991 resultados para Three Bodies


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE. To evaluate the change in vision after 3 monthly consecutive intravitreal injections of 1.25 mg of bevacizumab for neovascular age-related macular degeneration (AMD). METHODS. A retrospective analysis of 35 eyes was performed. Visual acuity (VA) at initial visit and at each follow-up visit was compared. The injection of bevacizumab was performed at 30-day intervals and patients were observed for 5 months after the last injection. RESULTS. Of the 35 eyes, 9 had received previous treatment with photodynamic therapy with or without 4 mg of intravitreal triamcinolone. VA was measured in Snellen table and transformed into logMAR for statistical purposes. Mean age was 76.66 years (range, 49-90 years). There were 24(69%) women and 11(31%) men. Mean VA at the initial visit was 0.92 +/- 0.50. At month 1, mean VA was 0.84 +/- 0.51 and at month 2 was 0.74 +/- 0.51. At month 3, mean VA remained 0.74 +/- 0.49. Six and 8 months after the initial visit, VA was 0.79 +/- 0.49 and 0.77 +/- 0.50, respectively. The improvement in VA was statistically significant at month 2 and at the end of the follow-up (8 months) compared with the baseline VA. CONCLUSIONS. Three consecutive monthly injections of intravitreal bevacizumab to treat neovascular AMD is effective in improving VA in the short term. Longer prospective studies should be performed to confirm VA stability after the third injection. (Eur J Ophthalmol 2010; 20: 740-4)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate wavefront performance and modulation transfer function (MTF) in the human eye aft er the implantation of diffractive or refractive multifocal intraocular lenses (IOLs). Materials and Methods: This was a prospective, interventional, comparative, nonrandomized clinical study. Uncorrected distance and near visual acuity, and wavefront analysis including MTF curves (iTrace aberrometer, Tracey Technologies, Houston, TX, USA) were measured in 60 patients aft er bilateral IOL implantation with 6 months of follow-up. Forty eyes received the diffractive ReSTOR (Alcon), 40 eyes received the refractive ReZoom (Advanced Medical Optics) and 40 eyes, the Tecnis ZM900 (Advanced Medical Optics). The comparison of MTF and aberration between the intraocular lenses was performed using analysis of variance (ANOVA), followed by the Dunn test when necessary. Results: The mean uncorrected distance visual acuity was similar in all three groups of multifocal IOLs. The ReSTOR group provided better uncorrected near visual acuity than the ReZoom group (P < 0.001), but similar to the Tecnis group. Spherical aberration was significantly higher in the ReZoom group (P = 0.007). Similar MTF curves were found for the aspheric multifocal IOL Tecnis and the spheric multifocal IOL ReSTOR, and both performed better than the multifocal IOL ReZoom in a 5 mm pupil (P < 0.001 at all spatial frequencies). Conclusions: Diffractive IOLs studied presented similar MTF curves for a 5 mm pupil diameter. Both diffractive IOLs showed similar spherical aberration, which was significantly better with the full-diffractive IOL Tecnis than with the refractive IOL ReZoom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to explore the feasibility of an exercise scientist (ES) working in general practice to promote physical activity (PA) to 55 to 70 year old adults. Participants were randomised into one of three groups: either brief verbal and written advice from a general practitioner (GP) (G1, N=9); or individualised counselling and follow-up telephone calls from an ES, either with (G3, N=8) or without a pedometer (G2, N=11). PA levels were assessed at week 1, after the 12-wk intervention and again at 24 weeks. After the 12-wk intervention, the average increase in PA was 116 (SD=237) min/wk; N=28, p < 0.001. Although there were no statistically significant between-group differences, the average increases in PA among G2 and G3 participants were 195 (SD=207) and 138 (SD=315) min/wk respectively, compared with no change (0.36, SD=157) in G1. After 24 weeks, average PA levels remained 56 (SD=129) min/wk higher than in week 1. The small numbers of participants in this feasibility study limit the power to detect significant differences between groups, but it would appear that individualised counselling and follow-up contact from an ES, with or without a pedometer, can result in substantial changes in PA levels. A larger study is now planned to confirm these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Numerical methods are used to simulate the double-diffusion driven convective pore-fluid flow and rock alteration in three-dimensional fluid-saturated geological fault zones. The double diffusion is caused by a combination of both the positive upward temperature gradient and the positive downward salinity concentration gradient within a three-dimensional fluid-saturated geological fault zone, which is assumed to be more permeable than its surrounding rocks. In order to ensure the physical meaningfulness of the obtained numerical solutions, the numerical method used in this study is validated by a benchmark problem, for which the analytical solution to the critical Rayleigh number of the system is available. The theoretical value of the critical Rayleigh number of a three-dimensional fluid-saturated geological fault zone system can be used to judge whether or not the double-diffusion driven convective pore-fluid flow can take place within the system. After the possibility of triggering the double-diffusion driven convective pore-fluid flow is theoretically validated for the numerical model of a three-dimensional fluid-saturated geological fault zone system, the corresponding numerical solutions for the convective flow and temperature are directly coupled with a geochemical system. Through the numerical simulation of the coupled system between the convective fluid flow, heat transfer, mass transport and chemical reactions, we have investigated the effect of the double-diffusion driven convective pore-fluid flow on the rock alteration, which is the direct consequence of mineral redistribution due to its dissolution, transportation and precipitation, within the three-dimensional fluid-saturated geological fault zone system. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: There is a paucity of information describing the real-time 3-dimensional echocardiography (RT3DE) and dyssynchrony indexes (DIs) of a normal population. We evaluate the RT3DE DIs in a population with normal electrocardiograms and 2- and 3-dimensional echocardiographic analyses. This information is relevant for cardiac resynchronization therapy. Methods: We evaluated 131 healthy volunteers (73 were male, aged 46 +/- 14 years) who were referred for routine echocardiography; who presented normal cardiac structure on electrocardiography, 2-dimensional echocardiography, and RT3DE; and who had no history of cardiac diseases. We analyzed 3-dimensional left ventricular ejection fraction, left ventricle end-diastolic volume, left ventricle end-systolic volume, and left ventricular systolic DI% (6-, 12-, and 16-segment models). RT3DE data were analyzed by quantifying the statistical distribution (mean, median, standard deviation [SD], relative SD, coefficient of skewness, coefficient of kurtosis, Kolmogorov-Smirnov test, D`Agostino-Pearson test, percentiles, and 95% confidence interval). Results: Left ventricular ejection fraction ranged from 50% to 80% (66.1% +/- 7.1%); left ventricle end-diastolic volume ranged from 39.8 to 145 mL (79.1 +/- 24.9 mL); left ventricle end-systolic volume ranged from 12.9 to 66 mL (27 +/- 12.1 mL); 6-segment DI% ranged from 0.20% to 3.80% (1.21% +/- 0.66%), median: 1.06, relative SD: 0.5482, coefficient of skewness: 1.2620 (P < .0001), coefficient of Kurtosis: 1.9956 (P = .0039); percentile 2.5%: 0.2900, percentile 97.5%: 2.8300; 12-segment DI% ranged from 0.22% to 4.01% (1.29% +/- 0.71%), median: 1.14, relative SD: 0.95, coefficient of skewness: 1.1089 (P < .0001), coefficient of Kurtosis: 1.6372 (P = .0100), percentile 2.5%: 0.2850, percentile 97.5%: 3.0700; and 16-segment DI% ranged from 0.29% to 4.88% (1.59 +/- 0.99), median: 1.39, relative SD: 0.56, coefficient of skewness: 1.0792 (P < .0001), coefficient of Kurtosis: 0.9248 (P = .07), percentile 2.5%: 0.3750, percentile 97.5%: 3.750. Conclusion: This study allows for the quantification of RT3DE DIs in normal subjects, providing a comparison for patients with heart failure who may be candidates for cardiac resynchronization therapy. (J Am Soc Echocardiogr 2008; 21: 1229-1235)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Real time three-dimensional echocardiography (RT3DE) has been demonstrated to be an accurate technique to quantify left ventricular (LV) volumes and function in different patient populations. We sought to determine the value of RT3DE for evaluating patients with hypertrophic cardiomyopathy (HCM), in comparison with cardiac magnetic resonance imaging (MRI). Methods: We studied 20 consecutive patients with HCM who underwent two-dimensional echocardiography (2DE), RT3DE, and MRI. Parameters analyzed by echocardiography and MRI included: wall thickness, LV volumes, ejection fraction (LVEF), mass, geometric index, and dyssynchrony index. Statistical analysis was performed by Lin agreement coefficient, Pearson linear correlation and Bland-Altman model. Results: There was excellent agreement between 2DE and RT3DE (Rc = 0.92), 2DE and MRI (Rc = 0.85), and RT3DE and MRI (Rc = 0.90) for linear measurements. Agreement indexes for LV end-diastolic and end-systolic volumes were Rc = 0.91 and Rc = 0.91 between 2DE and RT3DE, Rc = 0.94 and Rc = 0.95 between RT3DE and MRI, and Rc = 0.89 and Rc = 0.88 between 2DE and MRI, respectively. Satisfactory agreement was observed between 2DE and RT3DE (Rc = 0.75), RT3DE and MRI (Rc = 0.83), and 2DE and MRI (Rc = 0.73) for determining LVEF, with a mild underestimation of LVEF by 2DE, and smaller variability between RT3DE and MRI. Regarding LV mass, excellent agreement was observed between RT3DE and MRI (Rc = 0.96), with bias of -6.3 g (limits of concordance = 42.22 to -54.73 g). Conclusion: In patients with HCM, RT3DE demonstrated superior performance than 2DE for the evaluation of myocardial hypertrophy, LV volumes, LVEF, and LV mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PHWAT is a new model that couples a geochemical reaction model (PHREEQC-2) with a density-dependent groundwater flow and solute transport model (SEAWAT) using the split-operator approach. PHWAT was developed to simulate multi-component reactive transport in variable density groundwater flow. Fluid density in PHWAT depends not on only the concentration of a single species as in SEAWAT, but also the concentrations of other dissolved chemicals that can be subject to reactive processes. Simulation results of PHWAT and PHREEQC-2 were compared in their predictions of effluent concentration from a column experiment. Both models produced identical results, showing that PHWAT has correctly coupled the sub-packages. PHWAT was then applied to the simulation of a tank experiment in which seawater intrusion was accompanied by cation exchange. The density dependence of the intrusion and the snow-plough effect in the breakthrough curves were reflected in the model simulations, which were in good agreement with the measured breakthrough data. Comparison simulations that, in turn, excluded density effects and reactions allowed us to quantify the marked effect of ignoring these processes. Next, we explored numerical issues involved in the practical application of PHWAT using the example of a dense plume flowing into a tank containing fresh water. It was shown that PHWAT could model physically unstable flow and that numerical instabilities were suppressed. Physical instability developed in the model in accordance with the increase of the modified Rayleigh number for density-dependent flow, in agreement with previous research. (c) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical impedance tomography is a technique to estimate the impedance distribution within a domain, based on measurements on its boundary. In other words, given the mathematical model of the domain, its geometry and boundary conditions, a nonlinear inverse problem of estimating the electric impedance distribution can be solved. Several impedance estimation algorithms have been proposed to solve this problem. In this paper, we present a three-dimensional algorithm, based on the topology optimization method, as an alternative. A sequence of linear programming problems, allowing for constraints, is solved utilizing this method. In each iteration, the finite element method provides the electric potential field within the model of the domain. An electrode model is also proposed (thus, increasing the accuracy of the finite element results). The algorithm is tested using numerically simulated data and also experimental data, and absolute resistivity values are obtained. These results, corresponding to phantoms with two different conductive materials, exhibit relatively well-defined boundaries between them, and show that this is a practical and potentially useful technique to be applied to monitor lung aeration, including the possibility of imaging a pneumothorax.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To describe the microsurgical anatomy, branches, and anatomic relationships of the posterior cerebral artery (PCA) represented in three-dimensional images. METHODS: Seventy hemispheres of 35 brain specimens were studied. They were previously injected with red silicone and fixed in 10% formalin for at least 40 days. Four of the studied specimens were frozen at -10 degrees to -15 degrees C for 14 days, and additional dissection was done with the Klingler`s fiber dissection technique at x6 to x40 magnification. Each segment of the artery was measured and photographed to obtain three-dimensional stereoscopic images. RESULTS: The PCA origin was in the interpeduncular cistern at the pontomesencephalic junction level in 23 specimens (65.7%). The PCA was divided into four segments: P1 extends from the PCA origin to its junction with the posterior communicating artery with an average length of 7.7 mm; P2 was divided into an anterior and posterior segment. The P2A segment begins at the posterior communicating artery and ends at the most lateral aspect of the cerebral peduncle, with an average length of 23.6 mm, and the P2P segment extends from the most lateral aspect of the cerebral peduncle to the posterior edge of the lateral surface of the midbrain, with an average length of 16.4 mm; P3 extends from the posterior edge of the lateral surface of the midbrain and ends at the origin of the parieto-occipital sulcus along the calcarine fissure, with an average length of 19.8 mm; and the P4 segment corresponds to the parts of the PCA that run along or inside both the parieto-occipital sulcus and the distal part of the calcarine fissure. CONCLUSIONS: To standardize the neurosurgical practice and knowledge, surgical anatomic classifications should be used uniformly and further modified according to the neurosurgical experience gathered. The PCA classification proposed intends to correlate its anatomic segments with their required microneurosurgical approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The settling characteristics of cell debris and inclusion bodies prior to, and following, fractionation in a disc-stack centrifuge were measured using Cumulative Sedimentation Analysis (CSA) and Centrifugal Disc photosedimentation (CDS). The impact of centrifuge feedrate and repeated homogenisation on both cell debris and inclusion body collection efficiency was investigated. Increasing the normalised centrifuge feedrate (Q/Sigma) from 1.32 x 10(-9) m s(-1) to 3.97 x 10(-9) m s(-1) leads to a 36% increase in inclusion body paste purity. Purity may also be improved by repeated homogenisation. Increasing the number of homogeniser passes results in smaller cell debris size whilst leaves inclusion body size unaltered. At a normalised centrifuge feedrate of 2.65 x 10(-9) m s(-1), increasing the number of homogeniser passes from two (2) to ten (10) improved overall inclusion body paste purity by 58%. Grade-efficiency curves for both the cell debris and inclusion bodies have also been generated in this study. The data are described using an equation developed by Mannweiler (1989) with parameters of k = 0.15-0.26 and n = 2.5-2.6 for inclusion bodies, and k = 0.12-0.14 and n = 2.0-2.2 for cell debris. This is the first accurate experimentally-determined grade efficiency curve for cell debris. Previous studies have simply estimated debris grade efficiency curves using an approximate debris size distribution and grade efficiency curves determined with 'ideal particles' (e.g. spherical PVA particles). The findings of this study may be used to simulate and optimise the centrifugal fractionation of inclusion bodies from cell debris.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fibroblasts are thought to be partially responsible for the persisting contractile forces that result in burn contractures. Using a monolayer cell culture and fibroblast populated collagen lattice (FPCL) three-dimensional model we subjected hypertrophic scar and non-cicatricial fibroblasts to the antifibrogenic agent pentoxifylline (PTF - 1 mg/mL) in order to reduce proliferation, collagen types I and III synthesis and model contraction. Fibroblasts were isolated from post-burn hypertrophic scars (HSHF) and non-scarred skin (NHF). Cells were grown in monolayers or incorporated into FPCL`s and exposed to PTF. In monolayer, cell number proliferation was reduced (46.35% in HSHF group and 37.73% in NHF group, p < 0.0001). PTF selectively inhibited collagen III synthesis in the HSHF group while inhibition was more evident to type I collagen synthesis in the NHF group. PTF also reduced contraction in both (HSHF and NHF) FPCL. (C) 2009 Elsevier Ltd and ISBI. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Different abrasive wear tests have been applied to materials with hardnesses ranging from 80 HV (aluminium) to 1700 HV (tungsten carbide). The tests were: dry sand rubber wheel (DSRbrW); a similar test using a steel wheel (DSStlW); a new combined impact-abrasion test (FIA). The DSRbrW results were as expected, giving generally decreasing wear with increasing hardness. White cast irons and tool steels containing coarse, hard carbide particles performed better than more homogeneous materials of comparable hardness. When normalized to load and distance, the DSStlW results for the homogeneous materials were similar to the DSRbrW results. The multi-phase materials performed poorly in the DSStlW test, with volume loss for high-speed steel (880 HV) higher than that of aluminium. Within this group, wear increased with increasing hardness. These unexpected results are explained in terms of (a) differential friction coefficients of wheel and specimen, (b) increased fracture of sand, and (c) introduction of microfracture wear mechanisms. The FIA combined impact-abrasion results lacked clear correlations with hardness. The span of relative wear rates was similar to that reported for materials in ball mills. White cast irons at maximum hardness performed fairly poorly and showed evidence of microfracture. (C) 1997 Elsevier Science S.A.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Homocystinuria, due to a deficiency of the enzyme cystathionine beta-synthase (CBS), is an inborn error of sulphur-amino acid metabolism, This is an autosomal recessive disease which results in hyperhomocysteinaemia and a wide range of clinical features, including optic lens dislocation, mental retardation, skeletal abnormalities and premature thrombotic events, We report the identification of 5 missense mutations in the protein-coding region of the CBS gene from 3 patients with pyridoxine-nonresponsive homocystinuria. Reverse-transcription PCR was used to amplify CBS cDNA from each patient and the coding region was analysed by direct sequencing, The mutations detected included 3 novel (1058C --> T, 992C --> A and 1316G --> A) and 2 previously identified (430G --> A and 833C --> T) base alterations in the CBS cDNA, Each of these mutations predicts a single amino acid substitution in the CBS polypeptide, Appropriate cassettes of patient CBS cDNA, containing each of the above defined mutations, were used to replace the corresponding cassettes of normal CBS cDNA sequence within the bacterial expression vector pT7-7. These recombinant mutant and normal CBS constructs were expressed in Escherichia coli cells and the catalytic activities of the mutant proteins were compared with normal. All of the mutant proteins exhibited decreased catalytic activity in vitro, which confirmed the association between the individual mutation and CBS dysfunction in each patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate physicians` attitudes and adherence to the use of risk scores in the primary prevention of cardiovascular disease (CVD). Design and methods: A cross-sectional survey of 2056 physicians involved in the primary prevention of CVD. Participants included cardiologists (47%), general practitioners (42%), and endocrinologists (11%) from several geographical regions: Brazil (n=968), USA (n=381), Greece (n=275), Chile (n=157), Venezuela (n=128), Portugal (n=42), The Netherlands (n=41), and Central America (Costa Rica, Panama, El Salvador and Guatemala; n=64). Results: The main outcome measure was the percentage of responses on a multiple-choice questionnaire describing a hypothetical asymptomatic patient at intermediate risk for CVD according to the Framingham Risk Score. Only 48% of respondents reported regular use of CVD risk scores to tailor preventive treatment in the case scenario. Of non-users, nearly three-quarters indicated that `It takes up too much of my time` (52%) or `I don`t believe they add value to the clinical evaluation` (21%). Only 56% of respondents indicated that they would prescribe lipid-lowering therapy for the hypothetical intermediate-risk patient. A significantly greater proportion of regular users than non-users of CVD risk scores identified the need for lipid-lowering therapy in the hypothetical patient (59 vs. 41%; p<0.0001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Catheter migration or catheter fracture and consequent migration of a fragment is a rare complication that occurs in 1% of the patients. Despite the low incidence, embolization may cause severe and potentially fatal complications, with the mortality rates varying between 24 and 60%. The gold standard treatment for this condition is the extraction of the fragmented catheter by the intravascular percutaneous route, through the common femoral vein. If it is not available, the extraction procedure must be performed through an alternative access. This article describes a fully successful removal of a fragmented catheter by percutaneous intravascular access obtained through the right subclavian vein.