954 resultados para Vertical pull-out failure


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents two diagnostic methods for the online detection of broken bars in induction motors with squirrel-cage type rotors. The wavelet representation of a function is a new technique. Wavelet transform of a function is the improved version of Fourier transform. Fourier transform is a powerful tool for analyzing the components of a stationary signal. But it is failed for analyzing the non-stationary signal whereas wavelet transform allows the components of a non-stationary signal to be analyzed. In this paper, our main goal is to find out the advantages of wavelet transform compared to Fourier transform in rotor failure diagnosis of induction motors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although parrots share with corvids and primates many of the traits believed to be associated with advanced cognitive processing, knowledge of parrot cognition is still limited to a few species, none of which are Neotropical. Here we examine the ability of three Neotropical parrot species (Blue-Fronted Amazons, Hyacinth and Lear`s macaws) to spontaneously solve a novel physical problem: the string-pulling test. The ability to pull up a string to obtain out-of-reach food has been often considered a cognitively complex task, as it requires the use of a sequence of actions never previously assembled, along with the ability to continuously monitor string, food and certain body movements. We presented subjects with pulling tasks where we varied the spatial relationship between the strings, the presence of a reward and the physical contact between the string and reward to determine whether (1) string-pulling is goal-oriented in these parrots, (2) whether the string is recognized as a means to obtain the reward and (3) whether subjects can visually determine the continuity between the string and the reward, selecting only those strings for which no physical gaps between string and reward were present. Our results show that some individuals of all species were able to use the string as a means to reach a specific goal, in this case, the retrieval of the food treat. Also, subjects from both macaw species were able to visually determine the presence of physical continuity between the string and reward, making their choices consistently with the recognition that no gaps should be present between the string and the reward. Our findings highlight the potential of this taxonomic group for the understanding of the underpinnings of cognition in evolutionarily distant groups such as birds and primates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The aim of this prospective clinical study was to investigate the cephalometric changes produced by bonded spurs associated with high-pull chincup therapy in children with Angle Class I malocclusion and anterior open bite. Methods: Thirty patients with an initial mean age of 8.14 years and a mean anterior open bite of -3.93 mm were treated with bonded spurs associated with chincup therapy for 12 months. An untreated control group of 30 subjects with an initial mean age of 8.36 years and a mean anterior open bite of -3.93 mm and the same malocclusion was followed for 12 months for comparison. Student t tests were used for intergroup comparisons. Results: The treated group demonstrated a significantly greater decrease of the gonial angle, and increase in overbite, palatal tipping of the maxillary incisors, and vertical dentoalveolar development of the maxillary and mandibular incisors compared with the control group. Conclusions: The association of bonded spurs with high-pull chincup therapy was efficient for the correction of the open bite in 86.7% of the patients, with a 5.23-mm (SD, +/- 1.69) overbite increase. (Am J Orthod Dentofacial Orthop 2012;142:487-93)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: This study evaluated the performance of different adhesive systems in fiber post placement aiming to clarify the influence of different hydrophobic experimental blend adhesives, and of one commercially available adhesive on the frictional retention during a luting procedure. Material and Methods: One luting agent (70 Wt% BisGMA, 28.5% TEGDMA; 1.5% p-tolyldiethanolamine) to cement fiber posts into root canals was applied with 4 different adhesive combinations: Group 1: The etched roots were rinsed with water for 30 s to remove the phosphoric acid, then rinsed with 99.6% ethanol for 30 s, and blot-dried. A trial adhesive (base to catalyst on a 1: 1 ratio) was used with an experimental luting agent (35% Bis-GMA, 14.37% TEGDMA, 0.5% EDMAB, 0.13% CQ); Group 2: A trial adhesive (base to catalyst on a 1: 2 ratio) was luted as in Group 1; Group 3: One-Step Plus (OSP, Bisco Inc.) following the ethanol bonding technique in combination with the luting agent as in Group 1; Group 4: OSP strictly following the manufacturer's instructions using the luting agent as in Group 1. The groups were challenged with push-out tests. Posted root slices were loaded until post segment extrusion in the apical-coronal direction. Failure modes were analyzed under scanning electron microscopy. Results: Push-out strength was not significantly influenced by the luting agent (p>0.05). No statistically significant differences among the tested groups were found as Group 1 (Exp 1 - ethanol-wet bonding technique)=Group 2 (Exp 2 - ethanol-wet bonding technique)= Group 3 (OSP - ethanol-wet bonding technique)= Group 4 (control, OSP - water-wet bonding technique) (p>0.05). The dominating failure modes in all the groups were cohesive/adhesive failures, which were predominantly observed on the post/luting agent interface. Conclusions: The results of this study support the hypothesis that the proposal to replace water with ethanol to bond fiber posts to the root canal using highly hydrophobic resin is plausible, but this seems to be more the proof of a concept than a clinically applicable procedure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Carneiro SMBS, Sousa-Neto MD, Rached-Junior FA, Miranda CES, Silva SRC, Silva-Sousa YTC. Push-out strength of root fillings with or without thermomechanical compaction. International Endodontic Journal, 45, 821828, 2012. Abstract Aim To evaluate the influence of thermomechanical compaction (Taggers hybrid technique THT) on the push-out strength of several root filling materials to root dentine. Methodology Root canals of eighty roots in human canines were prepared with the ProTaper system and filled with one of the following materials, using either lateral compaction (LC) (n = 40) or THT (n = 40): AH Plus/gutta-percha (GP) (n = 10), Sealer 26/GP (n = 10), Epiphany SE/Resilon (n = 10) and Epiphany SE/GP (n = 10). Three 2-mm-thick dentine slices were obtained from each third of each root. The root filling in the first slice was subjected to a push-out test to evaluate the bond strength of the materials to intraradicular dentine. Data (in MPa) were analysed using anova and post hoc Tukeys test (P < 0.05). Failure mode was determined at x25 magnification. The other two slices were prepared for scanning electron microscopy (SEM) to examine the surface of the filling materials. Results Lateral compaction (1.34 +/- 1.14 MPa) was associated with a significantly higher bond strength (P < 0.05) than the THT (0.97 +/- 0.88 MPa). AH Plus/GP (2.23 +/- 0.83 MPa) and Sealer 26/GP (1.86 +/- 0.50 MPa) had significantly higher bond strengths than the other materials and differed significantly from each other (P < 0.05). There was a significant difference (P < 0.05) between the coronal (1.36 +/- 1.15 MPa), middle (1.14 +/- 1.05 MPa) and apical thirds (0.95 +/- 0.83 MPa). Considering the technique and root filling material interaction, AH Plus/GP-LC was associated with the highest mean values (2.65 +/- 0.66 MPa) (P < 0.05). Sealer 26/GP-LC (2.10 +/- 0.46 MPa), AH Plus/GP-THT (1.81 +/- 0.78 MPa) and Sealer 26/GP-TH (1.63 +/- 0.44 MPa) had intermediate values that were not significantly different from each other (P > 0.05). Epiphany SE was associated with the lowest mean values (3.70 +/- 0.86 MPa) (P < 0.05), regardless of the root filling technique and type of solid material (cone). Adhesive failures predominated in the specimens filled with Epiphany SE, whilst mixed and cohesive failures were more frequent in those filled with AH Plus and Sealer 26, regardless of the root filling technique. SEM analysis revealed that LC produced a dense and well-compacted filling whilst the use of a hybrid thermomechanical technique resulted in the solid material (GP or Resilon) intermingled within sealer to form a nonhomogenous mass. Conclusion Lateral compaction was associated with higher bond strengths of the materials to intraradicular dentine than a hybrid technique using thermomechanical compaction. The greatest push-out strengths were obtained when the canals were filled with LC of AH Plus and GP cones.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this study was to evaluate the push-out bond strength of fiberglass resin reinforced bonded with five ionomer cements. Also, the interface between cement and dentin was inspected by means of SEM. Fifty human canines were chose after rigorous scrutiny process, endodontically treated and divided randomly into five groups (n = 3) according to cement tested: Group I – Ionoseal (VOCO), Group II – Fugi I (GC), Group III – Fugi II Improved (GC), Group IV – Rely X Luting 2 (3M ESPE), Group V – Ketac Cem (3M ESPE). The post-space was prepared to receive a fiberglass post, which was tried before cementation process. No dentin or post surface pretreatment was carried out. After post bonding, all roots were cross-sectioned to acquire 3 thin-slices (1 mm) from three specific regions of tooth (cervical, medium and apical). A Universal test machine was used to carry out the push-out test with cross-head speed set to 0.5mm/mim. All failed specimens were observed under optical microscope to identify the failure mode. Representative specimens from each group was inspected under SEM. The data were analyzed by Kolmogorov-Smirnov and Levene’s tests and by two-way ANOVA, and Tukey’s port hoc test at a significance level of 5%. It was compared the images obtained for determination of types of failures more occurred in different levels. SEM inspection displayed that all cements filled the space between post and dentin, however, some imperfections such bubles and voids were noticed in all groups in some degree of extension. The push-out bond strength showed that cement Ketac Cem presented significant higher results when compared to the Ionoseal (P = 0.02). There were no statistical significant differences among other cements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Introduction Noninvasive ventilation (NIV), as a weaning-facilitating strategy in predominantly chronic obstructive pulmonary disease (COPD) mechanically ventilated patients, is associated with reduced ventilator-associated pneumonia, total duration of mechanical ventilation, length of intensive care unit (ICU) and hospital stay, and mortality. However, this benefit after planned extubation in patients with acute respiratory failure of various etiologies remains to be elucidated. The aim of this study was to determine the efficacy of NIV applied immediately after planned extubation in contrast to oxygen mask (OM) in patients with acute respiratory failure (ARF). Methods A randomized, prospective, controlled, unblinded clinical study in a single center of a 24-bed adult general ICU in a university hospital was carried out in a 12-month period. Included patients met extubation criteria with at least 72 hours of mechanical ventilation due to acute respiratory failure, after following the ICU weaning protocol. Patients were randomized immediately before elective extubation, being randomly allocated to one of the study groups: NIV or OM. We compared both groups regarding gas exchange 15 minutes, 2 hours, and 24 hours after extubation, reintubation rate after 48 hours, duration of mechanical ventilation, ICU length of stay, and hospital mortality. Results Forty patients were randomized to receive NIV (20 patients) or OM (20 patients) after the following extubation criteria were met: pressure support (PSV) of 7 cm H2O, positive end-expiratory pressure (PEEP) of 5 cm H2O, oxygen inspiratory fraction (FiO2) ≤ 40%, arterial oxygen saturation (SaO2) ≥ 90%, and ratio of respiratory rate and tidal volume in liters (f/TV) < 105. Comparing the 20 patients (NIV) with the 18 patients (OM) that finished the study 48 hours after extubation, the rate of reintubation in NIV group was 5% and 39% in OM group (P = 0.016). Relative risk for reintubation was 0.13 (CI = 0.017 to 0.946). Absolute risk reduction for reintubation showed a decrease of 33.9%, and analysis of the number needed to treat was three. No difference was found in the length of ICU stay (P = 0.681). Hospital mortality was zero in NIV group and 22.2% in OM group (P = 0.041). Conclusions In this study population, NIV prevented 48 hours reintubation if applied immediately after elective extubation in patients with more than 3 days of ARF when compared with the OM group. Trial Registration number ISRCTN: 41524441.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this prospective study was to cephalometrically analyze the stability of dentoalveolar and skeletal changes produced by a removable appliance with palatal crib associated to high-pull chincup in individuals with anterior open bite treated for 12 months, and compare them to individuals with similar malocclusion and age, not submitted to orthodontic treatment, also followed for the same period. METHODS: Nineteen children with a mean age of 9.78 years old treated for 12 months with a removable appliance with palatal crib associated with chincup therapy were evaluated after 15 months (post-treatment period) and compared with a control group of 19 subjects with mean age of 9.10 years with the same malocclusion that was followed-up for the same period. Seventy-six lateral cephalograms were evaluated at T1 (after correction) and T2 (follow-up) and cephalometric variables were analyzed by statistical tests. RESULTS: The results did not show significant skeletal, soft tissue or maxillary dentoalveolar changes. Overall, treatment effects on the experimental group were maintained at T2 evaluation with an increase of 0.56 mm in overbite. Overjet and maxillary incisors/molars position (vertical and sagittal) remained essentially unchanged during the study period. Only mandibular incisors showed significant changes (labial inclination and protrusion) compared to control group. CONCLUSIONS: Thus, it can be concluded that the early open bite treatment with a removable appliance and palatal crib associated with high-pull chincup therapy provided stability of 95%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

[EN] On 8-10 April 2007, several episodes of intense sea-breeze fronts were registered at the island of Fuerteventura (Canary Islands). The sea-breeze circulation was primary driven by daytime heating contrasts between land and the Atlantic Ocean during a period of weak trade winds. Numerical simulations of these events were carried out using the 3.1.1 version of the Weather Research and Forecasting (WRF) Model. Two different domains with 6.6-km and 2.2-km horizontal grid spacing and two sets with 27 and 51 vertical sigma levels were defined. The simulation was performed using two-way interactive nesting between the first and the second domain, using different land surface model parameterizations (Thermal diffusion, Noah LSM and RUC) for comparison. Initial conditions were provided by the NCAR Dataset analysis from April 2007, which were improved using surface and upper-air observations. The poster is focused on the 9 April episode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Object of this thesis has been centrifuge modelling of earth reinforced retaining walls with modular blocks facing in order to investigate on the influence of design parameters, such as length and vertical spacing of reinforcement, on the behaviour of the structure. In order to demonstrate, 11 models were tested, each one with different length of reinforcement or spacing. Each model was constructed and then placed in the centrifuge in order to artificially raise gravitational acceleration up to 35 g, reproducing the soil behaviour of a 5 metre high wall. Vertical and horizontal displacements were recorded by means of a special device which enabled tracking of deformations in the structure along its longitudinal cross section, essentially drawing its deformed shape. As expected, results confirmed reinforcement parameters to be the governing factor in the behaviour of earth reinforced structures since increase in length and spacing improved structural stability. However, the influence of the length was found out to be the leading parameter, reducing facial deformations up to five times, and the spacing playing an important role especially in unstable configurations. When failure occurred, failure surface was characterised by the same shape (circular) and depth, regardless of the reinforcement configuration. Furthermore, results confirmed the over-conservatism of codes, since models with reinforcement layers 0.4H long showed almost negligible deformations. Although the experiments performed were consistent and yielded replicable results, further numerical modelling may allow investigation on other issues, such as the influence of the reinforcement stiffness, facing stiffness and varying backfills.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’attività di ricerca della presente tesi di dottorato ha riguardato sistemi tribologici complessi di interesse industriale per i quali sono stati individuati, mediante failure analysis, i meccanismi di usura dominanti. Per ciascuno di essi sono state studiate soluzioni migliorative sulla base di prove tribologiche di laboratorio. Nella realizzazione di maglie per macchine movimentazione terra sono ampiamente utilizzati i tradizionali acciai da bonifica. La possibilità di utilizzare i nuovi microlegati a medio tenore di carbonio, consentirebbe una notevole semplificazione del ciclo produttivo e benefici in termini di costi. Una parte della tesi ha riguardato lo studio del comportamento tribologico di tali acciai. E’ stato anche affrontato lo studio tribologico di motori idraulici, con l’obiettivo di riuscire a migliorarne la resistenza ad usura e quindi la vita utile. Sono state eseguite prove a banco, per valutare i principali meccanismi di usura, e prove di laboratorio atte a riprodurre le reali condizioni di utilizzo, valutando tecniche di modificazione superficiale che fossero in grado di ridurre l’usura dei componenti. Sono state analizzate diverse tipologie di rivestimenti Thermal Spray in termini di modalità di deposizione (AFS-APS) e di leghe metalliche depositate (Ni,Mo,Cu/Al). Si sono infine caratterizzati contatti tribologici nel settore del packaging, dove l’utilizzo di acciai inox austenitici è in alcuni casi obbligatorio. L’acciaio inossidabile AISI 316L è ampiamente utilizzato in applicazioni in cui siano richieste elevate resistenze alla corrosione, tuttavia la bassa resistenza all’usura, ne limitano l’impiego in campo tribologico. In tale ambito, è stata analizzata una problematica tribologica relativa a macchine automatiche per il dosaggio di polveri farmaceutiche. Sono state studiate soluzioni alternative che hanno previsto sia la completa sostituzione dei materiali della coppia tribologica, sia l’individuazione di tecniche di modificazione superficiale innovative quali la cementazione a bassa temperatura anche seguita dalla deposizione di un rivestimento di carbonio amorfo idrogenato a-C:H

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study investigates the feasibility of a new application able to check the heart failure status in a patient through the estimation of the venous distension. In this way it would be possible to follow up patients, avoiding invasive or expensive exams such as cardiac catheterization and echocardiography. Moreover, the devices would also be able to diagnose the decline of the disease, in order to allow a new adaptation to therapy, and vice versa to check the improvement in the patient’s conditions after the CRT device implant. This thesis is essentially divided into three parts: an analytical model was used to obtain an estimation of the error committed for the calculation of the CSA and to understand how the accuracy and sensitivity depend on the different configurations of the electrodes and the catheter position inside the vein; secondly, an in-vitro experiment was carried out in order to verify the practical feasibility for these kinds of measurements, in a very simplified model; in the end, several animal experiments were done to test the in-vivo practicability of the proposed method. The obtained results showed the feasibility of this approach. In fact, the error committed in the estimation of CSA, during the animal experiments, can be considered acceptable (CSAerror_max ≈ -14%). Moreover, it has been demonstrated that the conductance catheter allows assessing, not only the vein CSA, but also the breathing of the animal.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: This study evaluated the initial and the artificially aged push-out bond strength between ceramic and dentin produced by one of five resin cements. METHODS: Two-hundred direct ceramic restorations (IPS Empress CAD) were luted to standardized Class I cavities in extracted human molars using one of four self-adhesive cements (SpeedCEM, RelyX Unicem Aplicap, SmartCem2 and iCEM) or a reference etch-and-rinse resin cement (Syntac/Variolink II) (n=40/cement). Push-out bond strength (PBS) was measured (1) after 24h water storage (non-aged group; n=20/cement) or (2) after artificial ageing with 5000 thermal cycles followed by 6 months humid storage (aged group; n=20/cement). Nonparametrical ANOVA and pairwise Wilcoxon rank-sum tests with Bonferroni-Holm adjustment were applied for statistical analysis. The significance level was set at alpha=0.05. In addition, failure mode and fracture pattern were analyzed by stereomicroscope and scanning electron microscopy. RESULTS: Whereas no statistically significant effect of storage condition was found (p=0.441), there was a significant effect of resin cement (p<0.0001): RelyX Unicem showed significantly higher PBS than the other cements. Syntac/Variolink II showed significantly higher PBS than SmartCEM2 (p<0.001). No significant differences were found between SpeedCEM, SmartCem2, and iCEM. The predominant failure mode was adhesive failure of cements at the dentin interface except for RelyX Unicem which in most cases showed cohesive failure in ceramic. SIGNIFICANCE: The resin cements showed marked differences in push-out bond strength when used for luting ceramic restorations to dentin. Variolink II with the etch-and-rinse adhesive Syntac did not perform better than three of the four self-adhesive resin cements tested.