972 resultados para quality adjustment


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Methods. aEuro integral Thirty mothers of disabled children participated in the study. The control group comprised of 18 healthy mothers of children without disabilities. All mothers agreed to participate in the study. They completed the evaluation forms of the SF-36 health survey, a well-documented, self-administered QOL scoring system. Results. aEuro integral The results of our study support the premise that mothers of children with CP, as a group, have poorer QOL than mothers of not disabled children. Conclusions. aEuro integral We also observed that mothers of children with CP and epilepsy have poorer QOL than mothers of children with CP without epilepsy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Great Barrier Reef Water Quality Protection Plan (the Reef Plan) is a joint initiative of the Australian and Queensland Governments. The Reef Plan aims to progress an integrated approach to natural resource management planning by building on the existing partnerships between the different levels of government, industry groups, the community and research providers within the Reef catchments, principally through partnerships with the regional natural resource management (NRM) bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To verify the consequences of implant-supported fixed oral rehabilitation on the quality of life (QL) of elderly individuals. Material and methods: Fifteen patients were studied, being 10 females and five males; all were aged > 60 years, were completely edentulous, wore removable dentures on both arches, and were treated with implant-supported fixed dentures. Three QL questionnaires were applied, two related to the oral conditions (Oral Impact on Daily Performance - OIDP - and Oral Health Impact Profile, short version - OHIP-14) and one dealing with global aspects (World Health Organization Quality of Life - WHOQOL-BREF), before 3, 6, and 18 months after surgical placement of implants. Results: Scores in the OIDP and OHIP-14 questionnaires were better after dental treatment. The WHOQOL-BREF was less sensitive, confirming the higher reliability of specific questionnaires (focal) compared with general questions in such situations. Conclusion: Treatment with implant-supported fixed prostheses improved QL in the elderly; these effects are better detected by specific instruments focused on the subject.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: In this study, we aimed to evaluate the long-term stability of anterior open-bite treatment with occlusal adjustment and the dentinal sensitivity caused by this procedure in the long term. Methods: The sample comprised 17 open-bite patients who experienced relapse of the negative vertical overbite after orthodontic treatment and were retreated with occlusal adjustment. The cephalometric changes were evaluated on lateral cephalograms obtained before and after the occlusal adjustment and in the long term (mean, 3.4 years after occlusal adjustment). Dentinal sensitivity was also evaluated before the occlusal adjustment, and 1.35 months, 4.61 months, and 3.4 years later. The cephalometric statuses between the 3 evaluations were compared with analysis of variance (ANOVA) and Tukey tests. The percentages of clinically significant relapse were calculated. To compare dentinal sensitivity at the several stages, nonparametric Friedman and Wilcoxon tests were performed. Results: Statistically significant relapse of anterior open bite occurred in 33.3% of the patients. Those who had the procedure before 21 years of age were most likely to experience relapse. Dentinal sensitivity remained within the normal range in the long term. Conclusions: Despite the statistically significant relapse of anterior open bite, clinically significant stability was found in 66.7% of the patients. (Am J Orthod Dentofacial Orthop 2010; 138:14.e1-14.e7)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The purpose of this study was to evaluate the cephalometric and occlusal changes, the functional occlusion, and the dentinal sensitivity of anterior open-bite treatment with occlusal adjustment. Methods: The sample comprised 20 patients who experienced relapse of the anterior open bite (mean, -1.06 mm). Occlusal adjustment was performed until a positive overbite was established. Cephalometric changes were evaluated on lateral cephalograms taken before and after the occlusal adjustment. The functional occlusion analysis consisted of evaluating immediate anterior and canine guidance and the number of teeth in contact before and after the procedure. Dentinal sensitivity was evaluated before, shortly after, and 4.61 months after the occlusal adjustment. Pretreatment and posttreatment cephalometric changes and the number of teeth in contact were compared with dependent t tests. Percentages of anterior and canine guidance before and after the adjustment procedure were compared with the McNemar test. To compare dentinal sensitivity at several stages, the nonparametric Friedman test was used, followed by the Wilcoxon test. Results: Significant increases in overbite and mandibular protrusion were seen, as were significant decreases in apical base discrepancy, facial convexity, and growth pattern angles. The percentages of immediate anterior and canine guidance increased significantly, as did the number of teeth with occlusal contacts. Dentinal sensitivity increased immediately after the adjustment but decreased to normal levels after 4.61 months. Conclusions: Occlusal adjustment is a viable treatment alternative for some open-bite patients; it establishes positive vertical overbite and improves the functional occlusion with only transient dentinal sensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Recently developed portable dental X-ray units increase the mobility of the forensic odontologists and allow more efficient X-ray work in a disaster field, especially when used in combination with digital sensors. This type of machines might also have potential for application in remote areas, military and humanitarian missions, dental care of patients with mobility limitation, as well as imaging in operating rooms. Objective: To evaluate radiographic image quality acquired by three portable X-ray devices in combination with four image receptors and to evaluate their medical physics parameters. Materials and methods: Images of five samples consisting of four teeth and one formalin-fixed mandible were acquired by one conventional wall-mounted X-ray unit, MinRay (R) 60/70 kVp, used as a clinical standard, and three portable dental X-ray devices: AnyRay (R) 60 kVp, Nomad (R) 60 kVp and Rextar (R) 70 kVp, in combination with a phosphor image plate (PSP), a CCD, or a CMOS sensor. Three observers evaluated images for standard image quality besides forensic diagnostic quality on a 4-point rating scale. Furthermore, all machines underwent tests for occupational as well as patient dosimetry. Results: Statistical analysis showed good quality imaging for all system, with the combination of Nomad (R) and PSP yielding the best score. A significant difference in image quality between the combination of the four X-ray devices and four sensors was established (p < 0.05). For patient safety, the exposure rate was determined and exit dose rates for MinRay (R) at 60 kVp, MinRay (R) at 70 kVp, AnyRay (R), Nomad (R) and Rextar (R) were 3.4 mGy/s, 4.5 mGy/s, 13.5 mGy/s, 3.8 mGy/s and 2.6 mGy/s respectively. The kVp of the AnyRay (R) system was the most stable, with a ripple of 3.7%. Short-term variations in the tube output of all the devices were less than 10%. AnyRay (R) presented higher estimated effective dose than other machines. Occupational dosimetry showed doses at the operator`s hand being lowest with protective shielding (Nomad (R): 0.1 mu Gy). It was also low while using remote control (distance > 1 m: Rextar (R) < 0.2 mu Gy, MinRay (R) < 0.1 mu Gy). Conclusions: The present study demonstrated the feasibility of three portable X-ray systems to be used for specific indications, based on acceptable image quality and sufficient accuracy of the machines and following the standard guidelines for radiation hygiene. (C) 2010 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to analyze if the presence of impacted third molars, and their positions in the mandibular angle, can change the bone quality in this area, considering the measure of the cortical thickness in this region as representative or not for mandible fracture risk. Software was used to analyze 50 digital images from panoramic radiographs of patients who had one or two impacted third molars in the mandible, and 30 digital images of patients with agenesis of the mandibular third molar. The thickness of the cortical region of the mandible was measured; it was possible to draw a parallel line to the posterior portion of the mandible and a parallel line to the body of this bone on each side of the image. At the intersection of these lines near the distal portion of the second molar, another line was set up to serve as reference in the cortical thickness measurement. It could be concluded that the cortical thickness of the mandibular angle in male patients without impacted third molars was greater than the thickness in patients with these teeth, and no difference in thickness was found for the female group.