998 resultados para Radiology, Medical


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The announcement in the 2009 federal budget to allow nurse practitioners and midwives access to the Pharmaceutical Benefits Scheme (PBS) and the Medicare Benefits Scheme,1and the subsequent announcement of a November 2010 start date,2has brought non-medical prescribing into the public arena. Non-medical prescribing is not a new concept in Australia as nurse practitioners, podiatrists and optometrists have been authorised to prescribe under various state legislations for some time. However, state legislation is not uniform in relation to authorisation or formulary. Midwives are currently seeking prescribing rights,3and other groups such as physiotherapists and pharmacists are likely to seek them in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Noise can be defined as unwanted sound. It may adversely affect the health and well-being of individuals. Noise sensitivity is a personality trait covering attitudes towards noise in general and a predictor of noise annoyance. Noise sensitive individuals are more affected by noise than less sensitive individuals. The determinants and characteristics related to noise sensitivity are rather poorly known. The risk of health effects caused by noise can be hypothesized to be higher for noise sensitive individuals compared to those who are not noise sensitive. A cardiovascular disease may be an example of outcomes. The general aim of the present study was to investigate the association of noise sensitivity with specific somatic and psychological factors, including the genetic component of noise sensitivity, and the association of noise sensitivity with mortality. The study was based on the Finnish Twin Cohort of same-sex twin pairs born before 1958. In 1988 a questionnaire was sent to twin pairs discordant for hypertension. 1495 individuals (688 men, 807 women) aged 31 88 years replied, including 573 twin pairs. 218 of the subjects lived in the Helsinki Metropolitan Area. Self-reported noise sensitivity, lifetime noise exposure and hypertension were obtained from the questionnaire study in 1988 and other somatic and psychological factors from the questionnaire study in 1981 for the same individuals. In addition, noise map information (1988 1992) from the Helsinki Metropolitan Area and mortality follow-up 1989 2003 were used. To evaluate the stability and validity of noise sensitivity, a new questionnaire was sent in 2002 to a sample of the subjects who had replied to the 1988 questionnaire. Of all subjects who had answered the question on noise sensitivity, 38 % were noise sensitive. Noise sensitivity was independent of noise exposure levels indicated in noise maps. Subjects with high noise sensitivity reported more transportation noise exposure than subjects with low noise sensitivity. Noise sensitive subjects reported transportation noise exposure outside the environmental noise map areas almost twice as often as non-sensitive subjects. Noise sensitivity was associated with hypertension, emphysema, use of psychotropic drugs, smoking, stress and hostility, even when lifetime noise exposure was adjusted for. Monozygotic twin pairs were more similar with regards noise sensitivity than dizygotic twin pairs, and quantitative genetic modelling indicated significant familiality. The best fitting genetic model provided an estimate of heritability of 36 %. Follow-up of subjects in the case-control study showed that cardiovascular mortality was significantly increased among noise sensitive women, but not among men. For coronary heart mortality the interaction of noise sensitivity and lifetime noise exposure was statistically significant in women. In conclusion, noise sensitivity has both somatic and psychological components. It does aggregate in families and probably has a genetic component. Noise sensitivity may be a risk factor for cardiovascular mortality in women.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Baltic amber-bead necklaces or bracelets are commonly used for managing teething symptoms in infants. The effectiveness of these beads is claimed to be from succinic acid release (a compound with analgesic and anti-inflammatory properties), which is then absorbed through the skin. AIM: To investigate whether Baltic amber teething necklaces purchased in Australia contained succinic acid, and to quantify succinic acid release from the beads. METHODS: Infrared spectroscopy was used to confirm that the teething necklaces were made of Baltic amber. The amount of succinic acid contained within the beads was quantified, and succinic acid release from intact beads was measured in phosphate buffered saline (PBS) pH 5.5 or octanol to simulate aqueous or oily skin environments. RESULTS: Each necklace (33 beads in length) contained 19.17±4.89 mg of succinic acid (mean±se). Over a 6-month period, no succinic acid was detected in PBS, while 0.13±0.09 mg of succinic acid per necklace was released in octanol. Only one replicate of amber beads in octanol released succinic acid, and they had fragmented, with shards free-floating in the solvent. DISCUSSION: It is likely succinic acid was only detected because the beads were breaking down in octanol, which does not occur when worn around the neck of a child. Furthermore, the hydrophilic properties of succinic acid would not favour its absorption across hydrophobic layers of the skin and into the bloodstream. CONCLUSION: While the teething necklaces do contain small quantities of succinic acid, it is highly unlikely to be released from intact beads.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sonography is an important clinical tool in diagnosing appendicitis in children as it can obviate both exposure to potentially harmful ionising radiation from computed tomography scans and the need for unnecessary appendicectomies. This review examines the diagnostic accuracy of ultrasound in the identification of acute appendicitis, with a particular focus on the the utility of secondary sonographic signs as an adjunct or corollary to traditionally examined criteria. These secondary signs can be important in cases where the appendix cannot be identified with ultrasound and a more meaningful finding may be made by incorporating the presence or absence of secondary sonographic signs. There is evidence that integrating these secondary signs into the final ultrasound diagnosis can improve the utility of ultrasound in cases where appendicitis is expected, though there remains some conjecture about whether they play a more important role in negative or positive prediction in the absence of an identifiable appendix.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1916, the Jewish community of Boston established Beth Israel Hospital on Townsend Street in Roxbury to provide health care to immigrants in the area. Although accessible to everyone, the hospital provided Yiddish-speaking services for Eastern European Jewish immigrants and served kosher food, as well as conducted Jewish religious services. In 1928 the hospital entered into a teaching agreement with Harvard Medical School, Tufts University, and Simmons College. Shortly thereafter, the hospital moved to its current location in the Longwood area of Boston and expanded to a 220-bed operation. During 1935-1936, at the height of the Depression, Beth Israel spent 1.5 million dollars in free patient care and was only one of two local hospitals to offer health care to people on welfare. In 1996, Beth Israel Hospital merged with Deaconess Medical Center and became Beth Israel Deaconess Medical Center. This collection contains reports, pamphlets and hospital publications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within coronial investigations, pathologists are called upon to given evidence as to cause of death. This evidence is given great weight by the coroners; after all, scientific ‘truth’ is widely deemed to be far more reliable than legal ‘opinion’. The purpose of this paper is to examine the ontological and epistemological status of that evidence, from the perspectives of both the pathologists and the coroners. As part of an Australian Research Council Linkage Grant, interviews were conducted with seven pathologists and 10 coroners from within the Queensland coronial system. Contrary to expectations, and the work of philosophers of science, such as Feyerabend (1975), pathologists did not present their findings in terms of unequivocal facts or objective truths relating to causes of death. Rather, their evidence was largely presented as ‘educated opinion’ based upon ‘the weight of evidence’. It was actually the coroners who translated that opinion into ‘medical fact’ within the proceedings of their death investigations, arguably as a consequence of the administrative necessity to reach a clear-cut finding as to cause of death, and on the basis of their own understanding of the ontology of medical knowledge. These findings support Latour’s (2010) claim that law requires a fundamentally different epistemology to science, and that science is not entirely to blame for the extravagant truth-claims made on its behalf

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An overview of the human side of the wearable technology trend in the medical industry. Forecasted as the next wave of technological innovations, wearable and physically embedded medical devices to help manage patients’ health conditions are set to change the healthcare experience for both patients and healthcare providers. The idea here is to pay closer attention to how particular patients experience these devices, so they can be designed with empathy for specific patient needs to maintain optimum health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thyroid hormone (TH) plays an important role in maintaining a homeostasis in all the cells of our body. It also has significant cardiovascular effects, and abnormalities of its concentration can cause cardiovascular disease and even morbidity. Especially development of heart failure has been connected to low levels of thyroid hormone. A decrease in TH levels or TH-receptor binding adversely effects cardiac function. Although, this occurs in part through alterations in excitation-contraction and transport proteins, recent data from our laboratory indicate that TH also mediates changes in myocardial energy metabolism. Thyroid dysfunction may limit the heart s ability to shift substrate pathways and provide adequate energy supply during stress responses. Our goals of these studies were to determine substrate oxidation pattern in systemic and cardiac specific hypothyroidism at rest and at higher rates of oxygen demand. Additionally we investigated the TH mediated mechanisms in myocardial substrate selection and established the metabolic phenotype caused by a thyroid receptor dysfunction. We measured cardiac metabolism in an isolated heart model using 13Carbon isotopomer analyses with MR spectroscopy to determine function, oxygen consumption, fluxes and fractional contribution of acetyl-CoA to the citric acid cycle (CAC). Molecular pathways for changes in cardiac function and substrate shifts occurring during stress through thyroid receptor abnormalities were determined by protein analyses. Our results show that TH modifies substrate selection through nuclear-mediated and rapid posttranscriptional mechanisms. It modifies substrate selection differentially at rest and at higher rates of oxygen demand. Chronic TH deficiency depresses total CAC flux and selectively fatty acid flux, whereas acute TH supplementation decreases lactate oxidation. Insertion of a dominant negative thyroid receptor (Δ337T) alters metabolic phenotype and contractive efficiency in heart. The capability of the Δ337T heart to increase carbohydrate oxidation in response to stress seems to be limited. These studies provided a clearer understanding of the TH role in heart disease and shed light to identification of the molecular mechanisms that will facilitate in finding targets for heart failure prevention and treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a self-regularized pseudo-time marching strategy for ill-posed, nonlinear inverse problems involving recovery of system parameters given partial and noisy measurements of system response. While various regularized Newton methods are popularly employed to solve these problems, resulting solutions are known to sensitively depend upon the noise intensity in the data and on regularization parameters, an optimal choice for which remains a tricky issue. Through limited numerical experiments on a couple of parameter re-construction problems, one involving the identification of a truss bridge and the other related to imaging soft-tissue organs for early detection of cancer, we demonstrate the superior features of the pseudo-time marching schemes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast reconstruction is performed for 10-15 % of women operated on for breast cancer. A popular method is the TRAM (transverse rectus abdominis musculocutaneous) flap formed of the patient’s own abdominal tissue, a part of one of the rectus abdominis muscles and a transverse skin-subcutis area over it. The flap can be raised as a pedicled or a free flap. The pedicled TRAM flap, based on its nondominant pedicle superior epigastric artery (SEA), is rotated to the chest so that blood flow through SEA continues. The free TRAM flap, based on its dominant pedicle deep inferior epigastric artery (DIEA), is detached from the abdomen, transferred to the chest, and DIEA and vein are anastomosed to vessels on the chest. Cutaneous necrosis is seen in 5–60 % of pedicled TRAM flaps and in 0–15 % of free TRAM flaps. This study was the first one to show with blood flow measurements that the cutaneous blood flow is more generous in free than in pedicled TRAM flaps. After this study the free TRAM flap has exceeded the pedicled flap in popularity as a breast reconstruction method, although the free flap it is technically a more demanding procedure than the pedicled TRAM flap. In pedicled flaps, a decrease in cutaneous blood flow was observed when DIEA was ligated. It seems that SEA cannot provide sufficient blood flow on the first postoperative days. The postoperative cutaneous blood flow in free TRAM flaps was more stable than in pedicled flaps. Development of cutaneous necrosis of pedicled TRAM flaps could be predicted based on intraoperative laser Doppler flowmetry (LDF) measurements. The LDF value on the contralateral skin of the flap decreased to 43 ± 7 % of the initial value after ligation of the DIEA in flaps developing cutaneous necrosis during the next week. Endothelin-1 (ET-1) is a powerful vasoconstrictory peptide secreted by vascular endothelial cells. A correlation was found between plasma ET-1 concentrations and peripheral vasoconstriction developing during and after breast reconstructions with a pedicled TRAM flap. ET-1 was not associated with the development of cutaneous necrosis. Felodipine, a vasodilating calcium channel antagonist, had no effect on plasma ET-1 concentrations, peripheral vasoconstriction or development of cutaneous necrosis in free TRAM flaps. Body mass index and thickness of abdominal were not associated with cutaneous necrosis in pedicled TRAM flaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Technological development of fast multi-sectional, helical computed tomography (CT) scanners has allowed computed tomography perfusion (CTp) and angiography (CTA) in evaluating acute ischemic stroke. This study focuses on new multidetector computed tomography techniques, namely whole-brain and first-pass CT perfusion plus CTA of carotid arteries. Whole-brain CTp data is acquired during slow infusion of contrast material to achieve constant contrast concentration in the cerebral vasculature. From these data quantitative maps are constructed of perfused cerebral blood volume (pCBV). The probability curve of cerebral infarction as a function of normalized pCBV was determined in patients with acute ischemic stroke. Normalized pCBV, expressed as a percentage of contralateral normal brain pCBV, was determined in the infarction core and in regions just inside and outside the boundary between infarcted and noninfarcted brain. Corresponding probabilities of infarction were 0.99, 0.96, and 0.11, R² was 0.73, and differences in perfusion between core and inner and outer bands were highly significant. Thus a probability of infarction curve can help predict the likelihood of infarction as a function of percentage normalized pCBV. First-pass CT perfusion is based on continuous cine imaging over a selected brain area during a bolus injection of contrast. During its first passage, contrast material compartmentalizes in the intravascular space, resulting in transient tissue enhancement. Functional maps such as cerebral blood flow (CBF), and volume (CBV), and mean transit time (MTT) are then constructed. We compared the effects of three different iodine concentrations (300, 350, or 400 mg/mL) on peak enhancement of normal brain tissue and artery and vein, stratified by region-of-interest (ROI) location, in 102 patients within 3 hours of stroke onset. A monotonic increasing peak opacification was evident at all ROI locations, suggesting that CTp evaluation of patients with acute stroke is best performed with the highest available concentration of contrast agent. In another study we investigated whether lesion volumes on CBV, CBF, and MTT maps within 3 hours of stroke onset predict final infarct volume, and whether all these parameters are needed for triage to intravenous recombinant tissue plasminogen activator (IV-rtPA). The effect of IV-rtPA on the affected brain by measuring salvaged tissue volume in patients receiving IV-rtPA and in controls was investigated also. CBV lesion volume did not necessarily represent dead tissue. MTT lesion volume alone can serve to identify the upper size limit of the abnormally perfused brain, and those with IV-rtPA salvaged more brain than did controls. Carotid CTA was compared with carotid DSA in grading of stenosis in patients with stroke symptoms. In CTA, the grade of stenosis was determined by means of axial source and maximum intensity projection (MIP) images as well as a semiautomatic vessel analysis. CTA provides an adequate, less invasive alternative to conventional DSA, although tending to underestimate clinically relevant grades of stenosis.