920 resultados para Aortic Valve Stenosis
Resumo:
Pulse-wave velocity (PWV) is considered as the gold-standard method to assess arterial stiffness, an independent predictor of cardiovascular morbidity and mortality. Current available devices that measure PWV need to be operated by skilled medical staff, thus, reducing the potential use of PWV in the ambulatory setting. In this paper, we present a new technique allowing continuous, unsupervised measurements of pulse transit times (PTT) in central arteries by means of a chest sensor. This technique relies on measuring the propagation time of pressure pulses from their genesis in the left ventricle to their later arrival at the cutaneous vasculature on the sternum. Combined thoracic impedance cardiography and phonocardiography are used to detect the opening of the aortic valve, from which a pre-ejection period (PEP) value is estimated. Multichannel reflective photoplethysmography at the sternum is used to detect the distal pulse-arrival time (PAT). A PTT value is then calculated as PTT = PAT - PEP. After optimizing the parameters of the chest PTT calculation algorithm on a nine-subject cohort, a prospective validation study involving 31 normo- and hypertensive subjects was performed. 1/chest PTT correlated very well with the COMPLIOR carotid to femoral PWV (r = 0.88, p < 10 (-9)). Finally, an empirical method to map chest PTT values onto chest PWV values is explored.
Resumo:
After trans-catheter aortic valve implantation (TAVI), the need for postinterventional pacemaker (PM) implantation can occur in as many as 10-50% of cases, but it is not yet clear, how this need can be predicted. The aim of this study was to assess the possible predictive factors of post TAVI PM implantation based on Computed Tomography (CT) measured aortic valve calcification and its distribution.
Resumo:
The ATS 3f Enable® Bioprosthesis is a self-expanding valve with a tubular design that allows for decreased leaflet stress and preservation of aortic sinuses. We report the midterm results of a prospective, multicenter clinical study evaluating the safety and efficacy of this stented bioprosthesis in patients undergoing isolated aortic valve replacement with or without concomitant procedures.
Resumo:
BACKGROUND: The arterial switch operation (ASO) is currently the treatment of choice in neonates with transposition of the great arteries (TGA). The outcome in childhood is encouraging but only limited data for long-term outcome into adulthood exist. METHODS AND RESULTS: We studied 145 adult patients (age>16, median 25years) with ASO followed at our institution. Three patients died in adulthood (mortality 2.4/1000-patient-years). Most patients were asymptomatic and had normal left ventricular function. Coronary lesions requiring interventions were rare (3 patients) and in most patients related to previous surgery. There were no acute coronary syndromes. Aortic root dilatation was frequent (56% patients) but rarely significant (>45mm in 3 patients, maximal-diameter 49mm) and appeared not to be progressive. There were no acute aortic events and no patient required elective aortic root surgery. Progressive neo-aortic-valve dysfunction was not observed in our cohort and only 1 patient required neo-aortic-valve replacement. Many patients (42.1%), however, had significant residual lesions or required reintervention in adulthood. Right ventricular outflow tract lesions or dysfunction of the neo-pulmonary-valve were frequent and 8 patients (6%) required neo-pulmonary-valve replacement. Cardiac interventions during childhood (OR 3.0, 95% CI 1.7-5.4, P<0.0001) were strong predictors of outcome (cardiac intervention/significant residual lesion/death) in adulthood. CONCLUSIONS: Adult patients with previous ASO remain free of acute coronary or aortic complications and have low mortality. However, a large proportion of patients require re-interventions or present with significant right sided lesions. Life-long cardiac follow-up is, therefore, warranted. Periodic noninvasive surveillance for coronary complications appears to be safe in adult ASO patients.
Acute hyponatremia after cardioplegia by histidine-tryptophane-ketoglutarate - a retrospective study
Resumo:
Background Hyponatremia is the most common electrolyte disorder in hospitalized patients and is known to be associated with increased mortality. The administration of antegrade single-shot, up to two liters, histidine-tryptophane-ketoglutarate (HTK) solution for adequate electromechanical cardiac arrest and myocardial preservation during minimally invasive aortic valve replacement (MIAVR) is a standard procedure. We aimed to determine the impact of HTK infusion on electrolyte and acid–base balance. Methods In this retrospective analysis we reviewed data on patient characteristics, type of surgery, arterial blood gas analysis during surgery and intra-/postoperative laboratory results of patients receiving surgery for MIAVR at a large tertiary care university hospital. Results A total of 25 patients were included in the study. All patients were normonatremic at start of surgery. All patients developed hyponatremia after administration of HTK solution with a significant drop of serum sodium of 15 mmol/L (p < 0.01). Measured osmolality did not change during all times of surgery compared to start of surgery (p = 0.28 – p = 0.79), indicating isotonic hyponatremia. After administration of HTK solution pH fell significantly due to development of metabolic acidosis. Conclusions Acute hyponatremia during cardioplegia with HTK solution is isotonic and should probably not be corrected without presence of hypotonicity as confirmed by measurement of serum osmolality.
Resumo:
OBJECTIVE: Current pulsatile ventricular assist devices operate asynchronous with the left ventricle in fixed-rate or fill-to-empty modes because electrocardiogram-triggered modes have been abandoned. We hypothesize that varying the ejection delay in the synchronized mode yields more precise control of hemodynamics and left ventricular loading. This allows for a refined management that may be clinically beneficial. METHODS: Eight sheep received a Thoratec paracorporeal ventricular assist device (Thoratec Corp, Pleasanton, Calif) via ventriculo-aortic cannulation. Left ventricular pressure and volume, aortic pressure, pulmonary flow, pump chamber pressure, and pump inflow and outflow were recorded. The pump was driven by a clinical pneumatic drive unit (Medos Medizintechnik AG, Stolberg, Germany) synchronously with the native R-wave. The start of pump ejection was delayed between 0% and 100% of the cardiac period in 10% increments. For each of these delays, hemodynamic variables were compared with baseline data using paired t tests. RESULTS: The location of the minimum of stroke work was observed at a delay of 10% (soon after aortic valve opening), resulting in a median of 43% reduction in stroke work compared with baseline. Maximum stroke work occurred at a median delay of 70% with a median stroke work increase of 11% above baseline. Left ventricular volume unloading expressed by end-diastolic volume was most pronounced for copulsation (delay 0%). CONCLUSIONS: The timing of pump ejection in synchronized mode yields control over left ventricular energetics and can be a method to achieve gradual reloading of a recoverable left ventricle. The traditionally suggested counterpulsation is not optimal in ventriculo-aortic cannulation when maximum unloading is desired.
Resumo:
After 75 years of invasive and over 50 years of interventional cardiology, cardiac catheter-based procedures have become the most frequently used interventions of modern medicine. Patients undergoing a percutaneous coronary intervention (PCI) outnumber those with coronary artery bypass surgery by a factor of 2 to 4. The default approach to PCI is the implantation of a (drug-eluting) stent, in spite of the fact that it improves the results of balloon angioplasty only in about 25% of cases. The dominance of stenting over conservative therapy or balloon angioplasty on one hand and bypass surgery on the other hand is a flagrant example of how medical research is digested an applied in real life. Apart from electrophysiological interventions, closure ot the patent foramen ovale and percutaneous replacement of the aortic valve in the elderly have the potential of becoming daily routine procedures in catheterization laboratories around the world. Stem cell regeneration of vessels or heart muscle, on the other hand, may remain a dream never to come true.
Resumo:
OBJECTIVE: Assessment of postoperative quality of life in patients over 80 years after cardiac surgery including coronary artery bypass grafting (CABG), aortic valve replacement (AVR) and combined procedures. METHODS: Quality of life of n=136 patients over 80 years at operation (82.3+/-2.1 years), undergoing isolated CABG in 61 patients (45%), isolated AVR in 34 patients (25%) and a combination of CABG and AVR in 41 patients (30%) between January 1999 and December 2003 was reviewed. Preoperatively 66.2% presented in NYHA-class III/IV or CCS-class III/IV. Mean ejection fraction (EF) was 59.5%+/-14.0 (range 25-90%). Quality of life assessment was performed via a Seattle Angina Questionnaire. Follow-up was 100% complete for a total of 890 days (69-1853 days). RESULTS: Five-year survival was 70% for the CABG group, 75% for the AVR group and 65% for the CABG/AVR group. Quality of life was remarkable in all of the three groups after surgery. Overall 97 patients (81%) were not or little disabled in their daily activity. One hundred and twelve patients (93%) were free or considerably less symptomatic. Seventy-eight patients or 65% reported to be very satisfied with their current quality of life and 112 patients (93%) felt very reassured to have continuous full access to medical treatment despite of their advanced age. CONCLUSIONS: A remarkable quality of life and important improvement in the functional status after cardiac surgery in patients over 80 paired with a satisfactory medium-term survival justify early intervention for heart disease in this age group. Therefore, referral practice for patients over 80 years for heart surgery should be handled liberally.
Resumo:
Although platelets are a major factor in the pathogenesis of endocarditis, it is unclear if these cells promote or limit disease progression. To address this issue, the effects of thrombocytopenia on the early course of endovascular infection were examined. Aortic valve endocarditis was produced in rabbits by using Streptococcus sanguis M99. Thrombocytopenia was induced by intravenous administration of antiplatelet serum. Compared with controls (infected rabbits given nonimmune serum), thrombocytopenic rabbits had higher densities of streptococci within vegetations (mean log10 cfu/g, 9.78 vs. 8.11, P < .002) and a higher total number of bacteria per valve (mean log10 total cfu/valve, 8.96 vs. 7.43, P < .004). When tested for its interactions with platelets in vitro, strain M99 bound, activated, and aggregated rabbit platelets extensively and was rapidly killed by platelet microbicidal protein. These results indicate that platelets can limit disease progression in endocarditis. The host defense properties of platelets may in part be mediated by platelet microbicidal protein.
Resumo:
We describe the case of a 59-year-old man who had aortic regurgitation and a hypoplastic aortic valve and for whom an echocardiography evaluation revealed a vascular tumor in the roof of the left atrium, which was suspected to be a hemangioma. After undergoing preoperative invasive catheter coronary angiography, echocardiography, and multislice computed tomography examinations, the patient underwent an aortic miniroot replacement. Intraoperative findings confirmed the findings of the preoperative evaluations. The tumor, although macroscopically verified as a hemangioma, was not resected because of the tumor's position and size, and the threat of uncontrollable bleeding. After an uneventful postoperative clinical course, a subsequent successful transcatheter coil occlusion of the coronary fistula from the left circumflex coronary artery was performed as an alternative to surgical resection of the tumor. This case emphasizes the future role of a multimodality hybrid approach for diagnosis, planning (different 2- and 3-dimensional imaging modalities), and treatment in the form of combining interventional (transcatheter) and surgical (open heart) techniques, which could optimize different treatment strategies. This approach could be further improved by increasing the installations of hybrid operating rooms.
Resumo:
A 22-year-old man with pre-existing aortic valve disease contracted acute lactobacillus endocarditis six weeks after a dental procedure despite adequate prophylaxis. We discuss the limitations of prophylaxis for infective endocarditis in use until the end of 2008 and describe the new updated guidelines. We also explain the treatment of lactobacillus endocarditis and speculate on possible health risks of the increasing use of lactobacillus-containing dairy products, especially in immune-compromised patients.
Resumo:
OBJECTIVES Percutaneous closure of the transapical (TA) access site for large-calibre devices is an unsolved issue. We report the first experimental data on the TA PLUG device for true-percutaneous closure following large apical access for transcatheter aortic valve implantation. METHODS The TA PLUG, a self-sealing full-core closure device, was implanted in an acute animal study in six pigs (60.2 ± 0.7 kg). All the pigs received 100 IU/kg of heparin. The targeted activated clotting time was left to normalize spontaneously. After accessing the left ventricular apex with a 39 French introducer, the closure plug device was delivered with a 33 French over-the-wire system under fluoroscopic guidance into the apex. Time to full haemostasis as well as rate of bleeding was recorded. Self-anchoring properties were assessed by haemodynamic push stress under adrenalin challenge. An additional feasibility study was conducted in four pigs (58.4 ± 1.1 kg) with full surgical exposure of the apex, and assessed device anchoring by pull-force measurements with 0.5 Newton (N) increments. All the animals were electively sacrified. Post-mortem analysis of the heart was performed and the renal embolic index assessed. RESULTS Of six apical closure devices, five were correctly inserted and fully deployed at the first attempt. One became blocked in the delivery system and was placed successfully at the second attempt. In all the animals, complete haemostasis was immediate and no leak was recorded during the 5-h observation period. Neither leak nor any device dislodgement was observed under haemodynamic push stress with repeated left ventricular peak pressure of up to 220 mmHg. In the feasibility study assessing pull-stressing, device migration occurred at a force of 3.3 ± 0.5 N corresponding to 247.5 mmHg. Post-mortem analyses confirmed full expansion of all devices at the intended target. No macroscopic damage was identified at the surrounding myocardium. The renal embolic index was zero. CONCLUSIONS True-percutaneous left ventricular apex closure following large access is feasible with the self-sealing TA PLUG. The device allows for immediate haemostasis and a reliable anchoring in the acute animal setting. This is the first report of a true-percutaneous closure for large-calibre transcatheter aortic valve implantation access.
Resumo:
Over the past few decades, advances in ventricular assist device (VAD) technology have provided a promising therapeutic strategy to treat heart failure patients. Despite the improved performance and encouraging clinical outcomes of the new generation of VADs based on rotary blood pumps (RBPs), their physiologic and hematologic effects are controversial. Currently, clinically available RBPs run at constant speed, which results in limited control over cardiac workload and introduces blood flow with reduced pulsatility into the circulation. In this review, we first provide an update on the new challenges of mechanical circulatory support using rotary pumps including blood trauma, increased non-surgical bleeding rate, limited cardiac unloading, vascular malformations, end-organ function, and aortic valve insufficiency. Since the non-physiologic flow characteristic of these devices is one of the main subjects of scientific debate in the literature, we next emphasize the latest research regarding the development of a pulsatile RBP. Finally, we offer an outlook for future research in the field.
Resumo:
Systemic embolism is a classic complication of infective endocarditis. Coronary involvement and acute myocardial infarction (MI) are rare and increase mortality significantly. Recognising this unusual entity is crucial to provide adequate care. Percutaneous coronary intervention and thrombus aspiration is preferred to thrombolysis, which classically increases intracerebral hemorrhage risk. The present article describes the case of an acute inferior ST-elevated MI due to a Streptococcus salivarius endocarditis in a patient with known bicuspid aortic valve.
Resumo:
The cor triatriatum sinister is an uncommon congenital cardiac anomaly and reports in the literature are limited. It is often associated with other cardiac malformations, such as atrial septal defect, transposition of the great arteries, tetralogy of Fallot or atrioventricular septal defect. We present here a 6-year old boy who was diagnosed with cor triatriatum sinister, initially showing symptoms similar to mitral valve stenosis and congestive heart failure, and who underwent subsequent surgical correction using a left atrial approach. The fibromuscular membrane, separating the pulmonary veins from the mitral valve, was completely resected and postoperative echocardiography showed unobstructed pulmonary venous flow.