913 resultados para automated warehouse


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intestinal parasitosis constitutes a serious health problem in most tropical countries. The diagnosis of enteroparasites in laboratory routine relies on the examination of stool samples using optical microscopy and the error rates usually range from moderate to high. Approaches based on automatic image analysis have been proposed, but the methods are usually specific for some species, some of them are computationally expensive, and image acquisition and focus are manual. We present a solution to automate the diagnosis of the 15 most common species of enteroparasites in Brazil, using a sensitive parasitological technique, a motorized microscope with digital camera for automatic image acquisition and focus, and fast image analysis methods. The results indicate that our solution is effective and suitable for laboratory routine, in which the exam must be concluded in a few minutes. © 2013 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este trabalho apresenta uma proposta de aplicação de uma metodologia de lógica fuzzy à gestão de estoques de uma instituição pública da administração federal, localizada em Manaus-AM. Inicialmente, é realizada uma revisão da literatura sobre logística e gestão de suprimentos. Em seguida, são abordados assuntos relativos à gestão de estoques. Após isto, são discutidos tópicos referentes à Lógica Fuzzy. A metodologia proposta possibilitará um melhor controle do estoque, uma vez que serão substituídos os tradicionais métodos quantitativos de gerenciamento de estoques. Os dados utilizados foram coletados diretamente do almoxarifado da instituição em estudo, e referem-se à movimentação de estoque de um determinado item, durante o ano de 2009. A utilização da lógica fuzzy tem despertado, cada vez mais, a atenção de pesquisadores de diversas áreas do conhecimento, sendo, porém, que o grande desafio que se coloca aos mesmos é a modelagem dos dados coletados, em virtude do apoio computacional necessário a sua aplicação. A interação com os valores observados, operados pelas regras da lógica fuzzy permite um melhor controle das ações de um almoxarifado, tais como atendimento, reposição e licitação, uma vez que lida com situações de incerteza e subjetividade. A metodologia desenvolvida mostra-se apta a indicar de uma forma melhor a realização das citadas ações, sendo capaz de operacionalizar de forma automatizada o controle e o gerenciamento do estoque.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cryopreservation of sperm is important to preserve the gerrnplasm from animals of genetic value, which can die unexpectedly. This study compares conventional and automated methods of cryopreservation of spermatozoa obtained from the epididymis of bulls post-mortem. Twenty-two epididymides were obtained from a commercial slaughterhouse. Spermatozoa were collected from the tail of the epididymis using the retrograde flow technique. Thus, the samples, which were diluted in 10 ml of extender without glycerol (Botubov (R) I, Botupharma, Botucatu, SP, Brazil), were evaluated on motility, sperm vigor, structural and functional (swelling hypoosmotic test) membrane integrity, mitochondrial activity, sperm viability and ADN fragmentation. The samples were divided into two aliquots and diluted in extender with glycerol (Botubov (R) II, Botupharma, Botucatu, SP, Brazil) at a concentration of 50x10(6) motile sperm/0.5 French straws. One sample was frozen by the conventional method (4 hours at 5 degrees C, in a refrigerator and 20 min in nitrogen vapor) and the other by the automated method (Cryogen (R) Dualflex, Neovet, Uberaba, MG, Brazil). The parameters were higher in all the tests of fresh sperm samples, with the exception of the swelling hypoosmotic test, which showed no significant difference when the results were compared with sperm frozen by the conventional method. The average motility of fresh spermatozoa was 74%, and conventional and automated averages were 29 and 25%, respectively. Therefore, although cryopreservation techniques reduce sperm quality parameters, the viability of the sperm is maintained, and these methods can be used to preserve sperm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Project aims to develop methods for data classification in a Data Warehouse for decision-making purposes. We also have as another goal the reduction of an attribute set in a Data Warehouse, in which a given reduced set is capable of keeping the same properties of the original one. Once we achieve a reduced set, we have a smaller computational cost of processing, we are able to identify non-relevant attributes to certain kinds of situations, and finally we are also able to recognize patterns in the database that will help us to take decisions. In order to achieve these main objectives, it will be implemented the Rough Sets algorithm. We chose PostgreSQL as our data base management system due to its efficiency, consolidation and finally, it’s an open-source system (free distribution)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the supply chain management there are several risk factors that must be mitigated to increase the flow of production and as a possible solution the literature cites the implementation of a warehouse management system, but this subject is few explored. This thesis has as main objective the study of the implementation of a warehouse management system in a company from the automotive sector that produces clutches. As results, are shown data of the characterization of items; as well as data and comparisons between disruptions in production reports due to lack of material before and after the implementation of WMS and is presented the result of a questionnaire applied to the involved on the implementation of the system, the results were associated with the risk factors on the implementation of the system studied on the literature review, and enumeration of the results that are not associated with any factors previously studied. And finally, the study is concluded and are recommended future studies related to the theme

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of self-adaptive software (SaS) has specific characteristics compared to traditional one, since it allows that changes to be incorporated at runtime. Automated processes have been used as a feasible solution to conduct the software adaptation at runtime. In parallel, reference model has been used to aggregate knowledge and architectural artifacts, since capture the systems essence of specific domains. However, there is currently no reference model based on reflection for the development of SaS. Thus, the main contribution of this paper is to present a reference model based on reflection for development of SaS that have a need to adapt at runtime. To present the applicability of this model, a case study was conducted and good perspective to efficiently contribute to the area of SaS has been obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Insulin resistance is a common risk factor in chronic kidney disease patients contributing to the high cardiovascular burden, even in the absence of diabetes. Glucose-based peritoneal dialysis (PD) solutions are thought to intensify insulin resistance due to the continuous glucose absorption from the peritoneal cavity. The aim of our study was to analyse the effect of the substitution of glucose for icodextrin on insulin resistance in non-diabetic PD patients in a multicentric randomized clinical trial. This was a multicenter, open-label study with balanced randomization (1:1) and two parallel-groups. Inclusion criteria were non-diabetic adult patients on automated peritoneal dialysis (APD) for at least 3 months on therapy prior to randomization. Patients assigned to the intervention group were treated with 2L of icodextrin 7.5%, and the control group with glucose 2.5% during the long dwell and, at night in the cycler, with a prescription of standard glucose-based PD solution only in both groups. The primary end-point was the change in insulin resistance measured by homeostatic model assessment (HOMA) index at 90 days. Sixty patients were included in the intervention (n = 33) or the control (n = 27) groups. There was no difference between groups at baseline. After adjustment for pre-intervention HOMA index levels, the group treated with icodextrin had the lower post-intervention levels at 90 days in both intention to treat [1.49 (95% CI: 1.23-1.74) versus 1.89 (95% CI: 1.62-2.17)], (F = 4.643, P = 0.03, partial η(2) = 0.078); and the treated analysis [1.47 (95% CI: 1.01-1.84) versus 2.18 (95% CI: 1.81-2.55)], (F = 7.488, P = 0.01, partial η(2) = 0.195). The substitution of glucose for icodextrin for the long dwell improved insulin resistance measured by HOMA index in non-diabetic APD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The impact of peritoneal dialysis modality on patient survival and peritonitis rates is not fully understood, and no large-scale randomized clinical trial (RCT) is available. In the absence of a RCT, the use of an advanced matching procedure to reduce selection bias in large cohort studies may be the best approach. The aim of this study is to compare automated peritoneal dialysis (APD) and continuous ambulatory peritoneal dialysis (CAPD) according to peritonitis risk, technique failure and patient survival in a large nation-wide PD cohort. This is a prospective cohort study that included all incident PD patients with at least 90 days of PD recruited in the BRAZPD study. All patients who were treated exclusively with either APD or CAPD were matched for 15 different covariates using a propensity score calculated with the nearest neighbor method. Clinical outcomes analyzed were overall mortality, technique failure and time to first peritonitis. For all analysis we also adjusted the curves for the presence of competing risks with the Fine and Gray analysis. After the matching procedure, 2,890 patients were included in the analysis (1,445 in each group). Baseline characteristics were similar for all covariates including: age, diabetes, BMI, Center-experience, coronary artery disease, cancer, literacy, hypertension, race, previous HD, gender, pre-dialysis care, family income, peripheral artery disease and year of starting PD. Mortality rate was higher in CAPD patients (SHR1.44 CI95%1.21-1.71) compared to APD, but no difference was observed for technique failure (SHR0.83 CI95%0.69-1.02) nor for time till the first peritonitis episode (SHR0.96 CI95%0.93-1.11). In the first large PD cohort study with groups balanced for several covariates using propensity score matching, PD modality was not associated with differences in neither time to first peritonitis nor in technique failure. Nevertheless, patient survival was significantly better in APD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fogging of ReJeX-iT7 TP-40 offers a very efficient method for the control and dispersal of nuisance birds from many diverse areas. The amount of the repellent is greatly reduced over any other control method. The method is direct and is independent of the activity of the birds. The applications with any fogger, thermal or mechanical, that can deliver droplets of less than 20 microns, can be manually or fully automated and pose only minimal risks to operators or animals. All birds that became a nuisance and safety problem in the hangars of TWA and AA at LaGuardia, and TWA warehouse at Newark Airport were successfully driven out by fogging ReJeX-iT7 TP-40 with a Curtis Dyna-Fog AGolden Eagle@ thermal fogger.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Traditional abduction imposes as a precondition the restriction that the background information may not derive the goal data. In first-order logic such precondition is, in general, undecidable. To avoid such problem, we present a first-order cut-based abduction method, which has KE-tableaux as its underlying inference system. This inference system allows for the automation of non-analytic proofs in a tableau setting, which permits a generalization of traditional abduction that avoids the undecidable precondition problem. After demonstrating the correctness of the method, we show how this method can be dynamically iterated in a process that leads to the construction of non-analytic first-order proofs and, in some terminating cases, to refutations as well.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A sensitive, selective, and reproducible in-tube solid-phase microextraction and liquid chromatographic (in-tube SPME/LC-UV) method for determination of lidocaine and its metabolite monoethylglycinexylidide (MEGX) in human plasma has been developed, validated, and further applied to pharmacokinetic study in pregnant women with gestational diabetes mellitus (GDM) subjected to epidural anesthesia. Important factors in the optimization of in-tube SPME performance are discussed, including the draw/eject sample volume, draw/eject cycle number, draw/eject flow rate, sample pH, and influence of plasma proteins. The limits of quantification of the in-tube SPME/LC method were 50 ng/mL for both metabolite and lidocaine. The interday and intraday precision had coefficients of variation lower than 8%, and accuracy ranged from 95 to 117%. The response of the in-tube SPME/LC method for analytes was linear over a dynamic range from 50 to 5000 ng/mL, with correlation coefficients higher than 0.9976. The developed in-tube SPME/LC method was successfully used to analyze lidocaine and its metabolite in plasma samples from pregnant women with GDM subjected to epidural anesthesia for pharmacokinetic study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Automated weaning modes are available in some mechanical ventilators, but no studies compared them hitherto. We compared the performance of 3 automated modes under standard and challenging situations. Methods: We used a lung simulator to compare 3 automated modes, adaptive support ventilation (ASV), mandatory rate ventilation (MRV), and Smartcare, in 6 situations, weaning success, weaning failure, weaning success with extreme anxiety, weaning success with Cheyne-Stokes, weaning success with irregular breathing, and weaning failure with ineffective efforts. Results: The 3 modes correctly recognized the situations of weaning success and failure, even when anxiety or irregular breathing were present but incorrectly recognized weaning success with Cheyne-Stokes. MRV incorrectly recognized weaning failure with ineffective efforts. Time to pressure support (PS) stabilization was shorter for ASV (1-2 minutes for all situations) and MRV (1-7 minutes) than for Smartcare (8-78 minutes). ASV had higher rates of PS oscillations per 5 minutes (4-15), compared with Smartcare (0-1) and MRV (0-12), except when extreme anxiety was present. Conclusions: Smartcare, ASV, and MRV were equally able to recognize weaning success and failure, despite the presence of anxiety or irregular breathing but performed incorrectly in the presence of Cheyne-Stokes. PS behavior over the time differs among modes, with ASV showing larger and more frequent PS oscillations over the time. Clinical studies are needed to confirm our results. (C) 2012 Elsevier Inc. All rights reserved.