587 resultados para endovascular treament
Resumo:
Purpose. The present report describes a full endovascular treatment of a multiple anomalous (Splenic artery aneurysms) SAA with combination of coils embolization and proximal occlusion of the splenic artery with the Amplatzer vascular plug. Case report. A 53-year-old Jehovah witness woman presented with multiple aneurysms arising from an anomalous splenic artery. An endovascular treatment was performed by implantation of multiple coils and an Amplatzer Vascular Plug. A CT scan 2 months after the procedure showed complete thrombosis of the aneurysms. Discussion. Aneurysms involving an anomalous or aberrant splenic artery are rarely reported in the literature. Their surgical treatment involves potential difficulties as a consequence of anatomical position and vascular anomalies. A fully endovascular technique can be much more attractive compared to any surgical management, providing an effective and minimally invasive option. Splenic artery - Aberrant splenic artery - Aneurysm - Endovascular treatment - Jehovah witness.
Resumo:
Carotid artery dissection (CAD) is a major cause of stroke in those under age 45, accounting for around 20% of ischaemic events[1,2]. In the absence of known connective tissue disorders, most dissections are traumatic[2]. First-line management is comprised of antiplatelet or anticoagulation therapy, but many traumatic dissections progress despite this and carry the risk of long-term complications from embolism or stenosis[3]. We report a case of traumatic bilateral carotid dissection leading to progressive neurological symptoms and hypoperfusion on computed tomography perfusion (CTP), despite escalation in anticoagulation, which led to emergency carotid stenting.
Resumo:
Magnesium alloys have been widely explored as potential biomaterials, but several limitations to using these materials have prevented their widespread use, such as uncontrollable degradation kinetics which alter their mechanical properties. In an attempt to further the applicability of magnesium and its alloys for biomedical purposes, two novel magnesium alloys Mg-Zn-Cu and Mg-Zn-Se were developed with the expectation of improving upon the unfavorable qualities shown by similar magnesium based materials that have previously been explored. The overall performance of these novel magnesium alloys has been assessesed in three distinct phases of research: 1) analysing the mechanical properties of the as-cast magnesium alloys, 2) evaluating the biocompatibility of the as-cast magnesium alloys through the use of in-vitro cellular studies, and 3) profiling the degradation kinetics of the as-cast magnesium alloys through the use of electrochemical potentiodynamic polarization techqnique as well as gravimetric weight-loss methods. As compared to currently available shape memory alloys and degradable as-cast alloys, these experimental alloys possess superior as-cast mechanical properties with elongation at failure values of 12% and 13% for the Mg-Zn-Se and Mg-Zn-Se alloys, respectively. This is substantially higher than other as-cast magnesium alloys that have elongation at failure values that range from 7-10%. Biocompatibility tests revealed that both the Mg-Zn-Se and Mg-Zn-Cu alloys exhibit low cytotoxicity levels which are suitable for biomaterial applications. Gravimetric and electrochemical testing was indicative of the weight loss and initial corrosion behavior of the alloys once immersed within a simulated body fluid. The development of these novel as-cast magnesium alloys provide an advancement to the field of degradable metallic materials, while experimental results indicate their potential as cost-effective medical devices.
Resumo:
Objectives CO2-EVAR was proposed for treatment of AAA especially in patients with CKD. Issues regarding standardization, such as visualization of lowest renal artery (LoRA) and quality image in angiographies performed from pigtail or introducer-sheath, are still unsolved. Aim of the study was to analyze different steps of CO2-EVAR to create an operative protocol to standardize the procedure. Methods Patients undergoing CO2-EVAR were prospectively enrolled in 5 European centers (2018-2021). CO2-EVAR was performed using an automated injector. LoRA visualization and image quality (1-4) were analyzed and compared at different procedure steps: preoperative CO2-angiography from Pigtail/Introducer-sheath (1st Step), angiographies from Pigtail at 0%,50%,100% main body (MB) deployment (2nd Step), contralateral hypogastric artery (CHA) visualization with CO2 injection from femoral Introducer-sheath (3rd Step) and completion angiogram from Pigtail/Introducer-sheath (4th Step). Intra-/postoperative adverse events were evaluated. Results Sixty-five patients undergoing CO2-EVAR were enrolled, 55/65(84.5%) male, median age 75(11.5) years. Median ICM was 20(54)cc; 19/65(29.2%) procedures were performed with 0-iodine. 1st Step: median image quality was significantly higher with CO2 injected from femoral introducer [Pigtail2(3)vs.3(3)Introducer,p=.008]. 2nd Step: LoRA was more frequently detected at 50% (93%vs.73.2%, p=.002) and 100% (94.1%vs.78.4%, p=.01) of MB deployment compared with first angiography from Pigtail; image quality was significantly higher at 50% [3(3)vs.2(3),p=<.001] and 100% [4(3) vs.2(3),p=.001] of MB deployment. CHA was detected in 93% cases (3rd Step). Mean image quality was significantly higher when final angiogram (4th Step) was performed from introducer (Pigtail2.6±1.1vs.3.1±0.9Introducer,p=<.001). Rates of intra-/postoperative adverse events (pain,vomit,diarrhea) were 7.7% and 12.5%. Conclusions Preimplant CO2-angiography should be performed from Introducer-sheath. MB steric bulk during its deployment should be used to improve image quality and LoRA visualization with CO2. CHA can be satisfactorily visualized with CO2. Completion CO2-angiogram should be performed from femoral Introducer-sheath. This operative protocol allows to perform CO2-EVAR with minimal ICM and low rate of mild complications.
Resumo:
INTRODUCTION Endograft deployment is a well-known cause of arterial stiffness increase as well as arterial stiffness increase represent a recognized cardiovascular risk factor. A harmful effect on cardiac function induced by the endograft deployment should be investigated. Aim of this study was to evaluate the impact of endograft deployment on the arterial stiffness and cardiac geometry of patients treated for aortic aneurysm in order to detect modifications that could justify an increased cardiac mortality at follow-up. MATHERIALS AND METHODS Over a period of 3 years, patients undergoing elective EVAR for infrarenal aortic pathologies in two university centers in Emilia Romagna were examined. All patients underwent pre-operative and six-months post-operative Pulse Wave Velocity (PWV) examination using an ultrasound-based method performed by vascular surgeons together with trans-thoracic echocardiography examination in order to evaluate cardiac chambers geometry before and after the treatment. RESULTS 69 patients were enrolled. After 36 months, 36 patients (52%) completed the 6 months follow-up examination.The ultrasound-based carotid-femoral PWV measurements performed preoperatively and 6 months after the procedure revealed a significant postoperative increase of cf-PWV (11,6±3,6 m/sec vs 12,3±8 m/sec; p.value:0,037).Postoperative LVtdV (90±28,3 ml/m2 vs 99,1±29,7 ml/m2; p.value:0.031) LVtdVi (47,4±15,9 ml/m2 vs 51,9±14,9 ml/m2; p.value:0.050), IVStd (12±1,5 mm vs 12,1±1,3 mm; p.value:0,027) were significantly increased if compared with preoperative measures.Postoperative E/A (0,76±0,26 vs 0,6±0,67; p.value:0,011), E’ lateral (9,5±2,6 vs 7,9±2,6; p.value:0,024) and A’ septal (10,8±1,5 vs 8,9±2; p.value0,005) were significantly reduced if compared with preoperative measurements CONCLUSION The endovascular treatment of the abdominal aorta causes an immediate and significant increase of the aortic stiffness.This increase reflects negatively on patients’ cardiac geometry inducing left ventricle hypertrophy and mild diastolic disfunction after just 6 months from endograft’s implantation.Further investigations and long-term results are necessary to access if this negative remodeling could affect the cardiac outcome of patient treated using the endovascular approach.
Resumo:
Abdominal aortic aneurysm is the pathological dilation of the abdominal tract of the aorta and, if left untreated, could undergo rupture with a mortality rate of up to 90%. EVAR is the most common method for AAA treatment consisting in the internal coverage of the aorta with a metallic stent to isolate the aneurysmatic segment from the systemic circulation. Although EVAR technical success rate is high, reinterventions are common. Among the causes of reinterventions typeII endoleaks are the most frequent and consist in retrograde blood flow into the aneurysmal sac from collateral aortic branches. Continued perfusion of the aneurysm sac may lead to aneurysm rupture, therefore AAA sac embolization is performed using metallic coils. However, the presence of artifacts caused by the presence of metallic coils is a limitation because they are radiopaque and can hamper the endoleak during imaging follow-up. This study is aimed at developing a biocompatible hydrogel that could be injected into the aneurysmal sac and may allow a selective intraprocedural sac embolization to reduce post procedural typeII endoleak and eventual AAA rupture. P(BT75BSI25) was synthesized by polycondensation and its biocompatibility tested to assess whether the polymers had no toxic effects. HUVEC cell line was used to mimic the environment in which the polymer would be in contact with, PBS was used as a positive control and MTT assay was performed to evaluate cellular viability after being in contact with the hydrogel. MTT assay showed no significant difference between PBS and P(BT75BSI25), thus the polymer is biocompatible, as confirmed by the analysis of apoptosis by flow cytometry. An aromatic copolymer was obtained via polycondensation and was found to be biocompatible in contact with endothelial cells. This suggests that the hydrogel could be potentially used in the clinical setting for the treatment of type II endoleak after EVAR.
Saphenous vein graft bypass in the treatment of giant cavernous sinus aneurysms: report of two cases
Resumo:
Two cases of giant intracavernous aneurysms treated by high flow bypass with saphenous vein graft between the external carotid artery (ECA) and branches of the middle cerebral artery (MCA) are presented. Very often these aneurysms are unclippable because they are fusiform or have a large neck. Occlusion of the internal carotid artery (ICA) is the treatment of choice in many cases. This procedure has however a high risk of brain infarction. Revascularization of the brain by extra-intracranial anastomosis between the superficial temporal artery (STA) and branches of the MCA is frequently performed. This procedure provides however a low flow bypass and brain infarction may occur. We report two cases of giant cavernous sinus aneurysms treated by high flow bypass and endovascular balloon occlusion of the ICA. Immediate high flow revascularization of MCA branches was achieved and the patients showed no ischemic events. Follow-up of 8 and 14 months after operation shows patency of the venous graft and no neurological deficits. Angiographic control examination showed complete aneurysm occlusion in both cases.
Resumo:
OBJETIVO: Avaliar as características demográficas e de imagens da trombose endoluminal em uma série de pacientes submetidos a tratamento endovascular do aneurisma de aorta abdominal (TEAAA). MÉTODOS: Avaliamos as características de imagem que permitiram o diagnóstico da trombose endoluminal em uma série de 30 pacientes submetidos ao TEAAA, com seguimento de 5 a 29 meses, através de exames de tomografia computadorizada multidetectores (TCMD) de 64 canais. RESULTADOS: Foram diagnosticados dez casos de trombose luminal (33,3%), sendo que em três pacientes a trombose foi total de um ramo ilíaco. CONCLUSÃO: A TCMD permitiu o diagnóstico de diferentes tipos de trombose endoluminal em pacientes submetidos ao TEAAA. O uso desta modalidade diagnóstica minimamente invasiva deverá ser encorajado na prática clínica.
Resumo:
Purpose The purpose of this study was to describe the preliminary results of prophylactic temporary balloon occlusion of the internal iliac arteries for bleeding control in patients with placenta accreta during cesarean hysterectomy. Methods From May 2006 to March 2010, 21 patients diagnosed with placenta accreta using ultrasound and/or magnetic resonance imaging were submitted to prophylactic balloon occlusion before hysterectomy. Fluoroscopy, balloon occlusion time, surgical duration, intraoperative blood loss, transfusion volume, and procedure complications were analyzed. Results The mean age was 30.5 years with a mean of 3.6 previous gestations. Imaging studies revealed that all patients had placenta accreta and all were submitted to cesarean hysterectomy. One hysterectomy was due to previous diagnosis of fetal death and another due to cesarean with uterine curettage. Mean fluoroscopy time was 7.5 min, balloon occlusion time was 164 min, and surgery duration was 260 min. Estimated blood loss was 1,671.5 ml with mean reposition fluids of 3,538 ml of crystalloids, 309.5 ml of colloids, and 1.24 ml of packed red blood cells. Two patients were submitted to thromboembolectomy due to prolonged surgical time. There was no maternal or fetal mortality related to the procedure. Conclusions The results demonstrated that prophylactic balloon occlusion of internal iliac artery is a safe method and appears to reduce blood loss and transfusion requirements in patients diagnosed with placenta accreta who undergo cesarean hysterectomy. Antenatal imaging diagnosis of placenta accreta enables preoperative planning.
Resumo:
Entrapment of guidewires by inferior vena cava filters can occur during the blind insertion of a jugular or a subclavian central venous catheter. Recently, few case reports have been published in the radiology literature. In addition, others have described endovascular techniques aimed at removing entrapped guidewires, avoiding the possibility of vena cava rupture. Given that a temporary hemodialysis venous catheter is frequently used as a first access, the possibility of entrapping the dialysis catheter guidewire should not be neglected.
Resumo:
Objective: To describe bypass to perigeniculate vessels for limb salvage. Design: Retrospective cohort study. Material and methods: Between 1995 and 2009, 47 bypass procedures to perigeniculate collateral arteries were performed in 46 patients (15 women, 31 men; median age, 68 years). All patients presented with critical ischaemia (tissue loss in 87.5%, rest pain in 12.5%). Mean ankle brachial index was 0.27 +/- 0.17. The site of distal anastomosis was the descending genicular artery (DGA) in 23 bypasses (1 bilateral) and the medial sural artery (MSA) in 24. Proximal anastomosis was to the external iliac artery in 2 cases, common femoral artery in 23 cases, superficial femoral artery in 8 cases, deep femoral artery in 8 cases, above-knee poplitaeal artery in 2 cases, and previous graft in 4 cases. Results: There were four deaths during the immediate postoperative period. Mean follow-up duration was 27 months. Ten patients required major amputation. Mean ankle brachial index post-operatively was 0.60 +/- 0.21. At 3 years, primary patency was 74.7 +/- 7%, secondary patency was 83.4 +/- 8%, and the limb salvage and survival rates were 73.5 +/- 7% and 77.4 +/- 7%, respectively. Conclusion: Bypass to perigeniculate arteries is a viable treatment option for critical limb ischaemia in selected patients. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.
Resumo:
Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584
Resumo:
This paper has the objective to evaluate retrospectively the long-term results of transhepatic treatment of PV stenoses after pediatric LT. During an eight-yr period, 15 children with PV stenoses underwent PTA with balloon dilation or stent placement in case of PTA failure after LT. Patients` body weights ranged from 9.3 to 46 kg (mean, 15.5 kg). PV patency was evaluated in the balloon dilation and in the stent placement groups. Technical and clinical successes were achieved in all cases with no complication. Eleven patients (11/15; 73.3%) were successfully treated by single balloon dilation. Four patients (4/15; 26.7%) needed stent placement. One patient was submitted to stent placement during the same procedure because of PTA failure. The other three developed clinical signs of portal hypertension because of PV restenoses two, eight, and twenty-eight months after the first PTA. They had to be submitted to a new procedure with stent placement. The follow-up time ranged from 3 to 8.1 yr (mean, 6.3 yr). In conclusion, transhepatic treatment of PV stenoses after pediatric LT with balloon dilation or stent placement demonstrated to be a safe and effective treatment that results in long-term patency.
Resumo:
PEComas are rare neoplasms that are sometimes associated with the tuberous sclerosis complex. They typically contain perivascular epithelioid cells that coexpress muscle and melanocytic markers. However, apart from these classical features, considerable clinical, pathologic, and immunohistochemical variation has been reported. WT1, the Wilms tumor gene product, can be expressed in various tumors from different anatomical sites, including sex-cord and other ovarian tumors with a sertoliform pattern. Neither a sex-cord like pattern nor WT1 expression has been described in PEComas. Here, we describe a case of uterine PEComa with a pattern of infiltration into the myometrium that is similar to stromal sarcomas, characterized by tongues and endovascular growing. The architecture and cellular morphology were similar to sex-cord tumors, and the PEComa was diffusely and strongly positive for WT1. We reviewed, from our files, an additional 9 cases of PEComa from different sites, and found WT1 expression in one more soft tissue tumor. We discuss the relationship between PEComas and other uterine sarcomas. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
OBJECTIVE: We report our results using Onyx HD-500 (Micro Therapeutics, Inc., Irvine, CA) in the endovascular treatment of wide-neck intracranial aneurysms, which have a high rate of incomplete occlusion and recanalization with platinum coils. METHODS: Sixty-nine patients with 84 aneurysms were treated. Most of the aneurysms were located in the anterior circulation (80 of 84 aneurysms), were unruptured (74 of 84 aneurysms), and were incidental. Ten presented with subarachnoid hemorrhage, and 15 were symptomatic. All aneurysms had wide necks (neck >4 mm and/or dome-to-neck ratio <1.5). Fifty aneurysms were small (<12 mm), 30 were large (12 to <25 mm) and 4 were giant. Angiographic follow-up was available for 65 of the 84 aneurysms at 6 months, for 31 of the 84 aneurysms at 18 months, and for 5 of the 84 aneurysms at 36 months. RESULTS: Complete aneurysm occlusion was seen in 65.5% of aneurysms on immediate control, in 84.6% at 6 months, and in 90.3% at 18 months. The rates of complete occlusion were 74%, 95.1%, and 95.2% for small aneurysms and 53.3%, 70%, and 80% for large aneurysms at the same follow-up periods. Progression from incomplete to complete occlusion was seen in 68.2% of all aneurysms, with a higher percentage in small aneurysms (90.9%). Aneurysm recanalization was observed in 3 patients (4.6%), with retreatment in 2 patients (3.3%). Procedural mortality was 2.9%. Overall morbidity was 7.2%. CONCLUSION: Onyx embolization of intracranial wide-neck aneurysms is safe and effective. Morbidity and mortality rates are similar to those of other current endovascular techniques. Larger samples and longer follow-up periods are necessary.