980 resultados para modified FCI test
Resumo:
On-orbit exposures can come from numerous factors related to the space environment as evidenced by almost 50 years of environmental samples collected for water analysis, air analysis, radiation analysis, and physiologic parameters. For astronauts and spaceflight participants the occupational exposures can be very different from those experienced by workers performing similar tasks in workplaces on Earth, because the duration of the exposure could be continuous for very long orbital, and eventually interplanetary, missions. The establishment of long-term exposure standards is vital to controlling the quality of the spacecraft environment over long periods. NASA often needs to update and revise its prior exposure standards (Spacecrafts Maximum Allowable Concentrations (SMACs)). Traditional standards-setting processes are often lengthy, so a more rapid method to review and establish standards would be a substantial advancement in this area. This project investigates use of the Delphi method for this purpose. ^ In order to achieve the objectives of this study a modified Delphi methodology was tested in three trials executed by doctoral students and a panel of experts in disciplines related to occupational safety and health. During each test/trial modifications were made to the methodology. Prior to submission of the Delphi Questionnaire to the panel of experts a pilot study/trial was conducted using five doctoral students with the goals of testing and adjusting the Delphi questionnaire to improve comprehension, work out any procedural issues and evaluate the effectiveness of the questionnaire in drawing the desired responses. The remainder of the study consisted of two trials of the Modified Delphi process using 6 chemicals that currently have the potential of causing occupational exposures to NASA astronauts or spaceflight participants. To assist in setting Occupational Exposure Limits (OEL), the expert panel was established consisting of experts from academia, government and industry. Evidence was collected and used to create close-ended questionnaires which were submitted to the Delphi panel of experts for the establishment of OEL values for three chemicals from the list of six originally selected (trial 1). Once the first Delphi trial was completed, adjustments were made to the Delphi questionnaires and the process above was repeated with the remaining 3 chemicals (trial 2). ^ Results indicate that experience in occupational safety and health and with OEL methodologies can have a positive effect in minimizing the time experts take in completing this process. Based on the results of the questionnaires and comparison of the results with the SMAC already established by NASA, we conclude that use of the Delphi methodology is appropriate for use in the decision-making process for the selection of OELs.^
Resumo:
The aim of the present study was to examine the effect of sodium bicarbonate ingestion on consecutive "all out" sprint tests, analyzing the acid-base status and its influence on performance and perceived effort. Ten elite bicycle motocross (BMX) riders (20.7 ± 1.4 years, training experience 8-12 years) participated in this study which consisted of two trials. Each trial consisted of three consecutive Wingate tests (WTs) separated by 15 min recovery. Ninety minutes prior to exercise subjects ingested either NaHCO(3) (-) (0.3 g kg(-1) body weight) or placebo. Blood samples were collected for the assessment of blood acid-base status: bicarbonate concentration ([HCO(3) (-)]), pH, base excess (BE) and blood lactate concentration ([La(-)]). Performance variables of peak power (PP), mean power (MP), time to peak power and fatigue index were calculated for each sprint. Significant differences (p < 0.05) were observed in acid-base variables [pH before WT1: 7.47 ± 0.05 vs. 7.41 ± 0.03; [HCO(3) (-)] before WT1: 29.08 ± 2.27 vs. 22.85 ± 0.24 mmol L(-1) (bicarbonate vs. placebo conditions, respectively)], but there were not significant differences in performance variables between trials [PP WT1: 1,610 ± 373 vs. 1,599 ± 370 W; PP WT2: 1,548 ± 460 vs. 1,570 ± 428 W; PP WT3: 1,463 ± 361 vs. 1,519 ± 364 W. MP WT1: 809 ± 113 vs. 812 ± 108 W; MP WT2: 799 ± 135 vs. 799 ± 124 W; MP WT3: 762 ± 165 vs. 782 ± 118 W (bicarbonate vs. placebo conditions, respectively)]. Rating of perceived effort (RPE) was not influenced nor ratings of perceived readiness. Sodium bicarbonate ingestion modified significantly the blood acid-base balance, although the induced alkalosis did not improve the Wingate test performance, RPE and perceived readiness across three consecutive WTs in elite BMX cyclists.
Resumo:
Bitumen modification by polyethylene addition usually improves the mechanical properties of the binder and, therefore, the behavior in service of the bituminous mix: thermal susceptibility and rutting can be diminished, whilst the resistance to low temperature cracking may increase. To achieve this improvement it is necessary a good compatibility between the base bitumen and the polyethylene. Low compatibility between bitumen and polyethylene can lead to phase separation: the polymer- asphalt incompatibility translates into a deterioration of ultimate properties. The object of this research project was to determine if these problems can be diminished by using certain compatibilizer agents, e.g. an aromatic extract from the oil refinery. Compatibility and stability of the polyethylene modified bitumen were studied using conventional test methods and dynamic shear reometer (DSR). Blends of bitumen and polyethylene were prepared with neat bitumen (PMB) or bitumen with compatibilizer as component of the binder (PMBC) and then compared. The experimental results show that “colloid instability index”(IC) is a parameter that can be used to control the compatibility between bitumen and polyethylene. From polyethylene point of view, one of the parameters that govern is the “melt flow index” (MFI). Experimental results show that PMBC formulated with low IC bitumen and hi gh MFI lineal polyethylene can be considered as stable binder.
Resumo:
Due to a growing concern over global warming, the bituminous mixture industry is making a constant effort to diminish its emissions by reducing manufacturing and installation temperatures without compromising the mechanical properties of the bituminous mixtures. The use of mixtures with tyre rubber has demonstrated that these mixtures can be economical and ecological and that they improve the behaviour of the pavements. However, bituminous mixtures with a high rubber content present one major drawback: they require higher mixing and installation temperatures due to the elevated viscosity caused by the high rubber content and thus they produce larger amounts of greenhouse gas emissions than conventional bituminous mixtures. This article presents a study of the effect of four viscosity-reducing additives (Sasobit®, Asphaltan A®, Asphaltan B® and Licomont BS 100®) on a bitumen modified with 15% rubber. The results of this study indicate that these additives successfully reduce viscosity, increase the softening temperature and reduce penetration. However, they do not have a clear effect on the test for elastic recovery and ductility at 25 °C.
Resumo:
The purpose of this study was to test the hypothesis that elevation in protein oxidative damage during the aging process is a targeted rather than a stochastic phenomenon. Oxidative damage to proteins in mitochondrial membranes in the flight muscles of the housefly, manifested as carbonyl modifications, was detected immunochemically with anti-dinitrophenyl antibodies. Adenine nucleotide translocase (ANT) was found to be the only protein in the mitochondrial membranes exhibiting a detectable age-associated increase in carbonyls. The age-related elevation in ANT carbonyl content was correlated with a corresponding loss in its functional activity. Senescent flies that had lost the ability to fly exhibited a relatively higher degree of ANT oxidation and a greater loss of functional activity than their cohorts of the same age that were still able to fly. Exposure of flies to 100% oxygen resulted in an increase in the level of ANT carbonyl content and a loss in its activity. In vitro treatment of mitochondria with a system that generated hydroxyl free radicals caused an increase in ANT carbonyl level and a decrease in ANT exchange activity. ANT was also the only mitochondrial membrane protein exhibiting adducts of the lipid peroxidation product 4-hydroxynonenal. Results of this study indicate that proteins in mitochondrial membranes are modified selectively during aging.
Resumo:
From a set of gonioapparent automotive samples from different manufacturers we selected 28 low-chroma color pairs with relatively small color differences predominantly in lightness. These color pairs were visually assessed with a gray scale at six different viewing angles by a panel of 10 observers. Using the Standardized Residual Sum of Squares (STRESS) index, the results of our visual experiment were tested against predictions made by 12 modern color-difference formulas. From a weighted STRESS index accounting for the uncertainty in visual assessments, the best prediction of our whole experiment was achieved using AUDI2000, CAM02-SCD, CAM02-UCS and OSA-GP-Euclidean color-difference formulas, which were no statistically significant different among them. A two-step optimization of the original AUDI2000 color-difference formula resulted in a modified AUDI2000 formula which performed both, significantly better than the original formula and below the experimental inter-observer variability. Nevertheless the proposal of a new revised AUDI2000 color-difference formula requires additional experimental data.
Resumo:
BACKGROUND As an alternative to the modified Stoppa approach, the Pararectus approach is used clinically for treatment of acetabular fractures involving the anterior column. The current study assessed the surgical exposure and the options for instrumentation using both of these approaches. METHODS Surgical dissections were conducted on five human cadavers (all male, mean age 88 years (82-97)) using the modified Stoppa and the Pararectus approach, with the same skin incision length (10cm). Distal boundaries of the exposed bony surfaces were marked using a chisel. After removal of all soft-tissues, distances from the boundaries in the false and true pelvis were measured with reference to the pelvic brim. The exposed bone was coloured and calibrated digital images of each inner hemipelvis were taken. The amount of exposed surface using both approaches was assessed and represented as a percentage of the total bony surface of each hemipelvis. For instrumentation, a suprapectineal quadrilateral buttress plate was used. Screw lengths were documented, and three-dimensional CT reconstructions were performed to assess screw trajectories qualitatively. Wilcoxon's signed rank test for paired groups was used (level of significance: p<0.05). RESULTS After utilization of the Pararectus approach, the distances from the farthest boundaries of exposed bone towards the pelvic brim were significantly higher in the false but not the true pelvis, compared to the modified Stoppa approach. The percentage (mean±SD) of exposed bone accessible after utilizing the Pararectus approach was 42±8%, compared to 29±6% using the modified Stoppa (p=0.011). In cadavers exposed by the Pararectus approach, screws placed for posterior fixation and as a posterior column screw were longer by factor 1.8 and 2.1, respectively (p<0.05), and screws could be placed more posteromedial towards the posterior inferior iliac spine or in line with the posterior column directed towards the ischial tuberosity. CONCLUSION Compared to the modified Stoppa, the Pararectus approach facilitates a greater surgical access in the false pelvis, provides versatility for fracture fixation in the posterior pelvic ring and allows for the option to extend the approach without a new incision.
Resumo:
National Highway Traffic Safety Administration, Washington, D.C.
Resumo:
Objective: This paper compares four techniques used to assess change in neuropsychological test scores before and after coronary artery bypass graft surgery (CABG), and includes a rationale for the classification of a patient as overall impaired. Methods: A total of 55 patients were tested before and after surgery on the MicroCog neuropsychological test battery. A matched control group underwent the same testing regime to generate test–retest reliabilities and practice effects. Two techniques designed to assess statistical change were used: the Reliable Change Index (RCI), modified for practice, and the Standardised Regression-based (SRB) technique. These were compared against two fixed cutoff techniques (standard deviation and 20% change methods). Results: The incidence of decline across test scores varied markedly depending on which technique was used to describe change. The SRB method identified more patients as declined on most measures. In comparison, the two fixed cutoff techniques displayed relatively reduced sensitivity in the detection of change. Conclusions: Overall change in an individual can be described provided the investigators choose a rational cutoff based on likely spread of scores due to chance. A cutoff value of ≥20% of test scores used provided acceptable probability based on the number of tests commonly encountered. Investigators must also choose a test battery that minimises shared variance among test scores.
Resumo:
Objective: To establish concurrent validity, interrater and test-retest reliability of the Modified Elderly Mobility Scale (MEMS). Methods: Ninety elderly patients were scored on the MEMS. To establish concurrent validity, 75 patients MEMS scores were compared to Functional Independence Measure (FIM) scores using Spearman's correlation. Videotaped patient performances were used to establish interrater and test-retest reliability using percentage absolute agreement and intraclass correlation coefficients (ICCs). Results: The total MEMS score demonstrated a significant association with the motor (r = 0.725) and total FIM scores (r = 0.718). Absolute agreement for interrater reliability was greater than 93% for all test items, with 97 and 98% for the two new measures, respectively. Test-retest reliability demonstrated similar high levels of absolute agreement and had ICCs ranging from 0.870 to 1.0. Conclusions: The MEMS is a quick, valid and reliable test of motor function of elderly patients with a spread of functional levels.
Resumo:
In many models of edge analysis in biological vision, the initial stage is a linear 2nd derivative operation. Such models predict that adding a linear luminance ramp to an edge will have no effect on the edge's appearance, since the ramp has no effect on the 2nd derivative. Our experiments did not support this prediction: adding a negative-going ramp to a positive-going edge (or vice-versa) greatly reduced the perceived blur and contrast of the edge. The effects on a fairly sharp edge were accurately predicted by a nonlinear multi-scale model of edge processing [Georgeson, M. A., May, K. A., Freeman, T. C. A., & Hesse, G. S. (in press). From filters to features: Scale-space analysis of edge and blur coding in human vision. Journal of Vision], in which a half-wave rectifier comes after the 1st derivative filter. But we also found that the ramp affected perceived blur more profoundly when the edge blur was large, and this greater effect was not predicted by the existing model. The model's fit to these data was much improved when the simple half-wave rectifier was replaced by a threshold-like transducer [May, K. A. & Georgeson, M. A. (2007). Blurred edges look faint, and faint edges look sharp: The effect of a gradient threshold in a multi-scale edge coding model. Vision Research, 47, 1705-1720.]. This modified model correctly predicted that the interaction between ramp gradient and edge scale would be much larger for blur perception than for contrast perception. In our model, the ramp narrows an internal representation of the gradient profile, leading to a reduction in perceived blur. This in turn reduces perceived contrast because estimated blur plays a role in the model's estimation of contrast. Interestingly, the model predicts that analogous effects should occur when the width of the window containing the edge is made narrower. This has already been confirmed for blur perception; here, we further support the model by showing a similar effect for contrast perception. © 2007 Elsevier Ltd. All rights reserved.
Resumo:
The object of this work was to further develop the idea introduced by Muaddi et al (1981) which enables some of the disadvantages of earlier destructive adhesion test methods to be overcome. The test is non-destructive in nature but it does need to be calibrated against a destructive method. Adhesion is determined by measuring the effect of plating on internal friction. This is achieved by determining the damping of vibrations of a resonating specimen before and after plating. The level of adhesion was considered by the above authors to influence the degree of damping. In the major portion of the research work the electrodeposited metal was Watt's nickel, which is ductile in nature and is therefore suitable for peel adhesion testing. The base metals chosen were aluminium alloys S1C and HE9 as it is relatively easy to produce varying levels of adhesion between the substrate and electrodeposited coating by choosing the appropriate process sequence. S1C alloy is the commercially pure aluminium and was used to produce good adhesion. HE9 aluminium alloy is a more difficult to plate alloy and was chosen to produce poorer adhesion. The "Modal Testing" method used for studying vibrations was investigated as a possible means of evaluating adhesion but was not successful and so research was concentrated on the "Q" meter. The method based on the use of a "Q" meter involves the principle of exciting vibrations in a sample, interrupting the driving signal and counting the number of oscillations of the freely decaying vibrations between two known preselected amplitudes of oscillations. It was not possible to reconstruct a working instrument using Muaddi's thesis (1982) as it had either a serious error or the information was incomplete. Hence a modified "Q" meter had to be designed and constructed but it was then difficult to resonate non-magnetic materials, such as aluminium, therefore, a comparison before and after plating could not be made. A new "Q" meter was then developed based on an Impulse Technique. A regulated miniature hammer was used to excite the test piece at the fundamental mode instead of an electronic hammer and test pieces were supported at the two predetermined nodal points using nylon threads. This instrument developed was not very successful at detecting changes due to good and poor pretreatments given before plating, however, it was more sensitive to changes at the surface such as room temperature oxidation. Statistical analysis of test results from untreated aluminium alloys show that the instrument is not always consistent, the variation was even bigger when readings were taken on different days. Although aluminium is said to form protective oxides at room temperature there was evidence that the aluminium surface changes continuously due to film formation, growth and breakdown. Nickel plated and zinc alloy immersion coated samples also showed variation in Q with time. In order to prove that the variations in Q were mainly due to surface oxidation, aluminium samples were lacquered and anodised Such treatments enveloped the active surfaces reacting with the environment and the Q variation with time was almost eliminated especially after hard anodising. This instrument detected major differences between different untreated aluminium substrates.Also Q values decreased progressively as coating thicknesses were increased. This instrument was also able to detect changes in Q due to heat-treatment of aluminium alloys.
Resumo:
Common problems encountered in clinical sensing are those of non-biocompatibility, and slow response time of the device. The latter, also applying to chemical sensors, is possibly due to a lack of understanding of polymer support or membrane properties and hence failure to optimise membranes chosen for specific sensor applications. Hydrogels can be described as polymers which swell in water. In addition to this, the presence of water in the polymer matrix offers some control of biocompatibility. They thus provide a medium through which rapid transport of a sensed species to an incorporated reagent could occur. This work considers the feasibility of such a system, leading to the design and construction of an optical sensor test bed. The development of suitable membrane systems and of suitable coating techniques in order to apply them to the fibre optics is described. Initial results obtained from hydrogel coatings implied that the refractive index change in the polymer matrix, due to a change in water content with pH is the major factor contributing to the sensor response. However the presence of the colourimetric reagent was also altering the output signal obtained. An analysis of factors contributing to the overall response, such as colour change and membrane composition were made on both the test bed, via optical response, and on whole membranes via measurement of water content change. The investigation of coatings with low equilibrium water contents, of less than 10% was carried out and in fact a clearer signal response from the test bed was noted. Again these membranes were suprisingly responding via refractive index change, with the reagent playing a primary role in obtaining a sensible or non-random response, although not in a colourimetric fashion. A photographic study of these coatings revealed some clues as to the physical nature of these coatings and hence partially explained this phenomenon. A study of the transport properties of the most successful membrane, on a coated wire electrode and also on the fibre optic test bed, in a series of test environments, indicated that the reagent was possibly acting as an ion exchanger and hence having a major influence on transport and therefore sensor characteristics.
Resumo:
Polymer modified cements and mortars have become popular for use as patch repair materials. General evidence suggests that these materials offer considerable improvements compared to traditional mortars although the mechanisms for this are not fully understood. This work elucidates the factors which govern some properties and performance of different polymer systems. In view of the wide range of commercial systems available, investigations concentrated on the use of three of the most commonly available groups of polymers. These were: (1) Styrene Butadiene Rubber (SBR), (2) Acrylics and, (3) Ethylene Vinyl Acetates (EVA). The later two were in the form of both emulsions and redispersible powders. Experiments concentrated on: (1) Rheological behaviour of polymer modified cement pastes; (2) Workability of polymer modified mortars; (3) Influence of curing conditions on the pore size distribution and diffusion of chloride ions; (4) Bond strength of polymer modified cement and mortar patches; and (5) Microscopic examination and semi-quantitative analyses of the bulk and interfacial microstructures. The following main conclusions were reached: (1) The addition of polymer emulsions have a considerable influence on the workability of fresh cement pastes, the extent of this depending on the type of system used. (2) The rheological parameters of fresh polymer modified mortars can be established using a two-point workability test which may be used when comparing the properties of different systems at constant workability. (3) Curing conditions affect the properties of polymer modified systems and a wet/dry curing regime was essential for good adhesion of these materials to mortar substrates. (4) In contrast, the wet/dry curing regime resulted in a curing affected zone at the surface of patch materials. This can result in a much coarser pore structure and enhanced diffusion of e.g. chloride ions. (5) The microstructure of polymer modified systems was very different compared with the unmodified cement/mortar and varied depending on curing conditions.
Resumo:
An apparatus was developed to project spinning golf balls directly onto golf greens. This employed a modified baseball/practice machine with two counter-rotating pneumatic wheels. The speed of the wheels could be varied independently allowing backspin to be given to the ball. The ball was projected into a darkened enclosure where the motion of the ball before and after impacting with the turf was recorded using a still camera and a stroboscope. The resulting photographs contained successive images of the ball on a single frame of film. The apparatus was tested on eighteen golf courses resulting in 721 photographs of impacts. Statistical analysis was carried out on the results of the photographs and from this, two types of green emerged. On the first, the ball tended to rebound with topspin, while on the second, the ball retained backspin after impact if the initial backspin was greater than about 350 rads-1. Eleven tests were devised to determine the characteristics of greens and statistical techniques were used to analyse the relationships between these tests. These showed the effects of the green characteristics on ball/turf impacts. It was found that the ball retained backspin on greens that were freely drained and had less than 60% of Poa annua (annual meadow grass) in their swards. Visco-elastic models were used to simulate the impact of the ball with the turf. Impacts were simulated by considering the ball to be rigid and the turf to be a two layered system consisting of springs and dampers. The model showed good agreement with experiment and was used to simulate impacts from two different shots onto two contrasting types of green.