362 resultados para Accelerometer
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis
Resumo:
Introduction: The rest interval between bouts is a crucial variable of resistance training to ensure recovery of neuromuscular capacity. Objective: To compare the effect of rest interval between repeated bouts of resistance training on neuromuscular capacity of trained men. Methods: Eight resistance-trained men (21.6 +/- 3.3 years, 75.1 +/- 11.3 kg, 178.2 +/- 6.8 cm) performed two randomized and crossover resistance exercise bouts, repeated with rest interval of 24h or 48h. The bouts consisted of horizontal, inclined and declined bench press performed with five sets of 10 repetitions with an intensity of 70% of one repetition maximum (1RM) for each exercise. Neuromuscular performance post-exercise bout (strength, power and speed), was assessed with an accelerometer (Myotest (R)), with a load of 50% 1RM, in the bench press exercise. Results: Both sessions (24 and 48h) showed significant reduction (P < 0.05) in the neuromuscular capacity (strength, power and speed) post-exercise bout, returning to baseline values within 24h (P> 0.05). Conclusion: The results suggest that the rest interval of 24h is sufficient for recovery of neuromuscular performance in upper limbs of resistance-trained men.
Resumo:
Pós-graduação em Agronomia (Energia na Agricultura) - FCA
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper refers to the design of an expert system that captures a waveform through the use of an accelerometer, processes the signal and converts it to the frequency domain using a Fast Fourier Transformer to then, using artificial intelligence techniques, specifically Fuzzy Reasoning, it determines if there is any failure present in the underlying mode of the equipment, such as imbalance, misalignment or bearing defects.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Ciências da Motricidade - IBRC
Resumo:
In this work we study the construction of a test rig made to simulate the Mechanical efforts in wich a drillstring is submitted. The model is based on the rig built at IDS, Germany. There are some fault liabilities while doing the project of the axis. Therefore it's important to analyze and take knowledge of this efforts in order to predict failures like rupture or fatigue collapse. The main objective of this theis is to show the operating principle of the test rig and it's construction. The accomplished study allow us to predict the drillstring behavior and from the economic point of view that is very important because failures results in equipments maintenance that requires time and money causing prejudice to the company. Using SolidWorks, a simulation software, the thesis approaches all the mechanical parts required for it's construction as well as it's working principle. Acquisition sensors like strain gauges, accelerometer, and torque transductor were also used in this model. The objective of this thesis is to create a simulation model to be eventually at FEG(UNESP). During the development of the study, it was possible to learn more about the drilling process and the mechanical efforts in which the drill pipe is submitted. The accomplished contributed with knowledge for the student in the drilling process area. Also during the development of the study it was possible to have contact with different areas of engineering but the study is specifically directed to the construction of the test rig. Therefore the main theme of this thesis is to show the operating principle of the test rig and it's construction
Resumo:
In this work we study the construction of a test rig made to simulate the Mechanical efforts in wich a drillstring is submitted. The model is based on the rig built at IDS, Germany. There are some fault liabilities while doing the project of the axis. Therefore it's important to analyze and take knowledge of this efforts in order to predict failures like rupture or fatigue collapse. The main objective of this theis is to show the operating principle of the test rig and it's construction. The accomplished study allow us to predict the drillstring behavior and from the economic point of view that is very important because failures results in equipments maintenance that requires time and money causing prejudice to the company. Using SolidWorks, a simulation software, the thesis approaches all the mechanical parts required for it's construction as well as it's working principle. Acquisition sensors like strain gauges, accelerometer, and torque transductor were also used in this model. The objective of this thesis is to create a simulation model to be eventually at FEG(UNESP). During the development of the study, it was possible to learn more about the drilling process and the mechanical efforts in which the drill pipe is submitted. The accomplished contributed with knowledge for the student in the drilling process area. Also during the development of the study it was possible to have contact with different areas of engineering but the study is specifically directed to the construction of the test rig. Therefore the main theme of this thesis is to show the operating principle of the test rig and it's construction
Resumo:
The purpose of this study was to examine the relationship between cardiac autonomic control derived from heart rate variability (HRV), high-sensitivity C-reactive protein (hs-CRP) and physical activity (PA) levels measured using accelerometers. A total of 80 healthy university students volunteered to participate in this study (20.56 +/- 0.82 years, 1.36 +/- 1.5 mg/L of hs-CRP). The participants were divided into groups based on tertiles of hs-CRP. Analysis of covariance adjusted to PA was used to assess group differences in HRV. Associations between hs-CRP, HRV indices and PA were analyzed using Pearson's correlation. The participants at the highest tertile of hs-CRP (tertile 3) had lower cardiac vagal modulation (SDNN, tertile 1=78.05 +/- 5.9,tertile 2=82.43 +/- 5.9,tertile 3=56.03 +/- 6.1; SD1, tertile 1=61.27 +/- 5.3, tertile 2=62.93 +/- 5.4, tertile 3=40.03 +/- 5.5). In addition, vagal indices were inversely correlated with hs-CRP but positively correlated with PA (SDNN r=-0.320, SD1 r=-0.377; SDNN r=0.304, SD1 r=0.299; P<0.05). Furthermore, the most physically active subjects had lower levels of hs-CRP and the highest levels of vagal modulation.
Resumo:
Piezoresistive sensors are commonly made of a piezoresistive membrane attached to a flexible substrate, a plate. They have been widely studied and used in several applications. It has been found that the size, position and geometry of the piezoresistive membrane may affect the performance of the sensors. Based on this remark, in this work, a topology optimization methodology for the design of piezoresistive plate-based sensors, for which both the piezoresistive membrane and the flexible substrate disposition can be optimized, is evaluated. Perfect coupling conditions between the substrate and the membrane based on the `layerwise' theory for laminated plates, and a material model for the piezoresistive membrane based on the solid isotropic material with penalization model, are employed. The design goal is to obtain the configuration of material that maximizes the sensor sensitivity to external loading, as well as the stiffness of the sensor to particular loads, which depend on the case (application) studied. The proposed approach is evaluated by studying two distinct examples: the optimization of an atomic force microscope probe and a pressure sensor. The results suggest that the performance of the sensors can be improved by using the proposed approach.