839 resultados para amputation, prosthesis, rehabilitation
Resumo:
Timing data is infrequently reported in aphasiological literature and time taken is only a minor factor, where it is considered at all, in existing aphasia assessments. This is not surprising because reaction times are difficult to obtain manually, but it is a pity, because speed data should be indispensable in assessing the severity of language processing disorders and in evaluating the effects of treatment. This paper argues that reporting accuracy data without discussing speed of performance gives an incomplete and potentially misleading picture of any cognitive function. Moreover, in deciding how to treat, when to continue treatment and when to cease therapy, clinicians should have regard to both parameters: Speed and accuracy of performance. Crerar, Ellis and Dean (1996) reported a study in which the written sentence comprehension of 14 long-term agrammatic subjects was assessed and treated using a computer-based microworld. Some statistically significant and durable treatment effects were obtained after a short amount of focused therapy. Only accuracy data were reported in that (already long) paper, and interestingly, although it has been a widely read study, neither referees nor subsequent readers seemed to miss "the other side of the coin": How these participants compared with controls for their speed of processing and what effect treatment had on speed. This paper considers both aspects of the data and presents a tentative way of combining treatment effects on both accuracy and speed of performance in a single indicator. Looking at rehabilitation this way gives us a rather different perspective on which individuals benefited most from the intervention. It also demonstrates that while some subjects are capable of utilising metalinguistic skills to achieve normal accuracy scores even many years post-stroke, there is little prospect of reducing the time taken to within the normal range. Without considering speed of processing, the extent of this residual functional impairment can be overlooked.
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária
Resumo:
Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária
Resumo:
The therapeutic effects of playing music are being recognized increasingly in the field of rehabilitation medicine. People with physical disabilities, however, often do not have the motor dexterity needed to play an instrument. We developed a camera-based human-computer interface called "Music Maker" to provide such people with a means to make music by performing therapeutic exercises. Music Maker uses computer vision techniques to convert the movements of a patient's body part, for example, a finger, hand, or foot, into musical and visual feedback using the open software platform EyesWeb. It can be adjusted to a patient's particular therapeutic needs and provides quantitative tools for monitoring the recovery process and assessing therapeutic outcomes. We tested the potential of Music Maker as a rehabilitation tool with six subjects who responded to or created music in various movement exercises. In these proof-of-concept experiments, Music Maker has performed reliably and shown its promise as a therapeutic device.
Resumo:
Advanced sensory systems address a number of major obstacles towards the provision for cost effective and proactive rehabilitation. Many of these systems employ technologies such as high-speed video or motion capture to generate quantitative measurements. However these solutions are accompanied by some major limitations including extensive set-up and calibration, restriction to indoor use, high cost and time consuming data analysis. Additionally many do not quantify improvement in a rigorous manner for example gait analysis for 5 minutes as opposed to 24 hour ambulatory monitoring. This work addresses these limitations using low cost, wearable wireless inertial measurement as a mobile and minimal infrastructure alternative. In cooperation with healthcare professionals the goal is to design and implement a reconfigurable and intelligent movement capture system. A key component of this work is an extensive benchmark comparison with the 'gold standard' VICON motion capture system.
Resumo:
Introduction: The prevalence of diabetes is rising rapidly. Assessing quality of diabetes care is difficult. Lower Extremity Amputation (LEA) is recognised as a marker of the quality of diabetes care. The focus of this thesis was first to describe the trends in LEA rates in people with and without diabetes in the Republic of Ireland (RoI) in recent years and then, to explore the determinants of LEA in people with diabetes. While clinical and socio-demographic determinants have been well-established, the role of service-related factors has been less well-explored. Methods: Using hospital discharge data, trends in LEA rates in people with and without diabetes were described and compared to other countries. Background work included concordance studies exploring the reliability of hospital discharge data for recording LEA and diabetes and estimation of diabetes prevalence rates in the RoI from a nationally representative study (SLAN 2007). To explore determinants, a systematic review and meta-analysis assessed the effect of contact with a podiatrist on the outcome of LEA in people with diabetes. Finally, a case-control study using hospital discharge data explored determinants of LEA in people with diabetes with a particular focus on the timing of access to secondary healthcare services as a risk factor. Results: There are high levels of agreement between hospital discharge data and medical records for LEA and diabetes. Thus, hospital discharge data was deemed sufficiently reliable for use in this PhD thesis. A decrease in major diabetes-related LEA rates in people with diabetes was observed in the RoI from 2005-2012. In 2012, the relative risk of a person with diabetes undergoing a major LEA was 6.2 times (95% CI 4.8-8.1) that of a person without diabetes. Based on the systematic review and meta-analysis, contact with a podiatrist did not significantly affect the relative risk (RR) of LEA in people with diabetes. Results from the case-control study identified being single, documented CKD and documented hypertension as significant risk factors for LEA in people with diabetes whilst documented retinopathy was protective. Within the seven year time window included in the study, no association was detected between LEA in patients with diabetes and timing of patient access to secondary healthcare for diabetes management. Discussion: Many countries have reported reduced major LEA rates in people with diabetes coinciding with improved organisation of healthcare systems. Reassuringly, these first national estimates in people with diabetes in the RoI from 2005 to 2012 demonstrated reducing trends in major LEA rates. This may be attributable to changes in diabetes care and also, secular trends in smoking, dyslipidaemia and hypertension. Consistent with international practice, LEA trends data in Ireland can be used to monitor quality of care. Quantifying this improvement precisely, though, is problematic without robust denominator data on the prevalence of diabetes. However, a reduction in major diabetes-related LEA rates suggests improved quality of diabetes care. Much controversy exists around the reliability of hospital discharge data in the RoI. This thesis includes the first multi-site study to explore this issue and found hospital discharge data reliable for the reporting of the procedure of LEA and diagnosis of diabetes. This project did not detect protective effects of access to services including podiatry and secondary healthcare for LEA in people with diabetes. A major limitation of the systematic review and meta-analysis was the design and quality of the included studies. The data available in the area of effect of contact with a podiatrist on LEA risk are too sparse to say anything definitive about the efficacy of podiatry on LEA. Limitations of the case-control study include lack of a diabetes register in Ireland, restricted information from secondary healthcare and lack of data available from primary healthcare. Due to these issues, duration of disease could not be accounted for in the study which limits the conclusions that can be drawn from the results. The model of diabetes care in the RoI is currently undergoing a re-configuration with plans to introduce integrated care. In the future, trends in LEA rates should be continuously monitored to evaluate the effectiveness of changes to the healthcare system. Efforts are already underway to improve the availability of routine data from primary healthcare with the recent development of the iPCRN (Irish Primary Care Research Network). Linkage of primary and secondary healthcare records with a unique patient identifier should be the goal for the future.
Resumo:
Gemstone Team CHIP
Resumo:
Diabetes mellitus is becoming increasingly prevalent worldwide. Additionally, there is an increasing number of patients receiving implantable devices such as glucose sensors and orthopedic implants. Thus, it is likely that the number of diabetic patients receiving these devices will also increase. Even though implantable medical devices are considered biocompatible by the Food and Drug Administration, the adverse tissue healing that occurs adjacent to these foreign objects is a leading cause of their failure. This foreign body response leads to fibrosis, encapsulation of the device, and a reduction or cessation of device performance. A second adverse event is microbial infection of implanted devices, which can lead to persistent local and systemic infections and also exacerbates the fibrotic response. Nearly half of all nosocomial infections are associated with the presence of an indwelling medical device. Events associated with both the foreign body response and implant infection can necessitate device removal and may lead to amputation, which is associated with significant morbidity and cost. Diabetes mellitus is generally indicated as a risk factor for the infection of a variety of implants such as prosthetic joints, pacemakers, implantable cardioverter defibrillators, penile implants, and urinary catheters. Implant infection rates in diabetic patients vary depending upon the implant and the microorganism, however, for example, diabetes was found to be a significant variable associated with a nearly 7.2% infection rate for implantable cardioverter defibrillators by the microorganism Candida albicans. While research has elucidated many of the altered mechanisms of diabetic cutaneous wound healing, the internal healing adjacent to indwelling medical devices in a diabetic model has rarely been studied. Understanding this healing process is crucial to facilitating improved device design. The purpose of this article is to summarize the physiologic factors that influence wound healing and infection in diabetic patients, to review research concerning diabetes and biomedical implants and device infection, and to critically analyze which diabetic animal model might be advantageous for assessing internal healing adjacent to implanted devices.
Resumo:
Approximately 45,000 individuals are hospitalized annually for burn treatment. Rehabilitation after hospitalization can offer a significant improvement in functional outcomes. Very little is known nationally about rehabilitation for burns, and practices may vary substantially depending on the region based on observed Medicare post-hospitalization spending amounts. This study was designed to measure variation in rehabilitation utilization by state of hospitalization for patients hospitalized with burn injury. This retrospective cohort study used nationally collected data over a 10-year period (2001 to 2010), from the Healthcare Cost and Utilization Project (HCUP) State Inpatient Databases (SIDs). Patients hospitalized for burn injury (n = 57,968) were identified by ICD-9-CM codes and were examined to see specifically if they were discharged immediately to inpatient rehabilitation after hospitalization (primary endpoint). Both unadjusted and adjusted likelihoods were calculated for each state taking into account the effects of age, insurance status, hospitalization at a burn center, and extent of burn injury by TBSA. The relative risk of discharge to inpatient rehabilitation varied by as much as 6-fold among different states. Higher TBSA, having health insurance, higher age, and burn center hospitalization all increased the likelihood of discharge to inpatient rehabilitation following acute care hospitalization. There was significant variation between states in inpatient rehabilitation utilization after adjusting for variables known to affect each outcome. Future efforts should be focused on identifying the cause of this state-to-state variation, its relationship to patient outcome, and standardizing treatment across the United States.
Resumo:
BACKGROUND: The purpose of this study was to evaluate whether compliance and rehabilitative efforts were predictors of early clinical outcome of total hip resurfacing arthroplasty. METHODS: A cross-sectional survey was utilized to collect information from 147 resurfacing patients, who were operated on by a single surgeon, regarding their level of commitment to rehabilitation following surgery. Patients were followed for a mean of 52 months (range, 24 to 90 months). Clinical outcomes and functional capabilities were assessed utilizing the Harris hip objective rating system, the SF-12 Health Survey, and an eleven-point satisfaction score. A linear regression analysis was used to determine whether there was any correlation between the rehabilitation commitment scores and any of the outcome measures, and a multivariate regression model was used to control for potentially confounding factors. RESULTS: Overall, an increased level of commitment to rehabilitation was positively correlated with each of the following outcome measures: SF-12 Mental Component Score, SF-12 Physical Component Score, Harris Hip score, and satisfaction scores. These correlations remained statistically significant in the multivariate regression model. CONCLUSIONS: Patients who were more committed to their therapy after hip resurfacing returned to higher levels of functionality and were more satisfied following their surgery.
Resumo:
BACKGROUND: Recent studies suggest that there is a learning curve for metal-on-metal hip resurfacing. The purpose of this study was to assess whether implant positioning changed with surgeon experience and whether positioning and component sizing were associated with implant longevity. METHODS: We evaluated the first 361 consecutive hip resurfacings performed by a single surgeon, which had a mean follow-up of 59 months (range, 28 to 87 months). Pre and post-operative radiographs were assessed to determine the inclination of the acetabular component, as well as the sagittal and coronal femoral stem-neck angles. Changes in the precision of component placement were determined by assessing changes in the standard deviation of each measurement using variance ratio and linear regression analysis. Additionally, the cup and stem-shaft angles as well as component sizes were compared between the 31 hips that failed over the follow-up period and the surviving components to assess for any differences that might have been associated with an increased risk for failure. RESULTS: Surgeon experience was correlated with improved precision of the antero-posterior and lateral positioning of the femoral component. However, femoral and acetabular radiographic implant positioning angles were not different between the surviving hips and failures. The failures had smaller mean femoral component diameters as compared to the non-failure group (44 versus 47 millimeters). CONCLUSIONS: These results suggest that there may be differences in implant positioning in early versus late learning curve procedures, but that in the absence of recognized risk factors such as intra-operative notching of the femoral neck and cup inclination in excess of 50 degrees, component positioning does not appear to be associated with failure. Nevertheless, surgeons should exercise caution in operating patients with small femoral necks, especially when they are early in the learning curve.