972 resultados para Sample-sample two dimensional correlation spectroscopy (SS 2D)


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A 16-µm CO2-N2 downstream-mixing gasdynamic laser, where a cold CO2 stream is mixed with a vibrationally excited N2 stream at the exit of the nozzle, is studied theoretically. The flow field is analyzed using a two-dimensional, unsteady, laminar and viscous flow model including appropriate finite-rate vibrational kinetic equations. The analysis showed that local small-signal gain up to 21.75 m−1 can be obtained for a N2 reservoir temperature of 2000 K and a velocity ratio of 1:1 between the CO2 and N2 mixing streams. Applied Physics Letters is copyrighted by The American Institute of Physics.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quantization formats of four digital holographic codes (Lohmann,Lee, Burckhardt and Hsueh-Sawchuk) are evaluated. A quantitative assessment is made from errors in both the Fourier transform and image domains. In general, small errors in the Fourier amplitude or phase alone do not guarantee high image fidelity. From quantization considerations, the Lee hologram is shown to be the best choice for randomly phase coded objects. When phase coding is not feasible, the Lohmann hologram is preferable as it is easier to plot.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this investigation is to evolve a method of solving two-dimensional unsteady flow problems by the method of characteristics. This involves the reduction of the given system of equations to an equivalent system where only interior derivatives occur on a characteristic surface. From this system, four special bicharacteristic directional derivatives are chosen. A finite difference scheme is prescribed for solving the equations. General rectangular lattices are also considered. As an example, we investigate the propagation of an initial pressure distribution in a medium at rest.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract is not available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The multiplier ideals of an ideal in a regular local ring form a family of ideals parametrized by non-negative rational numbers. As the rational number increases the corresponding multiplier ideal remains unchanged until at some point it gets strictly smaller. A rational number where this kind of diminishing occurs is called a jumping number of the ideal. In this manuscript we shall give an explicit formula for the jumping numbers of a simple complete ideal in a two dimensional regular local ring. In particular, we obtain a formula for the jumping numbers of an analytically irreducible plane curve. We then show that the jumping numbers determine the equisingularity class of the curve.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Analytical solution of a 2-dimensional problem of solidification of a superheated liquid in a semi-infinite mould has been studied in this paper. On the boundary, the prescribed temperature is such that the solidification starts simultaneously at all points of the boundary. Results are also given for the 2-dimensional ablation problem. The solution of the heat conduction equation has been obtained in terms of multiple Laplace integrals involving suitable unknown fictitious initial temperatures. These fictitious initial temperatures have interesting physical interpretations. By choosing suitable series expansions for fictitious initial temperatures and moving interface boundary, the unknown quantities can be determined. Solidification thickness has been calculated for short time and effect of parameters on the solidification thickness has been shown with the help of graphs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Techniques to improve upon the design of two-dimensional encoding masks for multiplex Hadamard spectrometric imagers are described. The technique to generate masks based on completely orthonormal codes is described. In some cases, selfsupporting masks result which were not previously known. Transmission through the encoding masks (but not necessarily the signalto-noise ratio) can also be increased.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The modified local stability scheme is applied to several two-dimensional problems—blunt body flow, regular reflection of a shock and lambda shock. The resolution of the flow features obtained by the modified local stability scheme is found to be better than that achieved by the other first order schemes and almost identical to that achieved by the second order schemes incorporating artificial viscosity. The scheme is easy for coding, consumes moderate amount of computer storage and time. The scheme can be advantageously used in place of second order schemes.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Attention is given to the results of optimization studies with a 16-micron CO2-N2-H2 GDL employing two-dimensional wedge nozzles. The optimum value of the achievable gain reaches 12.7 percent/cm on the P(15) line for a 30:50:20 percent respective apportionment of the aforementioned gases. The corresponding optimum values for reservoir pressure and area ratio are computed as functions of reservoir temperature, and presented graphically.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sodium-ion batteries (SIBs) are considered as complementary alternatives to lithium-ion batteries for grid energy storage due to the abundance of sodium. However, low capacity, poor rate capability, and cycling stability of existing anodes significantly hinder the practical applications of SIBs. Herein, ultrathin two-dimensional SnS2 nanosheets (3-4 nm in thickness) are synthesized via a facile refluxing process toward enhanced sodium storage. The SnS2 nanosheets exhibit a high apparent diffusion coefficient of Na+ and fast sodiation/desodiation reaction kinetics. In half-cells, the nanosheets deliver a high reversible capacity of 733 mAh g-1 at 0.1 A g-1, which still remains up to 435 mAh g-1 at 2 A g-1. The cell has a high capacity retention of 647 mA h g-1 during the 50th cycle at 0.1 A g-1, which is by far the best for SnS2, suggesting that nanosheet morphology is beneficial to improve cycling stability in addition to rate capability. The SnS2 nanosheets also show encouraging performance in a full cell with a Na3V2(PO4)3 cathode. In addition, the sodium storage mechanism is investigated by ex situ XRD coupled with high-resolution TEM. The high specific capacity, good rate capability, and cycling durability suggest that SnS2 nanosheets have great potential working as anodes for high-performance SIBs. © 2015 American Chemical Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We consider diffusively coupled map lattices with P neighbors (where P is arbitrary) and study the stability of the synchronized state. We show that there exists a critical lattice size beyond which the synchronized state is unstable. This generalizes earlier results for nearest neighbor coupling. We confirm the analytical results by performing numerical simulations on coupled map lattices with logistic map at each node. The above analysis is also extended to two-dimensional P-neighbor diffusively coupled map lattices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Designing an ultrahigh density linear superlattice array consisting of periodic blocks of different semiconductors in the strong confinement regime via a direct synthetic route remains an unachieved challenge in nanotechnology. We report a general synthesis route for the formulation of a large-area ultrahigh density superlattice array that involves adjoining multiple units of ZnS rods by prolate US particles at the tips. A single one-dimensional wire is 300-500 nm long and consists of periodic quantum wells with a barrier width of 5 nm provided by ZnS and a well width of 1-2 nm provided by CdS, defining a superlattice structure. The synthesis route allows for tailoring of ultranarrow laserlike emissions (fwhm approximate to 125 meV) originating from strong interwell energy dispersion along with control of the width, pitch, and registry of the superlattice assembly. Such an exceptional high-density superlattice array could form the basis of ultrahigh density memories in addition to offering opportunities for technological advancement in conventional heterojunction-based device applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.