The influence of erbium:yttrium-aluminum-garnet laser ablation with variable pulse width on morphology and microleakage of composite restorations
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
19/10/2012
19/10/2012
2010
|
Resumo |
The objective of this study was to evaluate the influence of various pulse widths with different energy parameters of erbium:yttrium-aluminum-garnet (Er:YAG) laser (2.94 mu m) on the morphology and microleakage of cavities restored with composite resin. Identically sized class V cavities were prepared on the buccal surfaces of 54 bovine teeth by high-speed drill (n = 6, control, group 1) and prepared by Er:YAG laser (Fidelis 320A, Fotona, Slovenia) with irradiation parameters of 350 mJ/ 4 Hz or 400 mJ/2 Hz and pulse width: group 2, very short pulse (VSP); group 3, short pulse (SP); group 4, long pulse (LP); group 5, very long pulse (VLP). All cavities were filled with composite resin (Z-250-3 M), stored at 37A degrees C in distilled water, polished after 24 h, and thermally stressed (700 cycles/5-55A degrees C). The teeth were impermeabilized, immersed in 50% silver nitrate solution for 8 h, sectioned longitudinally, and exposed to Photoflood light for 10 min to reveal the stain. The leakage was evaluated under stereomicroscope by three different examiners, in a double-blind fashion, and scored (0-3). The results were analyzed by Kruskal-Wallis test (P > 0.05) and showed that there was no significant differences between the groups tested. Under scanning electron microscopy (SEM) the morphology of the cavities prepared by laser showed irregular enamel margins and dentin internal walls, and a more conservative pattern than that of conventional cavities. The different power settings and pulse widths of Er:YAG laser in cavity preparation had no influence on microleakage of composite resin restorations. |
Identificador |
LASERS IN MEDICAL SCIENCE, v.25, n.6, p.881-889, 2010 0268-8921 http://producao.usp.br/handle/BDPI/25587 10.1007/s10103-009-0736-6 |
Idioma(s) |
eng |
Publicador |
SPRINGER LONDON LTD |
Relação |
Lasers in Medical Science |
Direitos |
closedAccess Copyright SPRINGER LONDON LTD |
Palavras-Chave | #Laser ablation #Erbium:yttrium-aluminum-garnet (Er:YAG) Laser #Scanning electron microscope #Microleakage #Morphology #Pulse width #ER-YAG LASER #CAVITY PREPARATION #ERYAG LASER #RESIN RESTORATIONS #DENTIN SURFACES #BUR PREPARATION #ENAMEL #IRRADIATION #STRENGTH #SYSTEMS #Engineering, Biomedical #Surgery |
Tipo |
article original article publishedVersion |