957 resultados para linearity


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The origin of nonlinearity in KTiOPO4 was investigated quantitatively from the chemical bond viewpoint. All constituent chemical bonds in this crystal were considered and their contributions to the total linearity and nonlinearity were quantitatively determined. Calculated results agree satisfactorily with experimental data in both signs and numerical values. These results show us that TiO6 groups and P(1)O-4 groups have relatively larger linear contributions and the nonlinearity derives from KOx (x=8,9) groups and P(2)O-4 groups. (C) 1997 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monensin was incorporated into phospholipid/alkanethiol bilayers on the gold electrode surface by a new, paint-freeze method to deposit a lipid monolayer on the self-assembled monolayers (SAMs) of alkanethiol. The advantages of this assembly system with a suitable function for investigating the ion selective transfer across the mimetic biomembrane are based on the characteristics of SAMs of alkanethiols and monensin. On the one hand, the SAMs of alkanethiols bring out their efficiency of packing and coverage of the metal substrate and relatively long-term stability; on the other hand, monensin improves the ion selectivity noticeably. The selectivity coefficients K-Na+,K-K+, K-Na+,K-Rb+ and K-Na+,K-Ag+ are 6 x 10(-2), 7.2 x 10(-3) and 30 respectively. However, the selectivity coefficient K-Na+,K-Li+ could not be obtained by a potentiometric method due to the specific interaction between Li+ and phospholipid and the lower degree of complexion between Li+ and monensin. The potential response of this bilayer system to monovalent ions is fairly good. For example, the slope of the response to Na+ is close to 60 mV per decade and its linearity range is from 10(-1) to 10(-5) M with a detection limit of 2 x 10(-6) M, The bilayer is stable for at least two months without changing its properties. This monensin incorporated lipid/alkanethiol bilayer is a good mimetic biomembrane system, which provides great promise for investigating the ion transfer mechanism across the biomembrane and developing a practical biosensor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Since the discovery of multiple bioactivities for agarobiose oligomers, a quantitative method has been in great need to monitor the agarobiose oligomers. This report demonstrates that agarobiose oligomers can be separated with high resolution in HPLC after introducing a-naphthylamine into compounds. Agarobiose oligomers ranged from biose to decaose were isolated by Sephadex column. HPLC analysis indicated that each oliomer could be quantified with good linearity and a low detection limit of 0.1-4 mug/ml. The chromatographic profiles of agaro-oligosaccharides with different hydrolysis modes (hydrochloride, citric acid, solid acid, and hydroxyl radical degradation) showed that agarobiose could be obtained more than 57.8% using solid acid mediated hydrolysis, while hydrochloride acid could degrade agar into a series of agaro-oligosaccharides from biose to decaose. The yield of oligosaccharides was low if hydrolyzed by citric acid. The Fenton degradation can increase the speed of hydrolysis, but the product was complex. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

数值模式是潮波研究的一种有利手段,但在研究中会面临各种具体问题,包括开边界条件的确定、底摩擦系数和耗散系数的选取等。数据同化是解决这些问题的一种途径,即利用有限数量的潮汐观测资料对潮波进行最优估计,其根本目的是迫使模型预报值逼近观测值,使模式不要偏离实际情况太远。本文采用了一种优化开边界方法,沿着数值模型的开边界优化潮汐水位信息,目的是设法使数值解在动力约束的意义下接近观测值,获得研究区域的潮汐结果。边界值由指定优化问题的解来定,以提高模拟区域的潮汐精度,最优问题的解是基于通过开边界的能量通量的变化,处理开边界处的观测值与计算值之差的最小化。这里提供了辐射型边界条件,由Reid 和Bodine(本文简称为RB)推导,我们将采用的优化后的RB方法(称为ORB)是优化开边界的特殊情况。 本文对理想矩形海域( E- E, N- N, 分辨率 )进行了潮波模拟,有东部开边界,模式采用ECOM3D模式。对数据结果的误差分析采用,振幅平均偏差,平均绝对偏差,平均相对误差和均方根偏差四个值来衡量模拟结果的好坏程度。 需要优化入开边界的解析潮汐值本文采用的解析解由方国洪《海湾的潮汐与潮流》(1966年)方法提供,为验证本文所做的解析解和方文的一致,本文做了其第一个例子的关键值a,b,z,结果与其结果吻合的相当好。但略有差别,分析的可能原因是两法在具体迭代方案和计算机保留小数上有区别造成微小误差。另外,我们取m=20,得到更精确的数值,我们发现对前十项的各项参数值,取m=10,m=20各项参数略有改进。当然我们可以获得m更大的各项参数值。 同时为了检验解析解的正确性讨论m和l变化对边界值的影响,结果指出,增大m,m=20时,u的模最大在本身u1或u2的模的6%;m=100时,u的模最大在本身u1或u2的模的4%;m再增大,m=1000时,u的模最大在本身u1或u2的模的4%,改变不大。当l<1时, =0处u的模最大为2。当l=1时, =0处u的模最大为0.1,当l>1时,l越大,u的模越小,当l=10时,u的模最大为0.001,可以认为为0。 为检验该优化方法的应用情况,我们对理想矩形区域进行模拟,首先将本文所采用的优化开边界方法应用于30m的情况,在开边界优化入开边界得出模式解,所得模拟结果与解析解吻合得相当好,该模式解和解析解在整个区域上,振幅平均绝对偏差为9.9cm,相位平均绝对偏差只有4.0 ,均方根偏差只有13.3cm,说明该优化方法在潮波模型中有效。 为验证该优化方法在各种条件下的模拟结果情况,在下面我们做了三类敏感性试验: 第一类试验:为证明在开边界上使用优化方法相比于没有采用优化方法的模拟解更接近于解析解,我们来比较ORB条件与RB条件的优劣,我们模拟用了两个不同的摩擦系数,k分别为:0,0.00006。 结果显示,针对不同摩擦系数,显示在开边界上使用ORB条件的解比使用RB条件的解无论是振幅还是相位都有显著改善,两个试验均方根偏差优化程度分别为84.3%,83.7%。说明在开边界上使用优化方法相比于没有采用优化方法的模拟解更接近于解析解,大大提高了模拟水平。上述的两个试验得出, k=0.00006优化结果比k=0的好。 第二类试验,使用ORB条件确定优化开边界情况下,在东西边界加入出入流的情况,流考虑线性和非线性情况,结果显示,加入流的情况,潮汐模拟的效果降低不少,流为1Sv的情况要比5Sv的情况均方根偏差相差20cm,而不加流的情况只有0.2cm。线性流和非线性流情况两者模式解相差不大,振幅,相位各项指数都相近, 说明流的线性与否对结果影响不大。 第三类试验,不仅在开边界使用ORB条件,在模式内部也使用ORB条件,比较了内部优化和不优化情况与解析解的偏差。结果显示,选用不同的k,振幅都能得到很好的模拟,而相位相对较差。另外,在内部优化的情况下,考虑不同的k的模式解, 我们选用了与解析解相近的6个模式解的k,结果显示,不同的k,振幅都能得到很好的模拟,而相位较差。 总之,在开边界使用ORB条件比使用RB条件好,振幅相位都有大幅度改进,在加入出入流情况下,流的大小对模拟结果有影响,但线形流和非线性流差别不大。内部优化的结果显示,模式采用不同的k都能很好模拟解析解的振幅。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two methods for tetrodotoxin analysis using liquid chromatography coupled with electrospray iontrap mass spectrometry (LC-ESI-MS) have been established with C,, reversed phase column and hydrophilic interaction liquid chromatography (HILIC) column, respectively. Sensitivity and reproducibility of the methods were compared. The method using C-18 column in selected ion monitoring (SIM) mode had a detection limit (S/N = 3) of 120 pg, and a good linearity of the calibration curve was obtained for tetrodotoxin (r = 0. 9992). High reproducibility of the method was observed, with a relative standard deviation (RSD) below 10%. The method using HILIC column in SIM mode and selected reaction monitoring (SRM) mode had detection limits (S/N = 3) of 15 and 3.75 pg, respectively. Good linearity of the calibration curves was obtained for tetrodotoxin (r = 0. 9996 and 0. 9998 in SIM and SRM mode, respectively). T he reproducibility was high in SIM mode but relatively poor in SRM mode. Based on the results, the method using HILIC column in SIM mode was suggested for the analysis of tetrodotoxin with LC-MS system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The hyphenated technique of high performance liquid chromatography coupled with inductively coupled plasma mass spectrometry(HPLC-ICP-MS) was applied to the simultaneous determination of five organotin compounds in the shellfish samples. Agilent TC-C-18 column was selected, mobile phase of the HPLC was CH3CN:H2O: CH3COOH = 65:23:12 (V/V), 0. 05% TEA, pH = 3.0 at flow rate 0.4 mL/min. Five mixed organotin standards from 100 mu g/L to 0. 5 mu g/L was used for the method evaluation. The experimental results indicate that the linearity (R-2) for each compound was over 0.998. The shellfish samples were treated by supersonic extraction with mobile phase for 30min. Four organotin compounds including dibutyltin (DBT), tributyltin (TBT), diphenyltin (DphT) and triphenyltin (TPhT) in shellfish samples were detected with method mentioned above. It was found that the domain compounds in the samples were tributyltin (TBT) and triphenyltin (TPhT). The recoveries test from the standard addition for trimethyltin (TMT tributyltin (TBT), and triphenyltin (TPhT) were, over 80%. However, the recoveries for diphenyltin (DPhT) and dibutyltin (DBT) were relatively low, 37.3% and 75.2% respectively. The reason might be attributed to the decomposition of those compounds during the extraction procedure. The further study on this subject is under the progress.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A capillary electrophoresis (CE) method has been developed for the determination of six bioactive flavonoids that are commonly found in health foods: hesperidin, hyperin, isorhamnetin, kaempferol, quercetin and rutin. The effects of several parameters, such as pH, buffer concentration, separation voltage and UV detector wavelength, were investigated to find the optimal conditions. Using a HbBCh-NaiB-iO? buffer (pH 9.2), the analytes can be separated within 8 min. The relative standard deviations of migration times in eight injections were between 0.77% and 0.93%, and those of the peak areas ranged from 3.8% to 8.6%. A high reproducibility and excellent linearity was observed over two orders of magnitude, with detection limits (S/N = 3) ranging from 0.34ug ml to 2.9ug ml for all the six analytes. Recoveries ranged from 80.4 % to 113.9 %. The new method is simple, reproducible and sensitive. No solid phase extraction for sample pretreatment is necessary. Analysis results are accurate in application to bee pollens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple and sensitive method for the determination of free fatty acids (FFAs) using acridone-9-ethyl-p-toluenesulfonate (AETS) as a fluorescence derivatization reagent by high performance liquid chromatography (HPLC) has been developed. Free fatty acid derivatives were separated on an Eclipse XDB-C-8 column with a good baseline resolution and detected with the fluorescence of which excitation and emission wavelengths of derivatives were set at lambda(ex) 404 and lambda(em) 440 nm, respectively. Identification of 19 fatty acid derivatives was carried out by online post-column mass spectrometry with an atmospheric pressure chemical ionization (APCI) source under positive-ion detection mode. Nineteen FFAs from the extract of Lomatogonium rotatum are sensitively determined. The results indicate that the plant Lomatogonium rotatum is enriched with an abundance of FFAs and FFAs of higher contents, which mainly focus on even carbon atoms, C-14, C-16, and C-18. The validation of the method including linearity, repeatability, and detection limits was examined. Most linear correlation coefficients for fatty acid derivatives are > 0.9989, and detection limits (at signal-to-noise of 3: 1) are 12.3-43.7 fmol. The relative standard deviations (RSDs) of the peak areas and retention times for 19 FFAs standards are < 2.24% and 0.45%, respectively. The established method is rapid and reproducible for the separation determination of FFAs from the extract of Lomatogonium rotatum with satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A rapid and sensitive liquid chromatography-atmospheric pressure chemical ionization mass spectrometry (HPLC-APCI-MS) assay for the determination of five pharmacologically active compounds (PAC) extracted from the traditional Chinese medicine, Rhodiola , namely salidroside, tyrosol, rhodionin, gallic acid, and ethyl gallate has been developed. In this method, PAC could be baseline separated and detected with DAD at 275 nm. The validation of the method, including sensitivity, linearity, repeatability, and recovery, was examined. The linear calibration curves were acquired with correlation coefficient >0.999 and the limits of detection LOD (at a signal-to-noise ratio=3:1) were between 0.058 and 1.500 mu mol/L. It was found, that the amounts of PAC varied with different species of Rhodiola . The established method is rapid and reproducible for the separation of five natural pharmacologically active compounds from extracts of Rhodiola with satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

介绍了一种基于多线阵像机构成的视觉空间定位系统.该系统利用线阵像机的快速性与高分辨率的特点,采用了非平行空间投影面相交定位的基本原理,利用几何投影关系定位求解的方法,实现了多线阵像机视觉系统的空间定位.并提出了多线阵像机的神经网络非线性修正方法,使修正后的PSD能在较宽的位置范围内输出高线性度的信号.实验结果表明,基于非线性修正的多线阵像机位姿测量系统简化了立体视觉空间定位计算的复杂性,在定位精度、定位范围和采样速度上均达到了良好效果.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PSD是一种高分辨率、实时性好的光电位置敏感器件,因而具有广泛应用的前景.但在光照度变化条件下,输出信号存在非线性飘移,因而影响了作为位置检测传感器的检测精度,尤其在3D测量时适用性受到了限制.针对这个问题,提出了一种PSD位置传感器的非线性误差补偿方法.该方法针对目标的空间距离变化所产生的PSD输出非线性飘移,采用归一化模型进行误差修正,很大程度上改进了PSD的输出一致性,使基于PSD的3D测量系统性能得以提高.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

研制了一种有重力约束的三索控制的柔索吊床机构来模拟船体海面上的运动。为了解三柔索吊床机构的运动特性 ,对其进行了运动学建模与仿真。仿真结果表明 ,台面倾角在 0°~ 30 0°变化时 ,台面不碰撞立柱 ,且柔索伸缩长度与台面倾斜角度接近于线性变化。本文所做的工作对吊床平台避免撞击立柱、缩小吊床立柱布置空间、提高空间利用率 ,以及为吊床的运动控制提供了理论依据

Relevância:

10.00% 10.00%

Publicador:

Resumo:

针对母船的升沉运动影响有缆水下机器人的释放与回收的工程实际需求,提出了利用液压绞车降低中继器的升沉速度来实现水下机器人主动升沉补偿控制的方法,来提高水下机器人释放与回收的安全性能。建立液压绞车的数学模型并设计主动升沉补偿前馈控制器。水下机器人主动升沉补偿实验表明液压系统的非线性降低了液压绞车主动升沉补偿前馈控制的升沉补偿效率。针对液压绞车的非线性特性,设计了液压绞车主动升沉补偿预测控制算法,仿真实验表明基于液压系统参数辨识的液压绞车主动升沉补偿预测控制可以得到较高的升沉补偿效率。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

谐波传动有很多优点,在机器人驱动中经常被使用.但谐波传动也有一些缺点,如柔性等因素影响负载端轨迹跟踪精度.本文系统地分析了谐波传动系统的动力学特性,建立了包括电机转子惯量在内的动力学模型,疽对系统进行全面实验研究的基础上总结出谐波传动系统中存在的问题,采用相应的基于传感器的控制策略克服存在的问题,提高系统的响应性能.从理论分析和实验结果证实了提出方法的可行性。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

利用高精度三坐标测量机扫描功能,充分获得焊接板材端面线性三维数据坐标值,采用基于最小二乘法而建立的理想直线数学模型来评定直线度误差,并与实际采用塞尺法进行对比,结果发现采用三坐标测量更能详尽地反应整个焊接边缘直线度真实情况,节省大量的数据处理时间,且数据更加准确可靠,并在实际激光焊接中获得良好激光焊缝,同时直观地给出了焊接板材边缘线性特征,为剪板机刀具调整提供了方向与位置。