774 resultados para noncontact corneal esthesiometry


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: We have investigated the effect of melatonin and its analogues on rabbit corneal epithelial wound healing. Methods: New Zealand rabbits were anaesthetised and wounds were made by placing Whatman paper discs soaked in n-heptanol on the cornea. Melatonin and analogues (all 10 nmol) were instilled. Wound diameter was measured every 2 hours by means of fluorescein application with a Topcon SL-8Z slit lamp. Melatonin antagonists (all 10 nmol) were applied 2 hours before the application of the n-heptanol-soaked disc and then every 6 hours together with melatonin. To confirm the presence of MT2 receptors in corneal epithelial cells immunohistochemistry, Western blot and RT-PCR assays in native tissue and in rabbit corneal epithelial cells were performed. The tear components were extracted then processed by HPLC to quantify melatonin in tears. Results: Migration assays revealed that melatonin and particularly the treatment with the MT2 agonist IIK7, accelerated the rate of healing (p < 0.001). The application of the non-selective melatonin receptor antagonist luzindole and the MT2 antagonist DH97 (but not prazosin), prevented the effect of melatonin on wound healing (both p < 0.001). Immunohistochemistry, Western blot and RT-PCR assays showed the presence of MT2 melatonin receptor in corneal epithelial cells. In addition, we have identified melatonin in tears and determined its daily variations. Conclusions: These data suggest that MT2 receptors are implicated in the effect of melatonin on corneal wound healing regulating migration rate. This suggests the potential use of melatonin and its analogues to enhance epithelial wound healing in ocular surface disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To investigate the role of ERK1/2 and RhoA/ROCK intracellular pathways in the modification of corneal re-epithelialization when stimulated by the diadenosine polyphosphates Ap4A and Ap3A. Methods. In wounded confluent SIRC (Statens Seruminstitut rabbit cornea) cell monolayers and in the presence or absence of Ap4A or Ap3A 100 μM, a battery of P2 receptor antagonists and inhibitors of tyrosin kinases, MAPK, and cytoskeleton pathways (AG1478 100 μM, U0126 100 μM, Y27632 100 nM, and (−)-blebbistatin 10 μM; n = 8 each) were assayed. Also, the activation of ERK1/2 and ROCK-I was examined by Western blot assay after treatment with Ap4A and Ap3A (100 μM), with or without suramin, RB-2, U0126, and Y27632. The intracellular distribution of pERK and ROCK-I was examined in the presence of Ap4A or Ap3A (100 μM) with U0126 and Y27632 (100 nM). Results. In the presence of Ap4A, U0126, Y27632, AG1478, and (−)-blebbistatin, reduced the migration rate compared to the effect of Ap4A alone (P < 0.0001, P < 0.001, P < 0.01, and P < 0.1 versus Ap4A, respectively). In the presence of Ap3A 100 μM, U0126 and Y27632 accelerated the migration rate when compared with the effect of Ap3A alone, whereas AG1478 and (−)-blebbistatin (P < 0.0001 versus Ap3A) slowed the migration rate. Western blot assays demonstrated that both dinucleotides activated the ERK1/2 pathway but only Ap4A activated the ROCK-I pathway. The intracellular distribution of pERK1/2 and ROCK-I reflected cross-talk between these two pathways. Conclusions. The activation of the Ap4A/P2Y2 receptor, accelerates corneal epithelial cell migration during wound healing with the activation of MAPK and cytoskeleton pathways, whereas activation of the Ap3A/P2Y6 receptor signals only the MAPK pathway.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To investigate the influence of diadenosine polyphosphates on the rate of corneal epithelial cell migration. Methods. Primary corneal epithelial cell cultures were obtained from New Zealand White rabbits. Immunocytochemical experiments were performed by fixing the cells with 4% paraformaldehyde (PFA) and incubated with cytokeratin 3 primary antibody, which was subsequently incubated with a secondary IgG mouse labeled with FITC, and the cells were observed under confocal microscopy. Migration studies were performed by taking confluent monolayers that were wounded with a pipette tip and challenged with different di- and mononucleotides with or without P2 antagonist (n = 8 each treatment). For concentration–response analysis, compounds were tested in doses ranging from 10−8 to 10−3 M (n = 8). The stability of the dinucleotides was assayed by HPLC, with an isocratic method (n = 4). Results. Cells under study were verified as corneal epithelial cells via the immunocytochemical analysis. Cell migration experiments showed that Ap4A, UTP, and ATP accelerated the rate of healing (5, 2.75, and 3 hours, respectively; P < 0.05; P < 0.001), whereas Ap3A, Ap5A, and UDP delayed it (6.5, 10, and 2 hours, respectively; P < 0.05). ADP did not modify the rate of migration. Antagonists demonstrated that Ap4A and Ap3A did activate different P2Y receptors mediating corneal wound-healing acceleration and delay. Concerning the possible degradation of the dinucleotides, it was almost impossible to detect any products resulting from their cleavage. Conclusions. Based on the pharmacological profile of all the compounds tested, the two main P2Y receptors that exist in these corneal cells are a P2Y2 receptor accelerating the rate of healing and a P2Y6 receptor that delays this process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To measure the increase in tear secretion evoked by selective stimulation of the different populations of sensory receptors of the cornea and conjunctiva by using moderate and intense mechanical, chemical, and cold stimuli. Methods. Six healthy subjects participated in the study. Tear secretion was measured in both eyes by the Schirmer’s test conducted under control conditions and after stimulation of the center of the cornea and the temporal conjunctiva with a gas esthesiometer. Mechanical stimulation consisted in three pulses of 3 seconds’ duration of warmed air (at 34°C on the eye surface) applied at moderate (170 mL/min) and high (260 mL/min) flow rates. Cold thermal stimulation was made with cooled air that produced a corneal temperature drop of −1°C or −4.5°C. Chemical (acidic) stimulation was performed with a jet of gas containing a mixture of 80% CO2 in air. Results. The basal volume of tear secretion increased significantly (P < 0.05, paired t-test) after stimulation of the cornea with high-flow mechanical stimuli (260 mL/min), intense cooling pulses (−4.5°C), and chemical stimulation (80% CO2). The same stimuli were ineffective when applied to the conjunctiva. Moderate mechanical (170 mL/min) and cold (−1°C) stimulation of the cornea or the conjunctiva did not change significantly the volume of tear secretion. Conclusions. Reflex tear secretion caused by corneal stimulation seems to be chiefly due to activation of corneal polymodal nociceptors, whereas selective excitation of corneal mechanonociceptors or cold receptors appears to be less effective in evoking an augmented lacrimal secretion. Conjunctival receptors stimulated at equivalent levels do not evoke an increased tear secretion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antecedentes: El Queratocono es un problema oftalmológico que se presenta en la edad adulta temprana, es generalmente bilateral y afecta indistintamente a ambos sexos. Representa la primera causa de trasplante corneal en países desarrollados. En el Ecuador existe escasa evidencia acerca de esta patología. Objetivo general: Establecer el diagnóstico y características del queratocono en pacientes con astigmatismo mayor a 1 dioptría (D) mediante topografía corneal en la consulta externa de oftalmología en el Hospital Santa Inés de Cuenca. Metodología: Se realizó un estudio retrospectivo, observacional y descriptivo. Se estudió las topografías corneales de pacientes con astigmatismo mayor a 1 Dioptría que asistieron a consulta externa de oftalmología en el Hospital Santa Inés de Cuenca entre enero del 2012 a diciembre del 2014. Los datos fueron recolectados del Topógrafo “Atlas 9000” y mediante el programa SPSS Statistics versión 20 se realizó el análisis de los datos. Para el diagnóstico se utilizaron los criterios de Rabinowitz y McDonnell modificados, y para su clasificación, se utilizaron los criterios queratométricos. Resultados: La frecuencia de queratocono fue 28,6%, el 53.1% fueron hombres y el 46.9% mujeres, fue bilateral en el 56.3% de los casos. El grupo de edad más afectado fue el de 20 a 39 años. El 75% de pacientes con queratocono presentó astigmatismo severo y el grado de queratocono incipiente fue el predominante con el 46,9%. Conclusiones: La alta frecuencia de queratocono, demuestra que nos encon-tramos frente a un grave problema de salud que muchas veces pasamos por alto y que compromete seriamente a la población joven

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tesis (Optometra). -- Universidad de La Salle, Facultad de Ciencias de La Salud. Programa de Optometria, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the relationship between short-term and long-term changes in power at different corneal locations relative to the change in central corneal power and the 2-year change in axial elongation relative to baseline in children fitted with orthokeratology contact lenses (OK). METHODS: Thirty-one white European subjects 6 to 12 years of age and with myopia −0.75 to −4.00 DS and astigmatism ≤1.00 DC were fitted with OK. Differences in refractive power 3 and 24 months post-OK in comparison with baseline and relative to the change in central corneal power were determined from corneal topography data in eight different corneal regions (i.e., N[nasal]1, N2, T[temporal]1, T2, I[inferior]1, I2, S[superior]1, S2), and correlated with OK-induced axial length changes at two years relative to baseline. RESULTS: After 2 years of OK lens wear, axial length increased by 0.48±0.18 mm (P0.05). CONCLUSION: The reduction in central corneal power and relative increase in paracentral and pericentral power induced by OK over 2 years were not significantly correlated with concurrent changes in axial length of white European children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A review of the current data on the cell density of normal adult human endothelial cells was carried out in order to establish some common parameters appearing in the different considered populations. From the analysis of cell growth patterns, it is inferred that the cell aging rate is similar for each of the different considered populations. Also, the morphology, the cell distribution and the tendency to hexagonallity are studied. The results are consistent with the hypothesis that this phenomenon is analogous with cell behavior in other structures such as dry foams and grains in polycrystalline materials. Therefore, its driving force may be controlled by the surface tension and the mobility of the boundaries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antecedentes La ectasia corneal post-lasik (ECPL) es una complicación infrecuente, pero devastadora en la cirugía lasik (queratomileusis asistida con éxcimer láser) para el tratamiento de la miopía con o sin astigmatismo. Con base en la tomografía corneal por elevación por imágenes de Scheimpflug (Sistema Pentacam HR, Oculus Wetzlar, Alemania), se propone un novedoso índice acumulativo de riesgo para ser utilizado como prueba diagnóstica de tamizaje y así prevenir esta complicación. Metodología Se realizó un estudio observacional analítico, de corte transversal tipo pruebas diagnósticas, con el fin de evaluar las características operativas del índice NICE teniendo como estándar de referencia el módulo de Belin-Ambrosio (Pentacam HR) utilizando un modelo de regresión logística binaria, tablas de contingencia y estimando el área bajo la curva ROC. Resultados Se evaluaron 361 ojos de los cuales el 59,3% provenían de pacientes de sexo femenino, la edad media global fue de 30 años (RIC 11,0). El modelo logístico binario aplicado se construyó con base en cuatro variables independientes cuantitativas (K2, PAQUI, EP e I-S) y una cualitativa (SEXO), y se determinó su relación con la variable dependiente, NICE (puntaje final). Las variables predictoras fueron estadísticamente significativas clasificando adecuadamente el 92,9% de los ojos evaluados según presencia o ausencia de riesgo. El coeficiente de Nagelkerke fue de 74,4%. Conclusiones El índice acumulativo de riesgo NICE es una herramienta diagnóstica novedosa en la evaluación de candidatos a cirugía refractiva lasik para prevenir la ectasia secundaria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To determine the main causes of penetrating keratoplasty indications at Hospital das Clínicas-UNICAMP (January, 1999 to December, 2003). METHODS: A non-comparative, retrospective series of case studies. The authors reviewed the files of 857 patients who underwent penetrating keratoplasty at Hospital das Clínicas-UNICAMP between 1999-2003 and classified them into different categories according to diagnostic indication for surgery. RESULTS: The age range was between 0-88 years (average 44 years ±1.2). The main causes of penetrating keratoplasty were: keratoconus in 427 cases (49.82%); 152 cases (17.74%) of corneal ulceration (perforated or not); corneal graft failure in 87 cases (10.15%); bullous keratopathy, 72 cases (8.40%); Fuchs dystrophy in 59 cases (6.88%); trachoma complications in 28 cases (3.27%); other causes, 32 (3.74%). In children under 10 years of age, the main cause of penetrating keratoplasty indications was infectious ulcer (77.78%) and between 11-50 years of age, keratoconus was the main cause (71.65%). CONCLUSION: This study was composed of a young population, and the main causes of penetrating keratoplasty were keratoconus and therapeutic keratoplasty.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSES: 1) To verify the impact of the creation of the Single Technical Record (STR) at the University of Campinas (Unicamp) Hospital das Clínicas, on the preservation period of corneas which were used in elective penetrating keratoplasties, and 2) to compare the primary failure incidence in cornea penetrating keratoplasties regarding the periods before and after the creation of STR. METHODS: A retrospective study was conducted at the Unicamp Hospital, which evaluated 15 consecutive cornea penetrating keratoplasties between January 1st and April 30th, 2000 and 24 consecutive penetrating keratoplasties between May 1st and September 20th of the same year (corneas under the control of the STR), totaling 39 keratoplasties. RESULTS: The mean time between cornea preparation and transplantation was 3.8 days (±1.78) in the period before STR creation, and 6.0 days (±2.97) after STR creation, representing a 36.7% increase in the preservation time. There was a statistically significant difference (p=0.02) between the two groups. No corneal primary failure was observed among the 39 transplanted patients in both groups. CONCLUSION: Based on the results of this study, it can be concluded that this new concept of the State Transplantation System has caused a statistically significant increase in the conservation period of corneas, which may reduce the period of a clear transplant due to an increased loss of endothelial cells, as well as increase the primary failure incidence or result in a high number of corneas that cannot be used due to having exceeded the preservation time recommended by the literature.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate the ocular surface toxicity of two nitric oxide donors in ex vivo and in vivo animal models: S-nitrosoglutathione (GSNO) and S-nitroso-N-acetylcysteine (SNAC) in a hydroxypropyl methylcellulose (HPMC) matrix at final concentrations 1.0 and 10.0 mM. METHODS: Ex vivo GSNO and SNAC toxicities were clinically and histologically analyzed using freshly excised pig eyeballs. In vivo experiments were performed with 20 albino rabbits which were randomized into 4 groups (5 animals each): Groups 1 and 2 received instillations of 150 µL of aqueous HPMC solution containing GSNO 1.0 and 10.0 mM, respectively, in one of the eyes; Groups 3 and 4 received instillations of 150 µL of aqueous HPMC solution-containing SNAC 1.0 and 10.0 mM, respectively, in one of the eyes. The contralateral eyes in each group received aqueous HPMC as a control. All animals underwent clinical evaluation on a slit lamp and the eyes were scored according to a modified Draize eye test and were histologically analyzed. RESULTS: Pig eyeballs showed no signs of perforation, erosion, corneal opacity or other gross damage. These findings were confirmed by histological analysis. There was no difference between control and treated rabbit eyes according to the Draize eye test score in all groups (p>0.05). All formulations showed a mean score under 1 and were classified as non-irritating. There was no evidence of tissue toxicity in the histological analysis in all animals. CONCLUSION: Aqueous HPMC solutions containing GSNO and SNAC at concentrations up to 10.0 mM do not induce ocular irritation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a topiramate induced acute bilateral angle-closure glaucoma. This rare adverse effect is an idiosyncratic reaction characterized by uveal effusion and lens forward displacement, leading to increased intraocular pressure and vision loss. We describe a 55 year-old white woman with migraine, spasmodic torticollis and essential tremor, who developed bilateral acute angle-closure glaucoma, one week after starting topiramate 25 mg/day. She was seen at the Ophthalmology Emergency Department of the Fundação João Penido Burnier (Campinas, SP, Brazil) with a 4 hours history of blurry vision, ocular pain and bright flashes vision. Slit lamp examination revealed moderate conjunctival injection and corneal edema, and shallow anterior chambers. Intraocular pressure was 48 mmHg in both eyes. Fundoscopic examination findings were normal. She was treated with timolol, brimonidine, dorzolamide, pilocarpine, prednisone acetate eye drops and acetazolamide. One hour after those measures, as the intraocular pressure was 30 mmHg, she received a manitol intravenous injection and the intraocular pressure normalized. After 24 hours an iridotomy with Yag laser was performed. Topiramate was discontinued and she was totally recovered after one week.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective was to determine the cardiopulmonary effects and eyeball centralization time obtained with 15 or 30µg kg-1 of atracurium in anesthetized dogs under spontaneous breathing. Eighteen healthy adult mixed-breed dogs were used, which received 0.1mg kg-1 acepromazine and 0.5mg kg-1 morphine IM, followed by 4mg kg-1 propofol IV and maintained on isoflurane anesthesia with spontaneous breathing. Animals received 1mL 0.9% NaCl IV (CG), 15µg kg-1 (G15) or 30µg kg-1 (G30) of atracurium IV. Eyeball centralization time was measured; heart rate (HR), systolic (SAP), mean (MAP) and diastolic (DAP) arterial pressures, respiratory rate (RR), tidal volume (Vt) and minute volume (Vm) were determined every 5min, and pH, arterial CO2 pressure (PaCO2 ), arterial O2 pressure (PaO2 ), hemoglobin oxygen saturation (SaO2 ), bicarbonate (HCO3-) and base excess (BE) every 15min until 60min. Both doses of atracurium produced a similar period of eyeball centralization. Vt in groups treated with atracurium was lower than in CG up to 15min. Vm in G15 differed from CG up to 10min and in G30 up to 25min. No differences were observed for cardiovascular parameters, RR, SaO2, PaO2, HCO3- and BE. pH decreased in CG between 30 and 60min and in G15 and G30 at 15min. G30 differed from CG between 15 and 30min. PaCO2 in GC differed from baseline between 30 and 60min and in G15 differed at 15min. Atracurium at the dose of 15µg kg-1 is adequate for short corneal procedures in inhalant-anesthetized dogs under spontaneous breathing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: The ability to predict and understand which biomechanical properties of the cornea are responsible for the stability or progression of keratoconus may be an important clinical and surgical tool for the eye-care professional. We have developed a finite element model of the cornea, that tries to predicts keratoconus-like behavior and its evolution based on material properties of the corneal tissue. METHODS: Corneal material properties were modeled using bibliographic data and corneal topography was based on literature values from a schematic eye model. Commercial software was used to simulate mechanical and surface properties when the cornea was subject to different local parameters, such as elasticity. RESULTS: The simulation has shown that, depending on the corneal initial surface shape, changes in local material properties and also different intraocular pressures values induce a localized protuberance and increase in curvature when compared to the remaining portion of the cornea. CONCLUSIONS: This technique provides a quantitative and accurate approach to the problem of understanding the biomechanical nature of keratoconus. The implemented model has shown that changes in local material properties of the cornea and intraocular pressure are intrinsically related to keratoconus pathology and its shape/curvature.