901 resultados para radius of curvature measurement


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The International Standard ISO 140-5 on field measurements of airborne sound insulation of façades establishes that the directivity of the measurement loudspeaker should be such that the variation in the local direct sound pressure level (ΔSPL) on the sample is ΔSPL < 5 dB (or ΔSPL < 10 dB for large façades). This condition is usually not very easy to accomplish nor is it easy to verify whether the loudspeaker produces such a uniform level. Direct sound pressure levels on the ISO standard façade essentially depend on the distance and directivity of the loudspeaker used. This paper presents a comprehensive analysis of the test geometry for measuring sound insulation and explains how the loudspeaker directivity, combined with distance, affects the acoustic level distribution on the façade. The first sections of the paper are focused on analysing the measurement geometry and its influence on the direct acoustic level variations on the façade. The most favourable and least favourable positions to minimise these direct acoustic level differences are found, and the angles covered by the façade in the reference system of the loudspeaker are also determined. Then, the maximum dimensions of the façade that meet the conditions of the ISO 140-5 standard are obtained for the ideal omnidirectional sound source and the piston radiating in an infinite baffle, which is chosen as the typical radiation pattern for loudspeakers. Finally, a complete study of the behaviour of different loudspeaker radiation models (such as those usually utilised in the ISO 140-5 measurements) is performed, comparing their radiation maps on the façade for searching their maximum dimensions and the most appropriate radiation configurations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper a previously developed theoretical model of the measurement process performed by a transit-time ultrasonic anemometer is applied to a fluid flowing through a circular section pipe. This model considers the influence of the shift of the acoustic pulse trajectory from straight propagation due to the flow on the measured speed. The aim of this work is to estimate the errors induced in the measured velocity by the shift of the acoustic pulse trajectory. Using different duct’s flow models, laminar and turbulent regimes have been analyzed. The results show that neglecting the effect of shift of the acoustic pulse trajectory leads to flow rate measurement underestimation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of 8-hydroxy-2′-deoxyguanosine (8-OH-dGuo) in DNA by high-performance liquid chromatography/mass spectrometry (LC/MS) was studied. A methodology was developed for separation by LC of 8-OH-dGuo from intact and modified nucleosides in DNA hydrolyzed by a combination of four enzymes: DNase I, phosphodiesterases I and II and alkaline phosphatase. The atmospheric pressure ionization-electrospray process was used for mass spectral measurements. A stable isotope-labeled analog of 8-OH-dGuo was used as an internal standard for quantification by isotope-dilution MS (IDMS). Results showed that LC/IDMS with selected ion-monitoring (SIM) is well suited for identification and quantification of 8-OH-dGuo in DNA at background levels and in damaged DNA. The sensitivity level of LC/IDMS-SIM was found to be comparable to that reported previously using LC-tandem MS (LC/MS/MS). It was found that approximately five lesions per 106 DNA bases can be detected using amounts of DNA as low as 2 µg. The results also suggest that this lesion may be quantified in DNA at levels of one lesion per 106 DNA bases, or even lower, when more DNA is used. Up to 50 µg of DNA per injection were used without adversely affecting the measurements. Gas chromatography/isotope-dilution MS with selected-ion monitoring (GC/IDMS-SIM) was also used to measure this compound in DNA following its removal from DNA by acidic hydrolysis or by hydrolysis with Escherichia coli Fpg protein. The background levels obtained by LC/IDMS-SIM and GC/IDMS-SIM were almost identical. Calf thymus DNA and DNA isolated from cultured HeLa cells were used for this purpose. This indicates that these two techniques can provide similar results in terms of the measurement of 8-OH-dGuo in DNA. In addition, DNA in buffered aqueous solution was damaged by ionizing radiation at different radiation doses and analyzed by LC/IDMS-SIM and GC/IDMS-SIM. Again, similar results were obtained by the two techniques. The sensitivity of GC/MS-SIM for 7,8-dihydro-8-oxoguanine was also examined and found to be much greater than that of LC/MS-SIM and the reported sensitivity of LC/MS/MS for 8-OH-dGuo. Taken together, the results unequivocally show that LC/IDMS-SIM is well suited for sensitive and accurate measurement of 8-OH-dGuo in DNA and that both LC/IDMS-SIM and GC/IDMS-SIM can provide similar results.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The problem of similarity measurement of biological signals is considered on this article. The dynamic time warping algorithm is used as a possible solution. A short overview of this algorithm and its modifications are given. Testing procedure for different modifications of DTW, which are based on artificial test signals, are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present unified, systematic derivations of schemes in the two known measurement-based models of quantum computation. The first model (introduced by Raussendorf and Briegel, [Phys. Rev. Lett. 86, 5188 (2001)]) uses a fixed entangled state, adaptive measurements on single qubits, and feedforward of the measurement results. The second model (proposed by Nielsen, [Phys. Lett. A 308, 96 (2003)] and further simplified by Leung, [Int. J. Quant. Inf. 2, 33 (2004)]) uses adaptive two-qubit measurements that can be applied to arbitrary pairs of qubits, and feedforward of the measurement results. The underlying principle of our derivations is a variant of teleportation introduced by Zhou, Leung, and Chuang, [Phys. Rev. A 62, 052316 (2000)]. Our derivations unify these two measurement-based models of quantum computation and provide significantly simpler schemes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

NMR spectroscopy and relaxometry were used to investigate microemulsion formation in supercritical CO2. The droplets were stabilised by the salt of a perfluorinated polyether. Spontaneous microemulsion formation was observed over a period of 5 h in the absence of applied sheer. Time-resolved relaxation times of the surfactant tail showed a stepwise increase in mobility of the tail over this period. Conversely, the translational mobility of water confined within the droplet decreased over the same interval. This data is consistent with the gradual decrease in droplet size as time progressed. Indeed, NMR self-diffusion coefficients were used to show that droplets with a radius of approximately 5 nm were formed at equilibrium.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Scanning capacitance microscopy (SCM) measurement is a proposed tool for dopant profile extraction for semiconductor material. The influence of interface traps on SCM dC/dV data is still unclear. In this paper we report on the simulation work used to study the nature of SCM dC/dV data in the presence of interface traps. A technique to correctly simulate dC/dV of SCM measurement is then presented based on our justification. We also analyze how charge of interface traps surrounding SCM probe would affect SCM dC/dV due the small SCM probe dimension.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a case study examining the role of performance measurement systems in setting organizational ‘direction’. There is a growing concern in the existing literature to link the development of organizational ‘direction’ with performance measurement systems. Furthermore, the alignment between organizational ‘direction’, strategy and performance measurement is an area of increasing interest for both academics and practitioners. However, there is no adequate research recorded in the literature on the use of the performance measurement systems and the potential impact that performance measurement can have in setting the organizational ‘direction’. This study reports the findings of a case study from one of the leading academic institutions in the UK, the University of Warwick, presenting the main characteristics of its performance measurement system and attempting to explain the connection with setting the university’s ‘direction’.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To determine whether letter sequences and/or lens-presentation order should be randomized when measuring defocus curves and to assess the most appropriate criterion for calculating the subjective amplitude of accommodation (AoA) from defocus curves. SETTING: Eye Clinic, School of Life & Health Sciences, Aston University, Birmingham, United Kingdom. METHODS: Defocus curves (from +3.00 diopters [D] to -3.00 D in 0.50 D steps) for 6 possible combinations of randomized or nonrandomized letter sequences and/or lens-presentation order were measured in a random order in 20 presbyopic subjects. Subjective AoA was calculated from the defocus curves by curve fitting using various published criteria, and each was correlated to subjective push-up AoA. Objective AoA was measured for comparison of blur tolerance and pupil size. RESULTS: Randomization of lens-presentation order and/or letter sequences, or lack of, did not affect the measured defocus curves (P>.05, analysis of variance). The range of defocus that maintains highest achievable visual acuity (allowing for variability of repeated measurement) was better correlated to (r = 0.84) and agreed best with ( 0.50 D) subjective push-up AoA than any other relative or absolute acuity criterion used in previous studies. CONCLUSIONS: Nonrandomized letters and lens presentation on their own did not affect subjective AoA measured by defocus curves, although their combination should be avoided. Quantification of subjective AoA from defocus curves should be standardized to the range of defocus that maintains the best achievable visual acuity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long period gratings (LPGs) were written into a D-shaped single-mode fiber. These LPGs were subjected to a range of curvatures, and it was found that as curvature increased, there was increasingly strong coupling to certain higher order cladding modes without the usual splitting of the LPGs stopbands. A bend-induced stopband yielded a spectral sensitivity of 12.55 nm·m for curvature and 2.2×10-2 nm°C-1 for temperature. It was also found that the wavelength separation between adjacent bend-induced stopbands varied linearly as a function of curvature. Blue and red wavelength shifts of the stopbands were observed as the sensor was rotated around a fixed axis for a given curvature; thus, in principle, this sensor could be used to obtain bending and orientational information. The behavior of the stopbands was successfully modeled using a finite element approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the implementation of vector bending sensors using long-period gratings (LPGs) UV-inscribed in flat-clad, four-core and D-shaped fibres. Our experiments reveal a strong fibre-orientation dependence of the spectral response when such LPGs are subjected to dynamic bending, which provided an opportunity to realize curvature measurement with direction recognition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Long period gratings (LPGs) were written into a D-shaped single-mode fiber. These LPGs were subjected to a range of curvatures, and it was found that as curvature increased, there was increasingly strong coupling to certain higher order cladding modes without the usual splitting of the LPGs stopbands. A bend-induced stopband yielded a spectral sensitivity of 12.55 nm · m for curvature and 2.2 × 10-2 nm°C-1 for temperature. It was also found that the wavelength separation between adjacent bend-induced stopbands varied linearly as a function of curvature. Blue and red wavelength shifts of the stopbands were observed as the sensor was rotated around a fixed axis for a given curvature; thus, in principle, this sensor could be used to obtain bending and orientational information. The behavior of the stopbands was successfully modeled using a finite element approach.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

AIM: To determine the validity and reliability of the measurement of corneal curvature and non-invasive tear break-up time (NITBUT) measures using the Oculus Keratograph. METHOD: One hundred eyes of 100 patients had their corneal curvature assessed with the Keratograph and the Nidek ARKT TonorefII. NITBUT was then measured objectively with the Keratograph with Tear Film Scan software and subjectively with the Keeler Tearscope. The Keratograph measurements of corneal curvature and NITBUT were repeated to test reliability. The ocular sensitivity disease index questionnaire was completed to quantify ocular comfort. RESULTS: The Keratograph consistently measured significantly flatter corneal curvatures than the ARKT (MSE difference: +1.83±0.44D), but was repeatable (p>0.05). Keratograph NITBUT measurements were significantly lower than observation using the Tearscope (by 12.35±7.45s; pp < 0.001) and decreased on subsequent measurement (by -1.64 ± 6.03s; p < 0.01). The Keratograph measures the first time the tears break up anywhere on the cornea with 63% of subjects having NI-TBUT's <5s and a further 22% having readings between 5 and 10s. The Tearscope results were found to correlate better with the patients symptoms (r = -0.32) compared to the Keratograph (r = -0.19). Conclusions: The Keratograph requires a calibration off-set to be comparable to other keratometry devices. Its current software detects very early tear film changes, recording significantly lower NITBUT values than conventional subjective assessment. Adjustments to instrumentation software have the potential to enhance the value of Keratograph objective measures in clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rationale for carrying out this research was to address the clear lack of knowledge surrounding the measurement of public hospital performance in Ireland. The objectives of this research were to develop a comprehensive model for measuring hospital performance and using this model to measure the performance of public acute hospitals in Ireland in 2007. Having assessed the advantages and disadvantages of various measurement models the Data Envelopment Analysis (DEA) model was chosen for this research. DEA was initiated by Charnes, Cooper and Rhodes in 1978 and further developed by Fare et al. (1983) and Banker et al. (1984). The method used to choose relevant inputs and outputs to be included in the model followed that adopted by Casu et al. (2005) which included the use of focus groups. The main conclusions of the research are threefold. Firstly, it is clear that each stakeholder group has differing opinions on what constitutes good performance. It is therefore imperative that any performance measurement model would be designed within parameters that are clearly understood by any intended audience. Secondly, there is a lack of publicly available qualitative information in Ireland that inhibits detailed analysis of hospital performance. Thirdly, based on available qualitative and quantitative data the results indicated a high level of efficiency among the public acute hospitals in Ireland in their staffing and non pay costs, averaging 98.5%. As DEA scores are sensitive to the number of input and output variables as well as the size of the sample it should be borne in mind that a high level of efficiency could be as a result of using DEA with too many variables compared to the number of hospitals. No hospital was deemed to be scale efficient in any of the models even though the average scale efficiency for all of the hospitals was relatively high at 90.3%. Arising from this research the main recommendations would be that information on medical outcomes, survival rates and patient satisfaction should be made publicly available in Ireland; that despite a high average efficiency level that many individual hospitals need to focus on improving their technical and scale efficiencies, and that performance measurement models should be developed that would include more qualitative data.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Productivity at the macro level is a complex concept but also arguably the most appropriate measure of economic welfare. Currently, there is limited research available on the various approaches that can be used to measure it and especially on the relative accuracy of said approaches. This thesis has two main objectives: firstly, to detail some of the most common productivity measurement approaches and assess their accuracy under a number of conditions and secondly, to present an up-to-date application of productivity measurement and provide some guidance on selecting between sometimes conflicting productivity estimates. With regards to the first objective, the thesis provides a discussion on the issues specific to macro-level productivity measurement and on the strengths and weaknesses of the three main types of approaches available, namely index-number approaches (represented by Growth Accounting), non-parametric distance functions (DEA-based Malmquist indices) and parametric production functions (COLS- and SFA-based Malmquist indices). The accuracy of these approaches is assessed through simulation analysis, which provided some interesting findings. Probably the most important were that deterministic approaches are quite accurate even when the data is moderately noisy, that no approaches were accurate when noise was more extensive, that functional form misspecification has a severe negative effect in the accuracy of the parametric approaches and finally that increased volatility in inputs and prices from one period to the next adversely affects all approaches examined. The application was based on the EU KLEMS (2008) dataset and revealed that the different approaches do in fact result in different productivity change estimates, at least for some of the countries assessed. To assist researchers in selecting between conflicting estimates, a new, three step selection framework is proposed, based on findings of simulation analyses and established diagnostics/indicators. An application of this framework is also provided, based on the EU KLEMS dataset.