993 resultados para X-Rays
Resumo:
OBJECTIVE: Propose and debate the treatment management for unusual traumatic pathology, both due to the age of the patient and the bilateral location. CLINICAL CASE: Bilateral calcaneal fracture in a ten year old male, after falling three meters to land on his heels. Examination revealed pain and swelling at that level, with no distal neurovascular alterations. After the clinical study, x-rays were taken, as well as a CAT scan which revealed a complex fracture of both calcanei. After 72 hours and verifying that the soft tissue was in optimal condition, the left calcaneus was immobilized with a closed cast while the right was trans!xed with a Steinmann pin following the Essex-Lopresti technique, achieved under scope to attain an acceptable reduction of the fracture and the congruency of all a"ected joints.
Resumo:
A 49-year-old man suffered a closed oblique fracture of the middle third of his left femur. Closed reduction and internal fixation by intramedullary (IM) nailing were performed. Per-operative fluoroscopic imaging and initial postoperative X-rays were judged normal and the patient followed the usual rehabilitation protocol. At 3-month follow-up the patient still demonstrated poor knee function and pain. A plain X-ray and a CT scan of the left knee revealed a displaced fracture of the medial femoral condyle. Analysis of the postoperative imaging suggests that the fracture occurred during the insertion of the IM nail. The nail possibly hit the Steinmann traction pin in the distal femur causing the medial condyle fracture. The patient was reoperated; open reduction and internal plate and screw fixation were performed with satisfactory clinical progress postoperatively. The description and illustration of this case is intended to make trauma surgeons aware of this rare but serious complication of IM femoral nailing.
Resumo:
Coronary magnetic resonance angiography (MRA) is a powerful noninvasive technique with high soft-tissue contrast for the visualization of the coronary anatomy without X-ray exposure. Due to the small dimensions and tortuous nature of the coronary arteries, a high spatial resolution and sufficient volumetric coverage have to be obtained. However, this necessitates scanning times that are typically much longer than one cardiac cycle. By collecting image data during multiple RR intervals, one can successfully acquire coronary MR angiograms. However, constant cardiac contraction and relaxation, as well as respiratory motion, adversely affect image quality. Therefore, sophisticated motion-compensation strategies are needed. Furthermore, a high contrast between the coronary arteries and the surrounding tissue is mandatory. In the present article, challenges and solutions of coronary imaging are discussed, and results obtained in both healthy and diseased states are reviewed. This includes preliminary data obtained with state-of-the-art techniques such as steady-state free precession (SSFP), whole-heart imaging, intravascular contrast agents, coronary vessel wall imaging, and high-field imaging. Simultaneously, the utility of electron beam computed tomography (EBCT) and multidetector computed tomography (MDCT) for the visualization of the coronary arteries is discussed.
Resumo:
Reconstruction of important parameters such as femoral offset and torsion is inaccurate, when templating is based on plain x-rays. We evaluate intraoperative reproducibility of pre-operative CT-based 3D-templating in a consecutive series of 50 patients undergoing primary cementless THA through an anterior approach. Pre-operative planning was compared to a postoperative CT scan by image fusion. The implant size was correctly predicted in 100% of the stems, 94% of the cups and 88% of the heads (length). The difference between the planned and the postoperative leg length was 0.3 + 2.3 mm. Values for overall offset, femoral anteversion, cup inclination and anteversion were 1.4 mm ± 3.1, 0.6° ± 3.3°, -0.4° ± 5° and 6.9° ± 11.4°, respectively. This planning allows accurate implant size prediction. Stem position and cup inclination are accurately reproducible.
Resumo:
Introduction: Enchondromas are among the most current benign bone tumours. Malignant degeneration is extremely rare (<1%) and generally presents as a low grade chondrosarcoma. For localized grade 1 lesions, the treatment of choice is curettage. Wide excision and reconstruction is generally not necessary, unless locally advanced or more aggressive behaviour is suspected at presentation. Case report: A healthy 72 yo male presented with pain and recurrent knee joint effusion. X-rays show a classical central distal metaphyseal enchondroma of the femur associated with subtle osteolysis of the lateral condyle. MRI confirms the presence of a locally aggressive chondromatous lesion based in a classical enchondroma. Core needle biopsy revealed a grade 1 chondrosarcoma, which was in contrast to the radiological aggressiveness of the lesion. Total body CT-scan did not reveal metastatic disease. A wide resection was planned, as a high-grade lesion and joint contamination was suspected. We performed an extra-articular knee resection and reconstruction with a hinged modular total knee megaprosthesis. The definitive histology was grade 1 chondrosarcoma, the surgical margins were wide. The evolution was favourable and the patient was able to perform all his activities of daily living independently without pain at 6 weeks postop. Knee flexion reached 90°. The oncologic screening at 18 months did not show local or distant recurrence. Conclusion: Joints near a benign tumour that suddenly become symptomatic or present an effusion might indicate a malignant transformation. Wide resection and prosthetic reconstruction remains an effective treatment option even in low grade cartilaginous lesions if (1) the adjacent joint is contaminated, or (2) joint-sparing surgery would result in a severe functional impairment of the limb.
Resumo:
Background and objectives Interleukin 18 (IL-18) is a pleiotropic cytokine involved in rheumatoid arthritis (RA) pathogenesis. This study was carried out to evaluate the effi cacy of IL-18 binding protein (IL-18BP) gene therapy in the rat adjuvant- induced arthritis (AIA) model and to decipher the mechanisms by which IL-18BP delivery lessens bone destruction.Materials and methods Arthritis was induced in female Lewis rat by Mycobacterium butyricum and the mRNA expression of IL-18 and IL-18BP was determined in the joints. In a preventive study, rats were divided into an adenovirus producing IL-18BP-Fc (AdmIL-18BP-Fc) group (n=8) and an adenovirus producing green fl uorescent protein (AdGFP) group (n=7). On day 8 after AIA induction, adenoviruses were injected. Clinical parameters were assessed. At day 18, during maximal arthritis, the rats were euthanized, ankles were collected and x-rays were performed. mRNA and protein were extracted from joints for analysis by quantitative reverse transcriptase-PCR, multiplex, Western blot and zymography.Results The authors observed a decrease in the (IL-18BP/ IL-18) ratio from day 7 to 45. Administration of AdmIL-18BPd-Fc decreased clinical parameters and prevented bone and joint destruction compared to AdGFP administration. IL-18BP delivery reduced the (receptor activator of nuclear factor κB ligand (RANKL)/osteoprotegerin (OPG)) ratio by 70%, the matrix metalloproteinase 9 (MMP9) level by 33% and the tartrate-resistant acid phosphatase (TRAP) level by 44% in the joint homogenates from AdmIL-18BPd-Fc compared to AdGFP treated rats.Conclusions In rat AIA, a decrease in the (IL-18BP/IL-18) ratio was observed. IL-18BP delivery prevented joint and bone destruction by downregulating MMP9, (RANKL/OPG) and TRAP, suggesting a potential benefi t of a similar therapy in RA.Abstract topics Towards novel therapeutic strategies.
Resumo:
BACKGROUND: Tuberculosis (TB) screening in prisons is recommended, but the appropriate methods remain controversial. Studies evaluating screening in remand prisons arc scarce. METHOD: Between 1997 and 2001, voluntary screening based on the tuberculin skin test (TST) was offered to all prisoners on entry into the largest remand prison in Switzerland. Prisoners with positive results underwent chest X-rays. We analysed this information collected in an anonymous database. RESULTS: A total of 4890 prisoners entered the prison and were eligible for screening; 3779 (77.3%) had TST performed on average 9 days after arrival: 46.9% were positive (induration >= 10 mm). Positive TST rates were similar over the 5 years. Women were more likely to have a negative TST (60.4%) than men (47.7%; P < 0.001, Pearson's chi(2) 16.5). Positive TSTs varied according to the prisoner's country of origin (64% for sub-Saharan Africa, 57% for Eastern Europe, 56% for North Africa, 51% for Asia and 34% for North and West Europe). CONCLUSION: The percentage of TST-positive subjects was high, and most did not receive preventive treatment for latent TB. The usefulness of systematic TST for all prisoners on entry is limited, as diagnosis of TB disease usually remains the priority in prisons. Keywords
Resumo:
We present optical spectroscopy of MWC 656 and MWC 148, the proposed optical counterparts of the gamma-ray sources AGL J2241+4454 and HESS J0632+0 57, respectively. The main parameters of the Halpha emission line (EW, FWHM and centroid velocity) in these stars are modulated on the proposed orbital periods of 60.37 and 321 days, respectively. These modulations are likely produced by the resonant interaction of the Be discs with compact stars in eccentric orbits. We also present radial velocity curves of the optical stars folded on the above periods and obtain the first orbital elements of the two gamma-ray sources thus confirming their binary nature. Our orbital solution support eccentricities e~0.4 and 0.83+-0.08 for MWC 656 and MWC 148, respectively. Further, our orbital elements imply that the X-ray outbursts in HESS J0632+057/MWC 148 are delayed ~0.3 orbital phases after periastron passage, similarly to the case of LS I +61 303. In addition, the optical photometric light curve maxima in AGL J2241+4454/MWC 656 occur ~0.25 phases passed periastron, similar to what is seen in LS I +61 303. We also find that the orbital eccentricity is correlated with orbital period for the known gamma-ray binaries. This is explained by the fact that small stellar separations are required for the efficient triggering of VHE radiation. Another correlation between the EW of Halpha and orbital period is also observed, similarly to the case of Be/X-ray binaries. These correlations are useful to provide estimates of the key orbital parameters Porb and e from the Halpha line in future Be gamma-ray binary candidates.
Resumo:
Context.LS 5039 has been observed with several X-ray instruments so far showing quite steady emission in the long term and no signatures of accretion disk. The source also presents X-ray variability at orbital timescales in flux and photon index. The system harbors an O-type main sequence star with moderate mass-loss. At present, the link between the X-rays and the stellar wind is unclear. Aims.We study the X-ray fluxes, spectra, and absorption properties of LS 5039 at apastron and periastron passages during an epoch of enhanced stellar mass-loss, and the long term evolution of the latter in connection with the X-ray fluxes. Methods.New XMM-Newton observations were performed around periastron and apastron passages in September 2005, when the stellar wind activity was apparently higher. April 2005 Chandra observations on LS 5039 were revisited. Moreover, a compilation of H EW data obtained since 1992, from which the stellar mass-loss evolution can be approximately inferred, was carried out. Results.XMM-Newton observations show higher and harder emission around apastron than around periastron. No signatures of thermal emission or a reflection iron line indicating the presence of an accretion disk are found in the spectrum, and the hydrogen column density () is compatible with being the same in both observations and consistent with the interstellar value. 2005 Chandra observations show a hard X-ray spectrum, and possibly high fluxes, although pileup effects preclude conclusive results from being obtained. The H EW shows yearly variations of 10%, and does not seem to be correlated with X-ray fluxes obtained at similar phases, unlike what is expected in the wind accretion scenario. Conclusions.2005 XMM-Newton and Chandra observations are consistent with 2003 RXTE/PCA results, namely moderate flux and spectral variability at different orbital phases. The constancy of the seems to imply that either the X-ray emitter is located at 1012 cm from the compact object, or the density in the system is 3 to 27 times smaller than that predicted by a spherical symmetric wind model. We suggest that the multiwavelength non-thermal emission of LS 5039 is related to the observed extended radio jets and is unlikely to be produced inside the binary system.
Resumo:
The COMPTEL unidentified source GRO J1411-64 was observed by INTEGRAL, and its central part, also by XMM-Newton. The data analysis shows no hint for new detections at hard X-rays. The upper limits in flux herein presented constrain the energy spectrum of whatever was producing GRO J1411-64, imposing, in the framework of earlier COMPTEL observations, the existence of a peak in power output located somewhere between 300-700 keV for the so-called low state. The Circinus Galaxy is the only source detected within the 4$\sigma$ location error of GRO J1411-64, but can be safely excluded as the possible counterpart: the extrapolation of the energy spectrum is well below the one for GRO J1411-64 at MeV energies. 22 significant sources (likelihood $> 10$) were extracted and analyzed from XMM-Newton data. Only one of these sources, XMMU J141255.6-635932, is spectrally compatible with GRO J1411-64 although the fact the soft X-ray observations do not cover the full extent of the COMPTEL source position uncertainty make an association hard to quantify and thus risky. The unique peak of the power output at high energies (hard X-rays and gamma-rays) resembles that found in the SED seen in blazars or microquasars. However, an analysis using a microquasar model consisting on a magnetized conical jet filled with relativistic electrons which radiate through synchrotron and inverse Compton scattering with star, disk, corona and synchrotron photons shows that it is hard to comply with all observational constrains. This and the non-detection at hard X-rays introduce an a-posteriori question mark upon the physical reality of this source, which is discussed in some detail.
Resumo:
BACKGROUND: The frequency of CT procedures has registered a significant increase over the last decade, which led at the international level to an increasing concern on the radiological risk associated with the use of CT especially in paediatrics. This work aimed at investigating the use of computed tomography in Switzerland, following the evolution of CT frequency and dose data over a decade and comparing it to data reported in other countries. METHODS: The frequency and dose data related to CT are obtained by means of a nationwide survey. National frequencies were established by projecting the collected data, using the ratio of the number of CT units belonging to the respondents to the total number of CT units in the country. The effective doses per examination were collected during an auditing campaign. RESULTS: In 2008 about 0.8 Million CT procedures (~ 100 CT examinations / 1000 population) were performed in the country, leading to a collective effective dose of more than 6000 man.Sv (0.8 mSv/caput). In a decade the frequency of CT examinations averaged over the population and the associated average effective dose per caput increased by a factor of 2.2 and 2.9 respectively. CONCLUSIONS: Although the contribution of CT to the total medical X-rays is 6% in terms of the frequency, it represents 68% in terms of the collective effective dose. These results are comparable to those reported in a number of countries in Europe and America with similar health level.
Resumo:
En el presente trabajo se estudia la síntesis de la reacción en el estado sólido entre el Pbs(PO4)a y el PbCla y la influencia de la temperatura sobre dicha reacción. La fase sintetizada, sometiendo la mezcla a diferentes tiempos de calefacción y a diversos intervalos de temperaturas, ha sido estudiada mediante difracción de rayos X.
Resumo:
We perform a structural and optical characterization of InAs1¿xNx epilayers grown by molecular beam epitaxy on InAs substrates x 2.2% . High-resolution x-ray diffraction HRXRD is used to obtain information about the crystal quality and the strain state of the samples and to determine the N content of the films. The composition of two of the samples investigated is also obtained with time-of-flight secondary ion mass spectroscopy ToF-SIMS measurements. The combined analysis of the HRXRD and ToF-SIMS data suggests that the lattice parameter of InAsN might significantly deviate from Vegard"s law. Raman scattering and far-infrared reflectivity measurements have been carried out to investigate the incorporation of N into the InAsN alloy. N-related local vibrational modes are detected in the samples with higher N content. The origin of the observed features is discussed. We study the compositional dependence of the room-temperature band gap energy of the InAsN alloy. For this purpose, photoluminescence and optical absorption measurements are presented. The results are analyzed in terms of the band-anticrossing BAC model. We find that the room-temperature coupling parameter for InAsN within the BAC model is CNM=2.0 0.1 eV.
Resumo:
Epitaxial films of the biferroic YMnO3 (YMO) oxide have been grown on platinum-coated SrTiO3(1 1 1) and Al2O3(0 0 0 1) substrates. The platinum electrodes, (1 1 1) oriented, are templates for the epitaxy of the hexagonal phase of YMO with a (0 0 0 1) out-of-plane orientation, which is of interest as this is the polarization direction of YMO. X-ray diffractometry indicates the presence of two crystal domains, 60° rotated in-plane, in the Pt(1 1 1) layers which subsequently are transferred on the upperlaying YMO. Cross-section analysis by high-resolution transmission electron microscopy (HRTEM) of YMnO3/Pt/SrTiO3(1 1 1) shows high-quality epitaxy and sharp interfaces across the structure in the observed region. We present a detailed study of the epitaxial growth of the hexagonal YMO on the electrodes.