967 resultados para bloqueio femoral


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION Stable reconstruction of proximal femoral (PF) fractures is especially challenging due to the peculiarity of the injury patterns and the high load-bearing requirement. Since its introduction in 2007, the PF-locking compression plate (LCP) 4.5/5.0 has improved osteosynthesis for intertrochanteric and subtrochanteric fractures of the femur. This study reports our early results with this implant. METHODS Between January 2008 and June 2010, 19 of 52 patients (12 males, 7 females; mean age 59 years, range 19-96 years) presenting with fractures of the trochanteric region were treated at the authors' level 1 trauma centre with open reduction and internal fixation using PF-LCP. Postoperatively, partial weight bearing was allowed for all 19 patients. Follow-up included a thorough clinical and radiological evaluation at 1.5, 3, 6, 12, 24, 36 and 48 months. Failure analysis was based on conventional radiological and clinical assessment regarding the type of fracture, postoperative repositioning, secondary fracture dislocation in relation to the fracture constellation and postoperative clinical function (Merle d'Aubigné score). RESULTS In 18 patients surgery achieved adequate reduction and stable fixation without intra-operative complications. In one patient an ad latus displacement was observed on postoperative X-rays. At the third month follow-up four patients presented with secondary varus collapse and at the sixth month follow-up two patients had 'cut-outs' of the proximal fragment, with one patient having implant failure due to a broken proximal screw. Revision surgeries were performed in eight patients, one patient receiving a change of one screw, three patients undergoing reosteosynthesis with implantation of a condylar plate and one patient undergoing hardware removal with secondary implantation of a total hip prosthesis. Eight patients suffered from persistent trochanteric pain and three patients underwent hardware removal. CONCLUSIONS Early results for PF-LCP osteosynthesis show major complications in 7 of 19 patients requiring reosteosynthesis or prosthesis implantation due to secondary loss of reduction or hardware removal. Further studies are required to evaluate the limitations of this device.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the ability of dual energy X-rays absorptiometry (DXA) areal bone mineral density (aBMD) measured in different regions of the proximal part of the human femur for predicting the mechanical properties of matched proximal femora tested in two different loading configurations. 36 pairs of fresh frozen femora were DXA scanned and tested until failure in two loading configurations: a fall on the side or a one-legged standing. The ability of the DXA output from four different regions of the proximal femur in predicting the femoral mechanical properties was measured and compared for the two loading scenarios. The femoral neck DXA BMD was best correlated to the femoral ultimate force for both configurations and predicted significantly better femoral failure load (R2=0.80 vs. R2=0.66, P<0.05) when simulating a side than when simulating a standing configuration. Conversely, the work to failure was predicted similarly for both loading configurations (R2=0.54 vs. R2=0.53, P>0.05). Therefore, neck BMD should be considered as one of the key factors for discriminating femoral fracture risk in vivo. Moreover, the better predictive ability of neck BMD for femoral strength if tested in a fall compared to a one-legged stance configuration suggests that DXA's clinical relevance may not be as high for spontaneous femoral fractures than for fractures associated to a fall.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One Arabian and 5 Hungarian half-bred horses were used to study the macroscopic and microscopic survival of autologous osteochondral grafts in the weight-bearing surface of the medial femoral condyle (MFC). Grafts were harvested from the cranial surface of the medial femoral trochlea (MFT) under arthroscopic control. Three of them were transplanted into the weight-bearing surface of the contralateral MFC using an arthrotomy approach. Three months later this transplantation procedure was repeated on the opposite stifle joints in the same animals, but at that time transplantation was performed arthroscopically. Follow-up arthroscopy was carried out 12 months after the first operations, and biopsies were taken from both the recipient and the donor sites for histological examination. During follow-up arthroscopy, the transplanted areas looked congruent and smooth. Microscopically, the characteristics of hyaline cartilage were present in 5 out of the 10 biopsies examined; however, in the other half of biopsies glycosaminoglycan (GAG) loss and change in the architecture of the transplanted cartilage was observed. In a 16-year-old horse, all grafts broke during harvesting, and thus transplantation was not performed. No radiological signs of osteoarthritic changes were detected 9 to 12 months after the operations in the donor and recipient joints. Clinically, no lameness or effusion was present three months after the transplantations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Discrepancies in finite-element model predictions of bone strength may be attributed to the simplified modeling of bone as an isotropic structure due to the resolution limitations of clinical-level Computed Tomography (CT) data. The aim of this study is to calculate the preferential orientations of bone (the principal directions) and the extent to which bone is deposited more in one direction compared to another (degree of anisotropy). Using 100 femoral trabecular samples, the principal directions and degree of anisotropy were calculated with a Gradient Structure Tensor (GST) and a Sobel Structure Tensor (SST) using clinical-level CT. The results were compared against those calculated with the gold standard Mean-Intercept-Length (MIL) fabric tensor using micro-CT. There was no significant difference between the GST and SST in the calculation of the main principal direction (median error=28°), and the error was inversely correlated to the degree of transverse isotropy (r=−0.34, p<0.01). The degree of anisotropy measured using the structure tensors was weakly correlated with the MIL-based measurements (r=0.2, p<0.001). Combining the principal directions with the degree of anisotropy resulted in a significant increase in the correlation of the tensor distributions (r=0.79, p<0.001). Both structure tensors were robust against simulated noise, kernel sizes, and bone volume fraction. We recommend the use of the GST because of its computational efficiency and ease of implementation. This methodology has the promise to predict the structural anisotropy of bone in areas with a high degree of anisotropy, and may improve the in vivo characterization of bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The sheep is a popular animal model for human biomechanical research involving invasive surgery on the hind limb. These painful procedures can only be ethically justified with the application of adequate analgesia protocols. Regional anaesthesia as an adjunct to general anaesthesia may markedly improve well-being of these experimental animals during the postoperative period due to a higher analgesic efficacy when compared with systemic drugs, and may therefore reduce stress and consequently the severity of such studies. As a first step 14 sheep cadavers were used to establish a new technique for the peripheral blockade of the sciatic and the femoral nerves under sonographic guidance and to evaluate the success rate by determination of the colorization of both nerves after an injection of 0.5 mL of a 0.1% methylene blue solution. First, both nerves were visualized sonographically. Then, methylene blue solution was injected and subsequently the length of colorization was measured by gross anatomical dissection of the target nerves. Twenty-four sciatic nerves were identified sonographically in 12 out of 13 cadavers. In one animal, the nerve could not be ascertained unequivocally and, consequently, nerve colorization failed. Twenty femoral nerves were located by ultrasound in 10 out of 13 cadavers. In three cadavers, signs of autolysis impeded the scan. This study provides a detailed anatomical description of the localization of the sciatic and the femoral nerves and presents an effective and safe yet simple and rapid technique for performing peripheral nerve blocks with a high success rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction This prospective nonrandomized study compared the safety and efficacy of a novel arterial closure device (ACD) in common femoral artery procedures to that of the FDA submitted historical manual pressure control group, who underwent either a diagnostic angiogram (DA) or a percutaneous coronary intervention (PCI) procedure. Methods and Results A total of 55 patients were enrolled in this study of the novel ACD. Of the 55 patients, 39 were enrolled in the DA group and 16 were enrolled in the PCI group. Six patients were excluded. A device was deployed in 49 patients. Time to hemostasis (TTH), time to ambulation (TTA), device function, and device-related vascular complications were measured. In the device group, the TTH for the combined DA and PCI patients was 32 seconds (0.54 ± 0.93 minutes), significantly lower when compared with 16.0 ± 12.2 minutes (P < 0.0001) for the control group. Overall major vascular complication rate did not differ significantly, device group (1/49) and the historical control group (1/217). TTA in the combined PCI and DA device group was 226.4 ± 231.9 at the German site (site ambulation policy). In the Irish site, the average TTA in the PCI group was 187 minutes (n = 8) and 85 minutes (n = 14) in the DA group. Conclusion The Celt ACD® device is safe, effective, and significantly decreases the TTH compared to manual pressure and has a low vascular complications rate. The device may be effective in early ambulation and discharge of patients postcoronary intervention procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Renal failure after thoracoabdominal aortic repair is a significant clinical problem. Distal aortic perfusion for organ and spinal cord protection requires cannulation of the left femoral artery. In 2006, we reported the finding that direct cannulation led to leg ischemia in some patients and was associated with increased renal failure. After this finding, we modified our perfusion technique to eliminate leg ischemia from cannulation. In this article, we present the effects of this change on postoperative renal function. METHODS: Between February 1991 and July 2008, we repaired 1464 thoracoabdominal aortic aneurysms. Distal aortic perfusion was used in 1088, and these were studied. Median patient age was 68 years, and 378 (35%) were women. In September 2006, we began to adopt a sidearm femoral cannulation technique that provides distal aortic perfusion while maintaining downstream flow to the leg. This was used in 167 patients (15%). We measured the joint effects of preoperative glomerular filtration rate (GFR) and cannulation technique on the highest postoperative creatinine level, postoperative renal failure, and death. Analysis was by multiple linear or logistic regression with interaction. RESULTS: The preoperative GFR was the strongest predictor of postoperative renal dysfunction and death. No significant main effects of sidearm cannulation were noted. For peak creatinine level and postoperative renal failure, however, strong interactions between preoperative GFR and sidearm cannulation were present, resulting in reductions of postoperative renal complications of 15% to 20% when GFR was <60 mL>/min/1.73 m(2). For normal GFR, the effect was negated or even reversed at very high levels of GFR. Mortality, although not significantly affected by sidearm cannulation, showed a similar trend to the renal outcomes. CONCLUSION: Use of sidearm cannulation is associated with a clinically important and highly statistically significant reduction in postoperative renal complications in patients with a low GFR. Reduced renal effect of skeletal muscle ischemia is the proposed mechanism. Effects among patients with good preoperative renal function are less clear. A randomized trial is needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patients with ilio-femoral deep-vein thrombosis (DVT) are at high risk of developing the post-thrombotic syndrome (PTS). In comparison to anticoagulation therapy alone, extended venography-guided catheter-directed thrombolysis without routine stenting of venous stenosis in patients with ilio-femoral DVT is associated with an increased risk of bleeding and a moderate reduction of PTS. We performed a prospective single-centre study to investigate safety, patency and incidence of PTS in patients with acute ilio-femoral DVT treated with fixed-dose ultrasound-assisted catheter-directed thrombolysis (USAT; 20 mg rt-PA during 15 hours) followed by routing stenting of venous stenosis, defined as residual luminal narrowing >50%, absent antegrade flow, or presence of collateral flow at the site of suspected stenosis. A total of 87 patients (age 46 ± 21 years, 60% women) were included. At 15 hours, thrombolysis success ≥50% was achieved in 67 (77%) patients. Venous stenting (mean 1.9 ± 1.3 stents) was performed in 70 (80%) patients, with the common iliac vein as the most frequent stenting site (83%). One major (1%; 95% CI, 0-6%) and 6 minor bleedings (7%; 95%CI, 3-14%) occurred. Primary and secondary patency rates at 1 year were 87% (95% CI, 74-94%) and 96% (95% CI, 88-99%), respectively. At three months, 88% (95% CI, 78-94%) of patients were free from PTS according to the Villalta scale, with a similar rate at one year (94%, 95% CI, 81-99%). In conclusion, a fixed-dose USAT regimen followed by routine stenting of underlying venous stenosis in patients with ilio-femoral DVT was associated with a low bleeding rate, high patency rates, and a low incidence of PTS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To describe the nerve stimulator-guided sciatic-femoral nerve block in raptors undergoing surgical treatment of pododermatitis. STUDY DESIGN Prospective clinical trial. ANIMALS Five captive raptors (Falco peregrinus) aged 6.7 ± 1.3 years. METHODS Anaesthesia was induced and maintained with isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine (0.05 mL kg(-1) per nerve) as the sole intra-operative analgesic treatment. Intraoperative physiological variables were recorded every 10 minutes from endotracheal intubation until the end of anaesthesia. Assessment of intraoperative nociception was based on changes in physiological variables above baseline values, while evaluation of postoperative pain relied on species-specific behavioural indicators. RESULTS The sciatic-femoral nerve block was feasible in raptors and the motor responses following electrical stimulation of both nerves were consistent with those reported in mammalian species. During surgery no rescue analgesia was required. The anaesthesia plane was stable and cardiorespiratory variables did not increase significantly in response to surgical stimulation. Iatrogenic complications, namely nerve damage and local anaesthetic toxicity, did not occur. Recovery was smooth and uneventful. The duration (mean ± SD) of the analgesic effect provided by the nerve block was 130 ± 20 minutes. CONCLUSION AND CLINICAL RELEVANCE The sciatic-femoral nerve block as described in dogs and rabbits can be performed in raptors as well. Further clinical trials with a control groups are required to better investigate the analgesic efficacy and the safety of this technique in raptors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the clinical applicability of a nerve stimulator–guided technique, previously described in dogs, to block the sciatic and the femoral nerves in 4 pet rabbits (Oryctolagus cuniculus) undergoing hind limb surgeries. Preanesthetic intramuscular doses of medetomidine (0.08 mg/kg), ketamine (15 mg/kg), and buprenorphine (0.03 mg/kg) were administered to the rabbit patients. The rabbits were intubated and general anesthesia was maintained using isoflurane in oxygen. The sciatic-femoral nerve block was performed with 2% lidocaine at a volume of 0.05 mL/kg/nerve. Sciatic-femoral block was feasible in rabbits, and the motoric responses following electrical stimulation of both nerves were consistent with those reported in dogs after successful nerve location. Iatrogenic complications, namely nerve damage and local anesthetic toxicity, did not occur. Based on these results, the authors conclude that the sciatic-femoral nerve block described in dogs can be safely performed in rabbits. Clinical trials are required to assess the analgesic efficacy of the combined sciatic-femoral nerve block in rabbits as a part of multimodal pain management.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND It is unclear whether radial compared with femoral access improves outcomes in unselected patients with acute coronary syndromes undergoing invasive management. METHODS We did a randomised, multicentre, superiority trial comparing transradial against transfemoral access in patients with acute coronary syndrome with or without ST-segment elevation myocardial infarction who were about to undergo coronary angiography and percutaneous coronary intervention. Patients were randomly allocated (1:1) to radial or femoral access with a web-based system. The randomisation sequence was computer generated, blocked, and stratified by use of ticagrelor or prasugrel, type of acute coronary syndrome (ST-segment elevation myocardial infarction, troponin positive or negative, non-ST-segment elevation acute coronary syndrome), and anticipated use of immediate percutaneous coronary intervention. Outcome assessors were masked to treatment allocation. The 30-day coprimary outcomes were major adverse cardiovascular events, defined as death, myocardial infarction, or stroke, and net adverse clinical events, defined as major adverse cardiovascular events or Bleeding Academic Research Consortium (BARC) major bleeding unrelated to coronary artery bypass graft surgery. The analysis was by intention to treat. The two-sided α was prespecified at 0·025. The trial is registered at ClinicalTrials.gov, number NCT01433627. FINDINGS We randomly assigned 8404 patients with acute coronary syndrome, with or without ST-segment elevation, to radial (4197) or femoral (4207) access for coronary angiography and percutaneous coronary intervention. 369 (8·8%) patients with radial access had major adverse cardiovascular events, compared with 429 (10·3%) patients with femoral access (rate ratio [RR] 0·85, 95% CI 0·74-0·99; p=0·0307), non-significant at α of 0·025. 410 (9·8%) patients with radial access had net adverse clinical events compared with 486 (11·7%) patients with femoral access (0·83, 95% CI 0·73-0·96; p=0·0092). The difference was driven by BARC major bleeding unrelated to coronary artery bypass graft surgery (1·6% vs 2·3%, RR 0·67, 95% CI 0·49-0·92; p=0·013) and all-cause mortality (1·6% vs 2·2%, RR 0·72, 95% CI 0·53-0·99; p=0·045). INTERPRETATION In patients with acute coronary syndrome undergoing invasive management, radial as compared with femoral access reduces net adverse clinical events, through a reduction in major bleeding and all-cause mortality. FUNDING The Medicines Company and Terumo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

End caps are intended to prevent nail migration (push-out) in elastic stable intramedullary nailing. The aim of this study was to investigate the force at failure with and without end caps, and whether different insertion angles of nails and end caps would alter that force at failure. Simulated oblique fractures of the diaphysis were created in 15 artificial paediatric femurs. Titanium Elastic Nails with end caps were inserted at angles of 45°, 55° and 65° in five specimens for each angle to create three study groups. Biomechanical testing was performed with axial compression until failure. An identical fracture was created in four small adult cadaveric femurs harvested from two donors (both female, aged 81 and 85 years, height 149 cm and 156 cm, respectively). All femurs were tested without and subsequently with end caps inserted at 45°. In the artificial femurs, maximum force was not significantly different between the three groups (p = 0.613). Push-out force was significantly higher in the cadaveric specimens with the use of end caps by an up to sixfold load increase (830 N, standard deviation (SD) 280 vs 150 N, SD 120, respectively; p = 0.007). These results indicate that the nail and end cap insertion angle can be varied within 20° without altering construct stability and that the risk of elastic stable intramedullary nailing push-out can be effectively reduced by the use of end caps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE Proximal femoral osteotomy with stable fixation and sufficient correction. Low complication rates due to exact preoperative planning. INDICATIONS Congenital or traumatic femoral neck pseudarthrosis. Coxa vara. CONTRAINDICATIONS None. In severe deformities, a single femoral osteotomy may not solve the problem; thus, additional correction, e.g., a pelvic osteotomy, is required. SURGICAL TECHNIQUE Correct planning of the correction angle. Lateral approach. Subperiosteal detachment of vastus lateralis muscle. Place guide wire on the femoral neck to judge anteversion. Insert positioning wire 5 mm distal to trochanteric physis. Insert 2.8 mm Kirschner wire in the femoral neck. Osteotomy of the femur after marking the rotation by Kirschner wires or oscillating saw. Slide LC plate over Kirschner wires. Replace Kirschner wires with screws. Reduction of the femoral shaft to the plate with bone forceps. Definitive fixation of the plate to the femoral shaft by cortex or locking screws. Readaptation of vastus lateralis muscle over the plate. POSTOPERATIVE MANAGEMENT Partial weightbearing for 4-6 weeks depending on the age of the patient without any external fixation (e. g. cast) is possible. RESULTS Recent studies support the authors' findings of sufficient correction and stable fixation after proximal femoral osteotomy with the LCP pediatric hip plate. Low complication rates and stable fixation.