987 resultados para statistical methodology
Resumo:
In an effort to achieve greater consistency and comparability in state-wide seat belt use reporting, the National Highway Traffic Safety Administration (NHTSA) issued new requirements in 2011 for observing and reporting future seat belt use. The requirements included the involvement of a qualified statistician in the sampling and weighting portions of the process as well as a variety of operational details. The Iowa Governor’s Traffic Safety Bureau contracted with Iowa State University’s Survey & Behavioral Research Services (SBRS) in 2011 to develop the study design and data collection plan for the State of Iowa annual survey that would meet the new requirements of the NHTSA. A seat belt survey plan for Iowa was developed by SBRS with statistical expertise provided by Zhengyuan Zhu, Ph.D., Associate Professor of Statistics at Iowa State University and was approved by NHTSA on March 19, 2012.
Resumo:
In an effort to achieve greater consistency and comparability in state-wide seat belt use reporting, the National Highway Traffic Safety Administration (NHTSA) issued new requirements in 2011 for observing and reporting future seat belt use. The requirements included the involvement of a qualified statistician in the sampling and weighting portions of the process as well as a variety of operational details. The Iowa Governor’s Traffic Safety Bureau contracted with Iowa State University’s Survey & Behavioral Research Services (SBRS) in 2011 to develop the study design and data collection plan for the State of Iowa annual survey that would meet the new requirements of the NHTSA. A seat belt survey plan for Iowa was developed by SBRS with statistical expertise provided by Zhengyuan Zhu, Ph.D., Associate Professor of Statistics at Iowa State University and was approved by NHTSA on March 19, 2012.
Resumo:
In an effort to achieve greater consistency and comparability in state-wide seat belt use reporting, the National Highway Traffic Safety Administration (NHTSA) issued new requirements in 2011 for observing and reporting future seat belt use. The requirements included the involvement of a qualified statistician in the sampling and weighting portions of the process as well as a variety of operational details. The Iowa Governor’s Traffic Safety Bureau contracted with Iowa State University’s Survey & Behavioral Research Services (SBRS) in 2011 to develop the study design and data collection plan for the State of Iowa annual survey that would meet the new requirements of the NHTSA. A seat belt survey plan for Iowa was developed by SBRS with statistical expertise provided by Zhengyuan Zhu, Ph.D., Associate Professor of Statistics at Iowa State University and Director of the Center for Survey Statistics and Methodology. The plan was approved by NHTSA on March 19, 2012.
Resumo:
A non-linear least-squares methodology for simultaneously estimating parameters of selectivity curves with a pre-defined functional form, across size classes and mesh sizes, using catch size frequency distributions, was developed based on the model of Kirkwood and Walker [Kirkwood, G.P., Walker, T.L, 1986. Gill net selectivities for gummy shark, Mustelus antarcticus Gunther, taken in south-eastern Australian waters. Aust. J. Mar. Freshw. Res. 37, 689-697] and [Wulff, A., 1986. Mathematical model for selectivity of gill nets. Arch. Fish Wiss. 37, 101-106]. Observed catches of fish of size class I in mesh m are modeled as a function of the estimated numbers of fish of that size class in the population and the corresponding selectivities. A comparison was made with the maximum likelihood methodology of [Kirkwood, G.P., Walker, T.I., 1986. Gill net selectivities for gummy shark, Mustelus antarcticus Gunther, taken in south-eastern Australian waters. Aust. J. Mar. Freshw. Res. 37, 689-697] and [Wulff, A., 1986. Mathematical model for selectivity of gill nets. Arch. Fish Wiss; 37, 101-106], using simulated catch data with known selectivity curve parameters, and two published data sets. The estimated parameters and selectivity curves were generally consistent for both methods, with smaller standard errors for parameters estimated by non-linear least-squares. The proposed methodology is a useful and accessible alternative which can be used to model selectivity in situations where the parameters of a pre-defined model can be assumed to be functions of gear size; facilitating statistical evaluation of different models and of goodness of fit. (C) 1998 Elsevier Science B.V.
Resumo:
In acquired immunodeficiency syndrome (AIDS) studies it is quite common to observe viral load measurements collected irregularly over time. Moreover, these measurements can be subjected to some upper and/or lower detection limits depending on the quantification assays. A complication arises when these continuous repeated measures have a heavy-tailed behavior. For such data structures, we propose a robust structure for a censored linear model based on the multivariate Student's t-distribution. To compensate for the autocorrelation existing among irregularly observed measures, a damped exponential correlation structure is employed. An efficient expectation maximization type algorithm is developed for computing the maximum likelihood estimates, obtaining as a by-product the standard errors of the fixed effects and the log-likelihood function. The proposed algorithm uses closed-form expressions at the E-step that rely on formulas for the mean and variance of a truncated multivariate Student's t-distribution. The methodology is illustrated through an application to an Human Immunodeficiency Virus-AIDS (HIV-AIDS) study and several simulation studies.
Resumo:
Response surface methodology based on Box-Behnken (BBD) design was successfully applied to the optimization in the operating conditions of the electrochemical oxidation of sanitary landfill leachate aimed for making this method feasible for scale up. Landfill leachate was treated in continuous batch-recirculation system, where a dimensional stable anode (DSA(©)) coated with Ti/TiO2 and RuO2 film oxide were used. The effects of three variables, current density (milliampere per square centimeter), time of treatment (minutes), and supporting electrolyte dosage (moles per liter) upon the total organic carbon removal were evaluated. Optimized conditions were obtained for the highest desirability at 244.11 mA/cm(2), 41.78 min, and 0.07 mol/L of NaCl and 242.84 mA/cm(2), 37.07 min, and 0.07 mol/L of Na2SO4. Under the optimal conditions, 54.99 % of chemical oxygen demand (COD) and 71.07 ammonia nitrogen (NH3-N) removal was achieved with NaCl and 45.50 of COD and 62.13 NH3-N with Na2SO4. A new kinetic model predicted obtained from the relation between BBD and the kinetic model was suggested.
Resumo:
Often in biomedical research, we deal with continuous (clustered) proportion responses ranging between zero and one quantifying the disease status of the cluster units. Interestingly, the study population might also consist of relatively disease-free as well as highly diseased subjects, contributing to proportion values in the interval [0, 1]. Regression on a variety of parametric densities with support lying in (0, 1), such as beta regression, can assess important covariate effects. However, they are deemed inappropriate due to the presence of zeros and/or ones. To evade this, we introduce a class of general proportion density, and further augment the probabilities of zero and one to this general proportion density, controlling for the clustering. Our approach is Bayesian and presents a computationally convenient framework amenable to available freeware. Bayesian case-deletion influence diagnostics based on q-divergence measures are automatic from the Markov chain Monte Carlo output. The methodology is illustrated using both simulation studies and application to a real dataset from a clinical periodontology study.
Resumo:
A proper cast is essential for a successful rehabilitation with implant prostheses, in order to produce better structures and induce less strain on the implants. The aim of this study was to evaluate the precision of four different mold filling techniques and verify an accurate methodology to evaluate these techniques. A total of 40 casts were obtained from a metallic matrix simulating three unit implant-retained prostheses. The molds were filled using four different techniques in four groups (n = 10): Group 1 - Single-portion filling technique; Group 2 - Two-step filling technique; Group 3 - Latex cylinder technique; Group 4 - Joining the implant analogs previously to the mold filling. A titanium framework was obtained and used as a reference to evaluate the marginal misfit and tension forces in each cast. Vertical misfit was measured with an optical microscope with an increase of 120 times following the single-screw test protocol. Strain was quantified using strain gauges. Data were analyzed using one-way ANOVA (Tukey's test) (α =0.05). The correlation between strain and vertical misfit was evaluated by Pearson test. The misfit values did not present statistical difference (P = 0.979), while the strain results showed statistical difference between Groups 3 and 4 (P = 0.027). The splinting technique was considered to be as efficient as the conventional technique. The strain gauge methodology was accurate for strain measurements and cast distortion evaluation. There was no correlation between strain and marginal misfit.
Resumo:
Didanosine-loaded chitosan microspheres were developed applying a surface-response methodology and using a modified Maximum Likelihood Classification. The operational conditions were optimized with the aim of maintaining the active form of didanosine (ddI), which is sensitive to acid pH, and to develop a modified and mucoadhesive formulation. The loading of the drug within the chitosan microspheres was carried out by ionotropic gelation technique with sodium tripolyphosphate (TPP) as cross-linking agent and magnesium hydroxide (Mg(OH)2) to assure the stability of ddI. The optimization conditions were set using a surface-response methodology and applying the Maximum Likelihood Classification, where the initial chitosan concentration, TPP and ddI concentration were set as the independent variables. The maximum ddI-loaded in microspheres (i.e. 1433mg of ddI/g chitosan), was obtained with 2% (w/v) chitosan and 10% TPP. The microspheres depicted an average diameter of 11.42μm and ddI was gradually released during 2h in simulated enteric fluid.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física