900 resultados para the scanning reference electrode technique


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Solid oxide fuel cell (SOFC) technology has the potential to be a significant player in our future energy technology repertoire based on its ability to convert chemical energy into electrical energy. Infiltrated SOFCs, in particular, have demonstrated improved performance and at lower cost than traditional SOFCs. An infiltrated electrode comprises porous ceramic scaffolding (typically constructed from the oxygen ion conducting material) that is infiltrated with electron conducting and catalytic particles. Two important SOFC electrode properties are effective conductivity and three phase boundary density (TPB). Researchers study these electrode properties separately, and fail to recognize them as competing properties. This thesis aims to (1) develop a method to model the TPB density and use it to determine the effect of porosity, scaffolding particle size, and pore former size on TPB density as well as to (2) compare the effect of porosity, scaffolding particle size, and pore former size on TPB density and effective conductivity to determine a desired set of parameters for infiltrated SOFC electrode performance. A computational model was used to study the effect of microstructure parameters on the effective conductivity and TPB density of the infiltrated SOFC electrode. From this study, effective conductivity and TPB density are determined to be competing properties of SOFC electrodes. Increased porosity, scaffolding particle size, and pore former particle size increase the effective conductivity for a given infiltrate loading above percolation threshold. Increased scaffolding particle size and pore former size ratio, however, decreases the TPB density. The maximum TPB density is achievable between porosities of 45% and 60%. The effect of microstructure parameters are more prominent at low loading with scaffolding particle size being the most significant factor and pore former size ratio being the least significant factor.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES: To demonstrate the safety and feasibility of a new concept for CTO recanalization using a controlled antegrade and retrograde subintimal tracking technique (CART technique). BACKGROUND: A successful percutaneous recanalization of chronic coronary occlusions results in improved survival, as well as enhanced left ventricular function, reduction in angina, and improved exercise tolerance. However, successful recanalization of CTOs is still not optimal, and needs further improvements. METHODS: Ten patients with a CTO underwent the CART procedure. This technique combines the simultaneous use of the antegrade and retrograde approaches. A subintimal dissection is created antegradely and retrogradely, which allows the operator to limit the extension of the subintimal dissection in the CTO portion. A retrograde approach means that the occlusion site is approached in a retrograde fashion through the best collateral channel from any other patent coronary artery. RESULTS: The occlusion site was located in the RCA in 9 patients, and in the LAD in 1 patient. CTO duration varied from 7 to 84 months. Vessel recanalization was achieved in all patients. In all cases, the subintimal dissection was limited to the CTO region. No complications occurred in the collateral channel used for the retrograde approach. There were no in-hospital major adverse cardiac events. CONCLUSIONS: The CART technique is feasible, safe, and has a high success rate.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radiography is part of evaluating horses with poor performance and pelvic limb lameness; however, the radiographic appearance of the sacroiliac region is poorly described. The goal of the present study was to describe the use of a simple technique to obtain radiographs of the sacroiliac region in the anesthetized horse and to describe the radiographic appearance of this region. Seventy-nine horses underwent radiography of the pelvis under general anesthesia in dorsal recumbency. During a 5s exposure time the horse was actively ventilated to blur the abdominal viscera, which allowed assessment of individual bone structures in 77 horses. A large variation in the shape of the sacral wings, their articulation with the transverse processes of L6, and the relation of the sacrum to the ilium were observed. Females had significantly narrower width of the sacral wings. Broad sacral wings and bony proliferations at the caudal aspect were commonly observed features and their size was highly correlated with gender. In males, caudal osteophytes were significantly larger than in females. Five horses had transitional or hemitransitional vertebrae. Radiography with the ventilation-induced blurring technique is a simple approach that results in diagnostic quality radiographs and delineation of the highly variable bone structures of the sacroiliac region.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Flow mismatch between the supplying artery and the myocardial perfusion region has been observed in patients with internal thoracic artery grafts. Thus coronary flow changes of arterial (internal thoracic artery grafts) and saphenous (saphenous vein grafts) bypass grafts were studied early and late after coronary artery bypass grafting. METHODS: Thirty patients undergoing elective bypass surgery (internal thoracic artery and saphenous vein grafts) were studied intraoperatively and (17 patients) 3 to 10 months postoperatively. Coronary flow was measured intraoperatively with the transit-time Doppler scanning technique. Postoperatively, flow velocity and coronary flow reserve were determined with the Doppler flow wire technique. Quantitative angiographic analysis was used to determine vessel size for calculation of absolute flow. RESULTS: Intraoperatively, internal thoracic artery graft flow was significantly lower than saphenous vein graft flow (31 +/- 8 vs 58 +/- 29 mL/min, P < .01). Postoperatively, internal thoracic artery graft flow increased significantly to 42 +/- 24 mL/min at 3 months and to 56 +/- 30 mL/min (P < .02 vs intraoperative value) at 10 months, respectively. However, saphenous vein graft flow remained unchanged over time (58 +/- 29 to 50 +/- 27 mL/min at 3 months and 46 +/- 27 mL/min at 10 months). Coronary flow reserve was abnormally low intraoperatively in the internal thoracic artery (1.3 +/- 0.3) and saphenous vein (1.6 +/- 0.5) grafts but increased significantly to normal values in both types of graft at follow-up. CONCLUSIONS: Bypass flow of the internal thoracic artery graft is significantly reduced intraoperatively when compared with that of the saphenous vein graft. However, 3 and 10 months after the operation, flow of the internal thoracic artery graft increases significantly and is similar to saphenous vein graft flow. This finding can be explained by an early flow mismatch of the native internal thoracic artery in the presence of a large perfusion territory. During follow-up, there is vascular remodeling of the internal thoracic artery, probably because of endothelium-mediated mechanisms.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the development of a technique it was necessary to learn the fundamentals of ore microscopy as applied to the various minerals of silver, which included the use of reflected polarized light, etch reactions, micro­chemical analysis, and sight recognition of mineral. In addition it was necessary to become familiar with the accepted criteria of sequence, replacement, and other textural phenomena.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

STATE OF THE ART The proximal median nerve compression syndrome includes the pronator teres and the Kiloh-Nevin syndrome. This article presents a new surgical technique of endoscopic assisted median nerve decompression. MATERIAL AND SURGICAL TECHNIQUE Endoscopic scissor decompression of the median nerve is always performed under plexus anaesthesia. It includes 6 key steps documented in this article. We review the indications and limitations of the surgical technique. RESULTS Since 2011, three clinical series have highlighted the advantages of this technique. Functional and subjective results are discussed. We also review the limitations of the technique and its potential for future development. CONCLUSION Although clinical results after endoscopic assisted decompression of the median nerve appear excellent they still need to be compared with conventional techniques. Clinical studies are likely to develop primarily due to the mini-invasive nature of this new surgical technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Proper diagnosis of skin diseases relies on dermatopathology, the most important diagnostic technique in dermatology. Unfortunately, there are few dermatopathology institutions in sub-Saharan Africa, where little is known about the spectrum of histopathological features observed. OBJECTIVES To investigate the spectrum of dermatopathological diagnoses made in a sub-Saharan African reference centre of a large, mainly rural area. PATIENTS/METHODS To retrospectively evaluate all dermatopathological diagnoses made over a period of 5 years at the Regional Dermatology Training Centre (RDTC) in Moshi, Tanzania. RESULTS There were a total of 1554 skin biopsy specimens. In 45% of cases, there were inflammatory diseases, most frequently lichenoid conditions. Cutaneous neoplasms represented 30.4% of all diagnoses, with Kaposi's sarcoma (KS) and, less frequently, squamous cell carcinoma (SCC) being the two most common neoplastic conditions. The latter also reflected the intensive management of persons with albinism in the RDTC. The distribution of histological diagnoses seemed to correlate with the overall clinical spectrum of cutaneous diseases managed in the RDTC. CONCLUSIONS In this African study inflammatory conditions are the main burden of skin diseases leading to a diagnostic biopsy. Our findings provide further evidence that KS, primarily related to the high prevalence of HIV infection is an epidemiological problem. Both SCC and basal cell carcinoma represent another relatively common malignant cutaneous neoplasms, reflecting the presence of specific populations at risk. The challenging spectrum of histological diagnoses observed in this specific African setting with basic working conditions shows that development of laboratory services of good standards and specific training in dermatopathology are urgently needed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Urinary creatinine excretion is used as a marker of completeness of timed urine collections, which are a keystone of several metabolic evaluations in clinical investigations and epidemiological surveys. The current reference values for 24-hour urinary creatinine excretion rely on observations performed in the 1960s and 1970s in relatively small and mostly selected groups, and may thus poorly fit to the present-day general European population. The aim of this study was to establish and validate anthropometry-based age- and sex-specific reference values of the 24-hour urinary creatinine excretion on adult populations with preserved renal function. METHODS We used data from two independent Swiss cross-sectional population-based studies with standardised 24-hour urinary collection and measured anthropometric variables. Only data from adults of European descent, with estimated glomerular filtration rate (eGFR) ≥60 ml/min/1.73 m(2) and reported completeness of the urinary collection were retained. A linear regression model was developed to predict centiles of the 24-hour urinary creatinine excretion in 1,137 participants from the Swiss Survey on Salt and validated in 994 participants from the Swiss Kidney Project on Genes in Hypertension. RESULTS The mean urinary creatinine excretion was 193 ± 41 μmol/kg/24 hours in men and 151 ± 38 μmol/kg/24 hours in women in the Swiss Survey on Salt. The values were inversely correlated with age and body mass index (BMI). Based on current reference values (177 to 221 μmol/kg/24 hours in men and 133 to 177 μmol/kg/24 hours in women), 56% of the urinary collections in the whole population and 67% in people >60 years old would have been considered as inaccurate. A linear regression model with sex, BMI and age as predictor variables was found to provide the best prediction of the observed values and showed a good fit when applied to the validation population. CONCLUSIONS We propose a validated prediction equation for 24-hour urinary creatinine excretion in the general European population, based on readily available variables such as age, sex and BMI, and a few derived normograms to ease its clinical application. This should help healthcare providers to interpret the completeness of a 24-hour urine collection in daily clinical practice and in epidemiological population studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The Endoscopic Release of Carpal Tunnel Syndrome (ECTR) is a minimal invasive approach for the treatment of Carpal Tunnel Syndrome. There is scepticism regarding the safety of this technique, based on the assumption that this is a rather "blind" procedure and on the high number of severe complications that have been reported in the literature. PURPOSE To evaluate whether there is evidence supporting a higher risk after ECTR in comparison to the conventional open release. METHODS We searched MEDLINE (January 1966 to November 2013), EMBASE (January 1980 to November 2013), the Cochrane Neuromuscular Disease Group Specialized Register (November 2013) and CENTRAL (2013, issue 11 in The Cochrane Library). We hand-searched reference lists of included studies. We included all randomized or quasi-randomized controlled trials (e.g. study using alternation, date of birth, or case record number) that compare any ECTR with any OCTR technique. Safety was assessed by the incidence of major, minor and total number of complications, recurrences, and re-operations.The total time needed before return to work or to return to daily activities was also assessed. We synthesized data using a random-effects meta-analysis in STATA. We conducted a sensitivity analysis for rare events using binomial likelihood. We judged the conclusiveness of meta-analysis calculating the conditional power of meta-analysis. CONCLUSIONS ECTR is associated with less time off work or with daily activities. The assessment of major complications, reoperations and recurrence of symptoms does not favor either of the interventions. There is an uncertain advantage of ECTR with respect to total minor complications (more transient paresthesia but fewer skin-related complications). Future studies are unlikely to alter these findings because of the rarity of the outcome. The effect of a learning curve might be responsible for reduced recurrences and reoperations with ECTR in studies that are more recent, although formal statistical analysis failed to provide evidence for such an association. LEVEL OF EVIDENCE I.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE In the present case series, the authors report on seven cases of erosively worn dentitions (98 posterior teeth) which were treated with direct resin composite. MATERIALS AND METHODS In all cases, both arches were restored by using the so-called stamp technique. All patients were treated with standardized materials and protocols. Prior to treatment, a waxup was made on die-cast models to build up the loss of occlusion as well as ensure the optimal future anatomy and function of the eroded teeth to be restored. During treatment, teeth were restored by using templates of silicone (ie, two "stamps," one on the vestibular, one on the oral aspect of each tooth), which were filled with resin composite in order to transfer the planned, future restoration (ie, in the shape of the waxup) from the extra- to the intraoral situation. Baseline examinations were performed in all patients after treatment, and photographs as well as radiographs were taken. To evaluate the outcome, the modified United States Public Health Service criteria (USPHS) were used. RESULTS The patients were re-assessed after a mean observation time of 40 months (40.8 ± 7.2 months). The overall outcome of the restorations was good, and almost exclusively "Alpha" scores were given. Only the marginal integrity and the anatomical form received a "Charlie" score (10.2%) in two cases. CONCLUSION Direct resin composite restorations made with the stamp technique are a valuable treatment option for restoring erosively worn dentitions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The ratio of cystatin C (cysC) to creatinine (crea) is regarded as a marker of glomerular filtration quality associated with cardiovascular morbidities. We sought to determine reference intervals for serum cysC-crea ratio in seniors. Furthermore, we sought to determine whether other low-molecular weight molecules exhibit a similar behavior in individuals with altered glomerular filtration quality. Finally, we investigated associations with adverse outcomes. A total of 1382 subjectively healthy Swiss volunteers aged 60 years or older were enrolled in the study. Reference intervals were calculated according to Clinical & Laboratory Standards Institute (CLSI) guideline EP28-A3c. After a baseline exam, a 4-year follow-up survey recorded information about overall morbidity and mortality. The cysC-crea ratio (mean 0.0124 ± 0.0026 mg/μmol) was significantly higher in women and increased progressively with age. Other associated factors were hemoglobin A1c, mean arterial pressure, and C-reactive protein (P < 0.05 for all). Participants exhibiting shrunken pore syndrome had significantly higher ratios of 3.5-66.5 kDa molecules (brain natriuretic peptide, parathyroid hormone, β2-microglobulin, cystatin C, retinol-binding protein, thyroid-stimulating hormone, α1-acid glycoprotein, lipase, amylase, prealbumin, and albumin) and creatinine. There was no such difference in the ratios of very low-molecular weight molecules (urea, uric acid) to creatinine or in the ratios of molecules larger than 66.5 kDa (transferrin, haptoglobin) to creatinine. The cysC-crea ratio was significantly predictive of mortality and subjective overall morbidity at follow-up in logistic regression models adjusting for several factors. The cysC-crea ratio exhibits age- and sex-specific reference intervals in seniors. In conclusion, the cysC-crea ratio may indicate the relative retention of biologically active low-molecular weight compounds and can independently predict the risk for overall mortality and morbidity in the elderly.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The purpose of this study was to evaluate the diagnostic accuracy of full-body linear X-ray scanning (LS) in multiple trauma patients in comparison to 128-multislice computed tomography (MSCT). Materials and Methods: 106 multiple trauma patients (female: 33; male: 73) were retrospectively included in this study. All patients underwent LS of the whole body, including extremities, and MSCT covering the neck, thorax, abdomen, and pelvis. The diagnostic accuracy of LS for the detection of fractures of the truncal skeleton and pneumothoraces was evaluated in comparison to MSCT by two observers in consensus. Extremity fractures detected by LS were documented. Results: The overall sensitivity of LS was 49.2 %, the specificity was 93.3 %, the positive predictive value was 91 %, and the negative predictive value was 57.5 %. The overall sensitivity for vertebral fractures was 16.7 %, and the specificity was 100 %. The sensitivity was 48.7 % and the specificity 98.2 % for all other fractures. Pneumothoraces were detected in 12 patients by CT, but not by LS. 40 extremity fractures were detected by LS, of which 4 fractures were dislocated, and 2 were fully covered by MSCT. Conclusion: The diagnostic accuracy of LS is limited in the evaluation of acute trauma of the truncal skeleton. LS allows fast whole-body X-ray imaging, and may be valuable for detecting extremity fractures in trauma patients in addition to MSCT. Key Points: • The overall sensitivity of LS for truncal skeleton injuries in multiple-trauma patients was < 50 %.• The diagnostic reference standard MSCT is the preferred and reliable imaging modality.• LS may be valuable for quick detection of extremity fractures. Citation Format: • Jöres APW., Heverhagen JT, Bonél H et al. Diagnostic Accuracy of Full-Body Linear X-Ray Scanning in Multiple Trauma Patients in Comparison to Computed Tomography. Fortschr Röntgenstr 2016; 188: 163 - 171.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In the midst of health care reform, and as health care organizations reorganize to provide more cost-effective healthcare, the population is being shifted into new healthcare delivery systems such as health insurance purchasing alliances, and health maintenance organizations. These new models of delivery are usually organized within resource restricted and data limited environments. Health care planners are faced with the challenge of identifying priorities for preventive and primary care services within these newly organized populations (Medicare HMO, Medicaid HMO, etc.). The author proposes a technique usually employed in epidemiology--attributable risk estimation--as a planning methodology to establish preventive health priorities within newly organized populations. Illustrations of the methodology are provided utilizing the Texas 1992 population. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A suite of petrophysical properties - velocity, resistivity, bulk density, porosity, and matrix density - was measured on 88 core plugs from the CRP-3 drillhole. Core-plug bulk densities were used to recalibrate both whole-core and downhole bulk density logs. Core-plug measurements of matrix density permit conversion of the whole-core and downhole bulk density logs to porosity. Both velocity and formation factor (a normalized measure of resistivity) are strongly correlated with porosity. The velocity/porosity pattern is similar to that for the lower part of CRP-2A and is consistent with the empirical relationship for sandstones. Core-plug and whole-core measurements of P-wave velocity at atmospheric pressure exhibit excellent agreement. Measurements of velocity as a function of pressure indicate a significantly higher velocity sensitivity to pressure than has been observed at CRP-1 and CRP-2A; rebound or presence of microcracks at CRP-3 may be responsible. The percentage difference between velocities at in situ pressures and atmospheric pressures increases downhole from 0% at the seafloor to 9% at the bottom. This pattern can be used to correct whole-core velocity data, measured at atmospheric pressure, to in situ velocities for depth-to-time conversion and associated comparison to the seismic profile across the drillsite