412 resultados para SQUID LOLIGO PEALII


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ectodermal Dysplasias syndrome (EDs) are a heterogeneous group of inherited disorders characterized by dysplasia of tissues of ectodermal origin. Complete or partial anodontia are the most frequent dental findings. Prosthetic rehabilitation is recommended from functional, esthetic, and psychological points of view. Because of the anatomical abnormalities of existing teeth and alveolar ridges, conventional prosthetic rehabilitation in young patient is often difficult. Five growing patients (age 9 to 11 years) with oligo- or anodontia were prosthetically rehabilitated. Panoramic film and Cone Bean Computerized Tomography were performed and a resin model of mandibular bone was made. Despite a remarkable multi-dimensional atrophy of the alveolar bone, the insertion of two tapered implants was possible. After a submerged healing period of 2 month, the implants were exposed and abutment connection was performed. Implants were connected with an expansion bar that permits mandibular growth and prosthetic retention. A removable prosthesis was constructed with ball attachments. Mandibular growth was followed and evaluated using the expansion guide and cephalometric radiographs. Mandibular growth in sagittal and transverse direction had no adverse effects on implant position. The expansion bar permitted the undisturbed growth of the mandible. After 4.5 years of follow-up, this study showed that Implant-supported overdenture may improve oral function, phonesis and esthetics. The mandibular rotation accompanying growth had not caused a significant problem relative to the angulation and migration of the implants. Implants can be successfully placed, restored and loaded in growing EDs patients. The cephalometric analysis supported that EDs patients show midface hypoplasia with a class III tendency, which can be avoided by early rehabilitation. Thanks to the good stability and retention of the implant-supported overdenture, patients considered the prostheses as comparable to natural teeth.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die Kombination magnetischer Nanopartikel (NP) mit temperatursensitiven Polymeren führt zur Bildung neuer Komposit-Materialien mit interessanten Eigenschaften, die auf vielfältige Weise genutzt werden können. Mögliche Anwendungsgebiete liegen in der magnetischen Trennung, der selektiven Freisetzung von Medikamenten, dem Aufbau von Sensoren und Aktuatoren. Als Polymerkomponente können z.B. Hydrogele dienen. Die Geschwindigkeit der Quellgradänderung mittels externer Stimuli kann durch eine Reduzierung des Hydrogelvolumens erhöht werden, da das Quellen ein diffusionskontrollierter Prozess ist. rnIm Rahmen dieser Arbeit wurde ein durch ultraviolettes Licht vernetzbares Hydrogel aus N-isopropylacrylamid, Methacrylsäure und dem Vernetzer 4-Benzoylphenylmethacrylat hergestellt (PNIPAAm-Hydrogel) und mit magnetischen Nanopartikeln aus Magnetit (Fe3O4) kombiniert. Dabei wurde die Temperatur- und die pH-Abhängigkeit des Quellgrades im Hinblick auf die Verwendung als nanomechanische Cantilever Sensoren (NCS) untersucht. Desweiteren erfolgte eine Charakterisierung durch Oberflächenplasmonen- und optischer Wellenleitermoden-Resonanz Spektroskopie (SPR/OWS). Die daraus erhaltenen Werte für den pKa-Wert und die lower critical solution Temperatur (LCST) stimmten mit den bekannten Literaturwerten überein. Es konnte gezeigt werden, dass eine stärkere Vernetzung zu einer geringeren LCST führt. Die Ergebnisse mittels NCS wiesen zudem auf einen skin-effect während des Heizens von höher vernetzten Polymeren hin.rnDie Magnetit Nanopartikel wurden ausgehend von Eisen(II)acetylacetonat über eine Hochtemperaturreaktion synthetisiert. Durch Variation der Reaktionstemperatur konnte die Größe der hergestellten Nanopartikel zwischen 3.5 und 20 nm mit einer Größenverteilung von 0.5-2.5 nm eingestellt werden. Durch geeignete Oberflächenfunktionalisierung konnten diese in Wasser stabilisiert werden. Dazu wurde nach zwei Strategien verfahren: Zum einen wurden die Nanopartikel mittels einer Silika-Schale funktionalisiert und zum anderen Zitronensäure als Tensid eingesetzt. Wasserstabilität ist vor allem für biologische Anwendungen wünschenswert. Die magnetischen Partikel wurden mit Hilfe von Transmissionselektronenmikroskopie (TEM), und superconductive quantum interference device (SQUID) charakterisiert. Dabei wurde eine Größenabhängigkeit der magnetischen Eigenschaften sowie superparamagnetisches Verhalten beobachtet. Außerdem wurde die Wärmeerzeugung der magnetischen Nanopartikel in einem AC Magnetfeld untersucht. rnDie Kombination beider Komponenten in Form eines Ferrogels wurde durch Mischen Benzophenon funktionalisierter magnetischer Nanopartikel mit Polymer erreicht. Durch Aufschleudern (Spin-Coaten) wurden dünne Filme erzeugt und diese im Hinblick auf ihr Verhalten in einem Magnetfeld untersucht. Dabei wurde eine geringes Plastikverhalten beobachtet. Die experimentellen Ergebnisse wurden anschließend mit theoretisch berechneten Erwartungswerten verglichen und mit den unterschiedlichen Werten für dreidimensionale Ferrogele in Zusammenhang gestellt. rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In case of violation of CPT- and Lorentz Symmetry, the minimal Standard Model Extension (SME) of Kostelecky and coworkers predicts sidereal modulations of atomic transition frequencies as the Earth rotates relative to a Lorentz-violating background field. One method to search for these modulations is the so-called clock-comparison experiment, where the frequencies of co-located clocks are compared as they rotate with respect to the fixed stars. In this work an experiment is presented where polarized 3He and 129Xe gas samples in a glass cell serve as clocks, whose nuclear spin precession frequencies are detected with the help of highly sensitive SQUID sensors inside a magnetically shielded room. The unique feature of this experiment is the fact that the spins are precessing freely, with transverse relaxation times of up to 4.4 h for 129Xe and 14.1 h for 3He. To be sensitive to Lorentz-violating effects, the influence of external magnetic fields is canceled via the weighted difference of the 3He and 129Xe frequencies or phases. The Lorentz-violating SME parameters for the neutron are determined out of a fit on the phase difference data of 7 spin precession measurements of 12 to 16 hours length. The result of the fit gives an upper limit for the equatorial component of the neutron parameter b_n of 3.7×10^(−32) GeV at the 95% confidence level. This value is not limited by the signal-to-noise ratio, but by the strong correlations between the fit parameters. To reduce the correlations and therewith improve the sensitivity of future experiments, it will be necessary to change the time structure of the weighted phase difference, which can be realized by increasing the 129Xe relaxation time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A field of computational neuroscience develops mathematical models to describe neuronal systems. The aim is to better understand the nervous system. Historically, the integrate-and-fire model, developed by Lapique in 1907, was the first model describing a neuron. In 1952 Hodgkin and Huxley [8] described the so called Hodgkin-Huxley model in the article “A Quantitative Description of Membrane Current and Its Application to Conduction and Excitation in Nerve”. The Hodgkin-Huxley model is one of the most successful and widely-used biological neuron models. Based on experimental data from the squid giant axon, Hodgkin and Huxley developed their mathematical model as a four-dimensional system of first-order ordinary differential equations. One of these equations characterizes the membrane potential as a process in time, whereas the other three equations depict the opening and closing state of sodium and potassium ion channels. The membrane potential is proportional to the sum of ionic current flowing across the membrane and an externally applied current. For various types of external input the membrane potential behaves differently. This thesis considers the following three types of input: (i) Rinzel and Miller [15] calculated an interval of amplitudes for a constant applied current, where the membrane potential is repetitively spiking; (ii) Aihara, Matsumoto and Ikegaya [1] said that dependent on the amplitude and the frequency of a periodic applied current the membrane potential responds periodically; (iii) Izhikevich [12] stated that brief pulses of positive and negative current with different amplitudes and frequencies can lead to a periodic response of the membrane potential. In chapter 1 the Hodgkin-Huxley model is introduced according to Izhikevich [12]. Besides the definition of the model, several biological and physiological notes are made, and further concepts are described by examples. Moreover, the numerical methods to solve the equations of the Hodgkin-Huxley model are presented which were used for the computer simulations in chapter 2 and chapter 3. In chapter 2 the statements for the three different inputs (i), (ii) and (iii) will be verified, and periodic behavior for the inputs (ii) and (iii) will be investigated. In chapter 3 the inputs are embedded in an Ornstein-Uhlenbeck process to see the influence of noise on the results of chapter 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Light pseudoscalar bosons, such as the axion that was originally proposed as a solution of the strong CP problem, would cause a new spin-dependent short-range interaction. In this thesis, an experiment is presented to search for axion mediated short-range interaction between a nucleon and the spin of a polarized bound neutron. This interaction cause a shift in the precession frequency of nuclear spin-polarized gases in the presence of an unpolarized mass. To get rid of magnetic field drifts co-located, nuclear spin polarized 3He and 129Xe atoms were used. The free nuclear spin precession frequencies were measured in a homogeneous magnetic guiding field of about 350nT using LTc SQUID detectors. The whole setup was housed in a magnetically shielded room at the Physikalisch Technische Bundesanstalt (PTB) in Berlin. With this setup long nuclear spin-coherence times, respectively, transverse relaxation times of 5h for 129Xe and 53h for 3He could be achieved. The results of the last run in September 2010 are presented which give new upper limits on the scalar-pseudoscalar coupling of axion-like particles in the axion-mass window from 10^(-2) eV to 10^(-6) eV. The laboratory upper bounds were improved by up to 4 orders of magnitude.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il fenomeno della magnetoresistenza gigante (GMR) consiste nella marcata variazione della resistenza elettrica di una struttura in forma di film sottile, composta da un’alternanza di strati metallici ferromagnetici (FM) e non magnetici (NM), per effetto di un campo magnetico esterno. Esso è alla base di un gran numero di sensori e dispositivi magnetoelettronici (come ad esempio magnetiche ad accesso casuale, MRAM, ad alta densità) ed ulteriori innovazioni tecnologiche sono in via di elaborazione. Particolarmente rilevanti sono diventate le Spin Valve, dispositivi composti da due strati FM separati da uno spaziatore NM, metallico. Uno dei due film FM (free layer) è magneticamente più soffice rispetto all’altro (reference layer), la cui magnetizzazione è fissata mediante accoppiamento di scambio all’interfaccia con uno strato antiferromagnetico (AFM) adiacente. Tale accoppiamento causa l’insorgenza di una anisotropia magnetica unidirezionale (anisotropia di scambio) per lo strato FM, che si manifesta in uno shift orizzontale del ciclo di isteresi ad esso associato (effetto di exchange bias), solitamente accompagnato anche da un aumento del campo coercitivo. Questo lavoro di tesi riporta la deposizione e la caratterizzazione magnetica e magnetoresistiva di due valvole spin, una a struttura top (SVT) composta da strati di Si/Cu[5 nm]/Py[5 nm]/Cu[5 nm]/Py[5 nm]/IrMn[10 nm], ed una a struttura bottom (SVB), di composizione Si/Cu[5 nm]/IrMn[10 nm]/Py[5 nm]/Cu[5 nm]/Py[5 nm], allo scopo di verificare il comportamento magnetoresistivo gigante del dispositivo per questa particolare scelta dei materiali. I campioni sono stati depositati mediante DC Magnetron sputtering, e caratterizzati magneticamente mediante magnetometro SQUID; la caratterizzazione resistiva è stata eseguita tramite metodo di van der Pawn. Vengono infine presentati i risultati sperimentali, in cui si osserva una variazione di magnetoresistenza nei campioni nell’ordine del punto percentuale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Food items and nematode parasites were identified from the stomachs of 42 individuals of Phocoena phocoena, 6 of Lagenorhynchus acutus and 8 of L. albirostris stranded off the coastal waters of Northern Scotland between 2004 and 2014. Post-mortem examinations have revealed heavy parasitic worm burdens. Four nematode species complex as Anisakis spp., Contracaeucum spp., Pseudoterronova spp., and Hysterothylacium spp. were recorded. Data on presence of the anisakid species in cetaceans, reported a significative relationship between the presence of Hysterothylacium and the month of host stranding; suggesting a decrease of larval H. aduncum abundance in the period between April and August due to a seasonal effect related to prey availability. Similarly, the parasite burden of the all anisakid genera was related to the year fraction of stranding, and a relationship statistically significant was found just for L. albirostris with an increase between April and October. This finding is explained by a seasonality in occurrence of white-beaked dolphins, with a peak during August, that might be related to movements of shared prey species and competition with other species (Tursiops truncatus). Geographical differences were observed in parasites number of all anisakid species, which was the highest in cetaceans from the East area and lowest in the North coast. The parasites number also increased significantly with the length of the animal and during the year, but with a significant seasonal pattern only for P. phocoena. Regarding diet composition, through a data set consisting of 34 harbour porpoises and 1 Atlantic white-sided dolphins, we found a positive association between parasite number and the cephalopods genus Alloteuthis. This higher level of parasite infection in squid from this area, is probably due to a quantitative distribution of infective forms in squid prey, an abundance of the final host and age or size maturity of squid.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Abbiamo sintetizzato un nuovo sistema nanogranulare consistente di nanoparticelle di magnetite inserite in idrossiapatite carbonata biomimetica per possibili future prospettive nell'ambito del tissue engineering osseo. Sono stati sintetizzati e studiati tre campioni nanogranulari, uno composto di nanoparticelle di magnetite e due composti di idrossiapatite contenenti magnetite per circa lo 0.8wt.% ed il 4wt.%. Le nanoparticelle di magnetite e il materiale composto sono stati analizzati tramite diffrazione a raggi X (XRD), spettroscopia all'infrarosso (FT-IR) e microscopia in trasmissione elettronica (TEM). Queste analisi hanno fornito informazioni sulla struttura delle nanoparticelle, come il size medio di circa 6 nm e hanno rivelato, sulla loro superficie, la presenza di gruppi idrossilici che incentivano la crescita successiva della fase di idrossiapatite, realizzando una struttura nanocristallina lamellare. I primi studi magnetici, condotti tramite un magnetometro SQUID, hanno mostrato che sia le nanoparticelle as-prepared sia quelle ricoperte di idrossiapatite sono superparamagnetiche a T=300K ma che il rilassamento della magnetizzazione è dominato da interazioni magnetiche dipolari di intensità confrontabile all'interno dei tre campioni. I valori di magnetizzazione più bassi di quelli tipici per la magnetite bulk ci hanno portato ad ipotizzare un possibile fenomeno di canting superficiale per gli spin delle nanoparticelle, fenomeno presente e documentato in letteratura. Nei tre campioni, quello di sole nanoparticelle di magnetite e quelli di idrossiapatite a diverso contenuto di magnetite, si forma uno stato collettivo bloccato a temperature inferiori a circa 20K. Questi risultati indicano che le nanoparticelle di magnetite tendono a formare agglomerati già nello stato as-prepared che sostanzialmente non vengono alterati con la crescita di idrossiapatite, coerentemente con la possibile formazione di legami idrogeno elettrostatici tra i gruppi idrossilici superficiali. L'analisi Mossbauer del campione di magnetite as-prepared ha mostrato un comportamento bimodale nelle distribuzioni dei campi iperfini presenti alle varie temperature. Passando dalle basse alle alte temperature lo spettro collassa in un doppietto, coerentemente con il passaggio dallo stato bloccato allo stato superparamagnetico per il sistema.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ocean Drilling Program (ODP) Sites 1257-1261 recovered thick sections of Upper Cretaceous-Eocene oceanic sediments on Demerara Rise off the east coast of Surinam and French Guiana, South America. Paleomagnetic and rock magnetic measurements of ~800 minicores established a high-resolution composite magnetostratigraphy spanning most of the Maastrichtian-Eocene. Magnetic behavior during demagnetization varied among lithologies, but thermal demagnetization steps >200°C were generally successful in removing present-day normal polarity overprints and a downward overprint induced during the ODP coring process. Characteristic remanent magnetizations and associated polarity interpretations were generally assigned to directions observed at 200°-400°C, and the associated polarity interpretations were partially based on whether the characteristic direction was aligned or apparently opposite to the low-temperature "north-directed" overprint. Biostratigraphy and polarity patterns constrained assignment of polarity chrons. The composite sections have a complete polarity record of Chrons C18n (middle Eocene)-C34n (Late Cretaceous).