813 resultados para Prótese peniana
Resumo:
OBJECTIVE: Long-term follow-up after endovascular aneurysm repair (EVAR) is very scarce, and doubt remains regarding the durability of these procedures. We designed a retrospective cohort study to assess long-term clinical outcome and morphologic changes in patients with abdominal aortic aneurysms (AAAs) treated by EVAR using the Excluder endoprosthesis (W. L. Gore and Associates, Flagstaff, Ariz). METHODS: From 2000 to 2007, 179 patients underwent EVAR in a tertiary institution. Clinical data were retrieved from a prospective database. All patients treated with the Excluder endoprosthesis were included. Computed tomography angiography (CTA) scans were retrospectively analyzed preoperatively, at 30 days, and at the last follow-up using dedicated tridimensional reconstruction software. For patients with complications, all remaining CTAs were also analyzed. The primary end point was clinical success. Secondary end points were freedom from reintervention, sac growth, types I and III endoleak, migration, conversion to open repair, and AAA-related death or rupture. Neck dilatation, renal function, and overall survival were also analyzed. RESULTS: Included were 144 patients (88.2% men; mean age, 71.6 years). Aneurysms were ruptured in 4.9%. American Society of Anesthesiologists classification was III/IV in 61.8%. No patients were lost during a median follow-up of 5.0 years (interquartile range, 3.1-6.4; maximum, 11.2 years). Two patients died of medical complications ≤ 30 days after EVAR. The estimated primary clinical success rates at 5 and 10 years were 63.5% and 41.1%, and secondary clinical success rates were 78.3% and 58.3%, respectively. Sac growth was observed in 37 of 142 patients (26.1%). Cox regression showed type I endoleak during follow-up (hazard ratio, 3.74; P = .008), original design model (hazard ratio, 3.85; P = .001), and preoperative neck diameter (1.27 per mm increase, P = .006) were determinants of sac growth. Secondary interventions were required in 32 patients (22.5%). The estimated 10-year rate of AAA-related death or rupture was 2.1%. Overall life expectancy after AAA repair was 6.8 years. CONCLUSIONS: EVAR using the Excluder endoprosthesis provides a safe and lasting treatment for AAA, despite the need for maintained surveillance and secondary interventions. At up to 11 years, the risk of AAA-related death or postimplantation rupture is remarkably low. The incidences of postimplantation sac growth and secondary intervention were greatly reduced after the introduction of the low-permeability design in 2004.
Resumo:
Os doentes com cardiopatias submetidos a intervenção cirúrgica com implantação de condutos entre o ventrículo direito e a artéria pulmonar (VD-AP) podem desenvolver estenose e/ou insuficiência pulmonares ao longo do tempo. Nestas situações, associadas a arritmias cardíacas, disfunção ventricular direita e morte súbita, a re-intervenção cirúrgica permanece um desafio pela complexidade, mortalidade e morbilidade significativas. A implantação percutânea de válvulas pulmonares (IPVP), recentemente desenvolvida, representa uma abordagem alternativa para estes doentes. Objectivo: Reportar a experiência inicial com a IPVP, analisando o seu impacto no manejo destes doentes. Material e Métodos: Avaliação prospectiva dos dados clínicos, ecocardiográficos, da ressonância magnética, hemodinâmicos e angiográficos dos doentes submetidos a IPVP. Resultados: Seis doentes em classe funcional igual ou superior a II com disfunção do conduto VD-AP foram submetidos a IPVP. Tinham todos evidência de insuficiência e 5/6 de estenose. O procedimento consistiu na implantação de stents não cobertos no conduto para reforçar a sua rigidez e prevenir fracturas dos stents valvulados pulmonares Melody ® (Medtronic), que foram em seguida implantados com sucesso em todos. Obteve-se uma redução da pressão ventricular direita (94±27 para 44±7mmHg), da relação entre a pressão ventricular direita e esquerda (94±27 para 44±7%), do gradiente do conduto (65±28 para 11±4mmHg) e ausência de regurgitação pulmonar. O procedimento teve uma duração mediana de 180 minutos e decorreu sem complicações major. Os doentes tiveram alta em mediana dois dias após o procedimento. Na última avaliação, em mediana 7,8 meses após o procedimento, os doentes encontramse em classe funcional I (5) ou II (1), sem evidência não invasiva de disfunção do conduto. Conclusões: Os nossos resultados acompanham a experiência actual com esta modalidade terapêutica, com excelentes resultados nestes grupo de doentes complexos. A implementação da IPVP em doentes com cardiopatia congénita que requerem re-intervenção no tracto de saída do ventrículo direito tem-se revelado uma técnica promissora, embora complexa, alternativa a mais uma intervenção cirúrgica.
Resumo:
Objectivo: Rever o perfil clínico e terapêutico dos doentes com malária grave admitidos numa unidade de cuidados intensivos (UCI). Tipo de estudo: Retrospectivo. População: Nove doentes com malária a Plasmodium falciparum admitidos entre Agosto de 1991 e Julho de 2001 na UCI do Hospital de Santo António dos Capuchos (HSAC). Resultados: As complicações mais frequentes foram as manifestações neurológicas, a síndroma de dificuldade respiratória aguda (SDRA) e a insuficiência renal aguda. A ventilação mecânica foi utilizada em cinco doentes, a prótese renal em dois e as aminas vasopressoras em três doentes. Faleceram dois doentes (22.2%). Conclusões: A malária a Plasmodium falciparum é uma doença potencialmente fatal, pelo que os factores de risco e os critérios para admissão em UCI devem ser identificados. A presença de disfunção de órgão, nomeadamente de manifestações neurológicas, insuficiência renal e respiratória deverão ser consideradas como indicação para internamento em cuidados intensivos.
Resumo:
Introdução: A artroplastia unicompartimental evoluiu nos últimos 40 anos, sendo hoje em dia considerada uma estratégia cirúrgica apropriada para a osteoartrose do compartimento interno da articulação do joelho. Desenvolvimentos nos instrumentos cirúrgicos, desenho do implante, abordagem cirúrgica e selecção dos doentes levaram a uma grande melhoria dos resultados pós-operatórios e aumento da longevidade das próteses unicompartimentais do joelho. Comparada com a prótese total, tem como vantagens a preservação óssea, menos complicações pós‐operatórias (perdas sanguíneas, dor pós‐operatória, taxa de infecção, trombose venosa profunda (TVP) e tromboembolismo pulmonar (TEP)), manutenção da normal cinemática do joelho, alta precoce e reabilitação mais rápida. A prótese unicompartimental Oxford phase 3 foi introduzida em 1998 e é uma prótese cimentada com menisco móvel de polietileno. Material e Métodos: Foi realizado um estudo retrospectivo das artroplastias unicompartimentais do joelho Oxford phase 3 realizadas no nosso serviço. Desde 2006 realizaram-se 37 artroplastias unicompartimentais (num total de 34 doentes). Sete dos quais não compareceram à avaliação pós-operatória e por isso foram excluídos do estudo. Todos os doentes incluídos no estudo foram avaliados clínica e radiograficamente. Foram revistos os processos de consulta e do internamento. Registou-se a idade,sexo, classificação ASA (American Society of Anesthesiologists), grau de satisfação, flexão‐extensão actual, Oxford knee score pré e pós‐operatório e alterações radiográficas a salientar. Resultados: O follow‐up médio foi de 47 meses (10 ‐ 83 meses). A idade média dos doentes é de 64 anos, com predomínio do sexo feminino. O ASA médio foi de 2,4. Um dos doentes foi submetido a conversão para artroplastia total do joelho por falência do componente tibial. Há 2 doentes não satisfeitos com a cirurgia (que corresponde aos doentes em que o Oxford knee score piorou). Há 1 doente pouco satisfeito e 23 satisfeitos ou muito satisfeitos. Todos os doentes conseguem fazer extensão completa e a média de flexão é 111º. A média do Oxford knee score pré‐operatório é de 17,4 (5 ‐ 30) e pós‐operatório é 36,6 (11 ‐ 48). Radiologicamente, há uma média de desvio em varo de 1,68º (varo 8º ‐ valgo 5º). Ocorreu artrose femoro‐tibial externa em três casos (dois dos quais também com artrose femoro‐patelar),um caso com slope tibial exagerado (19º), um caso com componente femoral em varo (15º), um caso com componente tibial demasiado grande com protusão interna, um caso de extrusão do menisco de polietileno, um caso com o componente tibial em valgo e um caso com falência deste (descelamento?) com provável necessidade de conversão para artroplastia total. Dos doentes não avaliados não há registo de conversão para artroplastia total do joelho ou outras complicações. Discussão: A larga maioria dos doentes encontram‐se satisfeitos ou muito satisfeitos, havendo uma melhoria do Oxford knee score para mais do dobro. Não se registaram complicações pós‐operatórias imediatas. Das artropastias unicompartimentas realizadas só uma foi convertida para artroplastia total e outra provavelmente a necessitar de conversão, com uma longevidade de 94,6% aos 47 meses (em média). Conclusão: A artroplastia unicompartimental do joelho demonstrou‐se uma excelente opção para doentes com osteoartrose não-inflamatória do compartimento interno do joelho. Para se obterem bons resultados os doentes devem ser criteriosamente seleccionados. Considerando a curva de aprendizagem necessária para o sucesso da cirurgia, a pouca experiência da maioria dos cirurgiões que colocaram as próteses não teve influência nos resultados finais, estando de acordo com a literatura existente, provando que a artroplastia unicompartimental do joelho tem bons resultados clínicos e funcionais. Um maior tempo de follow-up será necessário para se avaliar a longevidade das próteses unicompartimentais.
Resumo:
A Infecção do Local Cirúrgico (ILC) é referida em vários estudos como a mais importante causa de complicações pós-operatórias no utente cirúrgico. A realização de um maior número de cirurgias em ambulatório poderá dificultar o processo de monitorização da ILC, fazendo com que os serviços que não possuam um eficaz programa de vigilância destas infecções, tenham taxas de infecção sub-notificadas. Neste contexto, e durante a frequência do Curso de Especialidade em Enfermagem Médico-Cirúrgica, na Universidade Católica Portuguesa de Lisboa, realizou-se um estágio na Comissão de Controle de Infeção (CCI) do Hospital Santo António dos Capuchos, durante o qual foi desenvolvido um projecto com o objectivo de: “planear um sistema de monitorização da infecção do local cirúrgico após alta hospitalar em cirurgia de ambulatório”. Neste projecto a monitorização das ILC é realizada pelos enfermeiros da Unidade de Cirurgia de Ambulatório, com a colaboração de um cirurgião de referência. A monitorização inclui três fases, sendo que na primeira realiza-se uma colheita de dados no processo dos utentes e na segunda fase é feita uma avaliação/triagem de sinais e sintomas de ILC, através de um contacto telefónico com os utentes ao 7º e 30º dia de pós-operatório e ao 365º dia nas cirurgias em que tenha sido feita colocação de prótese. Na terceira fase faz-se uma análise e discussão dos dados. Sempre que se considerar necessário é feita observação direta do local cirúrgico. Para a recolha de dados foram construídas quatro grelhas com indicadores. No período de 10 de Novembro a 17 Dez de 2011 foram monitorizados 19 utentes, entre os quais 2 desenvolveram sinais e sintomas compatíveis com ILC, com necessidade de se iniciar antibioterapia. Tendo em conta os quatro princípios básicos da profilaxia de infecções do local cirúrgico e pelo confronto com a informação que foi possível aferir ao longo da elaboração do projecto, considerou-se fundamental discutir com a equipa algumas sugestões de melhoria nos cuidados prestados, bem como a discussão de medidas para a implementação de um efectivo “Programa de VE de ILC numa UCA”.
Resumo:
INTRODUCTION: Pregnant women with mechanical prosthetic heart valves are at increased risk for valve thrombosis. Management decisions for this life-threatening complication are complex. Open-heart surgery has a very high risk of maternal mortality and fetal loss. Bleeding and embolic risks associated with thrombolytic agents, the limited efficacy of thrombolysis in certain subgroups, and a lack of experience in the setting of pregnancy raise important concerns. CASE REPORT: We report a case of mitral prosthetic valve thrombosis in early pregnancy, which was successfully treated with streptokinase. Ten years later, the same patient had an uneventful pregnancy, throughout which acenocoumarol was maintained. CONCLUSION: With this case we review the prevention (with oral anticoagulant therapy) and treatment of prosthetic valve thrombosis during pregnancy, which is important for both obstetrician and cardiologist.
Resumo:
Apresenta-se aqui um estudo retrospectivo de 1340 admissões por intoxicação numa Unidade de Cuidados Intensivos Polivalente durante um período de quatro anos (1986-1989). Em 666 doentes ocorreram 735 intoxicações medicamentosas e em 674 doentes 691 intoxicações não medicamentosas. Nas
intoxicações medicamentosas destacam-se os fármacos com acção principal a nível do sistema nervoso central (82.3%), predominando os insecticidas organofosforados (5 1.2%) nas não medicamentosas. Ao longo dos anos considerados constatou-se uma diminuição absoluta e relativa do número de doentes
intoxicados (480 vs 244, 15.1% vs 9.9%). Dos internados, 698 era do sexo masculino (289 nas intoxicações medicamentosas e 409 nas não medicamentosas) e 642 do sexo feminino (377 nas medicamentosas e 265 nas não medicamentosas), existindo uma diferença estatisticamente muito significativa no tipo
de intoxicação quanto ao sexo (p
Resumo:
Introdução: O hematoma subdural agudo não traumático é uma entidade rara em Pediatria. A presença de sintomas neurológicos de instalação aguda associada a anti coagulação obriga à exclusão desta entidade. Caso clínico: Apresentamos o caso de uma criança, do sexo masculino, de sete anos de idade, com prótese mitral mecânica, medicada com varfarina, que recorreu ao serviço de urgência por cefaleias intensas e progressivas, associadas a alteração no estado de consciência e convulsões. A nível laboratorial o INR (International Normalized Ratio) era de 4,2. Foi admitida na Unidade de Cuidados Intensivos Pediátricos (UCIP) em coma com anisocoria. Iniciou ventilação mecânica, medidas anti-edema cerebral e antiepilépticos. O exame de imagem mostrou hematoma subdural agudo à esquerda, com desvio da linha média. Foi submetida a craniotomia descompressiva, 56 horas após o início da sintomatologia, com recuperação clínica e actualmente sem sequelas. Conclusão: Este caso clínico ilustra a importância da suspeição clínica de hematoma subdural em doentes anti coagulados, bem como a necessidade de optimização das condições cirúrgicas e da utilização das técnicas não invasivas na monitorização do nível de consciência.
Resumo:
Como parte integrante da Escola de Inverno do Curso Doutoral em Avaliação de Tecnologia, que decorreu no dia 13 de Dezembro de 2011, na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa, apresentou-se o Plano de Tese “Estudo Eletroencefalográfico em Crianças com Deficiência Auditiva Com e Sem Prótese”. O presente documento é o resultado da mesma apresentação onde salientamos as suas partes fundamentais. O sistema auditivo é um dos sistemas sensoriais mais interveniente no desenvolvimento cognitivo, psicológico, social e consequentemente relacional do indivíduo pelo que qualquer perturbação que o afete tem um enorme impacto a todos os níveis. Avaliar, diagnosticar e (re)abilitar auditivamente o indivíduo é a área profissional da doutoranda. Este estudo surge no contexto profissional mas também pessoal onde se pensa contribuir de forma efetiva na melhoria da qualidade de vida dos portadores de défice auditivo, desde a mais tenra idade. Este estudo irá utilizar o EEG como instrumento na avaliação da perceção auditiva. Para tal, serão avaliadas crianças com défice auditivo adaptadas proteticamente, seguidas na consulta de otorrinolaringologia pediátrica do Hospital Garcia de Orta. O EEG será realizado em dois passos – com e sem prótese auditiva – enquanto a criança é submetida a um estímulo sonoro.
Resumo:
Desenhado por Jacque Fresco, o Projecto Vénus é uma proposta de reconfiguração social, tendo como ferramenta de trabalho a cidade. A cidade projectada por Jacque Fresco responde de alguma forma a necessidade de encontrar programas de hibridização que ultrapassem os receios do determinismo em relação ao papel da tecnologia, e conferindo um cariz mais aproximado dos conceitos antropológicos de Leroi-Gourhan quando este apelida a técnica de utensílio colocado fora do corpo e que permitiu ao homem sobreviver num mundo hostil. A diferença é que a técnica já assumiu uma condição que transcende o mero instrumento, para ser já ela própria configuradora da realidade, como Kittler dizia em acerca dos media. Fresco coloca a cidade como paradigma de uma revolução cibernética, uma tecnotopia, em que a tecnologia servirá para libertar o humano de condições políticas, económicas e sociais que o autor considera obsoletas. Uma nova configuração multidimensional que se apoia numa nova esfera pública, ambicionando um ethos global com uma estrutura digital para comunicações em rede. Fresco atribui uma dimensão de extrema importância aos factos de a tecnologia, no Projecto Vénus, ficar paredes meias com a natureza sem que tenha uma relação intrusiva, mas antes uma relação de responsabilidade pela gestão eficaz dos sistemas circundantes que preconizam muitas das “expectativas messiânicas” de que Walter Benjamin nos falava acerca da tecnologia. O objectivo da presente dissertação será a partir da definição de técnica e da tecnologia e, mais tarde discutindo esta cidade cibernética chamada Projecto Vénus, tentar responder às seguintes perguntas: como Gourhan nos diz, a técnica foi colocada fora do corpo para permitir aos seres humanos sobreviver, podemos supor que, neste momento, com a emergência de novas áreas, como a biotecnologia, nanotecnologia e robótica, a tecnologia retorna ao corpo humano para resolver a falha que, de acordo com o mito de Epimeteu, lhe deu origem? Se assim for, este processo de incorporação dos aparelhos protéticos, pode significar que estamos a entrar na era de reprodutibilidade do corpo humano como um objecto? Além disso, será a crescente visibilidade do Projecto Vénus um sintoma de uma crescente sociedade tecnológica, uma tecnotopia cujo fim último é a reconfiguração da máquina antropológica tal como Agamben colocou em «The Open»?
Resumo:
Corpos pós-humanos: Mashup do homem e da máquina; Visão melhorada; Prótese para a e-beleza; Renascimento em capela sistina digital? Corpos culturais; Cyborgs; Donna Haraway; Pós-humano; Projeto 1: Digitalização do conhecimento; Os novos heróis da cena social e os novos vilões; Crítica pelo humor: humanidade aumentada? Máscara digital; E-sexualidades. Humano-Animal-Máquina: Corpo e sobrevivência; Corpo e estética: Projeto 2: Novas estéticas do corpo; Projeto 3: Corpos e poder; Corpo e identidade política; Lev Manovich: transcodificação; Cérebro como base de dados; Corpo desterritorializado; Transhumanismo; Elite de pós-humanos?
Resumo:
Tese de Doutoramento (Programa Doutoral em Engenharia Biomédica)
Resumo:
OBJETIVO: Avaliar os diferentes métodos de quantificação de insuficiência mitral (IM) ao ecocardiograma transesofágico (ETE) em pacientes com suspeita clínica de disfunção de prótese mitral. MÉTODOS: Foram estudados 15 pacientes, divididos em dois grupos, conforme a presença ou não de IM expressiva (grau importante) ao cateterismo cardíaco (Cate). A IM foi quantificada ao ETE pelos seguintes métodos, habitualmente empregados para IM de valvas nativas: avaliação subjetiva do jato regurgitante ao mapeamento de fluxo a cores, avaliação objetiva com base na área absoluta do jato regurgitante e na sua área relativa (área do jato/área do átrio esquerdo (AE)), e avaliação baseada na presença de fluxo sistólico reverso em veia pulmonar. RESULTADOS: A IM foi predominantemente de origem transprotética (14 pacientes) e de distribuição excêntrica (11 pacientes). Observou-se concordância estatisticamente significante (p<0,05) entre IM expressiva ao Cate (8 pacientes) e ao ETE pela avaliação subjetiva e presença de fluxo sistólico reverso em veia pulmonar. As avaliações pelas áreas absoluta (área de jato >7cm²) e relativa (área de jato >35% da área do AE) não mostraram concordância significante com o Cate, com nítida subestimação ao ETE pela área relativa. Houve, porém, concordância significante, quando considerado como IM expressiva, jato cuja área relativa foi >30% da área do AE. CONCLUSÃO: O ETE identificou adequadamente as IM protéticas angiograficamente expressivas, particularmente pelos métodos subjetivo e de fluxo sistólico reverso em veia pulmonar. É necessário cautela na utilização de critérios baseados na área do jato regurgitante, em virtude da subestimação da área na presença de jato excêntrico, freqüente em disfunção de prótese mitral.
Resumo:
OBJETIVO: Comparar, clinica e laboratorialmente, três grupos de pacientes submetidos ao tratamento cirúrgico da insuficiência mitral crônica isolada; um grupo submetido à plástica valvar e dois à troca da valva mitral com diferentes técnicas de preservação das cordas. MÉTODOS: Operados 28 pacientes com idade média de 54,1 anos, sem doença coronariana, multivalvar ou reoperações: 9 tiveram plástica valvar, 10 troca valvar mitral com preservação das cordas de ambas as cúspides, e 9 apenas da cúspide posterior. Avaliações clínicas, ecodopplercardiográfica e radioisotópica foram realizadas até o 6º mês de seguimento. RESULTADOS: Ao final, 88,8% encontravam-se em classe funcional I. Um faleceu por hemorragia intracraniana durante tratamento anticoagulante. Houve queda no diâmetro diastólico (p<0,0001) e volume diastólico final do ventrículo esquerdo (p<0,0001) nos três grupos. Apenas os pacientes submetidos à plástica tiveram queda no diâmetro sistólico (p=0,0003) e no volume sistólico final (p=0,0040), sem alterações na fração de ejeção (p=0,5586). Os submetidos à troca valvar mitral tiveram queda similar na fração de ejeção (p=0,0001 e p=0,0296). CONCLUSÃO: Houve melhora clínica com as três técnicas empregadas. Os pacientes submetidos à plástica valvar tiveram melhor preservação da função ventricular. Não houve diferença significativa no desempenho cardíaco entre os dois grupos submetidos à troca valvar mitral com preservação das cordas até o 6º mês de seguimento.
Resumo:
OBJETIVO: Avaliar a incidência de trombo intracardíaco e de tromboembolismo nos três primeiros meses após a troca valvar por bioprótese e identificar fatores de risco para a formação de trombo. MÉTODO:Incluídos 184 pacientes, entre 15 e 75 anos de idade, submetidos a implante de bioprótese e realizados ecocardiogramas transtorácico e transesofágico (ETE) na fase hospitalar, média 8,4±3 dias, e três meses após, média 97,4±21,7 dias. RESULTADOS: Incidência de trombo foi significativamente mais elevada nos pacientes com prótese em posição mitral ou mitroaórtica (21,0%) do que em posição aórtica (2,8%), p<0,001. A análise de regressão logística multivariada identificou a prótese em posição mitral ou mitroaórtica como a única variável independente para a formação de trombo. No seguimento de três meses o ETE evidenciou trombo em 35 (20,7%) dos 169 pacientes com evolução ecocardiográfica, 31,7% nos mitrais e 3,1% nos aórticos, p<0,001. No 3º mês a análise de regressão logística multivariada também identificou a prótese em posição mitral ou mitroaórtica como a única variável independente para a formação de trombo. Durante os três meses de seguimento, três (1,6%) pacientes faleceram e oito (4,3%) apresentaram fenômeno embólico, todos para território cerebral. CONCLUSÃO: A incidência de trombo nos três primeiros meses, após o implante da bioprótese foi 14,1% nos 10 primeiros dias e 20,7% em três meses; a prótese em posição mitral ou mitroaórtica foi identificada como fator de risco para a formação de trombo; a incidência de fenômenos embólicos diagnosticados clinicamente foi inferior à proporção de trombo atrial documentado pelo ecocardiograma.