903 resultados para TRICKLING FILTERS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is on the use and performance of M-path polyphase Infinite Impulse Response (IIR) filters for channelisation, conventionally where Finite Impulse Response (FIR) filters are preferred. This paper specifically focuses on the Discrete Fourier Transform (DFT) modulated filter banks, which are known to be an efficient choice for channelisation in communication systems. In this paper, the low-pass prototype filter for the DFT filter bank has been implemented using an M-path polyphase IIR filter and we show that the spikes present at the stopband can be avoided by making use of the guardbands between narrowband channels. It will be shown that the channelisation performance will not be affected when polyphase IIR filters are employed instead of their counterparts derived from FIR prototype filters. Detailed complexity and performance analysis of the proposed use will be given in this article.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is based on the novel use of a very high fidelity decimation filter chain for Electrocardiogram (ECG) signal acquisition and data conversion. The multiplier-free and multi-stage structure of the proposed filters lower the power dissipation while minimizing the circuit area which are crucial design constraints to the wireless noninvasive wearable health monitoring products due to the scarce operational resources in their electronic implementation. The decimation ratio of the presented filter is 128, working in tandem with a 1-bit 3rd order Sigma Delta (ΣΔ) modulator which achieves 0.04 dB passband ripples and -74 dB stopband attenuation. The work reported here investigates the non-linear phase effects of the proposed decimation filters on the ECG signal by carrying out a comparative study after phase correction. It concludes that the enhanced phase linearity is not crucial for ECG acquisition and data conversion applications since the signal distortion of the acquired signal, due to phase non-linearity, is insignificant for both original and phase compensated filters. To the best of the authors’ knowledge, being free of signal distortion is essential as this might lead to misdiagnosis as stated in the state of the art. This article demonstrates that with their minimal power consumption and minimal signal distortion features, the proposed decimation filters can effectively be employed in biosignal data processing units.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resources created at the University of Southampton for the module Remote Sensing for Earth Observation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resources created at the University of Southampton for the module Remote Sensing for Earth Observation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Nuclear Medicine, radioiodine, in various chemical forms, is a key tracer used in diagnostic practices and/or therapy. Due to its high volatility, medical professionals may incorporate radioactive iodine during the preparation of the dose to be administered to the patient. In radioactive iodine therapy doses ranging from 3.7 to 7.4GBq per patient are employed. Thus, aiming at reducing the risk of occupational contamination, we developed a low cost filter to be installed at the exit of the exhaust system where doses of radioactive iodine are fractionated, using domestic technology. The effectiveness of radioactive iodine retention by silver impregnated silica [10%] crystals and natural activated carbon was verified using radiotracer techniques. The results showed that natural activated carbon is effective for I2 capture for a large or small amount of substrate but its use is restricted due to its low flash point (150º C). Besides, when poisoned by organic solvents, this flash point may become lower, causing explosions if absorbing large amounts of nitrates. To hold the CH3I gas, it was necessary to increase the volume of natural activated carbon since it was not absorbed by SiO2 + Ag crystals. We concluded that, for an exhaust flow range of (306 4) m3/h, a double stage filter using SiO2 + Ag in the first stage and natural activated carbon in the second is sufficient to meet radiological safety requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main aim of this work is to develop a methodology to evaluate the characteristics of porous media in filter using the radio-tracing technique. To do this, an experimental prototype filter made up of an acrylic cylinder, vertically mounted and supported on the lower side by a controlled leaking valve was developed. Two filters (spheres of acrylic and silica crystals) were used to check the movement of the water through the porous media using 123I in its MIBG (iodine-123-meta-iodo benzyl-guanidine) form. Further up the filter an instantaneous injection of the substance makes it possible to see the passage of radioactive clouds through the two scintillatory detectors NaI (2x2)” positioned before and immediately after the cylinder with the filtering element (porous media). The are caused by the detectors on the passage of the radioactive cloud are analyzed through statistical functions using the weighted moment method which makes it possible to calculate the Residence-Time (the amount of time the tracer takes to thoroughly pass through the filter) per the equation of dispersion in tubular flow and the one-directional flow of the radiotracer in the porous media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis focuses on the private membership test (PMT) problem and presents three single server protocols to resolve this problem. In the presented solutions, a client can perform an inclusion test for some record x in a server's database, without revealing his record. Moreover after executing the protocols, the contents of server's database remain secret. In each of these solutions, a different cryptographic protocol is utilized to construct a privacy preserving variant of Bloom filter. The three suggested solutions are slightly different from each other, from privacy perspective and also from complexity point of view. Therefore, their use cases are different and it is impossible to choose one that is clearly the best between all three. We present the software developments of the three protocols by utilizing various pseudocodes. The performance of our implementation is measured based on a real case scenario. This thesis is a spin-off from the Academy of Finland research project "Cloud Security Services".

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This document describes the kinds of items accepted for recycling at Lexington County recycling centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several Cronobacter outbreaks have implicated contaminated drinking water. This study assessed the impact of granular activated carbon (GAC) on the microbial quality of the water produced. A simulated water filter system was installed by filling plastic columns with sterile GAC, followed by sterile water with a dilute nutrient flowing through the column at a steady rate. Carbon columns were inoculated with Cronobacter on the surface, and the effluent monitored for Cronobacter levels. During a second phase, commercial faucet filters were distributed to households for 4-month use. Used filters were backwashed with sterile peptone water, and analyzed for Cronobacter, total aerobic plate count, coliform bacteria and Enterobacteriaceae. Cronobacter colonized the simulated GAC and grew when provided minimal levels of nutrients. Backwashed used filters used in home settings yielded presumptive Escherichia coli, Pseudomonas and other waterborne bacteria. Presumptive Cronobacter strains were identified as negative through biochemical and genetic test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The particulate matter distribution (PM) trends that exist in catalyzed particulate filters (CPFs) after loading, passive oxidation, active regeneration, and post loading conditions are not clearly understood. These data are required to optimize the operation of CPFs, prevent damage to the CPFs caused by non-uniform distributions, and develop accurate CPF models. To develop an understanding of PM distribution trends, multiple tests were conducted and the PM distribution was measured in three dimensions using a terahertz wave scanner. The results of this work indicate that loading, passive oxidation, active regeneration, and post loading can all cause non-uniform PM distributions. The density of the PM in the substrate after loading and the amount of PM that is oxidized during passive oxidations and active regenerations affect the uniformity of the distribution. Post loading that occurs after active regenerations result in distributions that are less uniform than post loading that occurs after passive oxidations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sunlight exposure causes several types of injury to humans, especially on the skin; among the most common harmful effects due to ultraviolet (UV) exposure are erythema, pigmentation and lesions in DNA, which may lead to cancer. These long-term effects are minimized with the use of sunscreens, a class of cosmetic products that contains UV filters as the main component in the formulation; such molecules can absorb, reflect or diffuse UV rays, and can be used alone or as a combination to broaden the protection on different wavelengths. Currently, worldwide regulatory agencies define which ingredients and what quantities must be used in each country, and enforce companies to conduct tests that confirm the Sun Protection Factor (SPF) and the UVA (Ultraviolet A) factor. Standard SPF determination tests are currently conducted in vivo, using human subjects. In an industrial mindset, apart from economic and ethical reasons, the introduction of an in vitro method emerges as an interesting alternative by reducing risks associated to UV exposure on tests, as well as providing assertive analytical results. The present work aims to describe a novel methodology for SPF determination directly from sunscreen formulations using the previously described cosmetomics platform and mass spectrometry as the analytical methods of choice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The application of sand filters in localized irrigation systems is recommended in the presence of organic and algae contamination. The proper design and maintenance of these equipments are essential to assure an effective water quality control, in order to reduce the emitters clogging, to keep its water application uniformity, and to prevent increasing in the system operation costs. Despite the existence of some references about design, operation and maintenance of these filters, they are dispersed, with not enough details to guarantee the optimization of its hydraulics structure design and the proper selection of porous media to be used. Therefore, the objective of this work was to report a current literature review, relating practical information with scientific knowledge. The content of this review would help to induce and intensify the research on this subject and to contribute so the operational functions for the equipment are reached. It is also expected to assist the improvement of the filtration and flushing processes in the agricultural irrigation and the development of original design procedures and the rational use of these devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of vegetal impurities in sugarcane delivered to sugarmills as green and dry leaves is a problem not only because they are non-value materials to be processed along with sugarcane stalks, but also because they can rise the color of the clarified juice and, consequently, the color of the sugar produced, with a reduction of its quality for the market. Another problem is the mud volume sedimented in the clarifiers, which also can result in a larger recirculation and greater volume of filtrate juice, with higher losses of sucrose and utilization of the vacuum rotary filters. The objective of this work was to observe the effect of the presence of green and dry leaves on sugarcane juice clarification, related to a control treatment with the addition of fiber extracted from the stalks. The experiments were planned based on the addition of quantities of fibrous sources in order to formulate samples with absolute increase of 0.25 , 0.50 and 0.75 percentual points over the fiber content of the sugarcane stalks (control treatment). The juice clarification was conducted with a laboratory clarifier. The clarified juice color and the mud volume were evaluated. The presence of green leaves caused higher color and mud volume due to the extraction of non-sucrose components of the leaves. Soluble compounds of dry leaves were also extracted, though not detected by juice analysis. The addition of the fiber extracted from the stalks did not induce alterations in the clarification process.