369 resultados para Dinamômetro hidráulico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study describes the preliminary design of a static skip compactor and its hydraulic system. The objective of this study is to develop and to improve the design of a made project. The methodology used in this study was to analyze the faults of the already done projects and to suggest possible improvements. The result is a preliminary design of a skip with the main necessary dimensions and specifications to build that equipment. The conclusion of this study is a preliminary project of simple equipment that makes in very efficient way its work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Disposição construtiva aplicada em cadeira antropométrica. Patente de modelo de utilidade para uma cadeira antropométrica constituída de uma estrutura (1) que sustenta uma pluralidade de instrumentos de medição, sendo que a parte posterior da cadeira é provida de dois instrumentos de medição compostos por duas hastes, sendo uma delas para medida da altura tronco-encefálica (2) e a outra para a medida do assento até a região renal (4), de modo que cada uma dessas hastes possui uma escala numérica, sendo ora interna (3), ora externa (5). O assento (6) da cadeira (1) é composto por um anteparo com uma canaleta interna e dois cursores laterais deslizantes para a direita e para a esquerda, que possuem escala numérica.; O assento é provido de referências métricas sendo uma no sentido da largura do assento (8) e outra no sentido da profundidade do assento (9), sendo a escala (8) dividida em duas escalas, onde o ponto zero é exatamente o meio do assento. O assento (6) também possui acoplada uma haste frontal, com deslizamento no sentido antero-posterior (10), a qual contém uma escala interna embutida na peça, de modo que a soma entre a medida da profundidade do assento com a medida obtida pela haste deslizante horizontal (10) totalizam a medida sacro-poplítea. Para a tomada da medida da altura poplítea, há uma outra haste (11), integrada à superfície anterior da cadeira, cujo deslizamento é vertical, sendo que essa haste (11) possui uma escala numérica interna uma externa (12).; A base da cadeira (13) possui um dispositivo de acionamento lateral com o pé (16), que é conectado ao assento (6) por meio de um macaco hidráulico, permitindo a elevação do assento, sendo que a outra alavanca (17), ao ser girada, realiza a descida do assento (6).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A força de preensão manual tem sido relatada como determinante no desempenho de empunhadura em modalidades como lutas e escalada. Este estudo teve por propósito avaliar a aptidão de força isotônica máxima e de preensão manual em praticantes e não praticantes de montaria em touros, a fim de obter parâmetros de referência desta população. Foram avaliados 20 sujeitos em dois grupos, sendo 10 classificados como atletas de montaria e 10 não-atletas. A avaliação da força de preensão manual foi realizada em dinamômetro em posição convencional (DP) e específica (DE), com ambas as mãos (D e E). A força isotônica máxima foi determinada pelo teste de uma repetição máxima (1RM) e também foram obtidas medidas de circunferência dos segmentos, bem como a composição corporal por protocolo de dobras cutâneas. Os valores das variáveis foram comparados pelo teste-t (ρ ≤ 0,05) para dados independentes. As relações entre os valores de força e características antropométricas foram traçadas pelo coeficiente de Pearson. Os resultados para AMT em DPD (43.8±6.8 kgf), DPE (39.4±7.7 kgf), DED (44.9±5.6 kgf) e DEE (39.8±8.3 kgf) comparados aos apresentados por n-AMT em DPD (47.0±3.0 kgf), DPE (42.2±6.1 kgf), DED (49.2±1.5 kgf) e DEE (46.2±4.1 kgf) apresentaram diferenças apenas para DED e DEE. A força nos testes de 1RM (supino reto: 73.2±12.0 kg e 82.0±12.0 kg; rosca direta: 45.2±8.9 kg e 43.8±8.9 kg; tríceps pulley: 67.0±6.3 kg e 72.0±6.3 kg; e puxada posterior: 73.5±8.5 kg e 73.7±7.5 kg) não mostram diferenças entre os grupos. A influência sobre a dinamometria apresenta-se diferente entre os grupos, sendo relevante a força de flexão do cotovelo em AMT e a antropometria e força isotônica para n-AMT. Conclui-se que as características morfo-funcionais de membros superiores não demandam especificidade à montaria em touros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A força de preensão manual tem sido relatada como determinante no desempenho de empunhadura em modalidades como lutas e escalada. Este estudo teve por propósito avaliar a aptidão de força isotônica máxima e de preensão manual em praticantes e não praticantes de montaria em touros, a fim de obter parâmetros de referência desta população. Foram avaliados 20 sujeitos em dois grupos, sendo 10 classificados como atletas de montaria e 10 não-atletas. A avaliação da força de preensão manual foi realizada em dinamômetro em posição convencional (DP) e específica (DE), com ambas as mãos (D e E). A força isotônica máxima foi determinada pelo teste de uma repetição máxima (1RM) e também foram obtidas medidas de circunferência dos segmentos, bem como a composição corporal por protocolo de dobras cutâneas. Os valores das variáveis foram comparados pelo teste-t (ρ ≤ 0,05) para dados independentes. As relações entre os valores de força e características antropométricas foram traçadas pelo coeficiente de Pearson. Os resultados para AMT em DPD (43.8±6.8 kgf), DPE (39.4±7.7 kgf), DED (44.9±5.6 kgf) e DEE (39.8±8.3 kgf) comparados aos apresentados por n-AMT em DPD (47.0±3.0 kgf), DPE (42.2±6.1 kgf), DED (49.2±1.5 kgf) e DEE (46.2±4.1 kgf) apresentaram diferenças apenas para DED e DEE. A força nos testes de 1RM (supino reto: 73.2±12.0 kg e 82.0±12.0 kg; rosca direta: 45.2±8.9 kg e 43.8±8.9 kg; tríceps pulley: 67.0±6.3 kg e 72.0±6.3 kg; e puxada posterior: 73.5±8.5 kg e 73.7±7.5 kg) não mostram diferenças entre os grupos. A influência sobre a dinamometria apresenta-se diferente entre os grupos, sendo relevante a força de flexão do cotovelo em AMT e a antropometria e força isotônica para n-AMT. Conclui-se que as características morfo-funcionais de membros superiores não demandam especificidade à montaria em touros.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The use of alternative energy systems in the current days is an urgent necessity due to the problems that the planet is facing as the heating and loss of ozone layer. The scarcity of conventional energy is another problem that must be solved for the future of humanity. It must be considered that the people are inhabiting places moved away not always with available energy. The application of technologies as automation and control can help us to solve this problem. Therefore, this work aimed at apply an equipment of industrial usage, the Programmable Logical Controller, PLC, in alternative energies systems, as eolic generation and fotovoltaic generation used for water pumping, aiming the automatic control and the efficiency in the places where it has simultaneous availability of these sources, based in criterion of priority that previously established itself between them. It was made a hydraulic and energetic evaluation of the energy system, eolic and fotovoltaic, used in the automatic control system of pumping, in the place of accomplishment of the experiment, according to previously established physical conditions. The results have shown that the control system using the PLC is practicable and has trustworthiness. The program developed can be adapted for the use with several power plants in a specific application place. The fotovoltaic system of pumping, using a polycrystalline of 70 Watts connected to a pump Shurflo 8000, showed to be efficient with significant flows in almost all the months. The eolic system of pumping, using an eolic generator of 400 Watts assembled in place of experiment, did not demonstrate energetic capacity for use in this specific type of application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the pumping pipelines the located load losses are very important since they have direct influence on hydraulic design of an irrigation system, especially regarding the concentric reducers used in the distribution lines. Hence this work was conducted in the Laboratório de Hidráulica do Centro Federal de Educação Tecnológica de Uberaba. We analyzed 03 concentric reducers PVC 75 x 50 mm, 50 mm and 35 x 35 x 1 "operating at different flow rates. The performance of the tests with the variation of flow in every situation possible to obtain equations to estimate the loss. The equation models presented a high setting, thus enabling the determination of the localized head loss in a situation closer to field reality. For the reduction of 75 x 50 x 35 mm and 50 mm at a flow rate 16.97 m³ h-1 the pressure drop reduction was obtained respectively 0.9263 and 2.7408 mca. To the reduction of 35 x 1 "at a flow rate of 6.02 m³ h-1 was obtained 2.9304 mca pressure drop reduction. The located losses produced by these reductions are relatively high and should be considered with great discretion in hydraulic design of the irrigation system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the quality of spray droplet spectrum on coffee tree, by using different equipments and syrup volumes. The experiment was set up in a coffee farm, Acaiá variety, Campos Gerais city, MG, Brazil. The treatments were three syrup volumes (150, 300 and 600 L/ha). The lower volume was sprayed with the pneumatic sprayer Martignani, Whirlwind B612 Autonom-Trac mode, and the other volume rates using the conventional hydraulic sprayer to coffee tree. It was possible concludes that the spray volume can be reduced in applications on coffee tree using the pneumatic sprayer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering that the Brazilian energy source is based on hydroelectric power plants, every moment that it does not rain enough, we are likely to suffer power outage. Making the rational use of energy not only is wise, but also important for financial issues. The industrial sector is of great importance to Brazilian economic context, because it is one that creates more wealth and jobs. It should be noted that it is one of the sectors that consume more electricity. One of the most used equipment in industry is the three phase induction motor, which ends up providing significant waste of energy. For that reasons, studying three phase induction motors is important. One of the ways to evaluate the parameter of the three phase induction motor is using a dynamometer mechanic or electric. This work aims at further studies (and development) of electrodynamometer brake, a type of electrical dynamometer, that is the only one with reversible use. This means, it is possible to measure both the torque and the power transmitted by the electric motors, by the direct method and the indirect. Besides it allows greater stability in the imposition of charges, due to its nature of being able to regenerate the energy imparted by the engines being tested

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considering that the Brazilian energy source is based on hydroelectric power plants, every moment that it does not rain enough, we are likely to suffer power outage. Making the rational use of energy not only is wise, but also important for financial issues. The industrial sector is of great importance to Brazilian economic context, because it is one that creates more wealth and jobs. It should be noted that it is one of the sectors that consume more electricity. One of the most used equipment in industry is the three phase induction motor, which ends up providing significant waste of energy. For that reasons, studying three phase induction motors is important. One of the ways to evaluate the parameter of the three phase induction motor is using a dynamometer mechanic or electric. This work aims at further studies (and development) of electrodynamometer brake, a type of electrical dynamometer, that is the only one with reversible use. This means, it is possible to measure both the torque and the power transmitted by the electric motors, by the direct method and the indirect. Besides it allows greater stability in the imposition of charges, due to its nature of being able to regenerate the energy imparted by the engines being tested

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The joint torque is an important variable related to children with cerebral palsy. The present study analyzed kinetic parameters during elbow flexion and extension movements in healthy and cerebral palsy children. Ten healthy and 10 cerebral palsy children participated of the study. An isokinetic dynamometer was used to measure the elbow mean peak torque, mean angle peak torque, coefficient of variation and acceleration during flexion and extension movements at different angular speeds. The mean peak torque on extension movement in healthy children group was significant higher compared to the cerebral palsy group. The coefficient of variation on both flexion and extension movements was significantly higher in cerebral palsy group. However there were significantly difference on both groups compared the lowest and highest velocities. Although the results showed no difference in flexor peak torque, the acceleration is significantly lower in lowest and highest angular velocity.