903 resultados para Intraaortic Balloon Pump
Resumo:
In order to determine anticoagulation strategies in OPCAB a questionnaire survey among 750 European cardio-thoracic surgeons was performed. Questions addressed volume of OPCAB procedures performed, intra- and perioperative heparinization and antiplatelet therapy, as well as perioperative management. A total of 325 (43.7%) questionnaires were returned and validated. Perioperative protocols for administration of antiplatelets differed among the respondent surgeons. Perioperative prophylaxis of thrombosis (low or high molecular weight heparin) is performed by 78%. Intraoperative heparin dosage range between 70 U/kg to 500 U/kg, 60% of respondents prefer a low-dose regimen (< or = 150 U/kg). Correspondingly, the lowest activated clotting time (ACT) during surgery is accepted to be 200 s by 24%, 250 s by 18% and 300 s by 26% of surgeons. Protamine is used by 91% of respondents, while 52% perform a 1:1 reversal. A cell-saver and antifibrinolytics are used by 70% and 40%, respectively. Interestingly, 56% of respondents think bleeding in OPCAB patients is not reduced when compared to on-pump CABG. In addition, 34% of respondents believe there is an increased risk of early graft occlusion following OPCAB. This survey demonstrates widely different intra- and perioperative anticoagulation strategies for OPCAB procedures among European surgeons.
Resumo:
BACKGROUND: This study analyzes the effects on coagulation and fibrinolysis comparing off-pump coronary artery bypass (OPCAB) and on-pump CABG operations. METHODS: In a prospective, nonrandomized, comparative evaluation, patients scheduled for elective myocardial revascularization were studied. Due to possible confounding factors patients with postoperative retransfusion of mediastinal shed blood were excluded. Nine patients underwent OPCAB operation and 16 underwent on-pump CABG. Activated clotting time (ACT) was adjusted to 250 seconds in OPCAB (81 +/- 18 [mean +/- SD] IU/kg heparin) and to more than 480 seconds in on-pump CABG (400 IU/kg heparin, additional 10,000 IU in pump prime). Perioperatively blood samples were collected and hematologic and hemostatic variables including fibrinopeptide A (FPA), fibrin monomer (FM), thrombin-antithrombin complex (TAT), and D-dimer were analyzed. RESULTS: Both groups showed comparable demographic variables. Number of grafts per patient was slightly higher in the on-pump group (3.6 +/- 0.6 versus 3.0 +/- 1.1, p = 0.23). The FPA levels did not differ significantly between the groups. The FM, TAT, and D-dimer values were significantly higher in on-pump CABG (p < 0.0001, p < 0.01, and p < 0.0001, respectively), reflecting increased coagulant and fibrinolytic activity. This was also the case when values were corrected for hemodilution. CONCLUSIONS: Despite lower systemic anticoagulation activation of coagulation and fibrinolysis is reduced in OPCAB compared with on-pump CABG. Reduced thrombin generation and reduced fibrinolytic activity in OPCAB indicates better preservation of hemostasis. We suggest the term "preserved hemostasis" instead of "hypercoagulant activity" with respect to OPCAB.
Resumo:
We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as on the amount and direction of collateral circulation. This setting allows us to relate CW-NIRS findings to brain specific perfusion changes. We focused our analysis on the transition from normal perfusion to vessel occlusion, i.e., before hypoxia becomes clinically apparent. The localization of the maximal response correlated either with the core (occlusion of the middle cerebral artery) or with the watershed areas (occlusion of the internal carotid artery) of the respective vascular territories. In one patient with clinically and angiographically confirmed insufficient collateral flow during carotid artery occlusion, the total hemoglobin concentration became significantly asymmetric, with decreased values in the ipsilateral watershed area and contralaterally increased values. Multichannel CW-NIRS monitoring might serve as an objective and early predictive marker of critical perfusion changes during interventions-to prevent hypoxic damage of the brain. It also might provide valuable human reference data on oxygenation changes as they typically occur during acute stroke.
Resumo:
In haloarchaea, light-driven ion transporters have been modified by evolution to produce sensory receptors that relay light signals to transducer proteins controlling motility behavior. The proton pump bacteriorhodopsin and the phototaxis receptor sensory rhodopsin II (SRII) differ by 74% of their residues, with nearly all conserved residues within the photoreactive retinal-binding pocket in the membrane-embedded center of the proteins. Here, we show that three residues in bacteriorhodopsin replaced by the corresponding residues in SRII enable bacteriorhodopsin to efficiently relay the retinal photoisomerization signal to the SRII integral membrane transducer (HtrII) and induce robust phototaxis responses. A single replacement (Ala-215-Thr), bridging the retinal and the membrane-embedded surface, confers weak phototaxis signaling activity, and the additional two (surface substitutions Pro-200-Thr and Val-210-Tyr), expected to align bacteriorhodopsin and HtrII in similar juxtaposition as SRII and HtrII, greatly enhance the signaling. In SRII, the three residues form a chain of hydrogen bonds from the retinal's photoisomerized C(13)=C(14) double bond to residues in the membrane-embedded alpha-helices of HtrII. The results suggest a chemical mechanism for signaling that entails initial storage of energy of photoisomerization in SRII's hydrogen bond between Tyr-174, which is in contact with the retinal, and Thr-204, which borders residues on the SRII surface in contact with HtrII, followed by transfer of this chemical energy to drive structural transitions in the transducer helices. The results demonstrate that evolution accomplished an elegant but simple conversion: The essential differences between transport and signaling proteins in the rhodopsin family are far less than previously imagined.
Resumo:
BACKGROUND CONTEXT The Swiss Federal Office of Public Health mandated a nationwide health technology assessment-registry for balloon kyphoplasty (BKP) for decision making on reimbursement of these interventions. The early results of the registry led to a permanent coverage of BKP by basic health insurance. The documentation was continued for further evidence generation. PURPOSE This analysis reports on the 1 year results of patients after BKP treatment. STUDY DESIGN Prospective multicenter observational case series. PATIENT SAMPLE The data on 625 cases with 819 treated vertebrae were documented from March 2005 to May 2012. OUTCOME MEASURES Surgeon-administered outcome instruments were primary intervention form for BKP and the follow-up form; patient self-reported measures were EuroQol-5D questionnaire, North American Spine Society outcome instrument /Core Outcome Measures Index (including visual analog scale), and a comorbidity questionnaire. Outcome measures were back pain, medication, quality of life (QoL), cement extrusions, and new fractures within the first postoperative year. METHODS Data were recorded preoperatively and at 3 to 6-month and 1-year follow-ups. Wilcoxon signed-rank test was used for comparison of pre- with postoperative measurements. Multivariate logistic regression was used to identify factors with a significant influence on the outcome. RESULTS Seventy percent of patients were women with mean age of 71 years (range, 18-91 years); mean age of men was 65 years (range, 15-93 years). Significant and clinically relevant reduction of back pain, improvement of QoL, and reduction of pain killer consumption was seen within the first postoperative year. Preoperative back pain decreased from 69.3 to 29.0 at 3 to 6-month and remained unchanged at 1-year follow-ups. Consequently, QoL improved from 0.23 to 0.71 and 0.75 at the same follow-up intervals. The overall vertebra-based cement extrusion rates with and without extrusions into intervertebral discs were 22.1% and 15.3%, respectively. Symptomatic cement extrusions with radiculopathy were five (0.8%). A new vertebral fracture within a year from the BKP surgery was observed in 18.4% of the patients. CONCLUSIONS The results of the largest observational study for BKP so far are consistent with published randomized trials and systematic reviews. In this routine health care setting, BKP is safe and effective in reducing pain, improving QoL, and lowering pain_killer consumption and has an acceptable rate of cement extrusions. Postoperative outcome results show clear and significant clinical improvement at early follow-up that remain stable during the first postoperative year.
Resumo:
Recently developed technologies allow aortic valve implantation off-pump in a beating heart. In this procedure, the native, stenotic aortic valve is not removed, but simply crushed by a pressure balloon mounted on a percutaneous catheter. Removal of the native aortic cusps before valve replacement may reduce the incidence of annular or cuspal calcium embolization and late perivalvular leaks and increase implantable valve size. However, a temporary valve system in the ascending aorta may be necessary to maintain hemodynamic stability by reducing acute aortic regurgitation and left ventricular volume overload. This study evaluates the hemodynamic effects of a wire-mounted, monoleaflet, temporary valve apparatus in a mechanical cardiovascular simulator. Aortic flow, systemic pressure and left ventricular pressure were continuously monitored. An intraluminal camera obtained real-time proximal and distal images of the valve in operation. Insertion of the parachute valve in the simulator increased diastolic pressure from 7 to 38 mm Hg. Cardiac output increased from 2.08 to 4.66 L/min and regurgitant volume decreased from 65 to 23 mL. In conclusion, placement of a temporary valve in the ascending aorta may help maintain hemodynamic stability and improve off-pump aortic valve replacement.
Resumo:
PURPOSE To assess the extent of early recoil in patients with critical limb ischemia (CLI) undergoing conventional tibial balloon angioplasty. METHODS Our hypothesis was that early recoil, defined as lumen compromise >10%, is frequent and accounts for considerable luminal narrowing after tibial angioplasty, promoting restenosis. To test this theory, 30 consecutive CLI patients (18 men; mean age 76.2±12.1 years) were angiographically evaluated immediately after tibial balloon angioplasty and 15 minutes later. Half the patients were diabetics. Target lesions included anterior and posterior tibial arteries and the peroneal artery with / without the tibioperoneal trunk. Mean tibial lesion length was 83.8 mm. Early elastic recoil was determined on the basis of minimal lumen diameter (MLD) measurements at baseline (MLDbaseline), immediately after tibial balloon angioplasty (MLDpostdilation), and 15 minutes thereafter (MLD15min). RESULTS Elastic recoil was observed in 29 (97%) patients with a mean luminal compromise of 29% according to MLD measurements (MLDbaseline 0.23 mm, MLD postdilation 2.0 mm, and MLD15min 1.47 mm). CONCLUSION Early recoil is frequently observed in CLI patients undergoing tibial angioplasty and may significantly contribute to restenosis. These findings support the role of dedicated mechanical scaffolding approaches for the prevention of restenosis in tibial arteries.