999 resultados para QUASI-NORMAL MODES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to standardize signs and diagnostic criteria of respiratory function in newborn puppies delivered normally or after dystocia and caesarean operation. A total of 48 neonates were allocated into groups: eutocia (n = 20), dystocia (n = 8), caesarean (c)-section (n = 20). Neonatal health was assessed using the Apgar score and body temperature was determined at 0, 5 and 60 min after delivery. Venous blood gases (pO(2) and SO(2)) was measured immediately and 60 min after delivery, and a thoracic radiograph was made between 0 and 5 min of life. The c-section group had significantly lower Apgar scores at birth and 5 min. Hypothermia was present at 5 min in the eutocia and c-section groups, and at 60 min in all groups. The eutocia group had an irregular respiratory pattern in 78% of puppies at birth, 27.7% at 5 min and 21% at 60 min compared with 87.5%, 62.5% and 12.5% of the pups in the dystocia group where there was irregular respiratory rhythm, moderate to intense respiratory sounds with agonic episodes. The c-section group had respiratory alterations in 70%, 45% and 16% of puppies at 0, 5 and 60 min, respectively. Radiographic abnormalities were present in 17% of the pups in the eutocia group, 25% of the pups in the dystocia group and 30% of the pups in the c-section group, respectively. The c-section group had significantly lower SO(2) values at 60 min than at birth. All puppies had hypoxaemia, but a significant decrease was observed in the c-section group. Newborn puppies had tissue hypoxia and irregular respiratory pattern at birth. Caesarean-section puppies had lower vitality; however, all developed satisfactory Apgar scores at 5 min of life, regardless of the obstetric condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are limited data concerning blood gas parameters in neonatal dogs. Knowledge of the normal physiology may facilitate effective therapeutic intervention and potentially reduce neonatal mortality. This study examined acid-base parameters in pups born at normal parturition (n = 27) compared with those born after obstetrical assistance or caesarean operation (n = 13) and those born following oxytocin (OXY) administration for treatment of uterine inertia (n = 11). Pups were subjected to an objective scoring method of neonatal health adapted from use in humans (the Apgar score) at birth and again at 5 and 60 min after birth. Venous blood samples were collected at 5 and 60 min after birth for evaluation of blood gas parameters. At birth, all pups had low Apgar scores and a mixed acidosis. The base excess was lowest for pups delivered after OXY administration. The Apgar score improved for all pups after 5 min of birth and there was an improvement in carbon dioxide tension, base excess and venous blood pH at 1 h, although in all pups a metabolic acidosis persisted. These data provide an important insight into neonatal physiology and the variability of blood gas parameters in pups born at normal and abnormal parturition and provide the basis for clinical decision making following dystocia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this study, we investigated tooth-wear patterns in adolescents with either normal occlusion or Class II Division 2 malocclusion. Methods: The sample consisted of dental casts from 165 subjects that were divided into 2 groups: 115 normal occlusion subjects (mean age, 14.3 years) and 50 complete Class II Division 2 subjects (mean age, 13.9 years). Dental wear was assessed by using a modified version of the tooth wear index. The 2 groups were compared with the Mann-Whitney test for the frequency and severity of wear on each surface of each group of teeth. The level of statistical significance was set at 5%. Results: The normal occlusion group statistically had greater tooth wear on the incisal surfaces of the maxillary lateral incisors and the incisal surfaces of the maxillary canines than did the Class II Division 2 malocclusion group. The malocclusion group showed statistically greater tooth wear on the labial surfaces of the mandibular lateral incisors, the occlusal surfaces of the maxillary premolars and first molars, the occlusal surfaces of the mandibular premolars, the palatal surfaces of the maxillary second premolars, and the buccal surfaces of the mandibular premolars and first molars than did the normal occlusion group. Conclusions: Subjects with normal occlusion and those with complete Class II Division 2 malocclusions have different tooth-wear patterns. Tooth wear on the malocclusion subjects should not be considered pathologic but, rather, the consequence of different interocclusal arrangements. (Am J Orthod Dentofacial Orthop 2010;137:730.e1-730.e5)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to investigate the prevalence of tooth wear in adolescents with Class II malocclusion, compared with those with normal occlusion. Methods: The sample consisted of dental casts obtained from 310 subjects, divided into 3 groups: group 1, 110 subjects with normal occlusion (mean age, 13.51 years); group 2, 100 complete Class II Division 1 patients (mean age, 13.44 years); and group 3, 100 half-cusp Class II Division 1 patients (mean age, 13.17 years). Dental wear was assessed by using a modified version of the tooth-wear index. The 3 groups were compared by means of the Kruskal-Wallis and Dunn tests, considering the frequency and the severity of wear on each surface of each group of teeth. The level of statistical significance was set at 5%. Results: The normal occlusion group had statistically greater tooth wear on the palatal surfaces of the maxillary central incisors and the incisal surfaces of the maxillary canines than the corresponding surfaces in both Class II malocclusion groups. The complete and half-cusp Class II Division 1 malocclusion groups had statistically greater tooth wear on the occlusal surfaces of the maxillary second premolar and first molar, the occlusal surfaces of the mandibular premolars, and the buccal surfaces of the mandibular posterior teeth compared with the normal occlusion group. The half-cusp Class II Division 1 malocclusion group had significantly greater tooth wear on the incisal surfaces of the mandibular incisors compared with the complete Class II Division 1 malocclusion group. Conclusions: Subjects with normal occlusion and complete or half-cusp Class II Division 1 malocclusions have different tooth-wear patterns. Tooth wear on the malocclusion subjects should not be considered pathologic but rather consequent to the different interocclusal tooth arrangement. (Am J Orthod Dentofacial Orthop 2010; 137: 14. e1-14.e7)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Chipping within veneering porcelain has resulted in high clinical failure rates for implant-supported zirconia (yttria-tetragonal zirconia polycrystals [Y-TZP]) bridges. This study evaluated the reliability and failure modes of mouth-motion step-stress fatigued implant-supported Y-TZP versus palladium-silver alloy (PdAg) three-unit bridges. Materials and Methods: Implant-abutment replicas were embedded in polymethylmethacrylate resin. Y-TZP and PdAg frameworks, of similar design (n = 21 each), were fabricated, veneered, cemented (n = 3 each), and Hertzian contact-tested to obtain ultimate failure load. In each framework group, 18 specimens were distributed across three step-stress profiles and mouth-motion cyclically loaded according to the profile on the lingual slope of the buccal cusp of the pontic. Results: PdAg failures included competing flexural cracking at abutment and/or connector area and chipping, whereas Y-TZP presented predominantly cohesive failure within veneering porcelain. Including all failure modes, the reliability (two-sided at 90% confidence intervals) for a ""mission"" of 50,000 and 100,000 cycles at 300 N load was determined (Alta Pro, Reliasoft, Tucson, AZ, USA). No difference in reliability was observed between groups for a mission of 50,000. Reliability remained unchanged for a mission of 100,000 for PdAg, but significantly decreased for Y-TZP. Conclusions: Higher reliability was found for PdAg for a mission of 100,000 cycles at 300 N. Failure modes differed between materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate the effect of framework design on the fatigue life and failure modes of metal ceramic (MC, Ni-Cr alloy core, VMK 95 porcelain veneer), glass-infiltrated alumina (ICA, In-Ceram Alumina/VM7), and veneered yttria-stabilized tetragonal zirconia polycrystals (Y-TZP, IPSe.max ZirCAD/IPS e.max,) crowns. Methods: Sixty composite resin tooth replicas of a prepared maxillary first molar were produced to receive crowns systems of a standard (MCs, ICAs, and Y-TZPs, n = 10 each) or a modified framework design (MCm, ICAm, and Y-TZPm, n = 10 each). Fatigue loading was delivered with a spherical steel indenter (3.18 mm radius) on the center of the occlusal surface using r-ratio fatigue (30-300 N) until completion of 10(6) cycles or failure. Fatigue was interrupted every 125,000 cycles for damage evaluation. Weibull distribution fits and contour plots were used for examining differences between groups. Failure mode was evaluated by light polarized and SEM microscopy. Results: Weibull analysis showed the highest fatigue life for MC crowns regardless of framework design. No significant difference (confidence bound overlaps) was observed between ICA and Y-TZP with or without framework design modification. Y-TZPm crowns presented fatigue life in the range of MC crowns. No porcelain veneer fracture was observed in the MC groups, whereas ICAs presented bulk fracture and ICAm failed mainly through the veneer. Y-TZP crowns failed through chipping within the veneer, without core fractures. Conclusions: Framework design modification did not improve the fatigue life of the crown systems investigated. Y-TZPm crowns showed comparable fatigue life to MC groups. Failure mode varied according to crown system. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To test the strength to failure and fracture mode of three indirect composite materials directly applied onto Ti-6Al-4V implant abutments vs cemented standard porcelain-fused-to-metal (PFM) crowns. Materials and Methods: Sixty-four locking taper abutments were randomly allocated to four groups and were cleaned in ethanol in an ultrasonic bath for 5 min. After drying under ambient conditions, the abutments were grit blasted and a custom 4-cusp molar crown mold was utilized to produce identical crowns (n = 16 per group) of Tescera (Bisco), Ceramage (Shofu), and Diamond Crown (DRM) according to the manufacturer`s instructions. The porcelain-fused-to-metal crowns were fabricated by conventional means involving the construction and a wax pattern and casting of a metallic coping followed by sintering of increasing layers of porcelain. All crowns were loaded to failure by an indenter placed at one of the cusp tips at a 1 mm/min rate. Subsequently, fracture analysis was performed by means of stereomicroscopy and scanning electron microscopy. One-way ANOVA at 95% level of significance was utilized for statistical analysis. Results: The single load to failure (+/- SD) results were: Tescera (1130 +/- 239 N), Ceramage (1099 +/- 257 N), Diamond Crown (1155 +/- 284 N), and PFM (1081 +/- 243 N). Stereomicroscopy analysis showed two distinct failure modes, where the loaded cusp failed either with or without abutment/metallic coping exposure. SEM analysis of the fractures showed multiple crack propagation towards the cervical region of the crown below a region of plastic deformation at the indenter contact region. Conclusion: The three indirect composites and PFM systems fractured at loads higher than those typically associated with normal occlusal function. Although each material had a different composition and handling technique, no significant differences were found concerning their single load to fracture resistance among composite systems and PFM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We shall examine a model, first studied by Brockwell et al. [Adv Appl Probab 14 (1982) 709.], which can be used to describe the longterm behaviour of populations that are subject to catastrophic mortality or emigration events. Populations can suffer dramatic declines when disease, such as an introduced virus, affects the population, or when food shortages occur, due to overgrazing or fluctuations in rainfall. However, perhaps surprisingly, such populations can survive for long periods and, although they may eventually become extinct, they can exhibit an apparently stationary regime. It is useful to be able to model this behaviour. This is particularly true of the ecological examples that motivated the present study, since, in order to properly manage these populations, it is necessary to be able to predict persistence times and to estimate the conditional probability distribution of population size. We shall see that although our model predicts eventual extinction, the time till extinction can be long and the stationary exhibited by these populations over any reasonable time scale can be explained using a quasistationary distribution. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives To compare the reliability of the disto-facial (DF) and mesio-lingual (ML) cusps of an anatomically correct zirconia (Y-TZP) crown system The research hypotheses tested were (1) fatigue reliability and failure mode are similar for the ML and DF cusps, (2) failure mode of one cusp does not affect the failure of the other Methods The average dimensions of a mandibular first molar crown were imported into CAD software, a tooth preparation was modelled by 1 5 mm marginal high reduction of proximal walls and occlusal surface by 2 0 mm The CAD-based tooth preparation was milled and used as a die to fabricate crowns (n = 14) with porcelain veneer on a 0 5 mm Y-TZP core. Crowns were cemented on composite reproductions of the tooth preparation The crowns were step-stress mouth motion fatigued with sliding (0 7 mm) a tungsten-carbide indenter of 6 25 mm diameter down on the inclines of either the DF or ML cusps Use level probability Weibull curve with use stress of 200 N and the reliability for completion of a mission of 50,000 cycles at 200 N load were calculated Results Reliability for a 200 N at 50,000 cycles mission was not different between tested cusps SEM imaging showed large cohesive failures within the veneer for the ML and smaller for the DF Fractures originated from the contact area regardless of the cusp loaded Conclusion No significant difference on fatigue reliability was observed between the DF compared to the ML cusp Fracture of one cusp did not affect the other (c) 2010 Elsevier Ltd All rights reserved

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: The aim of this research was to evaluate the fatigue behavior and reliability of monolithic computer-aided design/computer-assisted manufacture (CAD/CAM) lithium disilicate and hand-layer-veneered zirconia all-ceramic crowns. Materials and Methods: A CAD-based mandibular molar crown preparation, fabricated using rapid prototyping, served as the master die. Fully anatomically shaped monolithic lithium disilicate crowns (IPS e.max CAD, n = 19) and hand-layer-veneered zirconia-based crowns (IPS e.max ZirCAD/Ceram, n = 21) were designed and milled using a CAD/CAM system. Crowns were cemented on aged dentinlike composite dies with resin cement. Crowns were exposed to mouth-motion fatigue by sliding a WC-indenter (r = 3.18 mm) 0.7 mm lingually down the distobuccal cusp using three different step-stress profiles until failure occurred. Failure was designated as a large chip or fracture through the crown. If no failures occurred at high loads (> 900 N), the test method was changed to staircase r ratio fatigue. Stress level probability curves and reliability were calculated. Results: Hand-layer-veneered zirconia crowns revealed veneer chipping and had a reliability of < 0.01 (0.03 to 0.00, two-sided 90% confidence bounds) for a mission of 100,000 cycles and a 200-N load. None of the fully anatomically shaped CAD/CAM-fabricated monolithic lithium disilicate crowns failed during step-stress mouth-motion fatigue (180,000 cycles, 900 N). CAD/CAM lithium disilicate crowns also survived r ratio fatigue (1,000,000 cycles, 100 to 1,000 N). There appears to be a threshold for damage/bulk fracture for the lithium disilicate ceramic in the range of 1,100 to 1,200 N. Conclusion: Based on present fatigue findings, the application of CAD/CAM lithium disilicate ceramic in a monolithic/fully anatomical configuration resulted in fatigue-resistant crowns, whereas hand-layer-veneered zirconia crowns revealed a high susceptibility to mouth-motion cyclic loading with early veneer failures. Int J Prosthodont 2010; 23: 434-442.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aims of this study were to evaluate the distances between the mandibular permanent teeth and the alveolar process in Brazilians with normal occlusion and to compare them with normal American values. Methods: We used 59 mandibular casts from untreated subjects who had permanent dentition and the 6 keys to normal occlusion. A computer program was used to calculate the distances between the dental reference points and the alveolar process for each tooth. The mean values were then compared to the normal values by applying the Student t test at a significance level of 0.05. Results: The results showed a progressive increase of these distances from the anterior region (incisors) to the posterior region (molars), from 0.00 to 2.49 mm. All measurements had statistically significant differences from the American sample, except for the values for canines and first premolars. Conclusions: Brazilians with normal occlusion have more lingual crown positions for the incisors, second premolars, and molars compared with Americans with normal occlusion. Although these findings were statistically significant, they are unlikely to be clinically significant. (Am J Orthod Dentofacial Orthop 2010; 137: 308.e1-308.e4)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the effect of 2% chlorhexidine digluconate (CHX) used as a therapeutic primer on the long-term bond strengths of two etch-and-rinse adhesives to normal (ND) and caries-affected (CAD) dentin. Forty extracted human molars with coronal carious lesions, surrounded by normal dentin, were selected for this study. The flat surfaces of two types of dentin (ND and CAD) were prepared with a water-cooled high-speed diamond disc, then acidetched, rinsed and air-dried. In the control groups, the dentin was re-hydrated with distilled water, blot-dried and bonded with a three-step (Scotchbond Multi-Purpose-MP) or two-step (Single Bond 2-SB) etch-and-rinse adhesive. In the experimental groups, the dentin was rehydrated with 2% CHX (60 seconds), blot-dried and bonded with the same adhesives. Resin composite build-ups were made. The specimens were prepared for microtensile bond testing in accordance with the non-trimming technique, then tested either immediately or after six-months storage in artificial saliva. The data were analyzed by ANOVA/Bonferroni tests (alpha=0.05). CHX did not affect the immediate bond strength to ND or CAD (p>0.05). CHX treatment significantly lowered the loss of bond strength after six months as seen in the control bonds for ND (p<0.05), but it did not alter the bond strength of CAD (p>0.05). The application of NIP on CHX-treated ND or CAD produced bonds that did not change over six months of storage.