982 resultados para TOTAL FREE PHENOLICS
Resumo:
A total knee arthroplasty performed with navigation results in more accurate component positioning with fewer outliers. It is not known whether image-based or image-free-systems are preferable and if navigation for only one component leads to equal accuracy in leg alignment than navigation of both components. We evaluated the results of total knee arthroplasties performed with femoral navigation. We studied 90 knees in 88 patients who had conventional total knee arthroplasties, image-based total knee arthroplasties, or total knee arthroplasties with image-free navigation. We compared patients' perioperative times, component alignment accuracy, and short-term outcomes. The total surgical time was longer in the image-based total knee arthroplasty group (109 +/- 7 minutes) compared with the image-free (101 +/- 17 minutes) and conventional total knee arthroplasty groups (87 +/- 20 minutes). The mechanical axis of the leg was within 3 degrees of neutral alignment, although the conventional total knee arthroplasty group showed more (10.6 degrees ) variance than the navigated groups (5.8 degrees and 6.4 degrees , respectively). We found a positive correlation between femoral component malalignment and the total mechanical axis in the conventional group. Our results suggest image-based navigation is not necessary, and image-free femoral navigation may be sufficient for accurate component alignment.
Resumo:
Computer assisted orthopaedic surgery (CAOS) technology has recently been introduced to overcome problems resulting from acetabular component malpositioning in total hip arthroplasty. Available navigation modules can conceptually be categorized as computer tomography (CT) based, fluoroscopy based, or image-free. The current study presents a comprehensive accuracy analysis on the computer assisted placement accuracy of acetabular cups. It combines analyses using mathematical approaches, in vitro testing environments, and an in vivo clinical trial. A hybrid navigation approach combining image-free with fluoroscopic technology was chosen as the best compromise to CT-based systems. It introduces pointer-based digitization for easily assessable points and bi-planar fluoroscopy for deep-seated landmarks. From the in vitro data maximum deviations were found to be 3.6 degrees for inclination and 3.8 degrees for anteversion relative to a pre-defined test position. The maximum difference between intraoperatively calculated cup inclination and anteversion with the postoperatively measured position was 4 degrees and 5 degrees, respectively. These data coincide with worst cases scenario predictions applying a statistical simulation model. The proper use of navigation technology can reduce variability of cup placement well within the surgical safe zone. Surgeons have to concentrate on a variety of error sources during the procedure, which may explain the reported strong learning curves for CAOS technologies.
Resumo:
Chronic irritation of the iliopsoas tendon is a rare cause of persistent pain after total joint replacement of the hip. In the majority of cases, pain results from a mechanical conflict between the iliopsoas tendon and the anterior edge of the acetabular cup after total hip arthroplasty. Pain can be reproduced by active flexion of the hip and by active raising of the straightened leg. In addition, painful leg raising against resistance and passive hyperextension are suggestive of an irritation of the iliopsoas tendon. Symptoms evolve from a mechanical irritation of the iliopsoas tendon and an oversized or retroverted acetabular cup, screws penetrating into the inner aspect of the ilium, or from bone cement protruding beyond the anterior acetabular rim. The diagnosis may be assumed on conventional radiographs and confirmed by CT scans. Fifteen patients with psoas irritation after total hip replacement are reported on. Eleven patients were treated surgically. The acetabular cup was revised and reoriented with more anteversion in six patients, isolated screws penetrating into the tendon were cut and leveled in three patients, and prominent bone cement in conflict with the tendon was resected once. A partial release of the iliopsoas tendon only was performed in another patient. Follow-up examination (range: 11-89 months) revealed that nine patients were free of pain and two patient had mild residual complaints. Psoas irritation in combination with total hip replacement can be prevented by a correct surgical technique, especially with proper selection of the cup size and insertion of the acetabular cup avoiding a rim position exceeding the level of the anterior acetabular rim.
Resumo:
This study evaluated the efficacy and safety of intramuscular administration of NV1FGF, a plasmid-based angiogenic gene delivery system for local expression of fibroblast growth factor 1 (FGF-1), versus placebo, in patients with critical limb ischemia (CLI). In a double-blind, randomized, placebo-controlled, European, multinational study, 125 patients in whom revascularization was not considered to be a suitable option, presenting with nonhealing ulcer(s), were randomized to receive eight intramuscular injections of placebo or 2.5 ml of NV1FGF at 0.2 mg/ml on days 1, 15, 30, and 45 (total 16 mg: 4 x 4 mg). The primary end point was occurrence of complete healing of at least one ulcer in the treated limb at week 25. Secondary end points included ankle brachial index (ABI), amputation, and death. There were 107 patients eligible for evaluation. Improvements in ulcer healing were similar for use of NV1FGF (19.6%) and placebo (14.3%; P = 0.514). However, the use of NV1FGF significantly reduced (by twofold) the risk of all amputations [hazard ratio (HR) 0.498; P = 0.015] and major amputations (HR 0.371; P = 0.015). Furthermore, there was a trend for reduced risk of death with the use of NV1FGF (HR 0.460; P = 0.105). The adverse event incidence was high, and similar between the groups. In patients with CLI, plasmid-based NV1FGF gene transfer was well tolerated, and resulted in a significantly reduced risk of major amputation when compared with placebo.
Resumo:
Complications and failures after microvascular free tissue transfer for lower extremity reconstruction have a negative impact on postoperative course and final outcome. Therefore, a 10-year analysis on lower extremity reconstruction with free flaps was performed with a special emphasis on patient co-morbidities such as cardiovascular diseases, diabetes mellitus, body mass index and history of smoking, in order to identify potential risk factors. Complications such as haematoma, seroma, infection, wound dehiscence, as well as partial flap loss, postoperative thrombosis of the anastomosis and eventual total flap loss were gathered from the medical records. Limb salvage was 100%, however 40% suffered from complications ranging from minor wound dehiscence to total flap loss. None of the above-mentioned potential risk factors was associated with an increased rate of complications. However, in flaps that required revision for thrombosis, the age of the patients was significantly higher in the group of flaps that eventually failed when compared to flaps that were salvaged. In conclusion, lower extremity reconstruction with microvascular free tissue transfer is a safe and reliable procedure with a high success rate, however partial flap loss remains an important issue. Increased age was the only factor identified with an increased risk for subsequent flap loss in cases that were revised for thrombosis.
Resumo:
Although surgical techniques and the quality of mammary prostheses have been improved significantly in recent years, capsular contracture attendant on prosthetic mammary reconstruction remains a major flaw. Although rarely, some patients are confronted with recurrent and intractable capsular contractures with resultant breast deformity, even after multiple attempts at capsulectomies and implant exchange. Patients with recurrent capsular contracture often do not want replacement with a new prosthesis, but desire the maintenance of their breast volume with a safe alternative. In an attempt to maintain breast volume and to improve the aesthetic appearance, secondary breast reconstruction using bilateral deepithelialized free flaps from the lower abdomen was performed in a series of seven patients. Three bilateral muscle-sparing TRAM flaps, two bilateral DIEP flaps, one bilateral SIEA flap, one unilateral SIEA flap, and one unilateral DIEP flap (a total number of 14 flaps) were used following implant removal, total capsulectomy, and prophylactic subcutaneous mastectomy. The early postoperative course was uneventful, and all flaps survived completely with no complications. There were no donor-site problems, except in one patient (case 5), who had partial skin necrosis of the abdominal flap. The long-term results (mean follow-up: 4.8 years) demonstrated an aesthetically satisfactory appearance of the breasts, with no major donor-site problems. Several advantages, as well as drawbacks, are highlighted with this technique.
Resumo:
INTRODUCTION: The coverage of recurrent pressure sores with unstable scar in the surrounding tissue is still an unsolved problem in the literature. Local and regional transfer of tissue often does not meet the requirements of the tissue deficit. Especially in recurrent pressure sores, the adjacent skin has already been consumed due to multiple surgeries. As a good alternative, the microsurgical transfer of flaps offers viable tissue to cover even large pressure sores. METHODS: We performed a total of six free flaps in five patients who suffered from intractable pressure sores in the hip region. The age of the patients was between 41 and 63 years. The defect size varied between 6 x 6 cm and 25 x 30 cm. Two combined myocutaneous scapula-latissimus dorsi, two myocutaneous latissimus dorsi, one anteromedial thigh, and one rectus femoris flap were used to cover the defects. RESULTS: The average follow-up time was 29 months. Flaps provided stable coverage in four of five patients at 12-month follow-up. There was one subtotal flap necrosis that was subsequently treated with split-thickness skin grafting. CONCLUSION: In this series of five patients with six free flaps, we were able to show that the microsurgical transfer of tissue is a valuable option in the treatment of difficult pressure sores. Even in older and debilitated patients, this method is a good alternative to conventional local flaps.
Resumo:
Scaphoid is one of the 8 carpal bones found adjacent to the thumb supported proximally by Radius bone. During the free fall, on outstretched hand, the impact load gets transferred to the scaphoid at its free anterior end. Unique arrangement of other carpal bones in the palm is also one of the reasons for the load to get transferred to scaphoid. About half of the total load acting upon carpal bone gets transferred to scaphoid at its distal pole. There are about 10 to 12 clinically observed fracture pattern in the scaphoid due to free fall. The aim of the study is to determine the orientation of the load, magnitude of the load and the corresponding fracture pattern. This study includes both static and dynamic finite element models validated by experiments. The scaphoid model has been prepared from CT scans of a 27 year old person. The 2D slices of the CT scans have been converted to 3D model by using MIMICS software. There are four cases of loading studied which are considered to occur clinically more frequently. In case (i) the load is applied at the posterior end at distal pole whereas in case (ii), (iii) and (iv), the load is applied at anterior end at different directions. The model is given a fixed boundary condition at the region which is supported by Radius bone during the impact. Same loading and boundary conditions have been used in both static and dynamic explicit finite element analysis. The site of fracture initiation and path of fracture propagation have been identified by using max principal stress / gradient and max principal strain / gradient criterion respectively in static and dynamic explicit finite element analysis. Static and dynamic impact experiments were performed on the polyurethane foam specimens to validate the finite element results. Experimental results such as load at fracture, site of fracture initiation and path of fracture propagation have been compared with the results of finite element analysis. Four different types of fracture patterns observed in clinical studies have been identified in this study.
Resumo:
Free-ling amoebae (FLA) including Acanthamoeba spp., Naegleria fowleri, Balamuthia mandrillaris and Sappinia pedata, can cause opportunistic infections leading to severe brain pathologies. Human infections with pathogenic FLA have been increasingly documented in many countries. In Switzerland, thus far, the occurrence and distribution of potentially pathogenic FLA has not been investigated. Swiss water biotopes, including swimming pools, lakes, rivers and ponds, have now been screened for the presence of FLA, and assessment of their pathogenicity potential for a mammalian host has been undertaken. Thus, a total of 17 isolates were recovered by in vitro cultivation from these different aquatic sources. Characterization by sequence analysis of Acanthamoeba spp.-specific and 'FLA-specific PCR products amplified from 18s rDNA based on morphological traits, thermotolerance, and cytotoxicity towards murine fibroblasts yielded the following findings: Echinamoeba cf. exundans (3 isolates), Hartmannella spp. (3), Vannella spp. (4), Protacanthamoebica cf. bohemica (1), Acanthamoeba cf. castellanii (1) and Naegleria spp. (5). B. mandrillaris and N. fowleri did not range amongst these isolates. None of the isolates exhibited pronounced cytotoxicity and all failed to grow at 42 degrees C; therefore, they do not present any potential for CNS pathogenicity for humans.
Resumo:
BACKGROUND Prophylactic measures are key components of dairy herd mastitis control programs, but some are only relevant in specific housing systems. To assess the association between management practices and mastitis incidence, data collected in 2011 by a survey among 979 randomly selected Swiss dairy farms, and information from the regular test day recordings from 680 of these farms was analyzed. RESULTS The median incidence of farmer-reported clinical mastitis (ICM) was 11.6 (mean 14.7) cases per 100 cows per year. The median annual proportion of milk samples with a composite somatic cell count (PSCC) above 200,000 cells/ml was 16.1 (mean 17.3) %. A multivariable negative binomial regression model was fitted for each of the mastitis indicators for farms with tie-stall and free-stall housing systems separately to study the effect of other (than housing system) management practices on the ICM and PSCC events (above 200,000 cells/ml). The results differed substantially by housing system and outcome. In tie-stall systems, clinical mastitis incidence was mainly affected by region (mountainous production zone; incidence rate ratio (IRR) = 0.73), the dairy herd replacement system (1.27) and farmers age (0.81). The proportion of high SCC was mainly associated with dry cow udder controls (IRR = 0.67), clean bedding material at calving (IRR = 1.72), using total merit values to select bulls (IRR = 1.57) and body condition scoring (IRR = 0.74). In free-stall systems, the IRR for clinical mastitis was mainly associated with stall climate/temperature (IRR = 1.65), comfort mats as resting surface (IRR = 0.75) and when no feed analysis was carried out (IRR = 1.18). The proportion of high SSC was only associated with hand and arm cleaning after calving (IRR = 0.81) and beef producing value to select bulls (IRR = 0.66). CONCLUSIONS There were substantial differences in identified risk factors in the four models. Some of the factors were in agreement with the reported literature while others were not. This highlights the multifactorial nature of the disease and the differences in the risks for both mastitis manifestations. Attempting to understand these multifactorial associations for mastitis within larger management groups continues to play an important role in mastitis control programs.
Resumo:
INTRODUCTION The omega-3 and omega-6 polyunsaturated fatty acids (PUFAs) are the immediate precursors to a number of important mediators of immunity, inflammation and bone function, with products of omega-6 generally thought to promote inflammation and favour bone resorption. Western diets generally provide a 10 to 20-fold deficit in omega-3 PUFAs compared with omega-6, and this is thought to have contributed to the marked rise in incidence of disorders of modern human societies, such as heart disease, colitis and perhaps osteoporosis. Many of our food production animals, fed on grains rich in omega-6, are also exposed to a dietary deficit in omega-3, with perhaps similar health consequences. Bone fragility due to osteoporotic changes in laying hens is a major economic and welfare problem, with our recent estimates of breakage rates indicating up to 95% of free range hens suffer breaks during lay. METHODS Free range hens housed in full scale commercial systems were provided diets supplemented with omega-3 alpha linolenic acid, and the skeletal benefits were investigated by comparison to standard diets rich in omega-6. RESULTS There was a significant 40-60% reduction in keel bone breakage rate, and a corresponding reduction in breakage severity in the omega-3 supplemented hens. There was significantly greater bone density and bone mineral content, alongside increases in total bone and trabecular volumes. The mechanical properties of the omega-3 supplemented hens were improved, with strength, energy to break and stiffness demonstrating significant increases. Alkaline phosphatase (an osteoblast marker) and tartrate-resistant acid phosphatase (an osteoclast marker) both showed significant increases with the omega-3 diets, indicating enhanced bone turnover. This was corroborated by the significantly lower levels of the mature collagen crosslinks, hydroxylysyl pyridinoline, lysyl pyridinoline and histidinohydroxy-lysinonorleucine, with a corresponding significant shift in the mature:immature crosslink ratio. CONCLUSIONS The improved skeletal health in laying hens corresponds to as many as 68million fewer hens suffering keel fractures in the EU each year. The biomechanical and biochemical evidence suggests that increased bone turnover has enhanced the bone mechanical properties, and that this may suggest potential benefits for human osteoporosis.
Resumo:
High brightness electron sources are of great importance for the operation of the hard X-ray free electron lasers. Field emission cathodes based on the double-gate metallic field emitter arrays (FEAs) can potentially offer higher brightness than the currently used ones. We report on the successful application of electron beam lithography for fabrication of the large-scale single-gate as well as double-gate FEAs. We demonstrate operational high-density single-gate FEAs with sub-micron pitch and total number of tips up to 106 as well as large-scale double-gate FEAs with large collimation gate apertures. The details of design, fabrication procedure and successful measurements of the emission current from the single- and double-gate cathodes are presented.
Resumo:
BACKGROUND Copper and its main transport protein ceruloplasmin have been suggested to promote the development of atherosclerosis. Most of the data come from experimental and animal model studies. Copper and mortality have not been simultaneously evaluated in patients undergoing coronary angiography. METHODS AND RESULTS We examined whether serum copper and ceruloplasmin concentrations are associated with angiographic coronary artery disease (CAD) and mortality from all causes and cardiovascular causes in 3253 participants of the Ludwigshafen Risk and Cardiovascular Health Study. Age and sex-adjusted hazard ratios (HR) for death from any cause were 2.23 (95% CI, 1.85-2.68) for copper and 2.63 (95% CI, 2.17-3.20) for ceruloplasmin when we compared the highest with the lowest quartiles. Corresponding hazard ratios (HR) for death from cardiovascular causes were 2.58 (95% CI, 2.05-3.25) and 3.02 (95% CI, 2.36-3.86), respectively. Further adjustments for various risk factors and clinical variables considerably attenuated these associations, which, however, were still statistically significant and the results remained consistent across subgroups. CONCLUSIONS The elevated concentrations of both copper and ceruloplasmin are independently associated with increased risk of mortality from all causes and from cardiovascular causes.
Resumo:
OBJECTIVES To compare the free-hand (FH) technique of placing interlocking screws to a commercially available electromagnetic (EM) targeting system in terms of operating time, radiation dose, and accuracy of screw placement. METHODS Between September 2011 and July 2012, we prospectively randomized 100 consecutive femur shaft fractures in 99 patients requiring intramedullary nails to either FH using fluoroscopy (n = 43) or EM targeting (n = 38; Sureshot). SETTING Single Level 1 University Hospital Trauma Center. MAIN OUTCOME MEASUREMENTS The 2 groups were assessed for distal locking with respect to time, radiation, and accuracy. RESULTS Eight-one fractures had data accurately recorded (38 EM/43 FH). The average total operative time was 50 minutes (range, 25-88 minutes; SD, 13.9 minutes) for the FH group and 57 minutes (range, 40-103 minutes; SD, 16.12 minutes) for the EM group. The average time for distal locking was 10 minutes (range, 4-16 minutes; SD, 3.56 minutes) with FH and 11 minutes (range, 6-28 minutes; SD, 10.24 minutes) with EM. Average radiation dose for distal locking was significantly less (P < 0.0001) for EM at 230.54 μGy (range, 51-660 μGy; SD, 0.17 μGy) compared with 690.27 μGy (range, 200-2310 μGy; SD, 0.52 μGy) for FH. There were 2 misplaced drill bits in FH and 3 in EM. This was not statistically significant (P = 0.888). CONCLUSIONS The electromagnetic targeting device (Sureshot) significantly reduced radiation exposure during placement of distal interlocking screws, without sacrificing operative time, and was equivalent in accuracy when compared with the FH technique. LEVEL OF EVIDENCE Therapeutic level II.