933 resultados para Hydrostatic Tension
Resumo:
The author proposes an approach to string theory where the zero-order theory is the null string. An explicit form of the propagator for the null string in the momentum space is found. Considering the tension as a perturbative parameter, the perturbative series is completely summable and the propagator of the bosonic open string with tension T is found.
Resumo:
Includes bibliography
Resumo:
The effect of high hydrostatic and [001] uniaxial pressures on TiO 2 anatase was studied under the framework of periodic calculations with the inclusion of DFT-D2 dispersion potential adjusted for this system (B3LYP-D*). The role of dispersion in distorted unit cells was evaluated in terms of lattice parameters, elastic constants, equation of state, vibrational properties, and electronic properties (band structure and density of states). A more reliable description at high pressures was achieved because the B3LYP-D* presented an improvement in all properties for undistorted bulk over conventional B3LYP and B3LYP-D. From density of states analysis, we observed that the contribution of crystalline orbitals to the edge of valence and conduction bands changed within applied pressure. The studied distortions can give some insight into behavior of electronic and structural properties due to local stress in anatase bulk from doping, defects, and physical tensions in nanometric forms. © 2013 American Chemical Society.
Resumo:
The influence of high hydrostatic pressure (HHP) on Pêra Rio orange juice was investigated using response surface methodology. A central composite design was used to evaluate the effects of three processing conditions (independent variables), namely pressure (100-600 MPa), temperature (30-60 °C) and time (30-360 s), on the native microflora and pectin methylesterase (PME) activity of orange juice. Analysis of variance showed that second-order polynomial models fitted well with the experimental data for PME residual activity (R2 = 0.9586, p < 0.001) and aerobic microorganism count (R2 = 0.9879, p < 0.001). The optimum HHP processing conditions to produce orange juice with PME residual activity of less than 20 % and low microorganism count (<2 log cycles CFU/mL) were 550 to 600 MPa, 55 to 60 °C and 330 to 360 s. © 2013 Springer Science+Business Media New York.
Resumo:
Background. Reduced surface tension of liquids results in higher surface wetting ability and diffusivity by the substrate. Objectives. The objective of this study was to evaluate the influence of the Grander Technology in reducing the surface tension of adhesive systems. Methods. Two adhesive systems (self-etch and total-etch) were modified by physical contact with the Grander system Flexible unit to revitalize water, for 48 h. Surface tension of adhesive systems and water in normal and grander-modified conditions was measured with a goniometer. Results. The results showed a reduction of surface tension for all conditions grander-modified between 3-15%. Conclusions. Grander Technology was effective in reducing the surface tension of the Single Bond and Clearfil SE Bond adhesive systems. Clinical significance. Grander technology was employed to restructure the molecular structure of water-based adhesive systems, which can increase their wetness capacity and therefore ensure a greater diffusibility.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Periodically, when necessary, standard documents are revised in order to analyze inconsistencies and to include considerations according new realities verified. In this sense, aiming to quantify the wood moisture content influence on modulus of elasticity, it was applied tension tests parallel to the grain for six specimens of different strength classes of wood, considering nominal moisture of 12, 20, 25, and 30% in Brazil. The present paper examine the adequacy of the current Brazilian standard ABNT NBR7190:1997, in review, about the adoption of a first degree equation to describe the influence of wood moisture content for timber structures design. It was obtained a new first degree equation which leads to statically equivalent estimations when compared with results by ABNT NBR7190:1997 equation. However, as recommendations it could be maintain the current expression for the next text of the referred document review, without prejudice to statistical significance of the estimates.
Resumo:
OBJECTIVES: Hemodynamic support is aimed at providing adequate O-2 delivery to the tissues; most interventions target O-2 delivery increase. Mixed venous O-2 saturation is a frequently used parameter to evaluate the adequacy of O-2 delivery. METHODS: We describe a mathematical model to compare the effects of increasing O-2 delivery on venous oxygen saturation through increases in the inspired O-2 fraction versus increases in cardiac output. The model was created based on the lungs, which were divided into shunted and non-shunted areas, and on seven peripheral compartments, each with normal values of perfusion, optimal oxygen consumption, and critical O-2 extraction rate. O-2 delivery was increased by changing the inspired fraction of oxygen from 0.21 to 1.0 in steps of 0.1 under conditions of low (2.0 L.min(-1)) or normal (6.5 L.min(-1)) cardiac output. The same O-2 delivery values were also obtained by maintaining a fixed O-2 inspired fraction value of 0.21 while changing cardiac output. RESULTS: Venous oxygen saturation was higher when produced through increases in inspired O-2 fraction versus increases in cardiac output, even at the same O-2 delivery and consumption values. Specifically, at high inspired O-2 fractions, the measured O-2 saturation values failed to detect conditions of low oxygen supply. CONCLUSIONS: The mode of O-2 delivery optimization, specifically increases in the fraction of inspired oxygen versus increases in cardiac output, can compromise the capability of the "venous O-2 saturation" parameter to measure the adequacy of oxygen supply. Consequently, venous saturation at high inspired O-2 fractions should be interpreted with caution.
Resumo:
Cornachione AS, Rassier DE. A non-cross-bridge, static tension is present in permeabilized skeletal muscle fibers after active force inhibition or actin extraction. Am J Physiol Cell Physiol 302: C566-C574, 2012. First published November 16, 2011; doi: 10.1152/ajpcell.00355.2011.-When activated muscle fibers are stretched, there is a long-lasting increase in the force. This phenomenon, referred to as "residual force enhancement," has characteristics similar to those of the " static tension," a long-lasting increase in force observed when muscles are stretched in the presence of Ca2+ but in the absence of myosin-actin interaction. Independent studies have suggested that these two phenomena have a common mechanism and are caused either by 1) a Ca2+-induced stiffening of titin or by 2) promoting titin binding to actin. In this study, we performed two sets of experiments in which activated fibers (pCa(2+) 4.5) treated with the myosin inhibitor blebbistatin were stretched from 2.7 to 2.8 mu m at a speed of 40 L-o/s, first, after partial extraction of TnC, which inhibits myosin-actin interactions, or, second, after treatment with gelsolin, which leads to the depletion of thin (actin) filaments. We observed that the static tension, directly related with the residual force enhancement, was not changed after treatments that inhibit myosin-actin interactions or that deplete fibers from troponin C and actin filaments. The results suggest that the residual force enhancement is caused by a stiffening of titin upon muscle activation but not with titin binding to actin. This finding indicates the existence of a Ca2+-regulated, titin-based stiffness in skeletal muscles.
Resumo:
There is no reason for Dentistry to use different terms for phenomena defined in Physics, the specific field in which concepts associated with forces are established and adapted. In place of pressure/tension, the compression/traction pair should be used. This study defines each one of these terms and justifies their use. Our contemporary world demands standardized criteria, methods, measures, concepts and terms to ensure that study protocols, results and applications are used in the same way in any country or area of human action.