931 resultados para Optimal active power flow
Resumo:
Hybrid electric vehicles (HEV) have attracted very much attention during the latest years. Increasing environmental concern and an increase in fuel prices are key factors for the growing interest towards the HEV. In a hybrid electric vehicle the power train consists of both a mechanical power system and an electric power transmission system. The major subsystems in the mechanical power system are the internal combustion engine which powers the vehicle; electric power transmission including an energy storage, power electronic inverter, hybrid control system; the electric motor drive that runs either in the generating mode or in the motoring mode to process the power flow between the energy storage and the electrical machine. This research includes two advanced electric motors for a parallel hybrid: induction machine and permanent magnets synchronous machine. In the thesis an induction motor and a permanent magnet motor are compared as propulsion motors. Electric energy storages are also studied.
Resumo:
The main aim of the study is to elucidate the meaning and dimensions of the concept of „virtue‟, and to find the place of virtue in a caritative caring ethics, i.e. a caring ethics based on human love and mercy. The intention is to create a theory model which utilizes the possibilities of virtue in developing the caritative caring ethics as a whole. The caritative caring ethics has a universal potential – it is primarily not a professional ethics, but it may form a frame of reference and basis for formulating ethical codes, and for ethical discussions within different caring contexts. The hermeneutic approach of the study is inspired by Gadamer‟s philosophical hermeneutics combined with the view of hermeneutics as a hypothetical-deductive process. The study is guided by Eriksson‟s model of definition of concepts. The concept of „virtue‟ is studied focusing on its ethical dimensions. These ethical dimensions of virtue are seen as anchored to an inner ethos, whereas ethos stands for the ontological goodness, a basic notion of the Good that permeates the entity of the human being, and forms the base of the culture where he lives and acts. The overarching research questions are: 1. What is virtue? 2. What is „virtue‟ as a basic concept in caring science? 3. What place does virtue have in caritative caring ethics? The answer of the first question is mainly searched for by an ontological determination comprising partly an etymologic and semantic analysis of „virtue‟, and partly a determination of the essence of virtue. The answer to the second and third questions are mainly searched for using a contextual determination, where the purposive context and pragmatic features of virtue are studied in relation to caring ethics. The ontological and contextual determinations are brought together through hermeneutical interpretation, forming a new whole, which constitutes the results of the study. The results of the study are depicted in a theory model, in which the movement of virtue from ethos to deed is moulded as caritative caring ethics. The material of the study consists of dictionaries, texts written by Aristotle and St. Thomas Aquinas, articles, dissertations, and books, as well as parts of a pilot survey answered by 33 nurses. The results of the study show that the essence of virtue is primarily functional, not ethical. The ethical emerges when virtue is contextualized in a human communion. Virtue makes something fulfil its function well; makes the human being good, and gives him morals and morality. The human being needs prudence, love, and humility to acquire and develop the moral virtues. Virtue is a power, related to a value, which considering a caritative caring ethics consists of the caritas motif. Human love is shown through deeds, making the human being do what he is expected to do. Virtue, as an active power of becoming, affirms and clarifies the human being‟s ability to develop in the direction of the Good. Virtue becomes essential and unifying when morality appears in the human mind as auctoritas, an inner, prompting power based on divinity or a transcendental ethos. Together ethos and virtue create opportunities for an inner ethics based on voluntariness and joy in being and doing the true, the good, and the beautiful.
Resumo:
Diplomityössä tarkastellaan tapausta, jossa tasasähköverkon vaihtosuuntaaja toteutetaan kolmella yksivaiheisella suuntaajalla yhden kolmivaiheisen sijaan. Modulaarinen rakenne mahdollistaa sen, että osa vaiheista voitaisiin sammuttaa kun kuormitus on erittäin pientä eikä kuorma ole kolmivaiheista. Galvaaninen erotus oletetaan tehtävän erottavalla DC-DC -konvertterilla, joka mahdollistaa samalla vaihtosuuntaajan DC-syöttöjännitteen muuttamisen. Työssä tutkitaan, mitkä tekijät vaikuttavat DC-syöttöjännitteen valintaan sekä tehdään valinta kyseisen jännitteen arvolle. Valittua jännitetasoa käytetään vaihtosuuntaajan suunnittelemiseen. Vaihtosuuntaajan rakennetta tarkastellaan vaihtosuuntaussillan kytkinkomponenttien sekä lähtöjännitteen suotimen osalta. Yksivaiheiselle moduulille määritetään optimaalinen teholuokka investointi- ja käyttökustannusten kannalta. Tarkastelu pitää sisällään erilaisten transistoritekniikkojen, kytkentätaajuuksien sekä kahden suodintyypin vaikutuksen kustannustehokkuuteen.
Resumo:
This work presents an application of the Mobility Approach to the analysis of the power flow through grillage-like structures. Such structures are usually found in offshore platforms, supporting large and heavy machines. Different wave kinds (longitudinal, flexural and torsional) were initially considered in the power flow analysis between two beams joined in L. Beams excited by an in-plane point force showed strong coupling between longitudinal-flexural waves, while that for out-of-plane point force excitation, flexural-torsional waves coupling represents the most important mechanism of energy transmission. The response determination of grillages by the mobility approach requires the structure to be separated into simple beam-like structural components. Equations for rotations and displacements at the joints of all beams are written for as mobility functions, and moments and forces acting at the joints. A system of equations relating all such internal forces and moments is obtained. This approach was applied to simple grillages. Response results showed good agreement when compared to those provided by Finite Elements.
Resumo:
Recent Storms in Nordic countries were a reason of long power outages in huge territories. After these disasters distribution networks' operators faced with a problem how to provide adequate quality of supply in such situation. The decision of utilization cable lines rather than overhead lines were made, which brings new features to distribution networks. The main idea of this work is a complex analysis of medium voltage distribution networks with long cable lines. High value of cable’s specific capacitance and length of lines determine such problems as: high values of earth fault currents, excessive amount of reactive power flow from distribution to transmission network, possibility of a high voltage level at the receiving end of cable feeders. However the core tasks was to estimate functional ability of the earth fault protection and the possibility to utilize simplified formulas for operating setting calculations in this network. In order to provide justify solution or evaluation of mentioned above problems corresponding calculations were made and in order to analyze behavior of relay protection principles PSCAD model of the examined network have been created. Evaluation of the voltage rise in the end of a cable line have educed absence of a dangerous increase in a voltage level, while excessive value of reactive power can be a reason of final penalty according to the Finish regulations. It was proved and calculated that for this networks compensation of earth fault currents should be implemented. In PSCAD models of the electrical grid with isolated neutral, central compensation and hybrid compensation were created. For the network with hybrid compensation methodology which allows to select number and rated power of distributed arc suppression coils have been offered. Based on the obtained results from experiments it was determined that in order to guarantee selective and reliable operation of the relay protection should be utilized hybrid compensation with connection of high-ohmic resistor. Directional and admittance based relay protection were tested under these conditions and advantageous of the novel protection were revealed. However, for electrical grids with extensive cabling necessity of a complex approach to the relay protection were explained and illustrated. Thus, in order to organize reliable earth fault protection is recommended to utilize both intermittent and conventional relay protection with operational settings calculated by the use of simplified formulas.
Resumo:
Wind turbines based on doubly fed induction generators (DFIG) become the most popular solution in high power wind generation industry. While this topology provides great performance with the reduced power rating of power converter, it has more complicated structure in comparison with full-rated topologies, and therefore leads to complexity of control algorithms and electromechanical processes in the system. The purpose of presented study is to present a proper vector control scheme for the DFIG and overall control for the WT to investigate its behavior at different wind speeds and in different grid voltage conditions: voltage sags, magnitude and frequency variations. The key principles of variable-speed wind turbine were implemented in simulation model and demonstrated during the study. Then, based on developed control scheme and mathematical model, the set of simulation is made to analyze reactive power capabilities of the DFIG wind turbine. Further, the rating of rotor-side converter is modified to not only generate active rated active power, but also to fulfill Grid Codes. Results of modelling and analyzing of the DFIG WT behavior under different speeds and different voltage conditions are presented in the work.
Resumo:
L'insuffisance cardiaque est une maladie à grande incidence dont le traitement définitif est difficile. Les pompes d'assistance ventriculaire ont été proposées comme thérapie alternative à long terme, mais la technologie est relativement jeune et selon son design, axial ou centrifuge, le dispositif favorise soit l'hémolyse, soit la stagnation de l'écoulement sanguin. Les pompes à écoulement mixte, combinant certaines propriétés des deux types, ont été proposées comme solution intermédiaire. Pour évaluer leurs performances, nous avons effectué des comparaisons numériques entre huit pompes, deux axiales, deux centrifuges, et quatre mixtes, en employant un modèle Windkessel du système cardiovasculaire avec paramètres optimisés pour l'insuffisance cardiaque résolu avec une méthode Radau IIA3, une méthode de résolution de système d'équations différentielles ordinaires L-stable appartenant à la famille des méthodes Runge-Kutta implicites. Nos résultats semblent suggérer que les pompes d'assistance mixtes ne démontrent qu'un léger avantage comparativement aux autres types en terme de performance optimale dans le cas de l'insuffisance cardiaque, mais il faudrait effectuer plus d'essais numériques avec un modèle plus complet, entre autres avec contrôles nerveux implémentés.
Resumo:
Study on variable stars is an important topic of modern astrophysics. After the invention of powerful telescopes and high resolving powered CCD’s, the variable star data is accumulating in the order of peta-bytes. The huge amount of data need lot of automated methods as well as human experts. This thesis is devoted to the data analysis on variable star’s astronomical time series data and hence belong to the inter-disciplinary topic, Astrostatistics. For an observer on earth, stars that have a change in apparent brightness over time are called variable stars. The variation in brightness may be regular (periodic), quasi periodic (semi-periodic) or irregular manner (aperiodic) and are caused by various reasons. In some cases, the variation is due to some internal thermo-nuclear processes, which are generally known as intrinsic vari- ables and in some other cases, it is due to some external processes, like eclipse or rotation, which are known as extrinsic variables. Intrinsic variables can be further grouped into pulsating variables, eruptive variables and flare stars. Extrinsic variables are grouped into eclipsing binary stars and chromospheri- cal stars. Pulsating variables can again classified into Cepheid, RR Lyrae, RV Tauri, Delta Scuti, Mira etc. The eruptive or cataclysmic variables are novae, supernovae, etc., which rarely occurs and are not periodic phenomena. Most of the other variations are periodic in nature. Variable stars can be observed through many ways such as photometry, spectrophotometry and spectroscopy. The sequence of photometric observa- xiv tions on variable stars produces time series data, which contains time, magni- tude and error. The plot between variable star’s apparent magnitude and time are known as light curve. If the time series data is folded on a period, the plot between apparent magnitude and phase is known as phased light curve. The unique shape of phased light curve is a characteristic of each type of variable star. One way to identify the type of variable star and to classify them is by visually looking at the phased light curve by an expert. For last several years, automated algorithms are used to classify a group of variable stars, with the help of computers. Research on variable stars can be divided into different stages like observa- tion, data reduction, data analysis, modeling and classification. The modeling on variable stars helps to determine the short-term and long-term behaviour and to construct theoretical models (for eg:- Wilson-Devinney model for eclips- ing binaries) and to derive stellar properties like mass, radius, luminosity, tem- perature, internal and external structure, chemical composition and evolution. The classification requires the determination of the basic parameters like pe- riod, amplitude and phase and also some other derived parameters. Out of these, period is the most important parameter since the wrong periods can lead to sparse light curves and misleading information. Time series analysis is a method of applying mathematical and statistical tests to data, to quantify the variation, understand the nature of time-varying phenomena, to gain physical understanding of the system and to predict future behavior of the system. Astronomical time series usually suffer from unevenly spaced time instants, varying error conditions and possibility of big gaps. This is due to daily varying daylight and the weather conditions for ground based observations and observations from space may suffer from the impact of cosmic ray particles. Many large scale astronomical surveys such as MACHO, OGLE, EROS, xv ROTSE, PLANET, Hipparcos, MISAO, NSVS, ASAS, Pan-STARRS, Ke- pler,ESA, Gaia, LSST, CRTS provide variable star’s time series data, even though their primary intention is not variable star observation. Center for Astrostatistics, Pennsylvania State University is established to help the astro- nomical community with the aid of statistical tools for harvesting and analysing archival data. Most of these surveys releases the data to the public for further analysis. There exist many period search algorithms through astronomical time se- ries analysis, which can be classified into parametric (assume some underlying distribution for data) and non-parametric (do not assume any statistical model like Gaussian etc.,) methods. Many of the parametric methods are based on variations of discrete Fourier transforms like Generalised Lomb-Scargle peri- odogram (GLSP) by Zechmeister(2009), Significant Spectrum (SigSpec) by Reegen(2007) etc. Non-parametric methods include Phase Dispersion Minimi- sation (PDM) by Stellingwerf(1978) and Cubic spline method by Akerlof(1994) etc. Even though most of the methods can be brought under automation, any of the method stated above could not fully recover the true periods. The wrong detection of period can be due to several reasons such as power leakage to other frequencies which is due to finite total interval, finite sampling interval and finite amount of data. Another problem is aliasing, which is due to the influence of regular sampling. Also spurious periods appear due to long gaps and power flow to harmonic frequencies is an inherent problem of Fourier methods. Hence obtaining the exact period of variable star from it’s time series data is still a difficult problem, in case of huge databases, when subjected to automation. As Matthew Templeton, AAVSO, states “Variable star data analysis is not always straightforward; large-scale, automated analysis design is non-trivial”. Derekas et al. 2007, Deb et.al. 2010 states “The processing of xvi huge amount of data in these databases is quite challenging, even when looking at seemingly small issues such as period determination and classification”. It will be beneficial for the variable star astronomical community, if basic parameters, such as period, amplitude and phase are obtained more accurately, when huge time series databases are subjected to automation. In the present thesis work, the theories of four popular period search methods are studied, the strength and weakness of these methods are evaluated by applying it on two survey databases and finally a modified form of cubic spline method is intro- duced to confirm the exact period of variable star. For the classification of new variable stars discovered and entering them in the “General Catalogue of Vari- able Stars” or other databases like “Variable Star Index“, the characteristics of the variability has to be quantified in term of variable star parameters.
Resumo:
Nach einem einleitenden ersten Kapitel wird im zweiten Kapitel der Stand der Technik für Regelungs- und Monitoringsysteme mit vernetzten Systemen dargestellt. Daraus wird die Motivation zur Entwicklung neuer, kostengünstiger Systeme abgeleitet. Im dritten Kapitel folgt eine Darstellung der verschiedenen Arten marktverfügbarer Embedded Systems und dafür geeigneter Betriebssysteme. Anforderungen an verteilte Regelungssysteme, unterschiedliche Strukturen dieser Systeme und deren Vor- und Nachteile sind Gegenstand des vierten Kapitels. Anhand von Beispielen aus den Bereichen Erzeugungsmanagement für den Betrieb von KWK-Anlagen, Energieverbrauchsmonitoring und Smart-Metering wird der Einsatz von verteilten Regelungs- und Monitoringsystemen im fünften Kapitel dargestellt. Im folgenden sechsten Kapitel wird die Bedeutung normierter Kommunikation für den Einsatz in verteilten Systemen sowie dafür vorhandene Standards aus der elektrischen Energieversorgungstechnik und der Automatisierungstechnik behandelt. Der Stand der Internet-Technik für verteilte Systeme ist Gegenstand des siebten Kapitels. Dabei werden zunächst die verschiedenen drahtlosen und drahtgebundenen Kommunikationsmedien vorgestellt und ihre Eigenschaften und die Randbedingungen für ihren Einsatz erörtert. Ebenso werden technische Probleme beim Einsatz der Internet-Technik aufgezeigt und Lösungsmöglichkeiten für diese Probleme dargestellt. Es folgt eine Übersicht von Netzwerkdiensten, die für den Betrieb von verteilten Systemen notwendig sind. Außerdem werden Techniken zur Überwachung von verteilten Systemen behandelt. Kapitel acht zeigt Sicherheitsrisiken bei der Nutzung des Internets auf und bewertet verschiedene Techniken zur Absicherung des Netzwerkverkehrs. Kapitel neun stellt ein Internet-basiertes Client-Server-System zur Online-Visualisierung von Anlagendaten im Webbrowser mit Hilfe von Java-Applets und XML-RPC vor. Die Visualisierung von Anlagendaten auf Mobiltelefonen mit Hilfe des Wireless Application Protocol sowie die dafür notwendige Software und Infrastruktur ist Gegenstand des zehnten Kapitels. Im elften Kapitel wird eine neuartige Software für die Simulation von dezentralen Energiesystemen und deren Regelungssystemen auf Basis von virtuellen Maschinen, virtuellen Netzwerken und einer thermischen Simulationsumgebung vorgestellt sowie deren Anwendung für die Reglerentwicklung erklärt. Verschiedene Techniken für die Installation von Betriebssystemen und Software für die Embedded Systems eines verteilten Systems werden im Kapitel zwölf untersucht. Im Kapitel 13 werden verschiedene Technologien zur Konfiguration und Parametrierung von Regelungssystemen in der industriellen Prozess- und Fertigungsautomatisierung hinsichtlich ihrer Eignung für dezentrale Energiesysteme analysiert. Anschließend wird eine Software zur Installation und Parametrierung von Monitoringsystemen sowie der dazugehörigen Infrastruktur vorgestellt. Kapitel 14 beschäftigt sich mit Anforderungen an die Hardware für verteilte Systeme und mit Maßnahmen zur Erhöhung der Betriebs- und der Datensicherheit. Im 15. Kapitel werden die in den bisherigen Kapiteln vorgestellten Techniken anhand eines großen verteilten Monitoringsystems und anhand eines Power Flow and Power Quality Management Systems auf Basis von verteilten Embedded Systems evaluiert. Kapitel 16 fasst die Ergebnisse der Arbeit zusammen und enthält einen Ausblick auf zukünftige Entwicklungen.
Resumo:
The stability of stationary flow of a two-dimensional ice sheet is studied when the ice obeys a power flow law (Glen's flow law). The mass accumulation rate at the top is assumed to depend on elevation and span and the bed supporting the ice sheet consists of an elastic layer lying on a rigid surface. The normal perturbation of the free surface of the ice sheet is a singular eigenvalue problem. The singularity of the perturbation at the front of the ice sheet is considered using matched asymptotic expansions, and the eigenvalue problem is seen to reduce to that with fixed ice front. Numerical solution of the perturbation eigenvalue problem shows that the dependence of accumulation rate on elevation permits the existence of unstable solutions when the equilibrium line is higher than the bed at the ice divide. Alternatively, when the equilibrium line is lower than the bed, there are only stable solutions. Softening of the bed, expressed through a decrease of its elastic modulus, has a stabilising effect on the ice sheet.
Algoritmo genético para seleção de contingências na análise estática de segurança em redes elétricas
Resumo:
Ideally the smile should expose minimal gingival, therefore patients with gummy smile and passive eruption altered or excessive marginal gingivae, usually excessive gingival display because incomplete anatomical crown exposure is present. If the maxillary incisor show at rest is optimal, active upper incisor intrusion should not be iniciated. To achieve a smile with minimal gingival exposure, the anatomic crown should be fully exposed by surgical crown lengthening. Precise determination of the location of cementoenamel junction prior to surgery, precise placement of incisions and correct establish of biological width are necessary in order to achive this goal. One protocol is decribed and clinical results from 15 brazilian subjects, after three years post surgery are showed
Resumo:
Conventional control strategies used in shunt active power filters (SAPF) employs real-time instantaneous harmonic detection schemes which is usually implements with digital filters. This increase the number of current sensors on the filter structure which results in high costs. Furthermore, these detection schemes introduce time delays which can deteriorate the harmonic compensation performance. Differently from the conventional control schemes, this paper proposes a non-standard control strategy which indirectly regulates the phase currents of the power mains. The reference currents of system are generated by the dc-link voltage controller and is based on the active power balance of SAPF system. The reference currents are aligned to the phase angle of the power mains voltage vector which is obtained by using a dq phase locked loop (PLL) system. The current control strategy is implemented by an adaptive pole placement control strategy integrated to a variable structure control scheme (VS-APPC). In the VS-APPC, the internal model principle (IMP) of reference currents is used for achieving the zero steady state tracking error of the power system currents. This forces the phase current of the system mains to be sinusoidal with low harmonics content. Moreover, the current controllers are implemented on the stationary reference frame to avoid transformations to the mains voltage vector reference coordinates. This proposed current control strategy enhance the performance of SAPF with fast transient response and robustness to parametric uncertainties. Experimental results are showing for determining the effectiveness of SAPF proposed control system
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA