960 resultados para STRICTLY POSITIVE REAL MATRICES


Relevância:

30.00% 30.00%

Publicador:

Resumo:

1) Background: The most common methods to evaluate clarithromycin resistance is the E-Test, but is time consuming. Resistance of Hp to clarithromycin is due to point mutations in the 23S rRNA. Eight different point mutations have been related to CH resistance, but the large majority of the clarithromycin resistance depends on three point mutations (A2142C, A2142G and A2143G). A novel PCR-based clarithromycin resistance assays, even on paraffin-embedded biopsy specimens, have been proposed. Aims: to assess clarithromycin resistance detecting these point mutation (E-Test as a reference method);secondly, to investigate relation with MIC values. Methods: Paraffin-embedded biopsies of patients Hp-positive were retrieved. The A2142C, A2142G and A2143G point mutations were detected by molecular analysis after DNA extraction by using a TaqMan real-time PCR. Results: The study enrolled 86 patients: 46 resistant and 40 sensible to CH. The Hp status was evaluated at endoscopy, by rapid urease test (RUT), histology and hp culture. According to real-time PCR, 37 specimens were susceptible to clarithromycin (wild type dna) whilst the remaining 49 specimens (57%) were resistant. A2143G is the most frequent mutation. A2142C always express a resistant phenotype and A2142G leads to a resitant phenotype only if homozigous. 2) Background: Colonoscopy work-load for endoscopy services is increasing due to colorectal cancer prevention. We tested a combination of faecal tests to improve accuracy and prioritize the access to colonoscopy. Methods: we tested a combination of fecal tests (FOBT, M2-PK and calprotectin) in a group of 280 patients requiring colonoscopy. Results: 47 patients had CRC and 85 had advanced adenoma/s at colonoscopy/histology. In case of single test, for CRC detection FOBT was the test with the highest specificity and PPV, M2-PK had the highest sensitivity and higher NPV. Combination was more interesting in term of PPV. And the best combination of tests was i-FOBT + M2-PK.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The idea of balancing the resources spent in the acquisition and encoding of natural signals strictly to their intrinsic information content has interested nearly a decade of research under the name of compressed sensing. In this doctoral dissertation we develop some extensions and improvements upon this technique's foundations, by modifying the random sensing matrices on which the signals of interest are projected to achieve different objectives. Firstly, we propose two methods for the adaptation of sensing matrix ensembles to the second-order moments of natural signals. These techniques leverage the maximisation of different proxies for the quantity of information acquired by compressed sensing, and are efficiently applied in the encoding of electrocardiographic tracks with minimum-complexity digital hardware. Secondly, we focus on the possibility of using compressed sensing as a method to provide a partial, yet cryptanalysis-resistant form of encryption; in this context, we show how a random matrix generation strategy with a controlled amount of perturbations can be used to distinguish between multiple user classes with different quality of access to the encrypted information content. Finally, we explore the application of compressed sensing in the design of a multispectral imager, by implementing an optical scheme that entails a coded aperture array and Fabry-Pérot spectral filters. The signal recoveries obtained by processing real-world measurements show promising results, that leave room for an improvement of the sensing matrix calibration problem in the devised imager.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Computing the weighted geometric mean of large sparse matrices is an operation that tends to become rapidly intractable, when the size of the matrices involved grows. However, if we are not interested in the computation of the matrix function itself, but just in that of its product times a vector, the problem turns simpler and there is a chance to solve it even when the matrix mean would actually be impossible to compute. Our interest is motivated by the fact that this calculation has some practical applications, related to the preconditioning of some operators arising in domain decomposition of elliptic problems. In this thesis, we explore how such a computation can be efficiently performed. First, we exploit the properties of the weighted geometric mean and find several equivalent ways to express it through real powers of a matrix. Hence, we focus our attention on matrix powers and examine how well-known techniques can be adapted to the solution of the problem at hand. In particular, we consider two broad families of approaches for the computation of f(A) v, namely quadrature formulae and Krylov subspace methods, and generalize them to the pencil case f(A\B) v. Finally, we provide an extensive experimental evaluation of the proposed algorithms and also try to assess how convergence speed and execution time are influenced by some characteristics of the input matrices. Our results suggest that a few elements have some bearing on the performance and that, although there is no best choice in general, knowing the conditioning and the sparsity of the arguments beforehand can considerably help in choosing the best strategy to tackle the problem.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background Urinary tract infections (UTI) are frequent in outpatients. Fast pathogen identification is mandatory for shortening the time of discomfort and preventing serious complications. Urine culture needs up to 48 hours until pathogen identification. Consequently, the initial antibiotic regimen is empirical. Aim To evaluate the feasibility of qualitative urine pathogen identification by a commercially available real-time PCR blood pathogen test (SeptiFast®) and to compare the results with dipslide and microbiological culture. Design of study Pilot study with prospectively collected urine samples. Setting University hospital. Methods 82 prospectively collected urine samples from 81 patients with suspected UTI were included. Dipslide urine culture was followed by microbiological pathogen identification in dipslide positive samples. In parallel, qualitative DNA based pathogen identification (SeptiFast®) was performed in all samples. Results 61 samples were SeptiFast® positive, whereas 67 samples were dipslide culture positive. The inter-methodological concordance of positive and negative findings in the gram+, gram- and fungi sector was 371/410 (90%), 477/492 (97%) and 238/246 (97%), respectively. Sensitivity and specificity of the SeptiFast® test for the detection of an infection was 0.82 and 0.60, respectively. SeptiFast® pathogen identifications were available at least 43 hours prior to culture results. Conclusion The SeptiFast® platform identified bacterial DNA in urine specimens considerably faster compared to conventional culture. For UTI diagnosis sensitivity and specificity is limited by its present qualitative setup which does not allow pathogen quantification. Future quantitative assays may hold promise for PCR based UTI pathogen identification as a supplementation of conventional culture methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We tested the use of multiplex real-time PCR for detection and quantification of Campylobacter jejuni and Campylobacter coli on broiler carcass neck skin samples collected during 2008 from slaughterhouses in Switzerland. Results from an established TaqMan assay based on two different targets (hipO and ceuE for C. jejuni and C. coli, respectively) were corroborated with data from a newly developed assay based on a single-nucleotide polymorphism in the fusA gene, which allows differentiation between C. jejuni and C. coli. Both multiplex real-time PCRs were applied simultaneously for direct detection, differentiation, and quantification of Campylobacter from 351 neck skin samples and compared with culture methods. There was good correlation in detection and enumeration between real-time PCR results and quantitative culture, with real-time PCR being more sensitive. Overall, 251 (71.5%) of the samples were PCR positive for Campylobacter, with 211 (60.1%) in the hipO-ceuE assays, 244 (69.5%) in the fusA assay, and 204 (58.1%) of them being positive in both PCR assays. Thus, the fusA assay was similarly sensitive to the enrichment culture (72.4% positive); however, it is faster and allows for quantification. In addition, real-time PCR allowed for species differentiation; roughly 60% of positive samples contained C. jejuni, less than 10% C. coli, and more than 30% contained both species. Real-time PCR proved to be a suitable method for direct detection, quantification, and differentiation of Campylobacter from carcasses, and could permit time-efficient surveillance of these zoonotic agents.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A real-time polymerase chain reaction (PCR) assay was developed for rapid identification of Bacillus anthracis in environmental samples. These samples often harbor Bacillus cereus bacteria closely related to B. anthracis, which may hinder its specific identification by resulting in false positive signals. The assay consists of two duplex real-time PCR: the first PCR allows amplification of a sequence specific of the B. cereus group (B. anthracis, B. cereus, Bacillus thuringiensis, Bacillus weihenstephanensis, Bacillus pseudomycoides, and Bacillus mycoides) within the phosphoenolpyruvate/sugar phosphotransferase system I gene and a B. anthracis specific single nucleotide polymorphism within the adenylosuccinate synthetase gene. The second real-time PCR assay targets the lethal factor gene from virulence plasmid pXO1 and the capsule synthesis gene from virulence plasmid pXO2. Specificity of the assay is enhanced by the use of minor groove binding probes and/or locked nucleic acids probes. The assay was validated on 304 bacterial strains including 37 B. anthracis, 67 B. cereus group, 54 strains of non-cereus group Bacillus, and 146 Gram-positive and Gram-negative bacteria strains. The assay was performed on various environmental samples spiked with B. anthracis or B. cereus spores. The assay allowed an accurate identification of B. anthracis in environmental samples. This study provides a rapid and reliable method for improving rapid identification of B. anthracis in field operational conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Here we determined the analytical sensitivities of broad-range real-time PCR-based assays employing one of three different genomic DNA extraction protocols in combination with one of three different primer pairs targeting the 16S rRNA gene to detect a panel of 22 bacterial species. DNA extraction protocol III, using lysozyme, lysostaphin, and proteinase K, followed by PCR with the primer pair Bak11W/Bak2, giving amplicons of 796 bp in length, showed the best overall sensitivity, detecting DNA of 82% of the strains investigated at concentrations of < or =10(2) CFU in water per reaction. DNA extraction protocols I and II, using less enzyme treatment, combined with other primer pairs giving shorter amplicons of 466 bp and 342 or 346 bp, respectively, were slightly more sensitive for the detection of gram-negative but less sensitive for the detection of gram-positive bacteria. The obstacle of detecting background DNA in blood samples spiked with bacteria was circumvented by introducing a broad-range hybridization probe, and this preserved the minimal detection limits observed in samples devoid of blood. Finally, sequencing of the amplicons generated using the primer pair Bak11W/Bak2 allowed species identification of the detected bacterial DNA. Thus, broad-spectrum PCR targeting the 16S rRNA gene in the quantitative real-time format can achieve an analytical sensitivity of 1 to 10 CFU per reaction in water, avoid detection of background DNA with the introduction of a broad-range probe, and generate amplicons that allow species identification of the detected bacterial DNA by sequencing. These prerequisites are important for its application to blood-containing patient samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The association of simian virus 40 (SV40) with malignant pleural mesothelioma is currently under debate. In some malignancies of viral aetiology, viral DNA can be detected in the patients' serum or plasma. To characterize the prevalence of SV40 in Swiss mesothelioma patients, we optimized a real-time PCR for quantitative detection of SV40 DNA in plasma, and used a monoclonal antibody for immunohistochemical detection of SV40 in mesothelioma tissue microarrays. Real-time PCR was linear over five orders of magnitude, and sensitive to a single gene copy. Repeat PCR determinations showed excellent reproducibility. However, SV40 status varied for independent DNA isolates of single samples. We noted that SV40 detection rates by PCR were drastically reduced by the implementation of strict room compartmentalization and decontamination procedures. Therefore, we systematically addressed common sources of contamination and found no cross-reactivity with DNA of other polyomaviruses. Contamination during PCR was rare and plasmid contamination was infrequent. SV40 DNA was reproducibly detected in only 4 of 78 (5.1%) plasma samples. SV40 DNA levels were low and not consistently observed in paired plasma and tumour samples from the same patient. Immunohistochemical analysis revealed a weak but reproducible SV40 staining in 16 of 341 (4.7%) mesotheliomas. Our data support the occurrence of non-reproducible SV40 PCR amplifications and underscore the importance of proper sample handling and analysis. SV40 DNA and protein were found at low prevalence (5%) in plasma and tumour tissue, respectively. This suggests that SV40 does not appear to play a major role in the development of mesothelioma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Besnoitia besnoiti, an apicomplexan protozoan parasite, is the causative agent of bovine besnoitiosis. This infection may dramatically affect body condition, and, in males, lead to irreversible infertility. While identification of clinical cases and their histopathological confirmation is relatively simple to carry out, finding subclinical forms of infection is more difficult, thus a more sensitive test for the identification of the etiological agent may be an appropriate diagnostic tool. We have developed the ITS1 rDNA-sequence-based conventional and real-time PCR which are highly sensitive and specific for the detection of B. besnoiti infection in cattle. A recombinant internal positive control was introduced to assess possible sample-related inhibitory effects during the amplification reaction and, in order to prevent false-positive results, a pre-PCR treatment of potentially contaminating dU-containing PCR product with uracil-DNA-glycosylase (UDG) was followed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Typing of Clostridium perfringens strains by PCR-based determination of toxin genes proved to be a reliable method for diagnosis of enterotoxaemia in various animal species. We report the establishment and validation of three real-time fluorogenic (TaqMan) multiplex PCRs for the detection of C. perfringens alpha-, beta-, beta2-, epsilon-, entero- and iota-toxin genes. The composition of the PCRs was chosen with regard to robustness of the assays and in order to increase sensitivity compared to the conventional simplex PCRs. The combination of probe dyes selected for the real-time assays (FAM/TAMRA, Cy-5/BHQ-2 and VIC/TAMRA) as well as the designation of the chromosome-borne alpha-toxin as internal positive control allowed the creation of highly specific and sensitive, as well as time and cost effective PCRs. One hundred and three strains of C. perfringens isolated in Switzerland derived from clinical or suspected cases of enterotoxaemia in 10 different animal species were tested. The toxin genotypes were in agreement in both the conventional PCRs and the newly designed multiplex PCRs. Furthermore, the real-time PCR carried out as simplex allows to quantitate the copy numbers of plasmid-borne toxin genes in relation to the chromosomally located alpha-toxin gene.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

MATERIALS AND METHODS: In a pilot study, results of real-time broad-range (16S rRNA) polymerase chain reaction (PCR) performed on 45 blood samples of pediatric cancer patients with fever and neutropenia were compared with blood culture results. RESULTS: The PCR assay used, having proven a high sensitivity in artificially spiked blood samples, was positive in only three of ten blood culture-positive samples, and it was positive in 10 of 35 (29%) culture-negative samples. CONCLUSION: This broad-range PCR assay, which may identify not-grown bacteria potentially contributing to fever, needs improvement in sensitivity, and different reasons for positive PCR in negative blood culture samples need to be assessed before clinical application.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Control of brucellosis in livestock, wildlife and humans depends on the reliability of the methods used for detection and identification of bacteria. In the present study, we describe the evaluation of the recently established real-time PCR assay based on the Brucella-specific insertion sequence IS711 with blood samples from 199 wild boars (first group of animals) and tissue samples from 53 wild boars (second group of animals) collected in Switzerland. Results from IS711 real-time PCR were compared to those obtained by bacterial isolation, Rose Bengal Test (RBT), competitive ELISA (c-ELISA) and indirect ELISA (i-ELISA). RESULTS: In the first group of animals, IS711 real-time PCR detected infection in 11.1% (16/144) of wild boars that were serologically negative. Serological tests showed different sensitivities [RBT 15.6%, c-ELISA 7.5% and i-ELISA 5.5%] and only 2% of blood samples were positive with all three tests, which makes interpretation of the serological results very difficult. Regarding the second group of animals, the IS711 real-time PCR detected infection in 26% of animals, while Brucella spp. could be isolated from tissues of only 9.4% of the animals. CONCLUSION: The results presented here indicate that IS711 real-time PCR assay is a specific and sensitive tool for detection of Brucella spp. infections in wild boars. For this reason, we propose the employment of IS711 real-time PCR as a complementary tool in brucellosis screening programs and for confirmation of diagnosis in doubtful cases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Enzootic pneumonia (EP) of pigs, caused by Mycoplasma hyopneumoniae has been a notifiable disease in Switzerland since May 2003. The diagnosis of EP has been based on multiple methods, including clinical, bacteriological and epidemiological findings as well as pathological examination of lungs (mosaic diagnosis). With the recent development of a real-time PCR (rtPCR) assay with 2 target sequences a new detection method for M. hyopneumoniae became available. This assay was tested for its applicability to nasal swab material from live animals. Pigs from 74 herds (average 10 pigs per herd) were tested. Using the mosaic diagnosis, 22 herds were classified as EP positive and 52 as EP negative. From the 730 collected swab samples we were able to demonstrate that the rtPCR test was 100% specific. In cases of cough the sensitivity on herd level of the rtPCR is 100%. On single animal level and in herds without cough the sensitivity was lower. In such cases, only a positive result would be proof for an infection with M. hyopneumoniae. Our study shows that the rtPCR on nasal swabs from live pigs allows a fast and accurate diagnosis in cases of suspected EP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to improve the diagnosis of enzootic pneumonia (EP) in pigs two real-time polymerase chain reaction (rtPCR) assays for the detection of Mycoplasma hyopneumoniae in bronchial swabs from lung necropsies were established and validated in parallel. As a gold standard, the current "mosaic diagnosis" was taken, including epidemiological tracing, clinical signs, macro- and histopathological lesions of the lungs and immunofluorescence. One rtPCR is targeting a repeated DNA element of the M. hyopneumoniae genome (REP assay), the other a putative ABC transporter gene (ABC assay). Both assays were shown to be specific for M. hyopneumoniae and did not cross react with other bacteria and mollicutes from pig. With material from pigs of defined EP-negative farms the two assays showed to be 100% specific. When testing lungs from pig farms with EP, the REP assay detected 50% and the ABC assay 90% of the farms as positive. Both tests together detected all positive farms. Within a positive herd the two assays tested similarly with on average over 90% of the lung samples analysed from a single farm showing positive scores. A series of samples with suspicion of EP and samples from pigs with diseases other than respiratory taken from current routine diagnostic was assayed. None of the assays showed false positive results. The sensitivities in this sample group were 50% for the REP and 70% for the ABC assays and for both assays together 85%. The two assays run in parallel are therefore a valuable tool for the improvement of the current diagnosis of EP.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT Aims: ID1 is an important component of the MET-SRC signaling pathway, which is a regulator of cell migration and invasion. We hypothesized that the ALK/MET inhibitor crizotinib inhibits migration via MET-SRC-ID1, rather than ALK. Materials & methods: We used ALK fusion-positive and -negative lung cancer cell lines; crizotinib, PHA-665752, and saracatinib, and stable transfection with shMET. We performed western blotting for p-ALK, ALK, p-MET, MET, p-SRC, SRC and ID1, and quantitative real-time PCR for ID1. Results: Crizotinib decreased p-MET, p-SRC and ID1 levels in ALK- and or MET-positive cell lines and inhibited cell migration. Knockdown of MET was comparable with the effect of crizotinib. Conclusion: The effects of crizotinib on ID1 expression and cancer cell migration were associated with the presence of activated MET, rather than ALK fusion.