931 resultados para Signal processing -- Digital techniques


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abnormal intragastric distribution of food (IDF) and a phasic contractility in the proximal stomach have been related to dyspeptic symptoms. Thus, the behaviour of the stomach and the proximal region, in particular, continues to attract attention and demand for reliable and comfortable techniques. The aims of this study were to employ AC Biosus-ceptometry (ACB) and scintigraphy to evaluate IDF and gastric motor activity in humans. Fifteen healthy volunteers ingested 60 mL of yogurt containing 2 mCi of Tc-99m and 4 g of ferrite. Each volunteer had gastric motility and IDF evaluated twice on separate days; on one occasion by ACB and another by scintigraphy. Digital signal processing was performed in MatLab (Mathworks Inc., Natick, MA, USA). Results were expressed as mean +/- SD. Similar results of distal accumulation time (P < 0.001) were obtained for scintigraphy (6.93 +/- 3.25 min) and for ACB (7.04 +/- 3.65 min). Fast Fourier Transform revealed two dominant frequencies (P > 0.9). Besides the well-know frequency of 3 cpm, our results showed identical frequencies in proximal stomach recordings (P < 0.001) for scintigraphic (1.01 +/- 0.01 cpm) and ACB (0.98 +/- 0.06 cpm). In summary, our data showed that scintigraphy and ACB are promising techniques to evaluate several aspects of gastric motility. Moreover, ACB is non-invasive, radiation-free and deserves the same importance as conventional methods for this kind of analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work it is introduced a new approach to calculate the density of liquids in terms of the energies of the acoustic signals. This method is compared to other methods in the time domain (peak-to-peak amplitudes) and frequency domain magnitudes at a single frequency. It is used a measurement cell based on a multiple reflection technique, and it is developed an acoustic model for the cell. Simulations and experiments using several liquids are presented, showing that the energy method a less sensitive to noise than the other techniques. The relative errors in the density are smaller than 0.2% when compared to the values measured with a pycnometer.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents some results of the application on Evolvable Hardware (EHW) in the area of voice recognition. Evolvable Hardware is able to change inner connections, using genetic learning techniques, adapting its own functionality to external condition changing. This technique became feasible by the improvement of the Programmable Logic Devices. Nowadays, it is possible to have, in a single device, the ability to change, on-line and in real-time, part of its own circuit. This work proposes a reconfigurable architecture of a system that is able to receive voice commands to execute special tasks as, to help handicapped persons in their daily home routines. The idea is to collect several voice samples, process them through algorithms based on Mel - Ceptrais theory to obtain their numerical coefficients for each sample, which, compose the universe of search used by genetic algorithm. The voice patterns considered, are limited to seven sustained Portuguese vowel phonemes (a, eh, e, i, oh, o, u).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper adresses the problem on processing biological data such as cardiac beats, audio and ultrasonic range, calculating wavelet coefficients in real time, with processor clock running at frequency of present ASIC's and FPGA. The Paralell Filter Architecture for DWT has been improved, calculating wavelet coefficients in real time with hardware reduced to 60%. The new architecture, which also processes IDWT, is implemented with the Radix-2 or the Booth-Wallace Constant multipliers. Including series memory register banks, one integrated circuit Signal Analyzer, ultrasonic range, is presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper discusses two pitch detection algorithms (PDA) for simple audio signals which are based on zero-cross rate (ZCR) and autocorrelation function (ACF). As it is well known, pitch detection methods based on ZCR and ACF are widely used in signal processing. This work shows some features and problems in using these methods, as well as some improvements developed to increase their performance. © 2008 IEEE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A correction procedure based on digital signal processing theory is proposed to smooth the numeric oscillations in electromagnetic transient simulation results from transmission line modeling based on an equivalent representation by lumped parameters. The proposed improvement to this well-known line representation is carried out with an Finite Impulse Response (FIR) digital filter used to exclude the high-frequency components associated with the spurious numeric oscillations. To prove the efficacy of this correction method, a well-established frequency-dependent line representation using state equations is modeled with an FIR filter included in the model. The results obtained from the state-space model with and without the FIR filtering are compared with the results simulated by a line model based on distributed parameters and inverse transforms. Finally, the line model integrated with the FIR filtering is also tested and validated based on simulations that include nonlinear and time-variable elements. © 2012 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Digital techniques have been developed and validated to assess semiquantitatively immunohistochemical nuclear staining. Currently visual classification is the standard for qualitative nuclear evaluation. Analysis of pixels that represents the immunohistochemical labeling can be more sensitive, reproducible and objective than visual grading. This study compared two semiquantitative techniques of digital image analysis with three techniques of visual analysis imaging to estimate the p53 nuclear immunostaining. Methods: Sixty-three sun-exposed forearm-skin biopsies were photographed and submitted to three visual analyses of images: the qualitative visual evaluation method (0 to 4 +), the percentage of labeled nuclei and HSCORE. Digital image analysis was performed using ImageJ 1.45p; the density of nuclei was scored per ephitelial area (DensNU) and the pixel density was established in marked suprabasal epithelium (DensPSB). Results: Statistical significance was found in: the agreement and correlation among the visual estimates of evaluators, correlation among the median visual score of the evaluators, the HSCORE and the percentage of marked nuclei with the DensNU and DensPSB estimates. DensNU was strongly correlated to the percentage of p53-marked nuclei in the epidermis, and DensPSB with the HSCORE. Conclusion: The parameters presented herein can be applied in routine analysis of immunohistochemical nuclear staining of epidermis. © 2012 John Wiley & Sons A/S.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O presente trabalho trata da filtragem e reconstrução de sinais em frequência intermediária usando FPGA. É feito o desenvolvimento de algoritmos usando processamento digital de sinais e também a implementação dos mesmos, constando desde o projeto da placa de circuito impresso, montagem e teste. O texto apresenta um breve estudo de amostragem e reconstrução de sinais em geral. Especial atenção é dada à amostragem de sinais banda-passante e à análise de questões práticas de reconstrução de sinais em frequência intermediária. Dois sistemas de reconstrução de sinais baseados em processamento digital de sinais, mais especificamente reamostragem no domínio discreto, são apresentados e analisados. São também descritas teorias de processos de montagem e soldagem de placas eletrônicas com objetivo de definir uma metodologia de projeto, montagem e soldagem de placas eletrônicas. Tal metodologia é aplicada no projeto e manufatura do protótipo de um módulo de filtragem digital para repetidores de telefonia celular. O projeto, implementado usando FPGA, é baseado nos dois sistemas supracitados. Ao final do texto, resultados obtidos em experimentos de filtragem digital e reconstrução de sinais em frequência intermediária com o protótipo desenvolvido são apresentados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Este trabalho apresenta um método rápido de inversão de matrizes densas, e uma possível aplicação com métodos de Vectoring, em pré-codificação e cancelamento de crosstalk de sistemas xDSL. A família de tecnologias xDSL utiliza os pares trançados de fios de cobre telefônicos como meio físico para transmitir dados digitais. O crosstalk é a principal causa de degradação de sinais na mais nova geração de sistemas xDSL, o G.fast, e para combatê-lo são utilizadas técnicas de pré-codificação e cancelamento, chamadas de Vectoring. O método proposto, chamado de GSGR, consiste em uma abordagem diferente para o método clássico de Squared Givens Rotations (SGR), adequado a implementações em plataformas embarcadas de processamento digital de sinais. Foram realizados testes comparativos do método GSGR com métodos diretos clássicos de inversão, utilizando uma plataforma digital multicore baseada no chip TI DSP TMS320C6670 e a plataforma de software Matlab. Os resultados dos testes de inversão de matrizes usando dados reais e dados simulados mostraram que o GSGR foi superior em velocidade de execução sem apresentar perdas significativas de acurácia para a aplicação em sistemas xDSL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The main objective is to create a software, using C++ language, for reading and exhibiting in a graphic an Electrocardiogram (ECG) wave. The data is recorded as a FM modulated signal and compressed using Adaptive Differential Pulse Code Modulation (ADPCM). The signal have this characteristics because it was acquired using an experimental equipment, this equipment is the result of research made by the professor who supervised this work. FM demodulation techniques in discrete time, discrete filters and digital signal processing are some of the topics that can be found in this essay. Some concepts about the human heart and about ECG waves are also briefly introduced. These concepts are necessary for understanding the final evaluation of the software performance. The development is partly made using MATLAB. Most of the functions that are used on the software are first tested and designed in MATLAB environment. In the end, an evaluation is done comparing the results that are expected with the ones that MATLAB presents and the ones that the developed software presents

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Synthetic-heterodyne demodulation is a useful technique for dynamic displacement and velocity detection in interferometric sensors, as it can provide an output signal that is immune to interferometric drift. With the advent of cost-effective, high-speed real-time signal-processing systems and software, processing of the complex signals encountered in interferometry has become more feasible. In synthetic heterodyne, to obtain the actual dynamic displacement or vibration of the object under test requires knowledge of the interferometer visibility and also the argument of two Bessel functions. In this paper, a method is described for determining the former and setting the Bessel function argument to a set value, which ensures maximum sensitivity. Conventional synthetic-heterodyne demodulation requires the use of two in-phase local oscillators; however, the relative phase of these oscillators relative to the interferometric signal is unknown. It is shown that, by using two additional quadrature local oscillators, a demodulated signal can be obtained that is independent of this phase difference. The experimental interferometer is aMichelson configuration using a visible single-mode laser, whose current is sinusoidally modulated at a frequency of 20 kHz. The detected interferometer output is acquired using a 250 kHz analog-to-digital converter and processed in real time. The system is used to measure the displacement sensitivity frequency response and linearity of a piezoelectric mirror shifter over a range of 500 Hz to 10 kHz. The experimental results show good agreement with two data-obtained independent techniques: the signal coincidence and denominated n-commuted Pernick method.