954 resultados para saddle velocities


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Euryhaline crustaceans rarely hyporegulates and employ the driving force of the Na,K-ATPase, located at the basal surface of the gill epithelium, to maintain their hemolymph osmolality within a range compatible with cell function during hyper-regulation. Since polyamine levels increase during the adaptation of crustaceans to hyperosmotic media, we investigate the effect of exogenous polyamines on Na,K-ATPase activity in the posterior gills of Callinectes danae, a euryhaline swimming crab. Polyamine inhibition was dependent on cation concentration, charge and size in the following order: spermine > spermidine > putrescine. Spermidine affected K-0.5 values for Na+ with minor alterations in K-0.5 values for K+ and N-H-4(+), causing a decrease in maximal velocities under saturating Na+, K+ and NH4+ concentrations. Phosphorylation measurements in the presence of 20 mu M ATP revealed that the Na,K-ATPase possesses a high affinity site for this substrate. In the presence of 10 mM Na+, both spermidine and spermine inhibited formation of the phosphoenzyme; however, in the presence of 100 mM Na+, the addition of these polyamines allowed accumulation of the phosphoenzyme. The polyamines inhibited pumping activity, both by competing with Na+ at the Na+-binding site, and by inhibiting enzyme dephosphorylation. These findings suggest that polyamine-induced inhibition of Na,K-ATPase activity may be physiologically relevant during migration to fully marine environments. (c) 2008 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiofirequency ablation of the pulmonary veins has been used to treat patients with paroxysmal atrial fibrillation (AF), and atrial damage after ablation is an issue of concern. To evaluate left atrial function shortly and midterm after ablation, 33 consecutive patients with paroxysmal AF were studied at baseline, 24 hours, and >= 6 months after ablation. Patients in sinus rhythm with normal ventricular function were included in the study. Echocardiographic measurements of left atrial volumes (Simpson`s rule) and transmitral and tissue Doppler myocardial (A`) velocities at the septal and lateral mitral annulus were undertaken at each time. Left atrial emptying fraction (EF; maximal - minimal left atrial volume/maximal left atrial volume) was used to express left atrial function. After 8 +/- 2 months, 30 of 33 patients returned (23 men, age 53 +/- 13 years), and all except 2 were in sinus rhythm. Shortly after ablation, left atrial minimal volumes increased (from 30 +/- 15 to 35 +/- 15 ml; p = 0.02), with maximal volumes unchanged, resulting in decreased left atrial EF (from 47 +/- 8 to 40 +/- 7 ml; p <0.05). Tissue Doppler septal A` velocities also decreased (from 8.2 +/- 1.8 to 6.9 +/- 2.0 cm/s; p <0.05). However, after midterm follow-up, both left atrial EF and septal A` velocities had slightly increased compared with shortly after ablation, although left atrial volumes remained similar to baseline. Septal A` velocity changes paralleled left atrial EF both shortly (r = 0.46, p = 0.02) and at midterm after ablation (r = 0.47, p = 0.01). In conclusion, after radiofrequency ablation, patients with paroxysmal AF experienced an initial impairment in atrial function, with improvement at longer term follow-up. (C) 2009 Elsevier Inc. All rights reserved. (Am J Cardiol 2009;103: 395-398)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To compare clinical evaluation, electrophysiological investigation and magnetic resonance findings in assessing the severity of idiopathic carpal tunnel syndrome. Patients and methods: Seventy-four patients with idiopathic carpal tunnel syndrome were prospectively recruited. Clinical evaluation included symptoms severity score and two-point discrimination, sensory and motor nerve conduction velocities were determined by electroneuromyography and imaging parameters were obtained after wrist magnetic resonance. The Wilcoxon test was used to define the differences between measurements of median nerve area. The Pearson and Spearman correlation tests were used to determine the relationships between all the measured parameters. Results: Cross-sectional area of median nerve was smaller at hamate level than at radio-ulnar joint and pisiform levels (p < 0.001). With exception of median nerve area at hamate level, there was a lower degree of correlation between MRI parameters and findings obtained by clinical assessments and electrophysiological measurements. The median nerve area at hamate level correlated negatively with duration of symptoms, two-point discrimination, symptoms severity score and positively with sensory nerve conduction velocity (P < 0.01). Conclusion: In patients with idiopathic carpal tunnel syndrome, median nerve area measured by wrist magnetic resonance at hamate level may be considered as a valuable indicator to grading the severity of disease. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An experimental study of the effect of fuel stagnation temperature on mixing in a supersonic hydrogen-air flame is described, The combustor consisted of a constant-area rectangular duct with a centrally located fuel-injection strut that spanned the width. A high-enthalpy stream of air was supplied by a free-piston shock tunnel, and heated hydrogen fuel, supplied by a gun-tunnel, was injected into the freestream as a coflowing planar jet. The freestream total enthalpies were 5.6, 6.5, and 9 MJ/kg, and fuel stagnation temperatures were 300, 450, and 700 K, Raising the fuel stagnation temperature increased the fuel velocity to be near that of the airstream and resulted in a decrease in the mixing rate, Even as the fuel and air velocities became equal, significant mixing still occurred because of a large difference in density, Increasing the freestream enthalpy reduced the difference between the initial air temperature and the adiabatic flame temperature, which in turn reduced the heat addition, and subsequently, the amount of pressure rise in the duct.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A novel flow-tagging technique is presented which was employed to measure gas velocities in the free stream of a shock tube. This method is based on the laser spectroscopic techniques of Laser-Enhanced Ionisation (LEI) and Laser-Induced Fluorescence (LIF). The flow in the shock tube is seeded with small amounts of sodium, and LEI is used to produce a substantial depletion of neutral sodium atom concentration in a well-defined region of the flow, by using two wavelength-resonance excitation and subsequent collisional ionisation. At a specific time delay, single-laser-pulse planar LIF is utilised to produce a two-dimensional (2-D) inverse image of the depleted tagged region downstream of the flow. By measuring the displacement of the tagged region, free stream velocities in a shock tube were determined. Large variations in the concentration of sodium seeded into the flow were observed and even in the presence of these large variations accurate free-stream velocity measurements were obtained. The experimentally determined value for velocity compares very well with the predicted velocity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fluid mixing in steady and unsteady Bow through a channel containing periodic square obstructions has been studied using a finite-difference simulation to determine fluid velocities, followed by the use of passive marker particle advection to look at fluid transport out of the cavities formed between each of the obstructions. The geometry and Bow conditions were chosen from the work by Perkins (1989, M.S. Thesis, Lehigh University; 1992, Ph.D. Thesis, Lehigh University); who investigated heat transfer enhancement due to unsteady flow through such an obstructed channel. Particle advection shows that Bow regimes which are predicted to give good mixing based on snapshots of instantaneous streamline contour plots were not necessarily able to efficiently mix fluid which started in the cavity regions throughout the channel. The use of Poincare sections shows regular regions existing under these conditions which inhibit efficient fluid transport. These regular regions are found to disappear when the unsteady Bow velocity is increased. (C) 1997 Elsevier Science Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study aimed to quantify the efficiency and smoothness of voluntary movement in Huntington's disease (HD) by the use of a graphics tablet that permits analysis of movement profiles. In particular, we aimed to ascertain whether a concurrent task (digit span) would affect the kinematics of goal-directed movements. Twelve patients with HD and their matched controls performed 12 vertical zig-zag movements, with both left and right hands (with and without the concurrent task), to large or small circular targets over long or short extents. The concurrent task was associated with shorter movement times and reduced right-hand superiority. Patients with HD were overall slower, especially with long strokes, and had similar peak velocities for both small and large targets, so that controls could better accommodate differences in target size. Patients with HD spent more time decelerating, especially with small targets, whereas controls allocated more nearly equal proportions of time to the acceleration and deceleration phases of movement, especially with large targets. Short strokes were generally less force inefficient than were long strokes, especially so for either hand in either group in the absence of the concurrent task, and for the right hand in its presence. With the concurrent task, however, the left hand's behavior changed differentially for the two groups; for patients with HD, it became more force efficient with short strokes and even less efficient with long strokes, whereas for controls, it became more efficient with long strokes. Controls may be able to divert attention away from the inferior left hand, increasing its automaticity, whereas patients with HD, because of disease, may be forced to engage even further online visual control under the demands of a concurrent task. Patients with HD may perhaps become increasingly reliant on terminal visual guidance, which indicates an impairment in constructing and refining an internal representation of the movement necessary for its. effective execution. Basal ganglia dysfunction may impair the ability to use internally generated cues to guide movement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To determine reference values for tissue Doppler imaging (TDI) and pulsed Doppler echocardiography for left ventricular diastolic function analysis in a healthy Brazilian adult population. Observations were based on a randomly selected healthy population from the city of Vitoria, Espirito Santo, Brazil. Healthy volunteers (n = 275, 61.7% women) without prior histories of cardiovascular disease underwent transthoracic echocardiography. We analyzed 175 individuals by TDI and evaluated mitral annulus E`- and A`-waves from the septum (S) and lateral wall (L) to calculate E`/A` ratios. Using pulsed Doppler echocardiography, we further analyzed the mitral E- and A-waves, E/A ratios, isovolumetric relaxation times (IRTs), and deceleration times (DTs) of 275 individuals. Pulsed Doppler mitral inflow mean values for men were as follows: E-wave: 71 +/- 16 cm/sec, A-wave: 68 +/- 15 cm/sec, IRT: 74.8 +/- 9.2 ms, DT: 206 +/- 32.3 ms, E/A ratio: 1.1 +/- 0.3. Pulsed Doppler mitral inflow mean values for women were as follows: E-wave: 76 +/- 17, A-wave: 69 +/- 14 cm/sec, IRT: 71.2 +/- 10.5 ms, DT: 197 +/- 33.3 ms, E/A ratio: 1.1 +/- 0.3. IRT and DT values were higher in men than in women (P = 0.04 and P = 0.007, respectively). TDI values in men were as follows: E`S: 11 +/- 3 cm/sec, A`S: 13 +/- 2 cm/sec, E`S/A`S: 0.89 +/- 0.2, E`L: 14 +/- 3 cm/sec, A`L: 14 +/- 2 cm/sec, E`L/A`L: 1.1 +/- 0.4. E-wave/ E`S ratio: 6.9 +/- 2.2; E-wave / E`L ratio: 4.9 +/- 1.7. In this study, we determined pulsed Doppler and TDI derived parameters for left ventricular diastolic function in a large sample of healthy Brazilian adults. (Echocardiography 2010;27:777-782).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We investigated the impact of obesity on the abnormalities of systolic and diastolic regional left ventricular (LV) function in patients with or without hypertension or hypertrophy, and without heart failure. We studied 120 individuals divided into 6 groups of 20 patients (42 +/- 6 years, 60 females) using standard and pulsed-wave tissue Doppler imaging (TDI) echocardiography, and heterogeneity index (HI): nonobese (I: no hypertension, no hypertrophy, control group; II: hypertension, no hypertrophy; III: hypertension and hypertrophy) and obese (IV: no hypertension, no hypertrophy; V: hypertension, no hypertrophy; VI: hypertension and hypertrophy). The criterion for obesity was BMI >= 30 kg/m(2), for hypertension was blood pressure >= 140/90 mm Hg, for hypertrophy in nonobese was LV mass/body surface area (BSA) >134 g/m(2) (men) and >110 mg/m(2) (women), and in obese was LV mass/height((2.7)) >50 (men) and >40 (women). Obese groups had normal LV ejection fraction compared with nonobese groups, but decreased longitudinal and radial systolic myocardial peak velocities (S`), and early diastolic myocardial peak velocity (E`). Also, a great variability of E` and late diastolic myocardial peak velocity (A`) from the longitudinal basal region was observed in obese groups (E` basal nonobese: 11 +/- 7 vs. obese 19 +/- 11, P < 0.001, A` basal nonobese: 7 +/- 4 vs. obese 11 +/- 7, P < 0.001). Our findings were more evident when comparing groups IV with V and VI, with the latter having concentric hypertrophy and obvious segmental systolic and diastolic dysfunctions. Subclinical myocardial alterations and increased variability of the velocities were observed in obese groups, especially with hypertension and hypertrophy, reflecting impaired regional LV relaxation, segmental atrial, and systolic dysfunctions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Color Doppler myocardial imaging (CDMI) allows the calculation of local longitudinal or radial strain rate (SR) and strain (epsilon). The aims of this study were to determine the feasibility and reproducibility of longitudinal and radial SR and epsilon in neonates during the first hours of life and to establish reference values. Methods: Data were obtained from 55 healthy neonates (29 male; mean age, 20 +/- 14 hours; mean birth weight, 3,174 +/- 374 g). Apical and parasternal views quantified regional longitudinal and radial SR and epsilon in differing ventricular wall segments. Values at peak systole, early diastole, and late diastole were calculated from the extracted curves. CDMI data acquired at 300 +/- 50 frames/s were analyzed offline. Three consecutive cardiac cycles were measured during normal respiration. The timing of specific systolic or diastolic regional events was determined. Multiple comparisons between walls and segments were made. Results: Left ventricular (LV) longitudinal deformation showed basal differences compared with apical segments within one specific wall. Right ventricular (RV) longitudinal deformation was not homogeneous, with significant differences between basal and apical segments. Longitudinal 3 values were higher in the RV free basal and middle wall segments compared with the left ventricle. In the RV free wall apical segment, longitudinal SR and 3 were maximal. LV systolic SR and epsilon values were higher radially compared with longitudinally (radial peak systolic SR midportion, 2.9 +/- 0.6 s(-1); radial peak systolic epsilon 53.8 +/- 19%; longitudinal peak systolic SR midportion, -1.8 +/- 0.5 s(-1); longitudinal peak systolic epsilon, -24.8 +/- 3%; P < .01). Longitudinal systolic epsilon and SR interobserver variability values were 1.2% and 0.7%, respectively. Conclusion: Ultrasound-based SR and 3 imaging is a practical and reproducible clinical technique in neonates, allowing the calculation of regional longitudinal and radial deformation in RV and LV segments. These regional SR and epsilon indices represent new, noninvasive parameters that can quantify normal neonate regional cardiac function. Independent from visual interpretation, they can be used as reference values for diagnosis in ill neonates. (J Am Soc Echocardiogr 2009;22:369-375.)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Accurate diagnosis of portal vein (PV) stenosis by real-time and color Doppler US (CD-US) after segmental liver transplantation in children can decrease morbidity by avoiding unnecessary biopsy, PV hypertension, thrombosis and loss of the graft. Objective To evaluate CD-US parameters for the prediction of PV stenosis after segmental liver transplantation in children. Materials and methods We retrospectively reviewed 61 CD-US examinations measuring the diameter at the PV anastomosis, velocities at the anastomosis (PV1) and in the segment proximal to the anastomosis (PV2), and the PV1/PV2 velocity ratio. The study group comprised patients with stenosis confirmed by angiography and the control group comprised patients with a good clinical outcome. Results PV stenosis was seen in 12 CD-US examinations. The mean PV diameter was smaller in the study group (2.6 mm versus 5.7 mm) and a PV diameter of < 3.5 mm was highly predictive of stenosis (sensitivity 100%, specificity 91.8%). Conclusion A PV diameter of < 3.5 mm is a highly predictive CD-US parameter for the detection of hemodynamically significant stenosis on angiography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Supraceliac aortic clamping in major vascular procedures promotes splanchnic ischemia and reperfusion (I/R) injury that may induce endothelial dysfunction, widespread inflammation, multiorgan dysfunction, and death. We tested the hypothesis that local or remote ischemic preconditioning (IPC) may be protective against injury after supraceliac aortic clamping through the modulation of mesenteric leukocyte-endothelial interactions, as evaluated with intravital microscopy and expression of adhesion molecules. Methods: Fifty-six male Wistar rats (weight, 190 to 250 g), were divided into four groups of 14 rats each: control sham surgery without aortic occlusion; I/R through supraceliac aortic occlusion for 20 minutes, followed by 120 minutes of reperfusion; local IPC through supraceliac aortic occlusion for two cycles of 5 minutes of ischemia and 5 minutes of reperfusion, followed by the same protocol of the IR group; remote IPC through infrarenal aortic occlusion for two cycles of 10 minutes of ischemia and 10 minutes of reperfusion, followed by the same protocol of the IR group. Seven animals per group were used to evaluate in vivo leukocyte-endothelial interactions in postcapillary venules with intravital microscopy and another seven animals per group were used to collect mesentery samples for inmmnohistochemistry demonstration of adhesion molecules expression. Results: Supraceliac aortic occlusion increased the number of rolling leukocytes with slower velocities and increased the number of adherent leukocytes to the venular surface and leukocyte migration to the interstitium. The expression of P-selectin, E-selectin, and intercellular adhesion molecule-1 was also increased significantly after I/R. Local or remote IPC reduced the leukocyte recruitment in vivo and normalized the expression of adhesion molecules. Conclusions: Local or remote IPC reduces endothelial dysfunction on mesenteric microcirculation caused by I/R injury after supraceliac aortic clamping. (J Vase Surg 2010;52:1321-9.) Clinical Relevance: The present study demonstrates that ischemia and reperfusion injury induced by supraceliac aortic occlusion promotes endothelial dysfunction and leukocyte recruitment on mesenteric microcirculation. Local and remote preconditioning reduced leukocyte-endothelial interactions and normalized the expression of endothelial adhesion molecules involved in this process. Although we recognize the limitation of an experimental model, our findings suggest that local and remote ischemic preconditioning minimize the endothelial dysfunction and leukocyte recruitment events that play a central role in systemic inflammation and multiorgan dysfunction after major aortic reconstructions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Restoration of nerve continuity and effective maintenance of coaptation are considered fundamental principles of end-to-end peripheral nerve repair. OBJECTIVE: To evaluate the influence of the number of stitches on axonal regeneration and collagen production after neurorrhaphy. METHODS: Thirty male Wistar rats were equally divided into 3 groups and were all operated on with the right sciatic nerve exposed. In 2 groups, the nerve was sectioned and repaired by means of 3 (group B) or 6 (group C) epineurium sutures with 100 monofilament nylon. One group (group A) was used as a control. Each animal from groups B and C underwent electrophysiological evaluation with motor action potential recordings before nerve section and again at an 8-week interval after neurorrhaphy. Nerve biopsy specimens were used for histomorphometric assessment of axonal regeneration and quantification of collagen at the repair site. RESULTS: Animals from group C had significantly lower motor action potential conduction velocities compared with control animals (P = .02), and no significant difference was seen between groups B and C. Parameters obtained from morphometric evaluation were not significantly different between these 2 groups. Type I collagen and III collagen in the epineurium were significantly higher in group C than in either the control group (P = .001 and P = .003) or group B (P = .01 and P = .02). No differences were identified for collagen I and III in the endoneurium. CONCLUSION: Using 6 sutures for nerve repair is associated with worse electrophysiological outcomes and higher amounts of type I and III collagen in the epineurium compared with control. Neurorraphy with 6 stitches is also related to a significant increase in epineurium collagen I and III compared with 3-stitch neurorraphy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To determine normal blood flow velocities across the fetal tricuspid valve (TV) at 11-13 weeks and 6 days of gestation and to examine the reproducibility of these measurements. Methods A prospective study involving 166 normal singleton pregnancies examined at 11-13 weeks and 6 days was carried out. Descriptive analysis of E- and A-waves` maximum velocities, E/A ratio, duration of the cardiac cycle (C) and diastole (D) and D/C ratio were calculated. Intraobserver and interobserver agreement analysis was performed in a subgroup of 12 cases. Results Average (+/- SD) flow velocities were: E-wave, 25.0 (+/- 4.6) cm/s; A-wave. 42.9 (+/- 5.9) cm/s; E/A, 0.58 (+/- 0.07); cardiac cycle, 390 (+/- 21.1) ms; diastole, 147 (+/- 18) ms and D/C, 0.38 (+/- 0.04). Significant correlation was observed between all parameters (except A-wave) and gestational age but not with nuchal translucency (NT). Intraclass correlation coefficients (interobserver, intraobsever examiner I and intraobserver examiner 2) were: E-wave, 0.53, 0.53 and 0.64; A-wave, 0.45, 0.46 and 0.49; cardiac cycle, 0.70, 0.79 and 0.84 and diastole, 0.63, 0.85 and 0.82, respectively. Conclusions The present study establishes normal Doppler parameters for blood flow across the TV at 11 - 13 weeks and 6 days and demonstrates that these parameters do not correlate with NT measurement and have good/moderate reproducibility. Copyright (C) 2010 John Wiley & Sons, Ltd.