971 resultados para Fluid dynamic measurements.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper deals with fault detection and isolation problems for nonlinear dynamic systems. Both problems are stated as constraint satisfaction problems (CSP) and solved using consistency techniques. The main contribution is the isolation method based on consistency techniques and uncertainty space refining of interval parameters. The major advantage of this method is that the isolation speed is fast even taking into account uncertainty in parameters, measurements, and model errors. Interval calculations bring independence from the assumption of monotony considered by several approaches for fault isolation which are based on observers. An application to a well known alcoholic fermentation process model is presented

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of a model-based diagnosis system could be affected by several uncertainty sources, such as,model errors,uncertainty in measurements, and disturbances. This uncertainty can be handled by mean of interval models.The aim of this thesis is to propose a methodology for fault detection, isolation and identification based on interval models. The methodology includes some algorithms to obtain in an automatic way the symbolic expression of the residual generators enhancing the structural isolability of the faults, in order to design the fault detection tests. These algorithms are based on the structural model of the system. The stages of fault detection, isolation, and identification are stated as constraint satisfaction problems in continuous domains and solved by means of interval based consistency techniques. The qualitative fault isolation is enhanced by a reasoning in which the signs of the symptoms are derived from analytical redundancy relations or bond graph models of the system. An initial and empirical analysis regarding the differences between interval-based and statistical-based techniques is presented in this thesis. The performance and efficiency of the contributions are illustrated through several application examples, covering different levels of complexity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A collection of 24 seawaters from various worldwide locations and differing depth was culled to measure their chlorine isotopic composition (delta(37)Cl). These samples cover all the oceans and large seas: Atlantic, Pacific, Indian and Antarctic oceans, Mediterranean and Red seas. This collection includes nine seawaters from three depth profiles down to 4560 mbsl. The standard deviation (2sigma) of the delta(37)Cl of this collection is +/-0.08 parts per thousand, which is in fact as large as our precision of measurement ( +/- 0.10 parts per thousand). Thus, within error, oceanic waters seem to be an homogeneous reservoir. According to our results, any seawater could be representative of Standard Mean Ocean Chloride (SMOC) and could be used as a reference standard. An extended international cross-calibration over a large range of delta(37)Cl has been completed. For this purpose, geological fluid samples of various chemical compositions and a manufactured CH3Cl gas sample, with delta(37)Cl from about -6 parts per thousand to +6 parts per thousand have been compared. Data were collected by gas source isotope ratio mass spectrometry (IRMS) at the Paris, Reading and Utrecht laboratories and by thermal ionization mass spectrometry (TIMS) at the Leeds laboratory. Comparison of IRMS values over the range -5.3 parts per thousand to +1.4 parts per thousand plots on the Y=X line, showing a very good agreement between the three laboratories. On 11 samples, the trend line between Paris and Reading Universities is: delta(37)Cl(Reading)= (1.007 +/- 0.009)delta(37)Cl(Paris) - (0.040 +/- 0.025), with a correlation coefficient: R-2 = 0.999. TIMS values from Leeds University have been compared to IRMS values from Paris University over the range -3.0 parts per thousand to +6.0 parts per thousand. On six samples, the agreement between these two laboratories, using different techniques is good: delta(37)Cl(Leeds)=(1.052 +/- 0.038)delta(37)Cl(Paris) + (0.058 +/- 0.099), with a correlation coefficient: R-2 = 0.995. The present study completes a previous cross-calibration between the Leeds and Reading laboratories to compare TIMS and IRMS results (Anal. Chem. 72 (2000) 2261). Both studies allow a comparison of IRMS and TIMS techniques between delta(37)Cl values from -4.4 parts per thousand to +6.0 parts per thousand and show a good agreement: delta(37)Cl(TIMS)=(1.039 +/- 0.023)delta(37)Cl(IRMS)+(0.059 +/- 0.056), with a correlation coefficient: R-2 = 0.996. Our study shows that, for fluid samples, if chlorine isotopic compositions are near 0 parts per thousand, their measurements either by IRMS or TIMS will give comparable results within less than +/- 0.10 parts per thousand, while for delta(37)Cl values as far as 10 parts per thousand (either positive or negative) from SMOC, both techniques will agree within less than +/- 0.30 parts per thousand. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An improved amplifier for atmospheric fine wire resistance thermometry is described. The amplifier uses a low excitation current (50 mu A). This is shown to ensure negligible self-heating of the low mass fine wire resistance sensor, compared with measured nocturnal surface air temperature fluctuations. The system provides sufficient amplification for a +/- 50 degrees C span using a +/- 5 V dynamic range analog-to-digital converter, with a noise level of less than 0.01 degrees C. A Kelvin four-wire connection cancels the effect of long lead resistances: a 50 m length of screened cable connecting the Reading design of fine wire thermometer to the amplifier produced no measurable temperature change at 12 bit resolution.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flavonoid extracts derived from plant foods have been shown to benefit certain types of fluid retention. However, no studies have investigated these compounds for use in premenstrual fluid retention, a complaint common among women with otherwise normal menstrual cycles. Therefore, we conducted a double-blind, placebo-controlled, pilot study into the effect of a daily flavonoid extract (Colladeen(R), 320 mg oligomeric procyanidins) on premenstrual fluid retention. Fluid retention was assessed at baseline and throughout 4 menstrual cycles of the intervention using validated questionnaires. Leg girth was also measured at baseline and at the end of the study. Thirty subjects completed the study (n = 18 active treatment; n = 12 placebo). Although no significant changes in leg girth measurements were noted, there was a significant improvement in subjective "leg health" scores after flavonoid treatment compared to placebo (p = 0.013). Furthermore, this was accompanied by an improvement in reported premenstrual fluid retention nearing significance (p = 0.066). We conclude that flavonoids supplements may provide a new therapeutic direction to counter premenstrual fluid retention and improve leg health. A larger study is now warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper discusses experimental and theoretical investigations and Computational Fluid Dynamics (CFD) modelling considerations to evaluate the performance of a square section wind catcher system connected to the top of a test room for the purpose of natural ventilation. The magnitude and distribution of pressure coefficients (C-p) around a wind catcher and the air flow into the test room were analysed. The modelling results indicated that air was supplied into the test room through the wind catcher's quadrants with positive external pressure coefficients and extracted out of the test room through quadrants with negative pressure coefficients. The air flow achieved through the wind catcher depends on the speed and direction of the wind. The results obtained using the explicit and AIDA implicit calculation procedures and CFX code correlate relatively well with the experimental results at lower wind speeds and with wind incidents at an angle of 0 degrees. Variation in the C-p and air flow results were observed particularly with a wind direction of 45 degrees. The explicit and implicit calculation procedures were found to be quick and easy to use in obtaining results whereas the wind tunnel tests were more expensive in terms of effort, cost and time. CFD codes are developing rapidly and are widely available especially with the decreasing prices of computer hardware. However, results obtained using CFD codes must be considered with care, particularly in the absence of empirical data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Molecular size and structure of the gluten polymers that make up the major structural components of wheat are related to their rheological properties via modem polymer rheology concepts. Interactions between polymer chain entanglements and branching are seen to be the key mechanisms determining the rheology of HMW polymers. Recent work confirms the observation that dynamic shear plateau modulus is essentially independent of variations in MW amongst wheat varieties of varying baking performance and is not related to variations in baking performance, and that it is not the size of the soluble glutenin polymers, but the structural and rheological properties of the insoluble polymer fraction that are mainly responsible for variations in baking performance. The rheological properties of gas cell walls in bread doughs are considered to be important in relation to their stability and gas retention during proof and baking, in particular their extensional strain hardening properties. Large deformation rheological properties of gas cell walls were measured using biaxial extension for a number of doughs of varying breadmaking quality at constant strain rate and elevated temperatures in the range 25-60 degrees C. Strain hardening and failure strain of cell walls were both seen to decrease with temperature, with cell walls in good breadmaking doughs remaining stable and retaining their strain hardening properties to higher temperatures (60 degrees C), whilst the cell walls of poor breadmaking doughs became unstable at lower temperatures (45-50 degrees C) and had lower strain hardening. Strain hardening measured at 50 degrees C gave good correlations with baking volume, with the best correlations achieved between those rheological measurements and baking tests which used similar mixing conditions. As predicted by the Considere failure criterion, a strain hardening value of I defines a region below which gas cell walls become unstable, and discriminates well between the baking quality of a range of commercial flour blends of varying quality. This indicates that the stability of gas cell walls during baking is strongly related to their strain hardening properties, and that extensional rheological measurements can be used as predictors of baking quality. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Flavonoid extracts derived from plant foods have been shown to benefit certain types of fluid retention. However, no studies have investigated these compounds for use in premenstrual fluid retention, a complaint common among women with otherwise normal menstrual cycles. Therefore, we conducted a double-blind, placebo-controlled, pilot study into the effect of a daily flavonoid extract (Colladeen(R), 320 mg oligomeric procyanidins) on premenstrual fluid retention. Fluid retention was assessed at baseline and throughout 4 menstrual cycles of the intervention using validated questionnaires. Leg girth was also measured at baseline and at the end of the study. Thirty subjects completed the study (n = 18 active treatment; n = 12 placebo). Although no significant changes in leg girth measurements were noted, there was a significant improvement in subjective "leg health" scores after flavonoid treatment compared to placebo (p = 0.013). Furthermore, this was accompanied by an improvement in reported premenstrual fluid retention nearing significance (p = 0.066). We conclude that flavonoids supplements may provide a new therapeutic direction to counter premenstrual fluid retention and improve leg health. A larger study is now warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Measured process data normally contain inaccuracies because the measurements are obtained using imperfect instruments. As well as random errors one can expect systematic bias caused by miscalibrated instruments or outliers caused by process peaks such as sudden power fluctuations. Data reconciliation is the adjustment of a set of process data based on a model of the process so that the derived estimates conform to natural laws. In this paper, techniques for the detection and identification of both systematic bias and outliers in dynamic process data are presented. A novel technique for the detection and identification of systematic bias is formulated and presented. The problem of detection, identification and elimination of outliers is also treated using a modified version of a previously available clustering technique. These techniques are also combined to provide a global dynamic data reconciliation (DDR) strategy. The algorithms presented are tested in isolation and in combination using dynamic simulations of two continuous stirred tank reactors (CSTR).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increasing demand for ecosystem services, in conjunction with climate change, is expected to signif- icantly alter terrestrial ecosystems. In order to evaluate the sustainability of land and water resources, there is a need for a better understanding of the relationships between crop production, land surface characteristics and the energy and water cycles. These relationships are analysed using the Joint UK Land Environment Simulator (JULES). JULES includes the full hydrological cycle and vegetation effects on the energy, water, and carbon fluxes. However, this model currently only simulates land surface processes in natural ecosystems. An adapted version of JULES for agricultural ecosystems, called JULES-SUCROS has therefore been developed. In addition to overall model improvements, JULES-SUCROS includes a dynamic crop growth structure that fully fits within and builds upon the biogeochemical modelling framework for natural vegetation. Specific agro-ecosystem features such as the development of yield-bearing organs and the phenological cycle from sowing till harvest have been included in the model. This paper describes the structure of JULES-SUCROS and evaluates the fluxes simulated with this model against FLUXNET measurements at 6 European sites. We show that JULES-SUCROS significantly improves the correlation between simulated and observed fluxes over cropland and captures well the spatial and temporal vari- ability of the growth conditions in Europe. Simulations with JULES-SUCROS highlight the importance of vegetation structure and phenology, and the impact they have on land–atmosphere interactions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a new approach to determine palaeotemperatures (mean annual surface temperatures) based on measurements of the liquid–vapour homogenisation temperature of fluid inclusions in stalagmites. The aim of this study is to explore the potential and the limitations of this new palaeothermometer and to develop a reliable methodology for routine applications in palaeoclimate research. Therefore, we have investigated recent fluid inclusions from the top part of actively growing stalagmites that have formed at temperatures close to the present-day cave air temperature. A precondition for measuring homogenisation temperatures of originally monophase inclusions is the nucleation of a vapour bubble by means of single ultra-short laser pulses. Based on the observed homogenisation temperatures (Th(obs)) and measurements of the vapour bubble diameter at a known temperature, we calculated stalagmite formation temperatures (Tf) by applying a thermodynamic model that takes into account the effect of surface tension on liquid–vapour homogenisation. Results from recent stalagmite samples demonstrate that calculated stalagmite formation temperatures match the present-day cave air temperature within ± 0.2 °C. To avoid artificially induced changes of the fluid density we defined specific demands on the selection, handling and preparation of the stalagmite samples. Application of the method is restricted to stalagmites that formed at cave temperatures greater than ~ 9–11 °C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present a dynamic causal model that can explain context-dependent changes in neural responses, in the rat barrel cortex, to an electrical whisker stimulation at different frequencies. Neural responses were measured in terms of local field potentials. These were converted into current source density (CSD) data, and the time series of the CSD sink was extracted to provide a time series response train. The model structure consists of three layers (approximating the responses from the brain stem to the thalamus and then the barrel cortex), and the latter two layers contain nonlinearly coupled modules of linear second-order dynamic systems. The interaction of these modules forms a nonlinear regulatory system that determines the temporal structure of the neural response amplitude for the thalamic and cortical layers. The model is based on the measured population dynamics of neurons rather than the dynamics of a single neuron and was evaluated against CSD data from experiments with varying stimulation frequency (1–40 Hz), random pulse trains, and awake and anesthetized animals. The model parameters obtained by optimization for different physiological conditions (anesthetized or awake) were significantly different. Following Friston, Mechelli, Turner, and Price (2000), this work is part of a formal mathematical system currently being developed (Zheng et al., 2005) that links stimulation to the blood oxygen level dependent (BOLD) functional magnetic resonance imaging (fMRI) signal through neural activity and hemodynamic variables. The importance of the model described here is that it can be used to invert the hemodynamic measurements of changes in blood flow to estimate the underlying neural activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are well-known difficulties in making measurements of the moisture content of baked goods (such as bread, buns, biscuits, crackers and cake) during baking or at the oven exit; in this paper several sensing methods are discussed, but none of them are able to provide direct measurement with sufficient precision. An alternative is to use indirect inferential methods. Some of these methods involve dynamic modelling, with incorporation of thermal properties and using techniques familiar in computational fluid dynamics (CFD); a method of this class that has been used for the modelling of heat and mass transfer in one direction during baking is summarized, which may be extended to model transport of moisture within the product and also within the surrounding atmosphere. The concept of injecting heat during the baking process proportional to the calculated heat load on the oven has been implemented in a control scheme based on heat balance zone by zone through a continuous baking oven, taking advantage of the high latent heat of evaporation of water. Tests on biscuit production ovens are reported, with results that support a claim that the scheme gives more reproducible water distribution in the final product than conventional closed loop control of zone ambient temperatures, thus enabling water content to be held more closely within tolerance.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, computational fluid dynamics (CFD) has been widely used as a method of simulating airflow and addressing indoor environment problems. The complexity of airflows within the indoor environment would make experimental investigation difficult to undertake and also imposes significant challenges on turbulence modelling for flow prediction. This research examines through CFD visualization how air is distributed within a room. Measurements of air temperature and air velocity have been performed at a number of points in an environmental test chamber with a human occupant. To complement the experimental results, CFD simulations were carried out and the results enabled detailed analysis and visualization of spatial distribution of airflow patterns and the effect of different parameters to be predicted. The results demonstrate the complexity of modelling human exhalation within a ventilated enclosure and shed some light into how to achieve more realistic predictions of the airflow within an occupied enclosure.