939 resultados para Short-circuit faults diagnostic


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, the validity of'single fault assumption in deriving diagnostic test sets is examined with respect to crosspoint faults in programmable logic arrays (PLA's). The control input procedure developed here can be used to convert PLA's having undetectable crosspoint faults to crosspoint-irredundant PLA's for testing purposes. All crosspoints will be testable in crosspoint-irredundant PLA's. The control inputs are used as extra variables during testing. They are maintained at logic I during normal operation. A useful heuristic for obtaining a near-minimal number of control inputs is suggested. Expressions for calculating bounds on the number of control inputs have also been obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose In the oncology population where malnutrition prevalence is high, more descriptive screening tools can provide further information to assist triaging and capture acute change. The Patient-Generated Subjective Global Assessment Short Form (PG-SGA SF) is a component of a nutritional assessment tool which could be used for descriptive nutrition screening. The purpose of this study was to conduct a secondary analysis of nutrition screening and assessment data to identify the most relevant information contributing to the PG-SGA SF to identify malnutrition risk with high sensitivity and specificity. Methods This was an observational, cross-sectional study of 300 consecutive adult patients receiving ambulatory anti-cancer treatment at an Australian tertiary hospital. Anthropometric and patient descriptive data were collected. The scored PG-SGA generated a score for nutritional risk (PG-SGA SF) and a global rating for nutrition status. Receiver operating characteristic curves (ROC) were generated to determine optimal cut-off scores for combinations of the PG-SGA SF boxes with the greatest sensitivity and specificity for predicting malnutrition according to scored PG-SGA global rating. Results The additive scores of boxes 1–3 had the highest sensitivity (90.2 %) while maintaining satisfactory specificity (67.5 %) and demonstrating high diagnostic value (AUC = 0.85, 95 % CI = 0.81–0.89). The inclusion of box 4 (PG-SGA SF) did not add further value as a screening tool (AUC = 0.85, 95 % CI = 0.80–0.89; sensitivity 80.4 %; specificity 72.3 %). Conclusions The validity of the PG-SGA SF in chemotherapy outpatients was confirmed. The present study however demonstrated that the functional capacity question (box 4) does not improve the overall discriminatory value of the PG-SGA SF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Power system disturbances are often caused by faults on transmission lines. When faults occur in a power system, the protective relays detect the fault and initiate tripping of appropriate circuit breakers, which isolate the affected part from the rest of the power system. Generally Extra High Voltage (EHV) transmission substations in power systems are connected with multiple transmission lines to neighboring substations. In some cases mal-operation of relays can happen under varying operating conditions, because of inappropriate coordination of relay settings. Due to these actions the power system margins for contingencies are decreasing. Hence, power system protective relaying reliability becomes increasingly important. In this paper an approach is presented using Support Vector Machine (SVM) as an intelligent tool for identifying the faulted line that is emanating from a substation and finding the distance from the substation. Results on 24-bus equivalent EHV system, part of Indian southern grid, are presented for illustration purpose. This approach is particularly important to avoid mal-operation of relays following a disturbance in the neighboring line connected to the same substation and assuring secure operation of the power systems.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Candida albicans is a commensal opportunistic pathogen, which can cause superficial infections as well as systemic infections in immuocompromised hosts. Among nosocomial fungal infections, infections by C. albicans are associated with highest mortality rates even though incidence of infections by other related species is on the rise world over. Since C. albicans and other Candida species differ in their susceptibility to antifungal drug treatment, it is crucial to accurately identify the species for effective drug treatment. Most diagnostic tests that differentiate between C. albicans and other Candida species are time consuming, as they necessarily involve laboratory culturing. Others, which employ highly sensitive PCR based technologies often, yield false positives which is equally dangerous since that leads to unnecessary antifungal treatment. This is the first report of phage display technology based identification of short peptide sequences that can distinguish C. albicans from other closely related species. The peptides also show high degree of specificity towards its different morphological forms. Using fluorescence microscopy, we show that the peptides bind on the surface of these cells and obtained clones that could even specifically bind to only specific regions of cells indicating restricted distribution of the epitopes. What was peculiar and interesting was that the epitopes were carbohydrate in nature. This gives insight into the complexity of the carbohydrate composition of fungal cell walls. In an ELISA format these peptides allow specific detection of relatively small numbers of C. albicans cells. Hence, if used in combination, such a test could help accurate diagnosis and allow physicians to initiate appropriate drug therapy on time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, a physically based analytical quantum linear threshold voltage model for short channel quad gate MOSFETs is developed. The proposed model, which is suitable for circuit simulation, is based on the analytical solution of 3-D Poisson and 2-D Schrodinger equation. Proposed model is fully validated against the professional numerical device simulator for a wide range of device geometries and also used to analyze the effect of geometry variation on the threshold voltage.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Transfer function coefficients (TFC) are widely used to test linear analog circuits for parametric and catastrophic faults. This paper presents closed form expressions for an upper bound on the defect level (DL) and a lower bound on fault coverage (FC) achievable in TFC based test method. The computed bounds have been tested and validated on several benchmark circuits. Further, application of these bounds to scalable RC ladder networks reveal a number of interesting characteristics. The approach adopted here is general and can be extended to find bounds of DL and FC of other parametric test methods for linear and non-linear circuits.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents an approach for identifying the faulted line section and fault location on transmission systems using support vector machines (SVMs) for diagnosis/post-fault analysis purpose. Power system disturbances are often caused by faults on transmission lines. When fault occurs on a transmission system, the protective relay detects the fault and initiates the tripping operation, which isolates the affected part from the rest of the power system. Based on the fault section identified, rapid and corrective restoration procedures can thus be taken to minimize the power interruption and limit the impact of outage on the system. The approach is particularly important for post-fault diagnosis of any mal-operation of relays following a disturbance in the neighboring line connected to the same substation. This may help in improving the fault monitoring/diagnosis process, thus assuring secure operation of the power systems. In this paper we compare SVMs with radial basis function neural networks (RBFNN) in data sets corresponding to different faults on a transmission system. Classification and regression accuracy is reported for both strategies. Studies on a practical 24-Bus equivalent EHV transmission system of the Indian Southern region is presented for indicating the improved generalization with the large margin classifiers in enhancing the efficacy of the chosen model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A set of formulas is derived from general circuit constants which facilitates formation of the impedance matrix of a power system by the bus-impedance method. The errors associated with the lumpedparameter representation of a transmission line are thereby eliminated. The formulas are valid for short lines also, if the relevant general circuit constants are employed. The mutual impedance between the added line and the existing system is not considered, but the approach suggested can well be extended to it.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of incorporation of a centrally positioned Ac(6)c-Xxx segment where Xxx = (L)Val/(D)Val into a host oligopeptide composed of L-amino acid residues has been investigated. Studies of four designed octapeptides Boc-Leu-Phe-Val-Ac(6)c-Xxx-Leu-Phe-Val-OMe (Xxx = (D)Val 1, (L)Val 2) Boc-Leu-Val-Val-Ac(6)c-Xxx-Leu-Val-Val-OMe (Xxx = (D)Val 3, (L)Val 4) are reported. Diagnostic nuclear Overhouse effects characteristic of hairpin conformations are observed for Xxx = (D)Val peptides (1 and 3) while continuous helical conformation characterized by sequential NiH <-> Ni+1H NOEs are favored for Xxx = (L)Val peptides (2 and 4) in methanol solutions. Temperature co-efficient of NH chemical shifts are in agreement with distinctly different conformational preferences upon changing the configuration of the residue at position 5. Crystal structures of peptides 2 and 4 (Xxx = (L)Val) establish helical conformations in the solid state, in agreement with the structures deduced from NMR data. The results support the design principle that centrally positioned type I beta-turns may be used to nucleate helices in short peptides, while type I' beta-turns can facilitate folding into beta-hairpins.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present the circuit board integration of a self-healing mechanism to repair open faults. The electric field driven mechanism physically restores fractured interconnects in electronic circuits and has the ability to solve mazes. The repair is performed by conductive particles dispersed in an insulating fluid. We demonstrate the integration of the healing module onto printed circuit boards and the ability of maze solving. We model and perform experiments on the influence of the geometry of conductive particles as well as the terminal impedances of the route on the healing efficiency. The typical heal rate is 10 mu m/s with healed route having mean resistance of 8 k Omega across a 200 micron gap and depending on the materials and concentrations used. (C) 2015 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are 34 species of the family Corixidae (Hemiptera Heteroptera) in Britain and Ireland of which Sigara striata and Sigara dorsalis are the only two British representatives. In this article the authors briefly consider a range of diagnostic features that may be used to separate British specimens of striata from dorsalis. Most of these morphological features have been used in keys to the British species of the subgenus Sigara sensu strictu. A scoring system has also been devised to facilitate the identification of individuals from the southeast of England, although it is applicable to the whole of the British Isles, and a new (short) key is presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a time-stepping shaker modeling scheme. The new method improves the accuracy of analysis of armature-position-dependent inductances and force factors, analysis of axial variation of current density in copper plates (short-circuited turns), and analysis of cooling holes in the magnetic circuit. Linear movement modeling allows armature position to be precisely included in the shaker analysis. A more accurate calculation of eddy currents in the coupled circuit is in particular crucial for the shaker analysis in a mid-or high-frequency operation range. Large currents in a shaker, including eddy currents, incur large Joule losses, which in turn require the use of a cooling system to keep temperature at bay. Sizable cooling holes have influence on the saturation state of iron poles, and hence have to be properly taken into account.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We wish to design a diagnostic for a device from knowledge of its structure and function. the diagnostic should achieve both coverage of the faults that can occur in the device, and should strive to achieve specificity in its diagnosis when it detects a fault. A system is described that uses a simple model of hardware structure and function, representing the device in terms of its internal primitive functions and connections. The system designs a diagnostic in three steps. First, an extension of path sensitization is used to design a test for each of the connections in teh device. Next, the resulting tests are improved by increasing their specificity. Finally the tests are ordered so that each relies on the fewest possible connections. We describe an implementation of this system and show examples of the results for some simple devices.