970 resultados para Ct Scans
Resumo:
Background: Malignancies of the biliary and pancreatic systems are associated with a poor prognosis. However, ampullary cancer carries a better prognosis and is often diagnosed when curative treatment is still possible. Accurate staging is important for the determination of the most appropriate treatment option. Objectives: (1) To determine the test performance characteristics of EUS and CT in loco-regional staging of ampullary neoplasms, and (2) to determine the impact of CT scan results on the test performance characteristics of EUS. Design and Setting: Prospective single-arm intervention study performed in 2 academic hospitals. Results and Main Outcome Measurements: Thirty-seven patients were screened and 33 staged with EUS and CT A total of 27 patients (13 men; mean age, 69.5 years; mean serum bilirubin level, 12.6 mg/dL) with locally advanced disease completed the protocol with EUS and CT and underwent surgical resection. Tumor classifications were as follows: 2 patients (7.4%), T1 tumors; 13 patients (48.1%), T2 tumors; and 12 patients (44.4%), T3 tumors, as per surgical pathology. Seventeen tumors (62.9%) were classified as NO and 10 (37.1%) as NI. The difference in proportion of correct tumor (74.1% vs 51.8%; P =.15, 95% CI, -0.06-0-50) and lymph node (81.4% vs; 55.5%; P =.07, 95% Cl, -0.01-0.53) staging by EUS and CT, respectively, was not statistically significantly different. However, the strength of tumor (kappa 0.51 vs 0.11) and nodal (kappa 0.59 vs 0.05) agreement with pathology was statistically significantly higher for EUS than for CT (P <.05). EUS was more sensitive and specific than CT for tumor and nodal staging, and the association of CT to EUS data did not improve the final test accuracy Limitation: Low number of T1 tumors. Conclusions: EUS is in accurate diagnostic test and exhibits a high level of agreement with surgical pathology. CT findings do not improve the test performance characteristics of EUS. Therefore, the evaluation for metastatic disease should not be compromised by CT protocols that aim to perform tumor and nodal staging. Further studies to determine the role of specialized CT protocols in patients with ampullary malignancies are needed. (Gastrointest Endosc 2009;70:290-6.)
Resumo:
Background The development of products and services for health care systems is one of the most important phenomena to have occurred in the field of health care over the last 50 years. It generates significant commercial, medical and social results. Although much has been done to understand how health technologies are adopted and regulated in developed countries, little attention has been paid to the situation in low- and middle-income countries (LMICs). Here we examine the institutional environment in which decisions are made regarding the adoption of expensive medical devices into the Brazilian health care system. Methods We used a case study strategy to address our research question. The empirical work relied on in-depth interviews (N = 16) with representatives of a wide range of actors and stakeholders that participate in the process of diffusion of CT (computerized tomography) scanners in Brazil, including manufacturers, health care organizations, medical specialty societies, health insurance companies, regulatory agencies and the Ministry of Health. Results The adoption of CT scanners is not determined by health policy makers or third-party payers of public and private sectors. Instead, decisions are primarily made by administrators of individual hospitals and clinics, strongly influenced by both physicians and sales representatives of the medical industry who act as change agents. Because this process is not properly regulated by public authorities, health care organizations are free to decide whether, when and how they will adopt a particular technology. Conclusions Our study identifies problems in how health care systems in LMICs adopt new, expensive medical technologies, and suggests that a set of innovative approaches and policy instruments are needed in order to balance the institutional and professional desire to practise a modern and expensive medicine in a context of health inequalities and basic health needs.
Resumo:
OBJECTIVE: We studied the angiographic findings in patients with small epidural hematomas and cranial fractures crossing over the trajectory of the middle meningeal artery and its branches. Additionally, the Occurrence of traumatic vascular lesions and their clinical relevance and treatment are discussed. METHODS: A consecutive analysis was performed for 24 patients who harbored small epidural hematomas in middle meningeal artery topography associated with cranial fractures. Computed tomographic scans and plain x-ray studies were used to diagnose linear cranial fractures. Patients with large epidural hematomas or associated traumatic lesions were excluded from the study. Selective ipsilateral external carotid angiograms were obtained, and an endovascular procedure was performed if any vascular injury was evidenced. RESULTS: In all patients with cranial fractures crossing over the middle meningeal artery and its branches, some kind of vascular lesion was seen. Two types of findings were noted: active extravasation of the contrast medium (71%) and pseudoaneurysms (29%). Early filling of diploic vessels was found in 8.3% of fractures concomitantly with active extravasation. Embolization was performed in all patients. No additional enlargement of the epidural hematoma was observed, and the postoperative period was uneventful. CONCLUSION: This study shows that pseudoaneurysms and active extravasation of contrast are common findings in this subset of patients. Although the natural history of these lesions is still poorly understood, additional investigation with ipsilateral external carotid angiography may be recommended, considering the potentially catastrophic consequences of late rupture.
Resumo:
Objectives: The aim of this study was to determine the precision of the measurements of 2 craniometric anatomic points-glabella and anterior nasal spine-in order to verify their possibility as potential locations for placing implants aimed at nasal prostheses retention. Methods: Twenty-six dry human skulls were scanned in a high-resolution spiral tomography with 1-mm axial slice thickness and 1-mm interval reconstruction using a bone tissue filter. Images obtained were stored and transferred to an independent workstation containing e-film imaging software. The measurements (in the glabella and anterior nasal fossa) were made independently by 2 observers twice for each measurement. Data were submitted to statistical analysis (parametric t test). Results: The results demonstrated no statistically significant difference between interobserver and intraobserver measurements (P > .05). The standard error was found to be between 0.49 mm and 0.84 mrn for measurements in bone protocol, indicating a high /eve/ of precision. Conclusions: The measurements obtained in anterior nasal spine and glabella were considered precise and reproducible. Mean values of such measurements pointed to the possibility of implant placement in these regions, particularly in the anterior nasal spine.
Resumo:
Objectives. The diagnosis of root fractures by conventional radiographs is still difficult because of limitations of 2D images. Cone-beam volumetric tomography improves the diagnosis capacity in dentistry, such as increased radiation dose to the patient and presence of artifacts on the image. Study design. This study compared the images obtained on conventional periapical radiographs and 3D scans (Accuitomo 3DX) for the diagnosis of root fractures. Twenty patients with suspected root fractures were submitted to examination by periapical radiography and CBCT. Two professionals, unaware of the symptomatology, examined these radiographs and CBCT images according to pre-established scores, which were later checked against the signs and symptoms. Results. The results revealed statistical difference for cone-beam volumetric tomography compared with conventional radiographs in the diagnosis of root fractures. Conclusion. It could be concluded that cone-beam volumetric tomography was better than conventional radiography in the diagnosis of root fractures, thereby constituting an excellent alternative for diagnosis in general practice. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2009; 108: 270-277)
Resumo:
The purpose of this study was to evaluate a new periapical index based on cone beam computed tomography (CBCT) for identification of apical periodontitis (AP). The periapical index proposed in this study (CBCTPAI) was developed on the basis of criteria established from measurements corresponding to periapical radiolucency interpreted on CBCT scans. Radiolucent images suggestive of periapical lesions were measured by using the working tools of Planimp software on CBCT scans in 3 dimensions: buccopalatal, mesiodistal, and diagonal. The CBCTPAI was determined by the largest lesion extension. A 6-point (0-5) scoring system was used with 2 additional variables, expansion of cortical bone and destruction of cortical bone. A total of 1014 images (periapical radiographs and CBCT scans) originally taken from 596 patients were evaluated by 3 observers by using the CBCTPAI criteria. AP was identified in 39.5% and 60.9% of cases by radiography and CBCT, respectively (P<.01). The CBCTPAI offers an accurate diagnostic method for use with high-resolution images, which can reduce the incidence of false-negative diagnosis, minimize observer interference, and increase the reliability of epidemiologic studies, especially those referring to AP prevalence and severity. (J Endod 2008;34:1325-1331)
Resumo:
When patients undergo a magnetic resonance imaging scan, they are subject to both strong static and temporal magnetic fields. The temporal fields are designed to vary at each point in the region being imaged. This is achieved by the use of gradient coils. However, when the gradient coils are switched very rapidly, the strongly time-varying magnetic fields produced can be responsible for stimulating nerves in the peripheral regions of the body. This paper gives a somewhat novel explanation for this phenomenon. The physical mechanism suggested is supported by an illustrative theoretical calculation.
Resumo:
Linkage disequilibrium (LD) mapping is commonly used as a fine mapping tool in human genome mapping and has been used with some success for initial disease gene isolation in certain isolated inbred human populations. An understanding of the population history of domestic dog breeds suggests that LID mapping could be routinely utilized in this species for initial genome-wide scans. Such an approach offers significant advantages over traditional linkage analysis. Here, we demonstrate, using canine copper toxicosis in the Bedlington terrier as the model, that LID mapping could be reasonably expected to be a useful strategy in low-resolution, genome-wide scans in pure-bred dogs. Significant LID was demonstrated over distances up to 33.3 cM. It is very unlikely, for a number of reasons discussed, that this result could be extrapolated to the rest of the genome. It is, however, consistent with the expectation given the population structure of canine breeds and, in this breed at least, with the hypothesis that it may be possible to utilize LID in a genome-wide scan. In this study, LD mapping confirmed the location of the copper toxicosis in Bedlington terrier gene (CT-BT) and was able to do so in a population that was refractory to traditional linkage analysis.
Resumo:
One of the current frontiers in the clinical management of Pectus Excavatum (PE) patients is the prediction of the surgical outcome prior to the intervention. This can be done through computerized simulation of the Nuss procedure, which requires an anatomically correct representation of the costal cartilage. To this end, we take advantage of the costal cartilage tubular structure to detect it through multi-scale vesselness filtering. This information is then used in an interactive 2D initialization procedure which uses anatomical maximum intensity projections of 3D vesselness feature images to efficiently initialize the 3D segmentation process. We identify the cartilage tissue centerlines in these projected 2D images using a livewire approach. We finally refine the 3D cartilage surface through region-based sparse field level-sets. We have tested the proposed algorithm in 6 noncontrast CT datasets from PE patients. A good segmentation performance was found against reference manual contouring, with an average Dice coefficient of 0.75±0.04 and an average mean surface distance of 1.69±0.30mm. The proposed method requires roughly 1 minute for the interactive initialization step, which can positively contribute to an extended use of this tool in clinical practice, since current manual delineation of the costal cartilage can take up to an hour.
Resumo:
Os linfomas são tumores estabelecidos a nível do sistema linfático. Devido à sua heterogeneidade classificam-se como Linfoma Hodgkin (LH) e Linfoma não Hodgkin (LNH), apresentando diferente prognóstico e seguimento quimioterapêutico. Actualmente, a Photon Emission Tomography/Computed Tomography (PET/CT, do acrónimo inglês) é considerada “imagem” de excelência no estudo desta patologia. Neste contexto, é objectivo deste artigo verificar a utilidade da técnica PET/CT e correlacionar o valor de Standard Uptake Value (SUV), obtido pela PET, com o estadio histológico do linfoma e com a resposta ao tratamento quimioterapêutico. Metodologia - Analisaram-se retrospectivamente 356 estudos respeitantes a 231 pacientes, aos quais se realizou uma PET/CT para estadiamento, estudo de massa ou avaliação da resposta ao tratamento. Após a administração de uma actividade média de 18F-FDG de 288,6 MBq, foram adquiridas imagens numa PET/CT GE Discovery ST. Os resultados obtidos foram comparados com os dados clínicos dos pacientes. Resultados - Foram encontradas diferenças significativas entre a idade Vs tipo de linfoma. Não foram encontradas diferenças significativas entre: valor de SUVmáx ganglionar, lesões extra-ganglionares e seu valor de SUV relativamente ao tipo de linfoma. Comprovou-se a influência da PET/CT na alteração do estadio do linfoma e atitude terapêutica. Em última análise, obtiveram-se respectivamente os seguintes valores de sensibilidade, especificidade e exactidão: 98%, 79% e 88%. Conclusões - Os resultados obtidos permitem verificar a importância da imagem PET/CT no estadiamento, monitorização e alteração da atitude terapêutica dos LH e LNH.
Resumo:
Introdução – O cancro de pulmão/traqueia e brônquios é a principal causa de morte por neoplasia na União Europeia. A técnica de duas aquisições de imagem em tempos diferentes no Positron Emission Tomography/Computed Tomography (PET/CT) tem sido referenciada em alguns artigos como uma mais-valia no diagnóstico do cancro do pulmão. O objectivo deste estudo consiste em avaliar a eficiência diagnóstica do PET/CT com a aquisição das duas imagens em tempos diferentes na caracterização do nódulo solitário pulmonar (NSP), tendo em conta a histologia e o tamanho do nódulo. Metodologia – Foram analisados 115 NSP, num total de 110 pacientes, dos quais 65 nódulos eram malignos. Adquiriram-se duas imagens, a primeira a um tempo médio de 52 minutos e a segunda a um tempo médio de 125 minutos após administração do 18F-2-fluoro-2-deoxi-D-glucose (18F-FDG). Para a análise das imagens obteve-se o standard uptake value máximo (SUVmax) e a percentagem de variação dos SUVmax (%variação). Resultados – A %variação apresenta valores de eficiência diagnóstica superiores à análise dos SUVmax em separado. Existem também diferenças significativas na histologia e no SUVmax, registando-se um aumento do SUVmax2 comparativamente ao SUVmax1 nas patologias malignas. Conclusão – A técnica da aquisição de duas imagens em tempos diferentes mostrou ser mais eficaz na caracterização do NSP do que a análise de apenas uma imagem.
Resumo:
Mestrado em Medicina Nuclear - Área de especialização: Tomografia por Emissão de Positrões.
The use of non-standard CT conversion ramps for Monte Carlo verification of 6 MV prostate IMRT plans
Resumo:
Monte Carlo (MC) dose calculation algorithms have been widely used to verify the accuracy of intensity-modulated radiotherapy (IMRT) dose distributions computed by conventional algorithms due to the ability to precisely account for the effects of tissue inhomogeneities and multileaf collimator characteristics. Both algorithms present, however, a particular difference in terms of dose calculation and report. Whereas dose from conventional methods is traditionally computed and reported as the water-equivalent dose (Dw), MC dose algorithms calculate and report dose to medium (Dm). In order to compare consistently both methods, the conversion of MC Dm into Dw is therefore necessary. This study aims to assess the effect of applying the conversion of MC-based Dm distributions to Dw for prostate IMRT plans generated for 6 MV photon beams. MC phantoms were created from the patient CT images using three different ramps to convert CT numbers into material and mass density: a conventional four material ramp (CTCREATE) and two simplified CT conversion ramps: (1) air and water with variable densities and (2) air and water with unit density. MC simulations were performed using the BEAMnrc code for the treatment head simulation and the DOSXYZnrc code for the patient dose calculation. The conversion of Dm to Dw by scaling with the stopping power ratios of water to medium was also performed in a post-MC calculation process. The comparison of MC dose distributions calculated in conventional and simplified (water with variable densities) phantoms showed that the effect of material composition on dose-volume histograms (DVH) was less than 1% for soft tissue and about 2.5% near and inside bone structures. The effect of material density on DVH was less than 1% for all tissues through the comparison of MC distributions performed in the two simplified phantoms considering water. Additionally, MC dose distributions were compared with the predictions from an Eclipse treatment planning system (TPS), which employed a pencil beam convolution (PBC) algorithm with Modified Batho Power Law heterogeneity correction. Eclipse PBC and MC calculations (conventional and simplified phantoms) agreed well (<1%) for soft tissues. For femoral heads, differences up to 3% were observed between the DVH for Eclipse PBC and MC calculated in conventional phantoms. The use of the CT conversion ramp of water with variable densities for MC simulations showed no dose discrepancies (0.5%) with the PBC algorithm. Moreover, converting Dm to Dw using mass stopping power ratios resulted in a significant shift (up to 6%) in the DVH for the femoral heads compared to the Eclipse PBC one. Our results show that, for prostate IMRT plans delivered with 6 MV photon beams, no conversion of MC dose from medium to water using stopping power ratio is needed. In contrast, MC dose calculations using water with variable density may be a simple way to solve the problem found using the dose conversion method based on the stopping power ratio.
Resumo:
Introduction: The quantification of th e differential renal function in adults can be difficult due to many factors - on e of the se is the variances in kidney depth and the attenuation related with all the tissue s between the kidney and the camera. Some authors refer that t he lower attenuation i n p ediatric patients makes unnecessary the use of attenuation correction algorithms. This study will com pare the values of differential renal function obtained with and with out attenuation correction techniques . Material and Methods: Images from a group consisting of 15 individuals (aged 3 years +/ - 2) were used and two attenuation correction method s were applied – Tonnesen correction factors and the geometric mean method . The mean time of acquisition (time post 99m Tc - DMSA administration) was 3.5 hours +/ - 0.8h. Results: T he absence of any method of attenuation correction apparently seems to lead to consistent values that seem to correlate well with the ones obtained with the incorporation of methods of attenuation correction . The differences found between the values obtained with and without attenuation correction were not significant. Conclusion: T he decision of not doing any kind of attenuation correction method can apparently be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for a really accurate value of the relative kidney uptake, then an attenuation correction method should be used.
Resumo:
Mestrado em Medicina Nuclear - Ramo de especialização: Tomografia por Emissão de Positrões