923 resultados para Vaginal balls
Resumo:
Cylpebs are slightly tapered cylindrical grinding media with a ratio of length to diameter of unity. The manufactures have made conflicting claims regarding the milling performance of Cylpebs in comparison with balls. One major point of interest is which one grinds finer at the same operating conditions. The difficulty in comparison is due to the shape difference. The two grinding media have different surface area, bulk density and contact mechanisms in grinding action. Comparative tests were conducted using the two types of grinding media in a laboratory Bond ball mill at various conditions of equality such as media mass, size distribution, surface area and input specific energy. The laboratory results indicate that at the same specific energy input level the Cylpebs produce a product with slightly less oversize due to their greater surface area, but essentially the same sizing at the fine end as that produced with the balls. The reason may be that the advantage of greater surface area is balanced by the line contact and area contact grinding actions with the Cylpebs. A new ball mill scale-up procedure [Man, Y.T., 2001. Model-based procedure for scale-up of wet, overflow ball mills, Part 1: outline of the methodology. Minerals Engineering 14 (10), 1237-1246] was employed to predict grinding performance of an industrial mill from the laboratory test results. The predicted full scale operation was compared with the plant survey data. Some problems in the original scale-up procedures were identified. The scale-up procedure was therefore modified to allow the predicted ball mill performance to match the observed one. The calibrated scale-up procedure was used to predict the Cylpebs performance in the full scale industrial mill using the laboratory tests results. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The breast cancer susceptibility gene Brca1 encodes a large multi-functional protein which is implicated as a caretaker of the genome, through its role in regulation of DNA damage response pathways, including apoptosis. Here we show that in mice expressing a dominant-negative Brca1 transgene on a BALB/c background, vaginal entrance remodeling is inhibited, and that the incidence of this phenotype is increased on a p53 +/- genotype. Given that this developmental process is mediated primarily by apoptosis, we hypothesized that disruption of BRCA1 may confer a resistance to apoptosis in normal epithelial cells. Consistent with this, we show that expression of this transgene in vitro leads to resistance to ionizing radiation induced cell killing in mammary epithelial cells. This is the first time that BRCA1 has been implicated in an apoptosis-mediated normal developmental process.
Resumo:
Aims The major aims of the study were to compare the safety of a continuous low-dose estradiol-releasing vaginal ring (ESTring) to that of a vaginal estradiol tablet (Vagifem®) on the endometrium and the relief of subjective symptoms and signs of urogenital estrogen deficiency. Quality of life and acceptability of treatment delivery were also assessed. Study design A prospective, randomized study in which women were assigned in a 2: 1 ratio to ESTring and Vagifem and followed for 12 months. The primary endpoint was endometrial safety, based on the results of ultrasound measurement of endometrial thickness and a progestogen challenge test at baseline and week 48. Efficacy was determined by subjective assessment of urogenital estrogen deficiency symptoms at baseline and weeks 3, 12, 24, 36 and 48 and assessment of signs of vaginal epithelial atrophy by the clinician at baseline, 12 and 48 weeks. In addition, pelvic floor strength, vaginal cytological evaluation and pH, bacteruria and patient acceptability were assessed. Quality of life was assessed using a menopause-specific quality-of-life questionnire and a 2-day bladder diary at baseline and 12 and 48 weeks. The comparability of the two groups was assessed using ANOVA, χ(2) or Fisher's exact tests. Results A total of 126 women were randomized to ESTring and 59 to Vagifem. There was no statistical difference between the groups in the alleviation of symptoms and signs of urogenital estrogen deficiency. Maturation indices increased in both groups, from generally atrophic at baseline to proliferative or highly proliferative at 48 weeks. After 48 weeks of treatment, there was no statistically significant difference in endometrial thickness between the two groups. A statistically smaller proportion of bleeding/spotting occurred in the ESTring group (n = 0) compared to the Vagifem users (n = 4). Estradiol and total estrone serum levels increased during treatment in both groups but remained within the normal postmenopausal range. General health status in both groups was unchanged but the urogenital component of health burden was significantly improved in both groups. Bladder diary variables showed no differences between treatment groups. Conclusion Equivalent endometrial safety and efficacy in the relief of the symptoms and signs of urogenital estrogen deficiency were demonstrated for the 12 months' use of a low-dose estradiol-releasing vaginal ring and a vaginal estradiol tablet.
Resumo:
Background: There is limited information available on the requirement for postoperative analgesic drugs in patients submitted to total laparoscopic hysterectomy (TLH) compared with patients undergoing vaginal hysterectomy (VH). Aim: To compare the postoperative analgesic requirements in patients who underwent a TLH with patients who had a VH. Methods: Chart review of 53 patients who had TLH and 47 who had VH and were seen postoperatively by an acute pain management service in order to assess postoperative analgesic requirements. Patient controlled analgesia (PCA) was part of the standard protocol for postoperative pain management. Analgesic requirement was recorded as the mean doses of morphine and number of days that patients used non-steroidal anti-inflammatory drugs (NSAIDs), oxycodone and tramadol. Results: The requirement for total morphine was approximately half the dose in patients who had a TLH (10.8 +/- 12.6 mg) compared with patients who had a VH (19.4 +/- 21.9 mg) (P 0.017). The length of use of NSAIDs was significantly reduced in patients who had undergone a TLH (2.0 +/- 0.95 days) as compared with patients who had a VH (2.85 +/- 1.1 days) (P < 0.0001). Conclusions: Patients submitted to TLH require less postoperative analgesic drugs when compared with patients who had VH. Prospective randomised trials are warranted to compare analgesic requirements between patients submitted to TLH and VH.
Resumo:
Various factors can influence the population dynamics of phytophages post introduction, of which climate is fundamental. Here we present an approach, using a mechanistic modelling package (CLIMEX), that at least enables one to make predictions of likely dynamics based on climate alone. As biological control programs will have minimal funding for basic work (particularly on population dynamics), we show how predictions can be made using a species geographical distribution, relative abundance across its range, seasonal phenology and laboratory rearing data. Many of these data sets are more likely to be available than long-term population data, and some can be incorporated into the exploratory phase of a biocontrol program. Although models are likely to be more robust the more information is available, useful models can be developed using information on species distribution alone. The fitted model estimates a species average response to climate, and can be used to predict likely geographical distribution if introduced, where the agent is likely to be more abundant (i.e. good locations) and more importantly for interpretation of release success, the likely variation in abundance over time due to intra- and inter-year climate variability. The latter will be useful in predicting both the seasonal and long-term impacts of the potential biocontrol agent on the target weed. We believe this tool may not only aid in the agent selection process, but also in the design of release strategies, and for interpretation of post-introduction dynamics and impacts. More importantly we are making testable predictions. If biological control is to become more of a science making and testing such hypothesis will be a key component.
Resumo:
A major goal in vaccine development is elimination of the 'cold chain', the transport and storage system for maintenance and distribution of the vaccine product. This is particularly pertinent to liquid formulation of vaccines. We have previously described the rod-insert vaginal ring (RiR) device, comprising an elastomeric body into which are inserted lyophilised, rod-shaped, solid drug dosage forms, and having potential for sustained mucosal delivery of biomacromolecules, such as HIV envelope protein-based vaccine candidates. Given the solid, lyophilised nature of these insert dosage forms, we hypothesised that antigen stability may be significantly increased compared with more conventional solubilised vaginal gel format. In this study, we prepared and tested vaginal ring devices fitted with lyophilised rod inserts containing the model antigen bovine serum albumin (BSA). Both the RiRs and the gels that were freeze-dried to prepare the inserts were evaluated for BSA stability using PAGE, turbidimetry, microbial load, MALDI-TOF and qualitative precipitate solubility measurements. When stored at 4°C, but not when stored at 40°C/75% RH, the RiR formulation offered protection against structural and conformational changes to BSA. The insert also retained matrix integrity and release characteristics. The results demonstrate that lypophilised gels can provide relative protection against degradation at lower temperatures compared to semi-solid gels. The major mechanism of degradation at 40°C/75% RH was shown to be protein aggregation. Finally, in a preliminary study, we found that addition of trehalose to the formulation significantly reduces the rate of BSA degradation compared to the original formulation when stored at 40°C/75% RH. Establishing the mechanism of degradation, and finding that degradation is decelerated in the presence of trehalose, will help inform further development of RiRs specifically and polymer based freeze-dried systems in general.
Resumo:
A robust vaginal immune response is considered essential for an effective prophylactic vaccine that prevents transmission of HIV and other sexually acquired diseases. Considerable attention has recently focused on the potential of vaginally administered vaccines as a means to induce such local immunity. However, the potential for vaccination at this site remains in doubt as the vaginal mucosa is generally considered to have low immune inductive potential. In the current study, we explored for the first time the use of a quick release, freeze-dried, solid dosage system for practical vaginal administration of a protein antigen. These solid dosage forms overcome the common problem associated with leakage and poor retention of vaginally administered antigen solutions. Mice were immunized vaginally with H4A, an HIV gp41 envelope based recombinant protein, using quick release, freeze-dried solid rods, and the immune responses compared to a control group immunized via subcutaneous H4A injection. Vaginally immunized mice failed to elicit robust immune responses. Our detailed investigations, involving cytokine analysis, the stability of H4A in mouse cervicovaginal lavage, and elucidation of the state of H4A protein in the immediate-release dosage form, revealed that antigen instability in vaginal fluid, the state of the antigen in the dosage form, and the cytokine profile induced are all likely to have contributed to the observed lack of immunogenicity. These are important factors affecting vaginal immunization and provide a rational basis for explaining the typically poor and variable elicitation of immunity at this site, despite the presence of immune responsive cells within the vaginal mucosae. In future mucosal vaccine studies, a more explicit focus on antigen stability in the dosage form and the immune potential of available antigen-responsive cells is recommended.
Resumo:
Aqueous semi-solid polymeric gels, such as those based on hydroxyethylcellulose (HEC) and polyacrylic acid (e.g. Carbopol®), have a long history of use in vaginal drug delivery. However, despite their ubiquity, they often provide sub-optimal clinical performance, due to poor mucosal retention and limited solubility for poorly water-soluble actives. These issues are particularly pertinent for vaginal HIV microbicides, since many lead candidates are poorly water-soluble and where a major goal is the development of a coitally independent, once daily gel product. In this study, we report the use of a non-aqueous silicone elastomer gel for vaginal delivery of the HIV-1 entry inhibitor maraviroc. In vitro rheological, syringeability and retention studies demonstrated enhanced performance for silicone gels compared with a conventional aqueous HEC gel, while testing of the gels in the slug model confirmed a lack of mucosal irritancy. Pharmacokinetic studies following single dose vaginal administration of a maraviroc silicone gel in rhesus macaques showed higher and sustained MVC levels in vaginal fluid, vaginal tissue and plasma compared with a HEC gel containing the same maraviroc loading. The results demonstrate that non-aqueous silicone gels have potential as a formulation platform for coitally independent vaginal HIV microbicides.