910 resultados para intra-modal and inter-modal


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A large number of evidences correlate elevated levels of homocysteine (Hcys) with a higher cardiovascular diseases (CVDs) risk, especially, atherosclerosis. Similarly, abnormal low levels of the vitamins B6, B9 and B12 are associated to an instability in the methionine cycle with an over production of Hcys. Thus, biomedical sciences are looking forward for a cheaper, faster, precise and accurate analytical methodology to quantify these compounds in a suitable format for the clinical environment. Therefore the objective of this study was the development of a simple, inexpensive and appropriate methodology to use at the clinical level. To achieve this goal, a procedure integrating a digitally controlled (eVol®) microextraction by packed sorbent (MEPS) and an ultra performance liquid chromatography (UPLC) coupled to a photodiode array detector (PDA) was developed to identify and quantify Hcys vitamins B6, B9 and B12. Although different conditions were assayed, we were not able to combine Hcys with the vitamins in the same analytical procedure, and so we proceeded to the optimization of two methods differing only in the composition of the gradient of the mobile phase and the injected volume. It was found that MEPS did not bring any benefit to the quantification of the Hcys in the plasma. Therefore, we developed and validate an alternative method that uses the direct injection of treated plasma (reduced and precipitated). This same method was evaluated in terms of selectivity, linearity, limit of detection (LOD), limit of quantification (LOQ), matrix effect and precision (intra-and inter-day) and applied to the determination of Hcys in a group composed by patients presenting augmented CVD risk. Good results in terms of selectivity and linearity (R2> 0.9968) were obtained, being the values of LOD and LOQ 0.007 and 0.21 mol / L, respectively. The intra-day precision (1.23-3.32%), inter-day precision (5.43-6.99%) and the recovery rate (82.5 to 93.1%) of this method were satisfactory. The matrix effect (>120%) was, however, higher than we were waiting for. Using this methodology it was possible to determine the amount of Hcys in real plasma samples from individuals presenting augmented CVD risk. Regarding the methodology developed for vitamins, despite the optimization of the extraction technique and the chromatographic conditions, it was found that the levels usually present in plasma are far below the sensitivity we obtained. Therefore, further optimizations of the methodology developed are needed. As conclusion, part of the objectives of this study was achieved with the development of a quick, simple and cheaper method for the quantification of Hcys.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The pharmacokinetics of enrofloxacin (ENRO), a fluoroquinolone antimicrobial agent, was studied in male broiler chickens (Cobb) after single oral administration of 10 mg of ENRO/kg b.w. A high-performance liquid chromatography-photodiode array detector (DAD) (HPLC-DAD) method was developed and validated and used for quantitation of ENRO and its major metabolite ciprofloxacin in plasma. The HPLC analyses were carried out using a cationic-octadecyl mixed column and 0.05 mol/L phosphate buffer (pH 2.5)/acetonitrile as mobile phase. The sample preparation of plasma consisted of the precipitation of proteins followed by solid phase extraction on cationic-octadecyl mixed cartridges. The method was validated considering linear range, linearity, selectivity, sensitivity, limit of detection (LOD), limit of quantitation (LOQ), intra- and inter-day precisions and accuracy. The LOD and LOQ for both fluoroquinolones were 60 and 200 ng/mL for plasma. The plasma concentration vs. time graph was characteristic of a two-compartment open model. The maximal plasma concentration of 1.5 +/- 0.2 mg/mL was achieved at 9 +/- 2 h. The elimination half-life and the mean residence time of ENRO were 1.5 +/- 0.2 and 15.64 h, respectively. The area under the concentration-time curve was calculated as 35 +/- 4 mg(.)h/mL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To compare visual inspection (VI), radiographic examination (RX) and the laser fluorescence device DIAGNOdent (L), as well as their combinations in vitro regarding treatment decisions for occlusal surfaces. Methods: 72 extracted human permanent teeth (molars and premolars) were used. Treatment decisions were recorded by three calibrated examiners, and the options available were fissure sealant and conservative restoration. For validation of treatment decisions, the teeth were sectioned and examined in a stereomicroscope. Thereafter, dental slices were scanned and the images were edited to facilitate classification of existing carious lesions. Intra and inter-examiner reproducibility for the determination of treatment plans were calculated using Cohen's kappa test (95%-CI). Sensitivity, specificity, positive and negative predictive values, and the area under the ROC curve were also calculated. Results: VI and L provided on average the greatest intra- and inter-examiner reproducibility, respectively. Although the combination of diagnostic methods may decrease both intra- and inter examiners reproducibility, combination of VI, L and RX resulted in the greatest sensitivity, being statistically superior to RX and L. There was more inter-examiner agreement for the option of restorative treatment, while the use of sealants as a treatment option yielded the lowest values. Negative predictive values were numerically inferior to positive predictive values, indicating that the examiners preferred not to restore a carious tooth than to proceed operatively in an intact tooth. The combination of the three methods studied showed the best results in determining treatment plans for occlusal surfaces, when compared to the other types of exams. on the other hand, radiographic examination and laser fluorescence were less efficient when used alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two high-performance liquid chromatographic methods for determination of residual monomer in dental acrylic resins are described. Monomers were detected by their UV absorbance at 230 nm, on a Nucleosil((R)) C-18 (5 mu m particle size, 100 angstrom pore size, 15 x 0.46 cm i.d.) column. The separation was performed using acetonitrile-water (55:45 v/v) containing 0.01% triethylamine (TEA) for methyl methacrylate and butyl methacrylate, and acetonitrile-water (60:40 v/v) containing 0.01% TEA for isobutyl methacrylate and 1,6-hexanediol dimethacrylate as mobile phases, at a flow rate of 0.8 mL/min. Good linear relationships were obtained in the concentration range 5.0-80.0 mu g/mL for methyl methacrylate, 10.0-160.0 mu g/mL for butyl methacrylate, 50.0-500.0 mu g/mL for isobutyl methacrylate and 2.5-180.0 mu g/mL for 1,6-hexanediol dimethacrylate. Adequate assay for intra- and inter-day precision and accuracy was observed during the validation process. An extraction procedure to remove residual monomer from the acrylic resins was also established. Residual monomer was obtained from broken specimens of acrylic disks using methanol as extraction solvent for 2 h in an ice-bath. The developed methods and the extraction procedure were applied to dental acrylic resins, tested with or without post-polymerization treatments, and proved to be accurate and precise for the determination of residual monomer content of the materials evaluated. Copyright (c) 2005 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We investigated the occurrence of antigenic and biochemical variability among Paracoccidioides brasiliensis antigen batches prepared according to the same protocol. Initially (experiment 1), we analyzed two antigen lots of two human isolates (Bt1 and Bt2), cultured in two media (PYG: bactopeptone, yeast extract, glucose; MMM: McVeigh and Morton medium) in SDS-PAGE and in two immunological tests (immunodiffusion-ID and footpad swelling test-FPT). Afterwards (experiment 2), we compared the antigenic profile of three antigen hatches from three human isolates (Bt1, Bt2 and Bt3) by two-dimensional immunoelectrophoresis (2 D-IEP) against a reference system for P. brasiliensis antigens. In experiment 1, there were important intra- and inter-strain antigenic differences between batches of the fungal isolates cultured on both media. The block titration of the antigen batches for the immunological tests revealed correlation between protein concentration and biological activity in ID and no correlation in FPT. In experiment 2, the reference system for P brasiliensis showed 26 antigen peaks. There were important differences between batches prepared from the same isolate and between batches from different isolates. Our data suggested the occurrence of instability in the synthesis of antigenic components by a same P. brasiliensis isolate, under controlled incubation conditions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present work was conducted with the objective to study the effects of mineral nutrition on Eucalyptus grandis and Brachiaria decumbens (#BRADC) growth, when submitted to inter- and intra-specific competition. The treatments consisted of two plants of Eucalypts/pot, two plants of BRADC/pot, and one plant of each species/pot. The plants were nourished with the Hoagland e Arnon (1950) complete solution; with no K, P or N; or only with either N, P or K. Sixty days after growing side by side, no effect of the inter- and intra-specific competition on eucalypts plant high, branch number and leaf dry mass was observed. When mineral nutrition did not limit plant growth (complete solution or solution with no K), intra-specific competition reduced on average, 23% of eucalypts root length, leaf area, and stem and root dry mass, and inter-specific competition reduced, on average, 75% of BRADC dry mass. When mineral nutrition became a limiting factor, no plant competition effect on the parameters studied was detected.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Influence of cutting instruments and The aim of this study was to analyze the hybrid layer in noncarious dentin prepared by different cutting instruments and restored with composite resin. The cavities were randomly prepared in 40 specimens using a high-speed diamond bur (KG Sorensen 1013) and an ultrasonic tip (CVDentus C22). The cavities were restored with composite resin by varying the adhesive system between the Adper™ Single Bond (2 x 1 system, primer+adhesive) and the Prompt L-Pop™ (3 x 1 system, self-etching). The restorations were hemisected longitudinally and analyzed in the SEM (Scanning electron microscopy) in order to evaluate the hybrid layer and resinous tags characteristics, using scores ranging from 1 to 6. The Pearson test revealed a high correlation coefficient and good significance levels for both intra- and inter-raters values (r=0.90). The data were statistically analyzed using the Mann-Whitney test (P≤0.05). A larger proportion of regular hybrid layers with numerous tags were observed in the dentin prepared using the high-speed diamond burs and restored with a 2 × 1 adhesive system. Alternatively, the 3 × 1 adhesive system promoted the generation of a thin hybrid layer with few tags. After preparation using an ultrasonic tip revealed few or no tags after the preparation and 2 × 1 or 3 × 1 adhesive system application. The high-speed diamond burs produced a dentin surface that was more favorable to restorative material adhesion than the ultrasonic tips, regardless of the adhesive system used.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To evaluate the surgical outcomes of patients with complete unilateral cleft lip and palate (CUCLP) operated on by a single surgeon of the cleft reference center of the Lauro Wanderley University Hospital at the Federal University of Paraiba. Methods: Forty-four individuals' dental casts diagnosed with CUCLP, born between 1995 and 2002, mean age of 11 years, were evaluated by three calibrated orthodontic specialists and scored by the Great Ormond Street, London and Oslo (GOSLON) yardstick on two occasions. The scores were compared with those observed in other centers around the world. The Kappa test was applied to evaluate the intra- and inter-examiner agreement. Descriptive statistics was applied for the GOSLON yardsticks core. Results: The mean GOSLON score was 2.75. For the GOSLON yardstick, 43.2 % of the sample presented scores 1 and 2, 31.8 % had score 3, and 25 % were with scores 4 and 5. There was very good intra- and inter-examiner Kappa agreement in the application of the GOSLON yardstick. Conclusions: The data suggest favorable outcomes, with 75 % of cases with no need of orthognathic surgery. The Kappa values confirmed the high reproducibility of the GOSLON yardstick. © 2013 Springer-Verlag Berlin Heidelberg.