999 resultados para Variable Spin Lock Experiment
Resumo:
The Ordos Plateau in China is covered with up to 300,000 ha of peashrub (Caragana) which is the dominant natural vegetation and ideal for fodder production. To exploit peashrub fodder, it is crucially important to optimize the culture conditions, especially culture substrate to produce pectinase complex. In this study, a new prescription process was developed. The process, based on a uniform experimental design, first optimizes the solid substrate and second, after incubation, applies two different temperature treatments (30 degrees C for the first 30 h and 23 degrees C for the second 42 h) in the fermentation process. A multivariate regression analysis is applied to a number of independent variables (water, wheat bran, rice dextrose, ammonium sulfate, and Tween 80) to develop a predictive model of pectinase activity. A second-degree polynomial model is developed which accounts for an excellent proportion of the explained variation (R-2 = 97.7%). Using unconstrained mathematical programming, an optimized substrate prescription for pectinase production is subsequently developed. The mathematical analysis revealed that the optimal formula for pectinase production from Aspergillus niger by solid fermentation under the conditions of natural aeration, natural substrate pH (about 6.5), and environmental humidity of 60% is rice dextrose 8%, wheat bran 24%, ammonium sulfate ((NH4)(2)SO4) 6%, and water 61%. Tween 80 was found to have a negative effect on the production of pectinase in solid substrate. With this substrate prescription, pectinase produced by solid fermentation of A. niger reached 36.3IU/(gDM). Goats fed on the pectinase complex obtain an incremental increase of 0.47 kg day(-1) during the initial 25 days of feeding, which is a very promising new feeding prospect for the local peashrub. It is concluded that the new formula may be very useful for the sustainable development of and and semiarid pastures such as those of the Ordos Plateau. (c) 2005 Elsevier Inc. All rights reserved.
Resumo:
Odorant-induced currents in mammalian olfactory receptor neurons have proved difficult to obtain reliably using conventional whole-cell recording. By using a mathematical model of the electrical circuit of the patch and rest-of-cell, we demonstrate how cell-attached patch measurements can be used to quantitatively analyze responses to odorants or a high (100 mM) K+ solution. High K+ induced an immediate current flux from cell to pipette, which was modeled as a depolarization of similar to 52 mV, close to that expected from the Nernst equation (56 mV), and no change in the patch conductance. By contrast, a cocktail of cAMP-stimulating odorants induced a current flux from pipette into cell following a significant (4-10 s) delay. This was modeled as an average patch conductance increase of 36 pS and a depolarization of 13 mV, Odorant-induced single channels had a conductance of 16 pS. In cells bathed with no Mg2+ and 0.25 mM Ca2+, odorants induced a current flow from cell to pipette, which was modeled as a patch conductance increase of similar to 115 pS and depolarization of similar to 32 mV, All these results are consistent with cAMP-gated cation channels dominating the odorant response, This approach, which provides useful estimates of odorant-induced voltage and conductance changes, is applicable to similar measurements in any small cells.
Resumo:
P>Background: Many patients with common variable immunodeficiency (CVID) have a clinical history suggestive of allergic respiratory disease. However, in such individuals, the prevalence of asthma and the role of atopy have not been well established. The objective of this study was to evaluate pulmonary function and identify asthma in patients with CVID. We also investigated the role of IgE as a trigger of asthma in these patients. Methods: Sixty-two patients diagnosed with CVID underwent spirometry, as well as skin prick testing and in vitro determination of serum-specific IgE levels for aeroallergens, together with bronchial provocation with histamine and allergen. Results: The most common alteration identified through spirometry was obstructive lung disease, which was observed in 29 (47.5%) of the 62 patients evaluated. Eighteen (29.0%) of the 62 patients had a clinical history suggestive of allergic asthma. By the end of the study, asthma had been diagnosed in nine (14.5%) patients and atopy had been identified in six (9.7%). In addition, allergic asthma had been diagnosed in four patients (6.5% of the sample as a whole; 22.2% of the 18 patients with a clinical history suggestive of the diagnosis). Conclusion: In this study, CVID patients testing negative for specific IgE antibodies and suspected of having allergic asthma presented a positive response to bronchial provocation tests with allergens. To our knowledge, this is the first such study. When CVID patients with a history suggestive of allergic asthma test negative on traditional tests, additional tests designed to identify allergic asthma might be conducted.
Resumo:
H-1 NMR spectra of the thyroid hormone thyroxine recorded at low temperature and high field show splitting into two peaks of the resonance due to the H2,6 protons of the inner (tyrosyl) ring. A single resonance is observed in 600 MHz spectra at temperatures above 185 K. An analysis of the line shape as a function of temperature shows that the coalescence phenomenon is due to an exchange process with a barrier of 37 kJ mol(-1). This is identical to the barrier for coalescence of the H2',6' protons of the outer (phenolic) ring reported previously for the thyroid hormones and their analogues. It is proposed that the separate peaks at low temperature are due to resonances for H2,6 in cisoid and transoid conformers which are populated in approximately equal populations. These two peaks are averaged resonances for the individual H2 and H6 protons. Conversion of cisoid to transoid forms can occur via rotation of either the alanyl side chain or the outer ring, from one face of the inner ring to the other. It is proposed that the latter process is the one responsible for the observed coalescence phenomenon. The barrier to rotation of the alanyl side chain is greater than or equal to 37 kJ mol(-1), which is significantly larger than has previously been reported for Csp(2)-Csp(3) bonds in other Ph-CH2-X systems. The recent crystal structure of a hormone agonist bound to the ligand-binding domain of the rat thyroid hormone receptor (Wagner et al. Nature 1995, 378, 690-697) shows the transoid form to be the bound conformation. The significant energy barrier to cisoid/transoid interconversion determined in the current study combined with the tight fit of the hormone to its receptor suggests that interconversion between the forms cannot occur at the receptor site but that selection for the preferred bound form occurs from the 50% population of the transoid form in solution.
Resumo:
A study of spin-orbit mixing and nephelauxetic effects in the electronic spectra of nickel(II)-encapsulating complexes involving mixed nitrogen and sulfur donors is reported. As the number of sulfur donors is systematically varied through the series [Ni(N6-xSx)](2+) (x = 0-6), the spin-forbidden (3)A(2)g --> E-1(g) and (3)A(2g) --> (1)A(1g) transitions undergo a considerable reduction in energy whereas the spin-allowed transitions are relatively unchanged. The [Ni(diAMN(6)sar)](2+) and [Ni(AMN(5)Ssar)](2+) complexes exhibit an unusual band shape for the (3)A(2g) --> T-3(2g) transition which is shown to arise from spin-orbit mixing of the E spin-orbit levels associated with the E-1(g) and T-3(2g) states. A significant differential nephelauxetic effect also arises from the covalency differences between the t(2g) and e(g) orbitals with the result that no single set of Racah B and C interelectron repulsion parameters adequately fit the observed spectra. Using a differential covalency ligand-field model, the spectral transitions are successfully reproduced with three independent variables corresponding to 10Dq and the covalency parameters f(t) and f(e), associated with the t(2g) and e(g) orbitals, respectively. The small decrease in f(t) from unity is largely attributed to central-field covalency effects whereas the dramatic reduction in f(e) with increasing number of sulfur donors is a direct consequence of the increased metal-ligand covalency associated with the sulfur donors. Covalency differences between the t(2g) and e(g) orbitals also result in larger 10Dq values than those obtained simply from the energy of the (3)A(2g) --> T-3(2g) spin-allowed transition.
Resumo:
We have previously shown that H-1 pulsed-field-gradient (PFG) NMR spectroscopy provides a facile method for monitoring protein self-association and can be used, albeit with some caveats, to measure the apparent molecular mass of the diffusant [Dingley et al. (1995) J. Biomol. NMR, 6, 321-328]. In this paper we show that, for N-15-labelled proteins, selection of H-1-N-15 multiple-quantum (MQ) coherences in PFG diffusion experiments provides several advantages over monitoring H-1 single-quantum (SQ) magnetization. First, the use of a gradient-selected MQ filter provides a convenient means of suppressing resonances from both the solvent and unlabelled solutes. Second, H-1-N-15 zero-quantum coherence dephases more rapidly than H-1 SQ coherence under the influence of a PFG. This allows the diffusion coefficients of larger proteins to be measured more readily. Alternatively, the gradient length and/or the diffusion delay may be decreased, thereby reducing signal losses from relaxation. In order to extend the size of macromolecules to which these experiments can be applied, we have developed a new MQ PFG diffusion experiment in which the magnetization is stored as longitudinal two-spin order for most of the diffusion period, thus minimizing sensitivity losses due to transverse relaxation and J-coupling evolution.
Resumo:
objective. To describe the management of patients with long-term central venous catheters (CVCs) during an outbreak of infection due to Pseudomonas putida and Stenotrophomonas maltophilia associated with contaminated heparin catheter-lock solution. design. Descriptive study. setting. Private, 250-bed tertiary-care hospital. methods. In March 2003, we identified 2 febrile cancer patients with P. putida bacteremia. Over 2 days, 7 cases of bacteremia were identified; lots of syringes prefilled with heparin catheter-lock solution, supplied by a compounding pharmacy, were recalled and samples were cultured. More cases of bacteremia appeared during the following days, and any patient who had had a catheter lock infused with the suspect solution was asked to provide blood samples for culture, even if the patient was asymptomatic. Isolates that were recovered from culture were typed by pulsed-field gel electrophoresis. Antimicrobial salvage treatment of long-term CVCs was attempted. results. A total of 154 patients had had their catheter lock infused with solution from the lots that were suspected of being contaminated. Only 48 of these patients had CVCs. By day 7 of the outbreak, 18 of these patients had become symptomatic. Twenty-six of the remaining 30 asymptomatic patients then also provided blood samples for culture, 10 of whom developed fever shortly after samples were collected. Thirty-two patients were identified who had P. putida bacteremia; 9 also had infection due to S. maltophilia. Samples from 1 of the 3 lots of prefilled syringes in use at the time of the outbreak also grew P. putida on culture. Molecular typing identified 3 different clones of P. putida from patients and heparin catheter-lock solution, and 1 clone of S. maltophilia. A total of 27 patients received antimicrobial therapy regimens, some of which included decontamination of the catheter lock with anti- infective lock solution. Of 27 patients, 19 (70%) retained their long-term CVC during the 6-month follow-up period. conclusions. To our knowledge, this is one of the largest prospective experiences in the management of bloodstream infection associated with long-term CVCs. The infections were caused by gram-negative bacilli and were managed without catheter removal, with a high response rate. We emphasize the risks of using intravenous formulations of medications supplied by compounding pharmacies that produce large quantities of drugs.
Resumo:
PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Objectives To evaluate the presence of false flow three-dimensional (3D) power Doppler signals in `flow-free` models. Methods 3D power Doppler datasets were acquired from three different flow-free phantoms (muscle, air and water) with two different transducers and Virtual Organ Computer-aided AnaLysis was used to generate a sphere that was serially applied through the 3D dataset. The vascularization flow index was used to compare artifactual signals at different depths (from 0 to 6 cm) within the different phantoms and at different gain and pulse repetition frequency (PR F) settings. Results Artifactual Doppler signals were seen in all phantoms despite these being flow-free. The pattern was very similar and the degree of artifact appeared to be dependent on the gain and distance from the transducer. False signals were more evident in the far field and increased as the gain was increased, with false signals first appearing with a gain of 1 dB in the air and muscle phantoms. False signals were seen at a lower gain with the water phantom (-15 dB) and these were associated with vertical lines of Doppler artifact that were related to PRF, and disappeared when reflections were attenuated. Conclusions Artifactual Doppler signals are seen in flow-free phantoms and are related to the gain settings and the distance from the transducer. In the in-vivo situation, the lowest gain settings that allow the detection of blood flow and adequate definition of vessel architecture should be used, which invariably means using a setting near or below the middle of the range available. Additionally, observers should be aware of vertical lines when evaluating cystic or liquid-containing structures. Copyright (C) 2010 ISUOC. Published by John Wiley & Sons, Ltd.
Resumo:
Objective: The aim of the study was to study the psychometric properties of the Social Phobia Inventory (SPIN) in its version for the context of Brazilian adults. Methods: A sample of Brazilian university students from the general population (n = 2314) and a sample of university students identified as cases (n = 88) and noncases (n = 90) of social phobia were assessed, using as a parameter the Structured Clinical Interview for the Diagnostic and Statistical Manual of Mental Disorders, Fourth Edition. The different instruments were applied individually in the presence of a rater. Results: The SPIN showed adequate internal consistency (.63-.90) and concurrent validity with different instruments of auto- and hetero-evaluation of social phobia. Discriminative validity showed 0.84 to 0.86 sensitivity and 0.84 to 0.87 specificity for cutoff notes between 19 and 21. Factorial analysis showed the presence of a variable number of factors as a function of the different samples. Conclusions: The version of the SPIN studied is quite adequate for use in the context of Brazilian university students, favoring the screening of social phobia. However, further studies using more diverse samples are needed. (C) 2010 Elsevier Inc. All rights reserved.
Resumo:
PURPOSE. The purpose of this study was to further assess the psychometric qualities of the Mini-Social Phobia Inventory (MS) to screen for social anxiety disorder (SAD). DESIGN AND METHODS. The MS and other self- and clinician-rated scales for anxiety and social anxiety were applied in 2,314 university students and in samples of SAD patients (n = 88) and nonpatients (n = 90). FINDINGS. The MS revealed adequate discriminative validity, internal consistency (alpha = 0.49-0.73), convergent validity with the Social Phobia Inventory, Brief Social Phobia Scale, and Self-Statements During Public Speaking Scale and convergent and divergent validity with the Beck Anxiety Inventory. PRACTICE IMPLICATIONS. The MS has shown to be a fast and efficient screening instrument for SAD in different cultures and contexts.
Resumo:
The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37A degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55A degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations.