636 resultados para urethral stent


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Best percutaneous treatment strategy for lesions in coronary bifurcations is an ongoing subject of debate. There is limited data that analyses the effect of the different bifurcation strategies on coronary flow. Our aim is to evaluate the influence of different bifurcation stenting strategies on hemodynamic parameters, both in the main vessel (MV) and side branch (SB).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple analytical expression has been derived to calculate the characteristics of a wave that reflects at a stent implanted in a uniform vessel. The stent is characterized by its length and the wave velocity in the stented region. The reflected wave is proportional to the time derivative of the incident wave. The reflection coefficient is a small quantity of the order of the length of the stent divided by the wavelength of the unstented vessel. The results obtained coincide with those obtained numerically by Charonko et al. The main simplifications used are small amplitude of the waves so that equations can be linearized and that the length of the stent is small enough so that the values of the wave functions are nearly uniform along the stent. Both assumptions hold in typical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Los avances en la era endovascular han causado una revolución en el abordaje de la estenosis carotidea. La irrupción del abordaje transfemoral y transcervical ha hecho que la comunidad científica nos replanteemos las indicaciones terapeúticas en pacientes con estenosis carotidea sintomática o asintomática. Aunque los resultados del abordaje transfemoral mejoraron con la introducción de los sistemas de neuroprotección, un abundante número de estudios randomizados han sido dirigidos para comparar stent transfemoral frente a la endarterectomia. Endarterectomia frente a angioplastia en pacientes con estenosis severa sintomatica(EVA-3S), angioplastia con stent y neuroprotección frente a endarterectomia (SPACE), Angioplastia carotidea y vertebral (CAVATAS), revascularización carotidea mediante stent versus endarterectomia (CREST) estudio internacional carotideo (ICSS) todos fallaron en demostrar una ventaja global del stent transfemoral frente a la endarterectomia. El abordaje transcervical surge por tanto como opción segura de tratamiento, con buenos resultados clínicos iniciales, eliminando así algunas de las complicaciones del acceso transfemoral. Existe hasta la fecha una falta de estudios comparativos de morbimortalidad entre las tres opciones terapeúticas. Además, dado el elevado número de pacientes candidatos a ellos, es necesario una análisis de resultados y supervivencia de los mismos, asi como un análisis de costes relativos y coste-efectividad que podría tener importantes implicaciones en las políticas de salud y en las guias de tratamiento...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation presents dynamic flow experiments with fluorescently labeled platelets to allow for spatial observation of wall attachment in inter-strut spacings, to investigate their relationship to flow patterns. Human blood with fluorescently labeled platelets was circulated through an in vitro system that produced physiologic pulsatile flow in (1) a parallel plate blow chamber that contained two-dimensional (2D) stents that feature completely recirculating flow, partially recirculating flow, and completely reattached flow, and (2) a three-dimensional (3D) cylindrical tube that contained stents of various geometric designs. ^ Flow detachment and reattachment points exhibited very low platelet deposition. Platelet deposition was very low in the recirculation regions in the 3D stents unlike the 2D stents. Deposition distal to a strut was always high in 2D and 3D stents. Spirally recirculating regions were found in 3D unlike in 2D stents, where the deposition was higher than at well-separated regions of recirculation. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We are interested in the emergence of new markets. While the literature contains various perspectives on how such new markets come to be, the dynamics of the marketization process are less clear. This paper focuses on the development of stent technology and examines the activities characteristic of its emerging market. We identify four market ‘moments’: a mutable marketing moment prior to the point of disruption; two parallel moments at the point of disruption – internecine marketing between emergent competitors, and subversive marketing between those competitors and established actors; and finally, a civilized marketing moment. We conclude that emergent competitors operate two distinct strategies at the point of disruption. Also, legal activities are central to marketization dynamics during this period. In terms of process, while creative destruction may broadly describe the move from disruption to acceptance, there is a period of creative construction prior to disruption, when the new market is coming into being.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. Carotid artery stenting (CAS) is the treatment of choice for recurrent stenosis after carotid endarterectomy (CEA). However a significative incidence of in-stent restenosis could be occurred. Despite classical CEA leads to good results, in selective cases bypass graft may be the best treatment of in-stent restenosis. Case reports. We describe two cases of carotid bypass graft performed to treat a recurrent in-stent stenosis after CAS for post-CEA restenosis. No death and cardiac complication occurred and no cranial nerves impairment was detected. Conclusion. Prosthetic bypass graft is safe and effective in treatment of in-stent recurrent restenosis after CEA restenosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary heart disease is a major cause of morbidity and mortality worldwide. Percutaneous coronary intervention (PCI) has become the most widely used method of coronary artery revascularisation. The use of stents to hold open atherosclerosis induced arterial narrowing has significantly reduced elastic recoil and acute vessel occlusion following balloon angioplasty. However, bare metal stents have been associated with in-stent restenosis attributed to vascular smooth muscle cell (VSMC) hyperplasia and excessive neointimal formation. The resultant luminal renarrowing may manifest clinically with the return of symptoms such as chest pain or shortness of breath. The development of drug eluting stents has significantly reduced the incidence of in-stent restenosis (ISR). Unfortunately the antiproliferative medications used not only inhibit VSMC proliferation but also re-endothelialisation of the stented vessel. In addition, the drug impregnated polymer coating has been associated with a chronic inflammatory response within the vessel wall predisposing patients to stent thrombosis. Thus the identification of novel therapies which promote vessel healing without excessive proliferative or inflammatory response may improve long term outcome and reduce the need for repeated revascularisation. MicroRNAs (miRs) are short (18-25 nucleotide) non-coding RNAs acting to regulate gene expression. By binding to the 3’untranslated region of mRNA they act to fine tune gene expression either by mRNA degradation or translational repression. Originally identified in coordinating tissue development microRNAs have also been shown to play important roles coordinating the inflammatory response and in numerous cardiovascular diseases. MiR-21 has been identified in human atherosclerotic plaques, arteriosclerosis obliterans and abdominal aortic aneurysms. In addition, its up regulation has been documented in preclinical models of vascular injury. This study sought to identify the role of miR-21 in the development of ISR. Utilising a small animal model of stenting and in vitro techniques, we sought to investigate its influence upon VSMC and immune cell response following stenting. 19 The refinement of a murine stenting model within the Baker laboratory and the electrochemical dissolution of the metal stent from within harvested vascular tissues significantly improved the ability to perform detailed histological analysis. In addition, identification of miRNAs using in situ hybridisation was achieved for the first time within stented tissue. Neointimal formation and ISR was significantly reduced in mice in which miR-21 had been genetically deleted. In addition, neointimal composition was found to be altered in miR-21 KO mice with reductions in VSMC and elastin content demonstrated. Importantly, no difference in re-endothelialisation was observed. In vitro analysis demonstrated that VSMCs from miR-21 KO mice had both reduced proliferative and migratory capacity following platelet derived growth factor stimulation. Molecular analysis revealed that these differences may, at least in part, be due to de-repression of programmed cell death 4 (PDCD4). PDCD4 is a known miR-21 target within VSMCs implicated in the suppression of proliferation and promotion of apoptosis. Unfortunately, initial attempts at antimiR mediated knockdown of miR-21 in vivo, failed to produce a similar change in the suppression of ISR. Furthermore, a significant alteration in macrophage polarisation state within the neointima of miR-21 WT and KO mice was noted. Immunohistochemical staining revealed a preponderance of anti-inflammatory M2 macrophages in KO mice. Analysis of bone marrow derived macrophages from miR-21 KO mice demonstrated an increased level of the peroxisome proliferation activating receptor-γ (PPARγ) which facilitates M2 polarisation. Importantly, significant alterations in numerous pro-inflammatory cytokines, which also have mitogenic effects, were also found following genetic deletion of miR-21. In Summary, this is the first study to look at miRs in the development of ISR. MiR-21 plays an important role in the development of ISR by influencing the proliferative response of VSMCs and modulating the immune response following stent deployment. Further attempts to modulate miR-21 expression following PCI may reduce ISR and the need for repeat revascularisation while also reducing the risk of stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Hypospadias is one of the most common congenital genital anomalies in males that necessitates to be operated early in infancy (when 6 to 9 months old). On the other hand, hypospadias is a challenging field of pediatric urology with multiple reconstruction techniques. A perfect hypospadias repair is supposed to return urethral continuity with sufficient caliber, eradicate phallus curvature, and supply an acceptable appearance with low complications. Objectives: This study aimed to evaluate the outcomes of using onlay island flap technique in the repair of hypospadias with shallow urethral plate. Patients and Methods: In this prospective study within June 2012 to December 2013, we performed onlay island flap procedure to repair hypospadias with shallow urethral plate measuring less than 6 millimeter. This technique was selected for all types of hypospadiasis except subcoronal type. Nesbit’s dorsal plication procedure was established for chordee. In cases with very small glans, urethroplasty was performed without glansplasty. Results: Twenty three patients with mean age of 30 (range 10 - 60) months underwent onlay island flap repair; all had a shallow urethral plate < 6 mm, 3 had a very small glans, and 18 had chordee. Meatus was located in distal shaft in 5 cases, mid shaft in 8, proximal in 6 and penoscrotal type in 4 patients. Chordee was corrected with Nesbit’s dorsal plication in 16 cases. Complications were: meatal stenosis in 2 cases and urethrocutaneous fistula in 2 patients, all of which were repaired surgically. Mean follow up time was 13 (3 - 20) months. All cases that had glansplasty have excellent esthetic appearance. Conclusions: This technique offers acceptable results regarding meatal stenosis, urethrocutaneous fistula and esthetic outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Urethral duplication (UD) is a rare congenital anomaly with multiple anatomical variants. Case Presentation: In this article we present a four year-old child with complete UD. The patient was admitted for hypospadias repair, in evaluation we found type IIA1 UD according to Effmann classification. Patient underwent hypospadias repair saving complete UD. Conclusions: After one year follow-up he has normal and continent urination.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischemic stroke is a major public health problem worldwide, considered as the third most costly health condition in developed countries, with urgent reperfusion remaining the paramount goal for its treatment. In line with the results of recent randomized control trials, the introduction of stent retrievers was a major advancement in the treatment of stroke; however, interventionalists sometimes encounter thrombi not-retrievable by applying conventional techniques. In this article, we present a case treated by an innovative double-stent retrieval in Y-configuration that may potentially help other clinicians in similar situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Vascular implants have always been a key area of research in medical textiles. Knitted structures have been proven to be suitable for stent applications on the basis of their looped mesh geometry, structural flexibility and ease of manufacturing. However, there are biomechanical constraints of plain knit constructions that can result in clinical complications after implantation and hence cannot be ignored. This study reports a new segmented knit design inspired by structural metamerism observed in the body design of some invertebrate animals. Metamerism is the phenomenon of having a linear series of body segments fundamentally similar in structure, but assigned to perform different functions. It was hypothesized that utilization of this simple and yet effective biological design approach in stent construction could improve the degree of control for optimizing stent biomechanical properties. The proposed segmented stent was constructed by incorporating an elastic filament component into a polyethylene terephthalate knitted stent at specific intervals along its length, also known as the ‘Plating Technique’. This technique generates a structure with alternately arranged stiff and elastic knitted sections which equip the stent with vital structural support and volumetric compliance properties, respectively. The stent design parameters (filament diameter, loop length, segmentation plan) were optimized to achieve significantly better biomechanical performance (bending flexibility, compression resistance, volumetric expansion, longitudinal extensibility) than a plain knit stent.