984 resultados para Amount of substance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the primary personality dimensions or traits that has consistently been linked to substance abuse is impulsivity. However, impulsivity is not a homogenous construct and although many of the measures of impulsivity are correlated, the most recent review of published factor analytic studies has proposed two independent dimensions of impulsivity: reward sensitivity, reflecting one of the primary dimension of J. A. Gray's personality theory, and rash impulsiveness. These two facets of impulsivity derived from the field of personality research parallel recent developments in the neurosciences where changes in the incentive value of rewarding substances has been linked to alterations in neural substrates involved in reward seeking and with a diminished capacity to inhibit behavior due to chronic drug exposure. In this paper, we propose a model that integrates the findings from research into individual differences with recent models of neural substrates implicated in the development of substance misuse. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims: The incidence of head and neck cancer (HNC) in Brazil has increased substantially in recent years. This increase is likely to be strongly associated with alcohol and tobacco consumption, but genetic susceptibility also should be investigated in this population. The aim of this study was to evaluate the association of polymorphisms in genes of alcohol metabolism enzymes and the risk of HNC. Methods: A hospital-based case-control study was conducted in Sao Paulo, Brazil. We here investigated ADH1C Ile(350)Val, ADH1B Arg(48)His, ADH1B Arg(370)Cys and CYP2E1*5A PstI polymorphisms by PCR-RFLP Polymerase Chain Reaction - Restriction Fragment Length Polymorphism in 207 histopathologically confirmed HNC cases (184 males and 23 females) and 244 cancer-free controls (225 males and 19 females) admitted as in-patients in the same hospital. Results: Chronic alcohol intake increased approximately four times the risk of HNC. The mutant genotype ADH1B Arg(48)His was more frequent in controls (12.7%) than HNC patients (5.8%) conferring protection for the disease (odds ratio (OR) = 0.42; 95% confidence interval (CI ), 0.21-0.85). Similar results were observed for individuals with ADH1B*2 (OR = 0.41; 95% CI , 0.20-0.82) or ADH1B*2/ADH1C*1 (OR = 0.32; 95% CI , 0.13-0.79) mutated haplotypes. Multiple regression analyses showed that individuals with the mutant genotype ADH1B Arg(48)His who consume alcohol > 30 g/L/day have more than four times the risk for HNC (OR = 4.42; 95% CI, 1.21-16.11). Conclusions: The fast alcohol metabolizing genotypes may prevent HNC when the amount of alcohol intake is < 30.655 g/L/day.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Substance-dependence is highly associated with executive cognitive function (ECF) impairments. However. considering that it is difficult to assess ECF clinically, the aim of the present study was to examine the feasibility of a brief neuropsychological tool (the Frontal Assessment Battery FAB) to detect specific ECF impairments in a sample of substance-dependent individuals (SDI). Sixty-two subjects participated in this study. Thirty DSM-IV-diagnosed SDI, after 2 weeks of abstinence, and 32 healthy individuals (control group) were evaluated with FAD and other ECF-related tasks: digits forward (DF), digits backward (DB), Stroop Color Word Test (SCWT), and Wisconsin Card Sorting Test (WCST). SDI did not differ from the control group on sociodemographic variables or IQ. However, SDI performed below the controls in OF, DB, and FAB. The SDI were cognitively impaired in 3 of the 6 cognitive domains assessed by the FAB: abstract reasoning, motor programming, and cognitive flexibility. The FAB correlated with DF, SCWT, and WCST. In addition, some neuropsychological measures were correlated with the amount of alcohol, cannabis, and cocaine use. In conclusion, SDI performed more poorly than the comparison group on the FAB and the FAB`s results were associated with other ECF-related tasks. The results suggested a negative impact of alcohol, cannabis, and cocaine use on the ECF. The FAB may be useful in assisting professionals as an instrument to screen for ECF-related deficits in SDI. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objective: Substance P may play a role in the pathogenesis of periodontal disease; however, its mechanisms of modulation are not clear. This study evaluated the effect of two concentrations of Substance P on the expression of matrix metalloproteinases (MMPs) and tissue inhibitors of metalloproteinases (TIMPs) in cultured human gingival fibroblasts. Materials and Methods: Fibroblasts were stimulated for 48 h with 10(-4) or 10(-9) m Substance P; untreated fibroblasts served as controls. The expression of MMP-1, -2, -3, -7 and -11 and of TIMP-1 and -2 was evaluated using real-time polymerase chain reaction and western blotting. Resulsts: There was a significant, concentration-dependent stimulatory effect of Substance P on MMP-1, -2, -3 and -7 and TIMP-2 gene expression (p < 0.05), and a probable effect on MMP-11 (p = 0.06). At the higher concentration (10(-4) m Substance P), MMP-1, -2, -3, -7 and -11 and TIMP-2 showed the greatest up-regulation; at the lower concentration (10(-9) (M) Substance P), MMP-1, -3 and -7 and TIMP-2 exhibited diminished up-regulation, with MMP-2 and -11 showing down-regulation (p < 0.05). Expression of TIMP-1 was not affected by Substance P (p > 0.05). Western blotting confirmed that Substance P up-regulated MMP-1, -2, -3 and -11 and TIMP-2. MMP-1, -3 and -11 and TIMP-2 showed greater up-regulation at the higher Substance P concentration and diminished up-regulation at the lower concentration. MMP-2 was up-regulated to a similar degree at both Substance P concentrations. Conclusion: In gingival fibroblast cells, Substance P at the higher concentration (10(-4) m) induced greater up-regulation of MMP-1, -3 and -11 and TIMP-2 expression, but at the lower concentration (10(-9) (M)) induced diminished up-regulation, which may represent a mechanism for modulating periodontal breakdown.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scientific evidence has shown an association between organochlorine compounds (OCC) exposure and human health hazards. Concerning this, OCC detection in human adipose samples has to be considered a public health priority. This study evaluated the efficacy of various solid-phase extraction (SPE) and cleanup methods for OCC determination in human adipose tissue. Octadecylsilyl endcapped (C18-E), benzenesulfonic acid modified silica cation exchanger (SA), poly (styrene-divinylbenzene (EN) and EN/RP18 SPE sorbents were evaluated. The relative sample cleanup provided by these SPE columns was evaluated using gas chromatography with electron capture detection (GC–ECD). The C18-E columns with strong homogenization were found to provide the most effective cleanup, removing the greatest amount of interfering substance, and simultaneously ensuring good analyte recoveries higher than 70%. Recoveries>70% with standard deviations (SD)<15% were obtained for all compounds under the selected conditions. Method detection limits were in the 0.003–0.009 mg/kg range. The positive samples were confirmed by gas chromatography coupled with tandem mass spectrometry (GC-MS/MS). The highest percentage found of the OCC in real samples corresponded to HCB, o,p′-DDT and methoxychlor, which were detected in 80 and 95% of samples analyzed respectively. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To analyze reliability of a self-applied questionnaire on substance use and misuse among adolescent students. METHODS: Two cross-sectional studies were carried out for the instrument test-retest. The sample comprised male and female students aged 1119 years from public and private schools (elementary, middle, and high school students) in the city of Salvador, Northeastern Brazil, in 2006. A total of 591 questionnaires were applied in the test and 467 in the retest. Descriptive statistics, the Kappa index, Cronbach's alpha and intraclass correlation were estimated. RESULTS: The prevalence of substance use/misuse was similar in both test and retest. Sociodemographic variables showed a "moderate" to "almost perfect" agreement for the Kappa index, and a "satisfactory" (>0.75) consistency for Cronbach's alpha and intraclass correlation. The age which psychoactive substances (tobacco, alcohol, and cannabis) were first used and chronological age were similar in both studies. Test-retest reliability was found to be a good indicator of students' age of initiation and their patterns of substance use. CONCLUSIONS: The questionnaire reliability was found to be satisfactory in the population studied.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We evaluated the immunogenicity of three recombinant hepatitis B vaccines, one Brazilian (Butang, Instituto Butantan) and two Korean vaccines (Euvax-B, LG Chemical Ltd. and Hepavax-Gene, Greencross Vaccine Corp.), administered intramuscularly to students aged 17 to 19 years in three 10-µg doses (corresponding to half the amount of antigen routinely used for adult vaccination) at intervals of one month between the first and second dose, and of four months between the second and third dose. A total of 316 students non-reactive for any serological marker of hepatitis B virus infection were vaccinated: 77 (24.4%) with the Butang vaccine, 71 (22.5%) with Euvax-B, 85 (26.9%) with Hepavax-Gene and, for comparison, 83 (26.2%) with Engerix-B (GlaxoSmithKline), whose efficacy in young adults at the dose used here has been confirmed in previous studies. Similar seroconversion rates (anti-HBs > 10 mIU/mL about one month after application of the third dose) were obtained for the Butang, Euvax-B, Hepavax-Gene and Engerix-B vaccines (96.2%, 98.6%, 96.5% and 97.6%, respectively). The frequency of good responders (anti-HBs > 100 mIU/mL) was also similar among students receiving the four vaccines (85.8%, 91.6%, 89.4% and 89.2%, respectively). The geometric mean titers (GMT) of anti-HBs about one month after the third dose obtained with these vaccines were 727.78 ± 6.46 mIU/mL, 2009.09 ± 7.16 mIU/mL, 1729.82 ± 8.85 mIU/mL and 2070.14 ± 11.69 mIU/mL, respectively. The GMT of anti-HBs induced by the Euvax-B and Engerix-B vaccines were higher than those obtained with the Butang vaccine (p < 0.05); this difference was not significant when comparing the other vaccines two-by-two. No spontaneous adverse effects attributable to the application of any dose of the four vaccines were reported.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Furosemide (FD: Lasix) is a loop diuretic which strongly increases both urine flow and electrolyte urinary excretion. Healthy volunteers were administered 40 mg orally (dissolved in water) and concentrations of FD were determined in serum and urine for up to 6 h for eight subjects, who absorbed water at a rate of 400 ml/h. Quantification was performed by HPLC with fluorescence detection (excitation at 233 nm, emission at 389 nm) with a limit of detection of 5 ng/ml for a 300-microliters sample. The elution of FD was completed within 4 min using a gradient of acetonitrile concentration rising from 30 to 50% in 0.08 M phosphoric acid. The delay to the peak serum concentration ranged from 60 to 120 min. FD was still easily measurable in the sera from all subjects 6 h after administration. In urine, the excretion rates reached their maximum between 1 and 3 h. The total amount of FD excreted in the urine averaged 11.2 mg (range 7.6-14.0 mg), with a mean urine volume of 3024 ml (range 2620-3596 ml). Moreover, the urine density was lower than 1.010 (recommended as an upper limit in doping analysis to screen diuretics) only for 2 h. An additional volunteer was administered 40 mg of FD and his urine was collected over a longer period. FD was still detectable 48 h after intake. Gas chromatography-mass spectrometry with different types of ionization was used to confirm the occurrence of FD after permethylation of the extract. Negative-ion chemical ionization, with ammonia as reactant gas, was found to be the most sensitive method of detection.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A dot enzyme linked immunosorbent assay (dot-ELISA) was previously developed to detect specific antibodies in rabbits sera immunized against FIA protein obtained from Yersina pestis. This antigen was covalently linked onto the surface of dacron (polyethyleneterephthalate). Here, standard conditions are described for the optimization of this procedure: an amount of 20 ng of FIA protein was fixed onto dacron; anti-rabbit IgG peroxidase conjugate diluted 1:8,000 and 30% non-fat instant milk as blocking substance were used throughout the method. This procedure was compared with that employing nitrocellulose as solid-phase which showed to be more sensitive. However, the method based on dacron did not show false positive reactions against non-immunized rabbits sera at low antigen amount and diluted anti-IgG peroxidase conjugate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Attention-deficit/hyperactivity disorder (ADHD), conduct disorder (CD), and oppositional defiant disorder (ODD) are common externalizing disorders of childhood. The common effects of these disorders on substance abuse need further investigation. The current study investigated the joint clusters of childhood/adolescence ADHD, CD, and ODD, and their influence on substance abuse/dependence in a population-based sample of adults. METHODS: The data were drawn from the PsyCoLaus study (n = 3,720) conducted in Lausanne, Switzerland. The population-based sample included 238 subjects meeting criteria for ADHD/ODD/CD diagnoses before the age of 15. Latent class analyses (LCA) were performed to derive comorbidity subtypes, which were subsequently characterized with respect to psychosocial correlates and substance use. RESULTS: The best fit in LCAs was achieved with three latent classes: an ADHD subtype (35.7 %); an externalizing multimorbid subtype (33.6 %) involving ODD, ADHD, and CD; and a third subtype with CD (30.7 %). The CD subtype showed the highest association with substance use. Apart from this, the externalizing multimorbid subtype was also significantly linked to substance use. The ADHD subtype had only elevated frequencies for alcohol dependence in comparison with subjects that had no history of ADHD, ODD, and CD during childhood or adolescence. Finally, important interactions between subtypes and sex were observed with regard to substance use. CONCLUSIONS: This study provides evidence showing that subtyping the externalizing disorders, ADHD, ODD and CD, along their comorbidity patterns leads to important differences regarding substance use. This could have implications for the etiology, prevention, and treatment of substance use disorders.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and transcultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This article aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The hydrogen isotope ratio (HIR) of body water and, therefore, of all endogenously synthesized compounds in humans, is mainly affected by the HIR of ingested drinking water. As a consequence, the entire organism and all of its synthesized substrates will reflect alterations in the isotope ratio of drinking water, which depends on the duration of exposure. To investigate the effect of this change on endogenous urinary steroids relevant to doping-control analysis the hydrogen isotope composition of potable water was suddenly enriched from -50 to 200 0/00 and maintained at this level for two weeks for two individuals. The steroids under investigation were 5β-pregnane-3α,20α-diol, 5α-androst-16-en-3α-ol, 3α-hydroxy-5α-androstan-17-one (ANDRO), 3α-hydroxy-5β-androstan-17-one (ETIO), 5α-androstane-3α,17β-diol, and 5β-androstane-3α,17β-diol (excreted as glucuronides) and ETIO, ANDRO and 3β-hydroxyandrost-5-en-17-one (excreted as sulfates). The HIR of body water was estimated by determination of the HIR of total native urine, to trace the induced changes. The hydrogen in steroids is partly derived from the total amount of body water and cholesterol-enrichment could be calculated by use of these data. Although the sum of changes in the isotopic composition of body water was 150 0/00, shifts of approximately 30 0/00 were observed for urinary steroids. Parallel enrichment in their HIR was observed for most of the steroids, and none of the differences between the HIR of individual steroids was elevated beyond recently established thresholds. This finding is important to sports drug testing because it supports the intended use of this novel and complementary methodology even in cases where athletes have drunk water of different HIR, a plausible and, presumably, inevitable scenario while traveling.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective Biomonitoring of solvents using the unchanged substance in urine as exposure indicator is still relatively scarce due to some discrepancies between the results reported in the literature. Based on the assessment of toluene exposure, the aim of this work was to evaluate the effects of some steps likely to bias the results and to measure urinary toluene both in volunteers experimentally exposed and in workers of rotogravure factories. Methods Static headspace was used for toluene analysis. o-Cresol was also measured for comparison. Urine collection, storage and conservation conditions were studied to evaluate possible loss or contamination of toluene in controlled situations applied to six volunteers in an exposure chamber according to four scenarios with exposure at stable levels from 10 to 50 ppm. Kinetics of elimination of toluene were determined over 24 h. A field study was then carried out in a total of 29 workers from two rotogravure printing facilities. Results Potential contamination during urine collection in the field is confirmed to be a real problem but technical precautions for sampling, storage and analysis can be easily followed to control the situation. In the volunteers at rest, urinary toluene showed a rapid increase after 2 h with a steady level after about 3 h. At 47.1 ppm the mean cumulated excretion was about 0.005% of the amount of the toluene ventilated. Correlation between the toluene levels in air and in end of exposure urinary sample was excellent (r = 0.965). In the field study, the median personal exposure to toluene was 32 ppm (range 3.6-148). According to the correlations between environmental and biological monitoring data, the post-shift urinary toluene (r = 0.921) and o-cresol (r = 0.873) concentrations were, respectively, 75.6 mu g/l and 0.76 mg/g creatinine for 50 ppm toluene personal exposure. The corresponding urinary toluene concentration before the next shift was 11 mu g/l (r = 0.883). Conclusion Urinary toluene was shown once more time a very interesting surrogate to o-cresol and could be recommended as a biomarker of choice for solvent exposure. [Authors]

Relevância:

100.00% 100.00%

Publicador:

Resumo:

During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and trans-cultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This paper aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromatographic separation of highly polar basic drugs with ideal ionspray mass spectrometry volatile mobile phases is a difficult challenge. A new quantification procedure was developed using hydrophilic interaction chromatography-mass spectrometry with turbo-ionspray ionization in the positive mode. After addition of deuterated internal standards and simple clean-up liquid extraction, the dried extracts were reconstituted in 500 microL pure acetonitrile and 5 microL was directly injected onto a Waters Atlantis HILIC 150- x 2.1-mm, 3-microm column. Chromatographic separations of cocaine, seven metabolites, and anhydroecgonine were obtained by linear gradient-elution with decreasing high concentrations of acetonitrile (80-56% in 18 min). This high proportion of organic solvent makes it easier to be coupled with MS. The eluent was buffered with 2 mM ammonium acetate at pH 4.5. Except for m-hydroxy-benzoylecgonine, the within-day and between-day precisions at 20, 100, and 500 ng/mL were below 7 and 19.1%, respectively. Accuracy was also below +/- 13.5% at all tested concentrations. The limit of quantification was 5 ng/mL (%Diff < 16.1, %RSD < 4.3) and the limit of detection below 0.5 ng/mL. This method was successfully applied to a fatal overdose. In Switzerland, cocaine abuse has dramatically increased in the last few years. A 45-year-old man, a known HIV-positive drug user, was found dead at home. According to relatives, cocaine was self-injected about 10 times during the evening before death. A low amount of cocaine (0.45 mg) was detected in the bloody fluid taken from a syringe discovered near the corpse. Besides injection marks, no significant lesions were detected during the forensic autopsy. Toxicological investigations showed high cocaine concentrations in all body fluids and tissues. The peripheral blood concentrations of cocaine, benzoylecgonine, and methylecgonine were 5.0, 10.4, and 4.1 mg/L, respectively. The brain concentrations of cocaine, benzoylecgonine, and methylecgonine were 21.2, 3.8, and 3.3 mg/kg, respectively. The highest concentrations of norcocaine (about 1 mg/L) were measured in bile and urine. Very high levels of cocaine were determined in hair (160 ng/mg), indicating chronic cocaine use. A low concentration of anhydroecgonine methylester was also found in urine (0.65 mg/L) suggesting recent cocaine inhalation. Therapeutic blood concentrations of fluoxetine (0.15 mg/L) and buprenorphine (0.1 microg/L) were also discovered. A relatively high concentration of Delta(9)-THC was measured both in peripheral blood (8.2 microg/L) and brain cortex (13.5 microg/kg), suggesting that the victim was under the influence of cannabis at the time of death. In addition, fluoxetine might have enhanced the toxic effects of cocaine because of its weak pro-arrhythmogenic properties. Likewise, combination of cannabinoids and cocaine might have increase detrimental cardiovascular effects. Altogether, these results indicate a lethal cocaine overdose with a minor contribution of fluoxetine and cannabinoids.