used to determine differences between means (a= 0.05). Results: For L there was no statistically significant difference in roughness, except a significant decrease in roughness by brushing with D. T showed a significant effect on the roughness after 90 immersions with Ac. Hardness values decreased for L when specimens were immersed or brushed in Na0C1 and Pb. The hardness of T decreased with increases in the repetitions (immersion or brushing), regardless of the cleaning method. Values of color stability for L resin showed significant color change after brushing with and immersion in Ac and Pb. Brushing with D exhibited a higher incidence of color change. For T there were no significant differences between cleaning agents and repetitions in immersion. A color change was noted after three brushings with the Ac, Chx, and D. Brushing with dentifrice decreased roughness of L. Immersion in or brushing with Na0C1 and Pb decreased the hardness of L. For T, hardness decreased with increases in immersions or brushing. Color changes after the immersion in or brushing with cleaning agents were clinically acceptable according to National Bureau of Standards parameters for both resins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aims at identifying the influence of soil surface roughness from small to large aggregates (random roughness) on runoff and soil loss and to investigate the interaction with soil surface seal formation. Bulk samples of a silty clay loam soil were sieved to four aggregate-size classes of 3 to 12, 12 to 20, 20 to 45, 45 to 100 mm, and packed in soil trays set at a 5% slope. Rainfall simulations using an oscillating nozzle simulator were conducted for 90 min at an average rainfall intensity of 50.2 mm h(-1). Soil surface roughness was measured using an instantaneous profile laser scanner and surface sealing was studied by macroscopic analysis of epoxy impregnated soil samples. The rainfall simulations revealed longer times to initiate runoff with increasing soil surface roughness. For random roughness levels up to 6 mm, a decrease in final runoff rate with increasing roughness was observed. This can be attributed to a decreased breakdown of the larger roughness elements on rougher surfaces, thus keeping infiltration rate high. For a random roughness larger than 6 mm, a greater final runoff rate was observed. This was caused by the creation of a thick depositional seal in the concentrated flow areas, thus lowering the infiltration rates. Analysis of impregnated soil sample blocks confirmed the formation of a structural surface seal on smooth surfaces, whereas thick depositional seals were visible in the depressional areas of rougher surfaces. Therefore, from our observations it can be learned that soil surface roughness as formed by the presence of different aggregate sizes reduces runoff but that its effect diminishes due to aggregate breakdown and the formation of thick depositional seals in the case of rough soil surfaces. Sediment concentration increased with increasing soil surface roughness, due to runoff concentration in flow paths. Nevertheless, final soil loss rates were comparable for all soil roughness categories, indicating that random roughness is only important in influencing runoff rates and the time to initiate runoff, but not in influencing sediment export through soil loss rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assuming that neutrinos are Majorana particles, in a three-generation framework, current and future neutrino oscillation experiments can determine six out of the nine parameters which fully describe the structure of the neutrino mass matrix. We try to clarify the interplay among the remaining parameters, the absolute neutrino mass scale and two CP violating Majorana phases, and how they can be accessed by future neutrinoless double beta (0vυββ) decay experiments, for the normal as well as for the inverted order of the neutrino mass spectrum. Assuming the oscillation parameters to be in the range presently allowed by atmospheric, solar, reactor, and accelerator neutrino experiments, we quantitatively estimate the bounds on m 0, the lightest neutrino mass, that can be inferred if the next generation 0υββ decay experiments can probe the effective Majorana mass (m ee) down to ∼1 meV. In this context we conclude that in the case that neutrinos are Majorana particles, (a) if m 0≳300 meV, i.e., within the range directly attainable by future laboratory experiments as well as astrophysical observations, then m ee≳30 meV must be observed, (b) if m 0 ≤ 300 meV, results from future 0υββ decay experiments combined with stringent bounds on the neutrino oscillation parameters, especially the solar ones, will place much stronger limits on the allowed values of m 0 than these direct experiments. For instance, if a positive signal is observed around m ee = 10 meV, we estimate 3≲m 0/meV≲65 at 95% C.L.; on the other hand, if no signal is observed down to m ee = 10 meV, then m 0≲55 meV at 95% C.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerous factors influencing the surface quality of wood after machining, among them we highlight the machining parameters and the properties of the wood. In the analysis of the influence of these factors on machining and in determining the quality measurement systems are used to obtain surface characteristics, these systems are divided into methods of contact and non-contact. The method for mechanical contact performed with the aid of the surface roughness tester is the most valued in the measurement of roughness of wood, however, aiming at a greater agility in these measurements, there is a need to seek alternatives for evaluation of surface quality, and one of these options is to use the forms of indirect measurements of this quality, as for example, the use of noise emission during the machining process. With this, the aim was to analyze the influence of the moisture content of the wood, at different levels, on surface quality of the species Pinus elliottii, determined by the method of mechanical probing move and relate this roughness with the sound emission issued for each class of humidity, during machining. The planning of experiments and statistical analyses were performed with the help of Taguchi method. The specimens were conditioned in greenhouses climatizadoras automatics for obtaining three classes of humidity. Machining tests of wooden pieces were performed on a machining center specific for this type of material. The roughness values were measured by a roughness verifier and the noise emission values were measured by for a measurer sound pressure level. Statistically significant differences were observed, the significance level of 10 %, on roughness and noise emission between the three levels of moisture. It was observed that with the increase in the moisture content occurred an increase of roughness and a reduction in noise emission. Monitoring of surface quality through noise level is an interesting alternative to the method of mechanical contact.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of mouth rinse solutions Lion color stability, surface roughness and microhardness of two composite resins. Material and Methods: Fifty test specimens of each composite (Filtek Z250 and Z350; 3M ESPE) were made using a teflon matrix (12x2 mm). Color, surface roughness and Knoop microhardness baseline measurements of each specimen were made and specimens (n=10) were immersed in 5 mouth rinse solutions: G1: distilled water (control), G2: Plax Classic, G3: Plax alcohol-free; G4: Periogard, and G5: Listerine. Final measurements of color, roughness and microhardness were performed and the results submitted to statistical analysis (2-way ANOVA, Bonferroni's test; p<0.05). Results: The most significant color change was observed for Z250 when immersed in Listerine (p<0.05). Z350 showed greater color change when immersed in Plax alcohol-free (p<0.05), but with no significant difference for Listerine (p>0.05). With regard to roughness, both composites showed significant changes when immersed in Listerine in comparison with Plax alcohol-free (p<0.05). Microhardness of Z350 was shown to be significantly changed when the composite was immersed in Plax alcohol-free (p<0.05). Conclusion: Composite changes depended on the material itself rather than the mouth rinse solution used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine the influence of mouthrinses on the surface roughness of a nanofilled composite resin after toothbrushing. One hundred nanofilled composite resin specimens were prepared and randomly distributed into two groups-brushed and non-brushed-and then assigned to five subgroups, according to the mouthrinse solutions (n = 10): Colgate Plax Fresh Mint, Oral B, Cepacol, Colgate Plax, and artificial saliva. Each sample was immersed in 20 mL of the mouthrinses for 1 minute, 5 days per week, twice a day, for a 3-week period. The control group used in the study was one in which the specimens were not subjected to brushing and remained only in artificial saliva. Toothbrushing was performed once a week for 1 minute, for 3 weeks. Surface roughness measurements (Ra) were performed after the immersion period and toothbrushing, by means of a profilometer. Data were analyzed by two-way ANOVA and Tukey's test. Analysis revealed that the association between toothbrushing and Colgate Plax Fresh Mint produced the lowest surface roughness (p < 0.05). All other groups tested (Oral B, Cepacol, Colgate Plax, artificial saliva) exhibited no statistically significant differences between surfaces, whether subjected to toothbrushing or not (p < 0.05). It was concluded that the surface roughness of the nanofilled composite resin tested can be influenced by the mouthrinse associated with toothbrushing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To investigate the effect of Si addition on a nanometer-scale roughness Ca and P implant surfaces in a canine tibia model by biomechanical and histomorphometric evaluations. Material and methods: The implant surfaces comprised a resorbable media CaP microblasted (control) and a CaP resorbable media + silica-boost microblasted (experimental) surfaces. Surfaces were characterized by scanning electron microscopy (SEM), X-ray photoelectron spectroscopy (XPS), and optical interferometry (IFM) down to the nanometric level. The animal model involved the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six dogs, remaining in vivo for 2 or 4 weeks. After euthanization, half of the specimens were torquedto- interface failure, and the other half was subjected to histomorphologic and bone-to-implant contact (BIC) evaluation. Torque and BIC statistical evaluation was performed by the Friedman test at 95% level of significance, and comparisons between groups was performed by the Dunn test. Results: IFM and SEM observations depicted comparable roughness parameters for both implant surfaces on the micrometer and nanometer scales. XPS analysis revealed similar chemical composition, except for the addition of Si on the experimental group. Torque-to-interface failure and BIC mean values showed no significant differences (P = 0.25 and 0.51, respectively) at both 2- and 4-week evaluation points for experimental and control groups. Early bone healing histomorphologic events were similar between groups. Conclusions: The experimental surface resulted in not significantly different biomechanical fixation and BIC relative to control. Both surfaces were biocompatible and osseoconductive.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Nanofilled composite resins are claimed to provide superior mechanical properties compared with microhybrid resins. Thus, the aim of this study was to compare nanofilled with microhybrid composite resins. The null hypothesis was that the size and the distribution of fillers do not influence the mechanical properties of surface roughness and wear after simulated toothbrushing test. Material and methods: Ten rectangular specimens (15 mm x 5 mm x 4 mm) of Filtek Z250 (FZ2), Admira (A), TPH3 (T), Esthet-X (EX), Estelite Sigma (ES), Concept Advanced (C), Grandio (G) and Filtek Z350 (F) were prepared according to manufacturer's instructions. Half of each top surface was protected with nail polish as control surface (not brushed) while the other half was assessed with five random readings using a roughness tester (Ra). Following, the specimens were abraded by simulated toothbrushing with soft toothbrushes and slurry comprised of 2: 1 water and dentifrice (w/w). 100,000 strokes were performed and the brushed surfaces were re-analyzed. Nail polish layers were removed from the specimens so that the roughness (Ra) and the wear could be assessed with three random readings (mu m). Data were analyzed by ANOVA and Tukey's multiple-comparison test (alpha = 0.05). Results: Overall outcomes indicated that composite resins showed a significant increase in roughness after simulated toothbrushing, except for Grandio, which presented a smoother surface. Generally, wear of nanofilled resins was significantly lower compared with microhybrid resins. Conclusions: As restorative materials suffer alterations under mechanical challenges, such as toothbrushing, the use of nanofilled materials seem to be more resistant than microhybrid composite resins, being less prone to be rougher and worn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The soil surface roughness increases water retention and infiltration, reduces the runoff volume and speed and influences soil losses by water erosion. Similarly to other parameters, soil roughness is affected by the tillage system and rainfall volume. Based on these assumptions, the main purpose of this study was to evaluate the effect of tillage treatments on soil surface roughness (RR) and tortuosity (T) and to investigate the relationship with soil and water losses in a series of simulated rainfall events. The field study was carried out at the experimental station of EMBRAPA Southeastern Cattle Research Center in Sao Carlos (Fazenda Canchim), in Sao Paulo State, Brazil. Experimental plots of 33 m(2) were treated with two tillage practices in three replications, consisting of: untilled (no-tillage) soil (NTS) and conventionally tilled (plowing plus double disking) soil (CTS). Three successive simulated rain tests were applied in 24 h intervals. The three tests consisted of a first rain of 30 mm/h, a second of 30 mm/h and a third rain of 70 mm/h. Immediately after tilling and each rain simulation test, the surface roughness was measured, using a laser profile meter. The tillage treatments induced significant changes in soil surface roughness and tortuosity, demonstrating the importance of the tillage system for the physical surface conditions, favoring water retention and infiltration in the soil. The increase in surface roughness by the tillage treatments was considerably greater than its reduction by rain action. The surface roughness and tortuosity had more influence on the soil volume lost by surface runoff than in the conventional treatment. Possibly, other variables influenced soil and water losses from the no-tillage treatments, e. g., soil type, declivity, slope length, among others not analyzed in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: This study compared the biomechanical fixation and bone-to-implant contact (BIC) of implants with different surfaces treatment (experimental resorbable blasting media-processed nanometer roughness scale surface, and control dual acid-etched) in a dog model. Material and methods: Surface characterization was made in six implants by means of scanning electron microscopic imaging, atomic force microscopy to evaluate roughness parameters, and X-ray photoelectron spectroscopy (XPS) for chemical assessment. The animal model comprised the bilateral placement of control (n = 24) and experimental surface (n = 24) implants along the proximal tibiae of six mongrel dogs, which remained in place for 2 or 4 weeks. Half of the specimens were biomechanically tested (torque), and the other half was subjected to histomorphologic/ morphometric evaluation. BIC and resistance to failure measures were each evaluated as a function of time and surface treatment in a mixed model ANOVA. Results: Surface texturing was significantly higher for the experimental compared with the control surface. The survey XPS spectra detected O, C, Al, and Ti at the control group, and Ca (similar to 0.2-0.9%) and P (similar to 1.7-4.1%) besides O, C, Al, and Ti at experimental surfaces. While no statistical difference in BIC was found between experimental and control surfaces or between 2 and 4 weeks in vivo, both longer time and use of experimental surface significantly increased resistance to failure. Conclusions: The experimental surface resulted in enhanced biomechanical fixation but comparable BIC relative to control, suggesting higher bone mechanical properties around the experimental implants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of beverages and brushing on the surface roughness(SR) and color change(Delta E) of a composite resin. For this, 120-disks(10 mmx2 mm) of composite resin(Filtek-Z250) were prepared and polished. Initials SR(Ra-mu m) and color(CIELab-system) were measured with rugosimeter and spectrophotometer; specimens were divided into four groups(red wine, soft drink, sugar cane spirit, or artificial saliva=control) and three subgroups(without brushing; brushed with Colgate or with Close-Up). Specimens were immersed in the beverage 5x/day, for 5', over 30 day, being two subgroups brushed(120 strokes/day). Color was measured at 15th day, 30th day and after repolishment; SR at 30th day. Delta E-values were statistically different after immersion in the beverages(p<0.05). Red wine promoted the highest alteration, followed by soft drink=sugar cane spirit and finally saliva. At 30th day, specimens exhibited Delta E higher than 15th day; after repolishing, Delta E was similar to 15th day. Beverages and brushing negatively influenced the SR. Therefore, Delta E and SR can be influenced by beverages and brushing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The absolute configuration and solution-state conformers of three peperomin-type secolignans isolated from Peperomia blanda (Piperaceae) are unambiguously determined by using vibrational circular dichroism (VCD) spectroscopy associated with density functional theory (DFT) calculations. Advantages of VCD over the electronic form of CD for the analysis of diastereomers are also discussed. This work extends our growing knowledge about secondary metabolites within the Piperaceae family species while providing a definitive and straightforward method to assess the absolute stereochemistry of secolignans.