EXPERIMENTAL INVESTIGATION INTO PARTICULATE MATTER DISTRIBUTION IN CATALYZED PARTICULATE FILTERS USING A 3D TERAHERTZ WAVE SCANNER


Autoria(s): Foley, Ryan Kristopher
Data(s)

01/01/2013

Resumo

The particulate matter distribution (PM) trends that exist in catalyzed particulate filters (CPFs) after loading, passive oxidation, active regeneration, and post loading conditions are not clearly understood. These data are required to optimize the operation of CPFs, prevent damage to the CPFs caused by non-uniform distributions, and develop accurate CPF models. To develop an understanding of PM distribution trends, multiple tests were conducted and the PM distribution was measured in three dimensions using a terahertz wave scanner. The results of this work indicate that loading, passive oxidation, active regeneration, and post loading can all cause non-uniform PM distributions. The density of the PM in the substrate after loading and the amount of PM that is oxidized during passive oxidations and active regenerations affect the uniformity of the distribution. Post loading that occurs after active regenerations result in distributions that are less uniform than post loading that occurs after passive oxidations.

Formato

application/pdf

Identificador

http://digitalcommons.mtu.edu/etds/657

http://digitalcommons.mtu.edu/cgi/viewcontent.cgi?article=1655&context=etds

Publicador

Digital Commons @ Michigan Tech

Fonte

Dissertations, Master's Theses and Master's Reports - Open

Palavras-Chave #3D Distribution #Catalyzed Particulate Filter #Particulate Matter Distribution #Terahertz Wave Scanner #Mechanical Engineering #Power and Energy
Tipo

text