999 resultados para Harmonist Therapy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

According to the operation and development of radiation therapy in the world, in order to further promote the radiation therapy of tumour in China, a design of a special synchrotron with two super-periodicity for hadron therapy is presented, including lattice, injection system, RF acceleration and slow extraction of the third order resonance. The synchrotron accelerates the proton beam to 250MeV and the carbon beam to 4000MeV/u.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Basic research related to heavy-ion cancer therapy has been done at the Institute of Modern Physics (IMP), Chinese Academy of Sciences since 1995. Now a plan of clinical trial with heavy ions has been launched at IMP. First, superficially placed tumor treatment with heavy ions is expected in the therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL), where carbon ion beams with energy up to 100 MeV/u can be supplied. The shallow-seated tumor therapy terminal at HIRFL is equipped with a passive beam delivery system including two orthogonal dipole magnets, which continuously scan pencil beams laterally and generate a broad and uniform irradiation field, a motor-driven energy degrader and a multi-leaf collimator. Two different types of range modulator, ripple filter and ridge filter with which Guassian-shaped physical dose and uniform biological effective dose Bragg peaks can be shaped for therapeutic ion beams respectively, have been designed and manufactured. Therefore, two-dimensional and three-dimensional conformal irradiations to tumors can be performed with the passive beam delivery system at the earlier therapy terminal. Both the conformal irradiation methods have been verified experimentally and carbon-ion conformal irradiations to patients with superficially placed tumors have been carried out at HIRFL since November 2006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The passive beam delivery system in the superficially-placed tumor therapy terminal at Heavy Ion Researc h Facility in Lanzhou (HIRFL), which includes two orthogonal dipole magnets as scanning system, a motor-driven energy degrader as range-shifter, series of ridge filters as range modulator and a multileaf collimator, is introduced in detail. The capacities of its important components and the whole system have been verified experimentally. The tests of the ridge filter for extending Bragg peak and the range shifter for energy adjustment show both work well. To examine the passive beam delivery system, a beam shaping experiment were carried out, simulating a three-dimensional (3D) conformal irradiation to a tumor. The encouraging experimental result confirms that 3D layer-stacking conformal irradiation can be performed by means of the passive system. The validation of the beam delivery system establishes a substantial basis for upcoming clinical trial for superficially-placed tumors with heavy ions in the therapy terminal at HIRFL.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The combination of ionizing radiation and gene therapy has been investigated. However, there are very few reports about the combination of heavy-ion irradiation and gene therapy. To determine if the pre-exposure to low-dose heavy ion beam enhances the suppression of AdCMV-p53 on non-small lung cancer (NSLC), the cells pre-irradiated or non-irradiated were infected with 20, 40 MOI of AdCMV-p53. Survival fraction and the relative biology effect (RBE) were determined by clonogenic assay. The results showed that the proportions of p53 positive cells in C-12(6+) beam induced AdCMV-p53 infected cells were more than 90%, which were significantly more than those in gamma-ray induced AdCMV-p53 infected cells. The pre-exposure to low-dose 12C6+ beam significantly prevented the G(0)/G(1) arrest and activated G(2)/M checkpoints. The pre-exposure to C-12(6+) beam significantly improved cell to apoptosis. RBEs for the C-12(6+)+ AdCMV-p53 infection groups were 30%-60%,20% -130% and 30%-70% more than those for the C-12(6+)_irradiated only, AdCMV-p53 infected only, and gamma-irradiation induced AdCMVp53 infected groups, respectively. The data suggested that the pre-exposure to low-dose C-12(6+) beam significantly promotes exogenous p53 expression in NSLC, and the suppression of AdCMV-p53 gene therapy on NSLC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For the first time the physical properties of therapeutic carbon-ion beam supplied by, the shallow-seated tumor therapy terminal at the Heavy Ion Research Facility in Lanzhou (HIRFL) are measured. For a 80.55MeV/u C-12 ion beam delivered to the therapy terminal, the homogeneity of irradiation fields is 73.48%, when the beam intensity varied in the range of 0.001-0.1nA (i.e. 1 X 10(6) - 1 X 10(8) particles per second). The stability of the beam intensity within a few minutes is estimated to be 80.87%. The depth-dose distribution of the beam at the isocenter of the therapy facility is measured, and the position of the high-dose Bragg peak is found to be located at the water-equivalent depth of 13.866mm. Based on the relationship between beam energy and Bragg peak position, the corresponding beam energy at the isocenter of the therapy terminal is evaluated to be 71.71MeV/u for the original 80.55MeV/u C-12 ion beam, which consisted basically with calculation. The readout of the previously-used air-free ionization chamber regarding absorbed dose is calibrated as well in this experiment. The results indicate that the performance of the therapy facility should be optimized further to meet the requirements of clinical trial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The clinical trials of tumor therapy using heavy ions beam C-12 are now in progress at Institute of Modem Physics in Lanzhou. In order to achieve the precise radiotherapy with the high energy C-12 beam in active pencil beam scanning mode, we have developed an ionization chamber(IC) as an online monitor for beam intensity and also a dosimeter after calibration. Through the choosing of working gas and voltage, optimizing of the electrics and the read-out system, calibrating the linearity, the detector system provide us one of the simple and highly reliable way to monitoring the beam during the active pencil beam scanning treatments. The measurement results of this detector system show that it could work well under the condition of high energy C-12 beam in active pencil beam scanning mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

癌症是现代医学的难题,一直危害着人类的健康。放射治疗是癌症治疗的有效手段之一。由于重离子束在物理学和生物学性质上所具有的优势,它已成为放疗用的最佳射线。简述了重离子治癌的发展历程、现状以及特点,详细讨论了在医学物理和放射生物学研究领域值得关注的若干热点问题。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

介绍了中国科学院近代物理研究所重离子治癌装置的安装定位测量技术和方法。利用激光跟踪仪通过控制网的建立,和多重坐标系的转换,使最后的磁铁安装径向相对误差不超过±(0.05-0.1)mm,真空管道的横向及竖向精度也达到了±(0.1-0.2)mm。

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For radiation protection purposes, the neutron dose in carbon ion radiation therapy at the HIRFL (Heavy Ion Research Facility in Lanzhou) was investigated. The neutron dose from primary C-12 ions with a specific energy of 100 MeV/u delivered from SSC was roughly measured with a standard Anderson-Broun rem-meter using a polyethylene target at various distances. The result shows that a maximum neutron dose contribution of 19 mSv in a typically surface tumor treatment was obtained, which is less than 1% of the planed heavy ion dose and is in reasonable agreement with other reports. Also the gamma-ray dose was measured in this experiment using a thermo luminescent detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tangential flow affinity membrane cartridge (TFAMC) fs a new model of immunoadsorption therapy for hemoperfusion. Recombinant Protein A was immobilized on the membrane cartridge through Schiff base formation for extracorporeal IgG and immune complex removal from blood. Flow characteristics, immunoadsorption capacity and biocompatibility of protein A TFAMC were studied. The results showed that the pressure drop increased with the increasing flow rate of water, plasma and blood, demonstrating reliable strength of membrane at high now rare. The adsorption capacities of protein A TFAMC for IgG from human plasma and blood were measured. The cartridge with 139 mg protein A immobilized on the matrix (6 mg protein A/g dry matrix) adsorbed 553 mg IgG (23.8 mg IgG/g dry matrix) from human plasma and 499.4 mg IgG (21.5 mg IgG/g dry matrix) from human blood, respectively. The circulation time had a major influence on IgG adsorption capacity, but the flow rate had little influence. Experiments in vitro and in vivo confirmed that protein A TFAMC mainly adsorbed Ige and Little of other plasma proteins, and that blood cell damage was negligible. The extracorporeal circulation system is safe and reliable. Copyright (C) 1999 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The phototherapy effects in the skin are related to biomodulation, usually to accelerate wound healing. However, there is no direct proof of the interrelation between the effects of low-level laser therapy (LLLT) and light-emitting diode (LED) in neuropeptide secretion, these substances being prematurely involved in the neurogenic inflammation phase of wound healing. This study therefore focused on investigating LLLT and LED in Calcitonin gene-related peptide (CGRP) and substance P (SP) secretion in healthy rat skin. Forty rats were randomly distributed into five groups with eight rats each: Control Group, Blue LED Group (470 nm, 350 mW power), Red LED Group (660 nm, 350 mW power), Red Laser Group (660 nm, 100 mW power), and Infrared Laser Group (808 nm, 100 mW power) (DMCA (R) Equipamentos Ltda., So Carlos, So Paulo, Brazil). the skin of the animals in the experimental groups was irradiated using the punctual contact technique, with a total energy of 40 J, single dose, standardized at one point in the dorsal region. After 14 min of irradiation, the skin samples were collected for CGRP and SP quantification using western blot analysis. SP was released in Infrared Laser Group (p = 0.01); there was no difference in the CGRP secretion among groups. Infrared (808 nm) LLLT enhances neuropeptide SP secretion in healthy rat skin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Ototoxicity is a known side effect of combined radiation therapy and cisplatin chemotherapy for the treatment of medulloblastoma. the delivery of an involved field boost by intensity modulated radiation therapy (IMRT) may reduce the dose to the inner ear when compared with conventional radiotherapy. the dose of cisplatin may also affect the risk of ototoxicity. A retrospective study was performed to evaluate the impact of involved field boost using IMRT and cisplatin dose on the rate of ototoxicity.Methods: Data from 41 medulloblastoma patients treated with IMRT were collected. Overall and disease-free survival rates were calculated by Kaplan-Meier method Hearing function was graded according to toxicity criteria of Pediatric Oncology Group (POG). Doses to inner ear and total cisplatin dose were correlated with hearing function by univariate and multivariate data analysis.Results: After a mean follow-up of 44 months (range: 14 to 72 months), 37 patients remained alive, with two recurrences, both in spine with CSF involvement, resulting in a disease free-survival and overall survival of 85.2% and 90.2%, respectively. Seven patients (17%) experienced POG Grade 3 or 4 toxicity. Cisplatin dose was a significant factor for hearing loss in univariate analysis (p < 0.03). in multivariate analysis, median dose to inner ear was significantly associated with hearing loss (p < 0.01). POG grade 3 and 4 toxicity were uncommon with median doses to the inner ear bellow 42 Gy (p < 0.05) and total cisplatin dose of less than 375 mg/m(2) (p < 0.01).Conclusions: IMRT leads to a low rate of severe ototoxicity. Median radiation dose to auditory apparatus should be kept below 42 Gy. Cisplatin doses should not exceed 375 mg/m(2).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The issue of unhelpful and harmful therapy outcome has received an increasing amount of attention within the research literature in recent years. However, little research exists on the client's perspective of what constitutes unhelpful therapy. Aim: The aim of this study was to explore clients’ experiences of unhelpful therapy. Method: Semi-structured interviews were carried out with ten therapists who, as clients, experienced unhelpful therapy. Interview transcripts were analysed using interpretative phenomenological analysis. Findings: Participants recounted therapy episodes characterised by an absence of negotiation, collaboration and care; pivotal moments when they knew that they would not return; and ongoing negative effects. Conclusions: The findings of this study have implications for training and strategies for supporting clients who have been harmed by therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paper published in PLoS Medicine in 2007.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Rationing of access to antiretroviral therapy already exists in sub-Saharan Africa and will intensify as national treatment programs develop. The number of people who are medically eligible for therapy will far exceed the human, infrastructural, and financial resources available, making rationing of public treatment services inevitable. Methods: We identified 15 criteria by which antiretroviral therapy could be rationed in African countries and analyzed the resulting rationing systems across 5 domains: clinical effectiveness, implementation feasibility, cost, economic efficiency, and social equity. Findings: Rationing can be explicit or implicit. Access to treatment can be explicitly targeted to priority subpopulations such as mothers of newborns, skilled workers, students, or poor people. Explicit conditions can also be set that cause differential access, such as residence in a designated geographic area, co-payment, access to testing, or a demonstrated commitment to adhere to therapy. Implicit rationing on the basis of first-come, first-served or queuing will arise when no explicit system is enforced; implicit systems almost always allow a high degree of queue-jumping by the elite. There is a direct tradeoff between economic efficiency and social equity. Interpretation: Rationing is inevitable in most countries for some period of time. Without deliberate social policy decisions, implicit rationing systems that are neither efficient nor equitable will prevail. Governments that make deliberate choices, and then explain and defend those choices to their constituencies, are more likely to achieve a socially desirable outcome from the large investments now being made than are those that allow queuing and queue-jumping to dominate.