940 resultados para Non-invasive method


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Annually hundreds of crab-eating foxes (Cerdocyon thous) are referred to rehabilitation centers and zoos in Brazil. The ultrasonographic study of wildlife species is an important tool for a non-invasive and accurate anatomical description and provides important information for wildlife veterinary care. The aim of the present study was to determine the characteristics of the main abdominal organs as well as the vascular indexes of the abdominal aorta and renal arteries of crab-eating foxes (Cerdocyon thous) using mode B ultrasonography and Doppler ultrasonography, respectively. Ultrasonographic features of the main abdominal organs were described and slight differences were noticed between ultrasound imaging of abdominal organs of crab-eating foxes and other species. The bladder presented wall thickness of 12 +/- 0.01 mm, with three defined layers. Both, the right and left kidneys presented corticomedullary ratio of 1: 1 and similarly to the adrenals and the liver, they were homogeneous and hypoechoic compared to the spleen. The spleen was homogeneous and hyperechoic compared to the kidneys. The stomach presented 3 to 5 peristaltic movements per minute, wall thickness of 39 +/- 0.05 mm and lumen and mucosa with hyperechoic and hypoechoic features, respectively. Small and large intestines presented 2 to 3 peristaltic movements per minute, wall thickness of 34 +/- 0.03 mm and three defined layers with hyperechogenic (submucosa and serosa) and hypoechogenic (muscular) features. Ovaries of the female crab-eating fox were hypoechoic compared to the spleen and with heterogeneous parenchyma due to the presence of 2x2 mm ovarian follicles. Prostates of the six males were regular and with a well defined boundary, with a homogeneous and hyperechoic parenchyma compared to the spleen. Vascular indexes of the abdominal aorta (PSV: 25.60 +/- 0.32 cm/s; EDV: 6.96 +/- 1.68cm/s; PI: 1.15 +/- 0.07 e RI: 0.73 +/- 0.07) and right (PSV: 23.08 +/- 3.34cm/s; EDV: 9.33 +/- 2.36cm/s; PI: 1.01 +/- 0.65 e RI: 0.65 +/- 0.16) and left renal arteries (PSV: 23.74 +/- 3.94cm/s; EDV: 9.07 +/- 3.02cm/s; PI: 1.04 +/- 0.31 e RI: 0.64 +/- 0.10) were determined. Thus, conventional and Doppler ultrasonographic imaging provides basic information that can be used as reference for the species as well for other wild canids and it is a precise and non-invasive method that can be safely used to evaluate and diagnose abdominal injuries in these patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sowohl in der Natur als auch in der Industrie existieren thermisch induzierte Strömungen. Von Interesse für diese Forschungsarbeit sind dabei die Konvektionen im Erdmantel sowie in den Glasschmelzwannen. Der dort stattfindende Materialtransport resultiert aus Unterschieden in der Dichte, der Temperatur und der chemischen Konzentration innerhalb des konvektierenden Materials. Um das Verständnis für die ablaufenden Prozesse zu verbessern, werden von zahlreichen Forschergruppen numerische Modellierungen durchgeführt. Die Verifikation der dafür verwendeten Algorithmen erfolgt meist über die Analyse von Laborexperimenten. Im Vordergrund dieser Forschungsarbeit steht die Entwicklung einer Methode zur Bestimmung der dreidimensionalen Temperaturverteilung für die Untersuchung von thermisch induzierten Strömungen in einem Versuchsbecken. Eine direkte Temperaturmessung im Inneren des Versuchsmaterials bzw. der Glasschmelze beeinflusst allerdings das Strömungsverhalten. Deshalb wird die geodynamisch störungsfrei arbeitende Impedanztomographie verwendet. Die Grundlage dieser Methode bildet der erweiterte Arrhenius-Zusammenhang zwischen Temperatur und spezifischer elektrischer Leitfähigkeit. Während der Laborexperimente wird ein zähflüssiges Polyethylenglykol-Wasser-Gemisch in einem Becken von unten her erhitzt. Die auf diese Weise generierten Strömungen stellen unter Berücksichtigung der Skalierung ein Analogon sowohl zu dem Erdmantel als auch zu den Schmelzwannen dar. Über mehrere Elektroden, die an den Beckenwänden installiert sind, erfolgen die geoelektrischen Messungen. Nach der sich anschließenden dreidimensionalen Inversion der elektrischen Widerstände liegt das Modell mit der Verteilung der spezifischen elektrischen Leitfähigkeit im Inneren des Versuchsbeckens vor. Diese wird mittels der erweiterten Arrhenius-Formel in eine Temperaturverteilung umgerechnet. Zum Nachweis der Eignung dieser Methode für die nichtinvasive Bestimmung der dreidimensionalen Temperaturverteilung wurden mittels mehrerer Thermoelemente an den Beckenwänden zusätzlich direkte Temperaturmessungen durchgeführt und die Werte miteinander verglichen. Im Wesentlichen sind die Innentemperaturen gut rekonstruierbar, wobei die erreichte Messgenauigkeit von der räumlichen und zeitlichen Auflösung der Gleichstromgeoelektrik abhängt.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study validated the accuracy of data from a self-reported questionnaire on smoking behaviour with the use of exhaled carbon monoxide (CO) level measurements in two groups of patients. Group 1 included patients referred to an oral medicine unit, whereas group 2 was recruited from the daily outpatient service. All patients filled in a standardized questionnaire regarding their current and former smoking habits. Additionally, exhaled CO levels were measured using a monitor. A total of 121 patients were included in group 1, and 116 patients were included in group 2. The mean value of exhaled CO was 7.6 ppm in the first group and 9.2 ppm in the second group. The mean CO values did not statistically significantly differ between the two groups. The two exhaled CO level measurements taken for each patient exhibited very good correlation (Spearman's coefficient of 0.9857). Smokers had a mean difference of exhaled CO values of 13.95 ppm (p < 0.001) compared to non-smokers adjusted for the first or second group. The consumption of one additional pack year resulted in an increase in CO values of 0.16 ppm (p = 0.003). The consumption of one additional cigarette per day elevated the CO measurements by 0.88 ppm (p < 0.001). Based on these results, the correlations between the self-reported smoking habits and exhaled CO values are robust and highly reproducible. CO monitors may offer a non-invasive method to objectively assess current smoking behaviour and to monitor tobacco use cessation attempts in the dental setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hall-effect thrusters (HETs) are compact electric propulsion devices with high specific impulse used for a variety of space propulsion applications. HET technology is well developed but the electron properties in the discharge are not completely understood, mainly due to the difficulty involved in performing accurate measurements in the discharge. Measurements of electron temperature and density have been performed using electrostatic probes, but presence of the probes can significantly disrupt thruster operation, and thus alter the electron temperature and density. While fast-probe studies have expanded understanding of HET discharges, a non-invasive method of measuring the electron temperature and density in the plasma is highly desirable. An alternative to electrostatic probes is a non-perturbing laser diagnostic technique that measures Thomson scattering from the plasma. Thomson scattering is the process by which photons are elastically scattered from the free electrons in a plasma. Since the electrons have thermal energy their motion causes a Doppler shift in the scattered photons that is proportional to their velocity. Like electrostatic probes, laser Thomson scattering (LTS) can be used to determine the temperature and density of free electrons in the plasma. Since Thomson scattering measures the electron velocity distribution function directly no assumptions of the plasma conditions are required, allowing accurate measurements in anisotropic and non-Maxwellian plasmas. LTS requires a complicated measurement apparatus, but has the potential to provide accurate, non-perturbing measurements of electron temperature and density in HET discharges. In order to assess the feasibility of LTS diagnostics on HETs non-invasive measurements of electron temperature and density in the near-field plume of a Hall thruster were performed using a custom built laser Thomson scattering diagnostic. Laser measurements were processed using a maximum likelihood estimation method and results were compared to conventional electrostatic double probe measurements performed at the same thruster conditions. Electron temperature was found to range from approximately 1 – 40 eV and density ranged from approximately 1.0 x 1017 m-3 to 1.3 x 1018 m-3 over discharge voltages from 250 to 450 V and mass flow rates of 40 to 80 SCCM using xenon propellant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND The diagnostic performance of biochemical scores and artificial neural network models for portal hypertension and cirrhosis is not well established. AIMS To assess diagnostic accuracy of six serum scores, artificial neural networks and liver stiffness measured by transient elastography, for diagnosing cirrhosis, clinically significant portal hypertension and oesophageal varices. METHODS 202 consecutive compensated patients requiring liver biopsy and hepatic venous pressure gradient measurement were included. Several serum tests (alone and combined into scores) and liver stiffness were measured. Artificial neural networks containing or not liver stiffness as input variable were also created. RESULTS The best non-invasive method for diagnosing cirrhosis, portal hypertension and oesophageal varices was liver stiffness (C-statistics=0.93, 0.94, and 0.90, respectively). Among serum tests/scores the best for diagnosing cirrhosis and portal hypertension and oesophageal varices were, respectively, Fibrosis-4, and Lok score. Artificial neural networks including liver stiffness had high diagnostic performance for cirrhosis, portal hypertension and oesophageal varices (accuracy>80%), but were not statistically superior to liver stiffness alone. CONCLUSIONS Liver stiffness was the best non-invasive method to assess the presence of cirrhosis, portal hypertension and oesophageal varices. The use of artificial neural networks integrating different non-invasive tests did not increase the diagnostic accuracy of liver stiffness alone.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Studies have shown that increased arterial stiffening can be an indication of cardiovascular diseases like hypertension. In clinical practice, this can be detected by measuring the blood pressure (BP) using a sphygmomanometer but it cannot be used for prolonged monitoring. It has been established that pulse wave velocity (PWV) is a direct measure of arterial stiffening but its usefulness is hampered by the absence of non-invasive techniques to estimate it. Pulse transit time (PTT) is a simple and non-invasive method derived from PWV. However, limited knowledge of PTT in children is found in the present literature. The aims of this study are to identify independent variables that confound PTT measure and describe PTT regression equations for healthy children. Therefore, PTT reference values are formulated for future pathological studies. Fifty-five Caucasian children (39 male) aged 8.4 +/- 2.3 yr (range 5-12 yr) were recruited. Predictive equations for PTT were obtained by multiple regressions with age, vascular path length, BP indexes and heart rate. These derived equations were compared in their PWV equivalent against two previously reported equations and significant agreement was obtained (p < 0.05). Findings herein also suggested that PTT can be useful as a continuous surrogate BP monitor in children.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Assessment of the extent of coral bleaching has become an important part of studies that aim to understand the condition of coral reefs. In this study a reference card that uses differences in coral colour was developed as an inexpensive, rapid and non-invasive method for the assessment of bleaching. The card uses a 6 point brightness/saturation scale within four colour hues to record changes in bleaching state. Changes on the scale of 2 units or more reflect a change in symbiont density and chlorophyll a content, and therefore the bleaching state of the coral. When used by non-specialist observers in the field (here on an intertidal reef flat), there was an inter-observer error of I colour score. This technique improves on existing subjective assessment of bleaching state by visual observation and offers the potential for rapid, wide-area assessment of changing coral condition.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Making decisions is fundamental to everything we do, yet it can be impaired in various disorders and conditions. While research into the neural basis of decision-making has flourished in recent years, many questions remain about how decisions are instantiated in the brain. Here we explored how primates make abstract decisions and decisions in social contexts, as well as one way to non-invasively modulate the brain circuits underlying decision-making. We used rhesus macaques as our model organism. First we probed numerical decision-making, a form of abstract decision-making. We demonstrated that monkeys are able to compare discrete ratios, choosing an array with a greater ratio of positive to negative stimuli, even when this array does not have a greater absolute number of positive stimuli. Monkeys’ performance in this task adhered to Weber’s law, indicating that monkeys—like humans—treat proportions as analog magnitudes. Next we showed that monkeys’ ordinal decisions are influenced by spatial associations; when trained to select the fourth stimulus from the bottom in a vertical array, they subsequently selected the fourth stimulus from the left—and not from the right—in a horizontal array. In other words, they begin enumerating from one side of space and not the other, mirroring the human tendency to associate numbers with space. These and other studies confirmed that monkeys’ numerical decision-making follows similar patterns to that of humans, making them a good model for investigations of the neurobiological basis of numerical decision-making.

We sought to develop a system for exploring the neuronal basis of the cognitive and behavioral effects observed following transcranial magnetic stimulation, a relatively new, non-invasive method of brain stimulation that may be used to treat clinical disorders. We completed a set of pilot studies applying offline low-frequency repetitive transcranial magnetic stimulation to the macaque posterior parietal cortex, which has been implicated in numerical processing, while subjects performed a numerical comparison and control color comparison task, and while electrophysiological activity was recorded from the stimulated region of cortex. We found tentative evidence in one paradigm that stimulation did selectively impair performance in the number task, causally implicating the posterior parietal cortex in numerical decisions. In another paradigm, however, we manipulated the subject’s reaching behavior but not her number or color comparison performance. We also found that stimulation produced variable changes in neuronal firing and local field potentials. Together these findings lay the groundwork for detailed investigations into how different parameters of transcranial magnetic stimulation can interact with cortical architecture to produce various cognitive and behavioral changes.

Finally, we explored how monkeys decide how to behave in competitive social interactions. In a zero-sum computer game in which two monkeys played as a shooter or a goalie during a hockey-like “penalty shot” scenario, we found that shooters developed complex movement trajectories so as to conceal their intentions from the goalies. Additionally, we found that neurons in the dorsolateral and dorsomedial prefrontal cortex played a role in generating this “deceptive” behavior. We conclude that these regions of prefrontal cortex form part of a circuit that guides decisions to make an individual less predictable to an opponent.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Measurement of joint kinematics can provide knowledge to help improve joint prosthesis design, as well as identify joint motion patterns that may lead to joint degeneration or injury. More investigation into how the hip translates in live human subjects during high amplitude motions is needed. This work presents a design of a non-invasive method using the registration between images from conventional Magnetic Resonance Imaging (MRI) and open MRI to calculate three dimensional hip joint kinematics. The method was tested on a single healthy subject in three different poses. MRI protocols for the conventional gantry, high-resolution MRI and the open gantry, lowresolution MRI were developed. The scan time for the low-resolution protocol was just under 6 minutes. High-resolution meshes and low resolution contours were derived from segmentation of the high-resolution and low-resolution images, respectively. Low-resolution contours described the poses as scanned, whereas the meshes described the bones’ geometries. The meshes and contours were registered to each other, and joint kinematics were calculated. The segmentation and registration were performed for both cortical and sub-cortical bone surfaces. A repeatability study was performed by comparing the kinematic results derived from three users’ segmentations of the sub-cortical bone surfaces from a low-resolution scan. The root mean squared error of all registrations was below 1.92mm. The maximum range between segmenters in translation magnitude was 0.95mm, and the maximum deviation from the average of all orientations was 1.27◦. This work demonstrated that this method for non-invasive measurement of hip kinematics is promising for measuring high-range-of-motion hip motions in vivo.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This Q and A style briefing paper provides an overview of the use of body mass index (BMI) for the measurement of obesity. BMI is a person’s weight in kilograms divided by the square of their height in metres. It is one of the most commonly used ways of estimating whether a person is overweight and hence more likely to experience health problems than someone with a healthy weight. It is used to measure population prevalence of overweight and obesity. It is also a relatively easy, cheap and non-invasive method for establishing weight status. However, BMI is only a proxy for body fatness. Factors such as fitness, ethnic origin and puberty can alter the relation between BMI and body fatness and must be taken into consideration. Other measurements such as waist circumference and skin thickness can be collected to indicate a person’s weight status or body fatness. None of these is as widely used as BMI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ce projet illustre cinq études, mettant l'emphase sur le développement d'une nouvelle approche diagnostique cardiovasculaire afin d'évaluer le niveau d’oxygène contenu dans le myocarde ainsi que sa fonction microvasculaire. En combinant une séquence de résonance magnétique cardiovasculaire (RMC) pouvant détecter le niveau d’oxygène (OS), des manœuvres respiratoires ainsi que des analyses de gaz artériels peuvent être utilisés comme procédure non invasive destinée à induire une réponse vasoactive afin d’évaluer la réserve d'oxygénation, une mesure clé de la fonction vasculaire. Le nombre de tests diagnostiques cardiaques prescrits ainsi que les interventions, sont en pleine expansion. L'imagerie et tests non invasifs sont souvent effectués avant l’utilisation de procédures invasives. L'imagerie cardiaque permet d’évaluer la présence ou absence de sténoses coronaires, un important facteur économique dans notre système de soins de santé. Les techniques d'imagerie non invasives fournissent de l’information précise afin d’identifier la présence et l’emplacement du déficit de perfusion chez les patients présentant des symptômes d'ischémie myocardique. Néanmoins, plusieurs techniques actuelles requièrent la nécessité de radiation, d’agents de contraste ou traceurs, sans oublier des protocoles de stress pharmacologiques ou physiques. L’imagerie RMC peut identifier une sténose coronaire significative sans radiation. De nouvelles tendances d’utilisation de RMC visent à développer des techniques diagnostiques qui ne requièrent aucun facteur de stress pharmacologiques ou d’agents de contraste. L'objectif principal de ce projet était de développer et tester une nouvelle technique diagnostique afin d’évaluer la fonction vasculaire coronarienne en utilisant l' OS-RMC, en combinaison avec des manœuvres respiratoires comme stimulus vasoactif. Ensuite, les objectifs, secondaires étaient d’utilisés l’OS-RMC pour évaluer l'oxygénation du myocarde et la réponse coronaire en présence de gaz artériels altérés. Suite aux manœuvres respiratoires la réponse vasculaire a été validée chez un modèle animal pour ensuite être utilisé chez deux volontaires sains et finalement dans une population de patients atteints de maladies cardiovasculaires. Chez le modèle animal, les manœuvres respiratoires ont pu induire un changement significatif, mesuré intrusivement par débit sanguin coronaire. Il a été démontré qu’en présence d'une sténose coronarienne hémodynamiquement significative, l’OS-RMC pouvait détecter un déficit en oxygène du myocarde. Chez l’homme sain, l'application de cette technique en comparaison avec l'adénosine (l’agent standard) pour induire une vasodilatation coronarienne et les manœuvres respiratoires ont pu induire une réponse plus significative en oxygénation dans un myocarde sain. Finalement, nous avons utilisé les manœuvres respiratoires parmi un groupe de patients atteint de maladies coronariennes. Leurs myocardes étant altérées par une sténose coronaire, en conséquence modifiant ainsi leur réponse en oxygénation. Par la suite nous avons évalué les effets des gaz artériels sanguins sur l'oxygénation du myocarde. Ils démontrent que la réponse coronarienne est atténuée au cours de l’hyperoxie, suite à un stimuli d’apnée. Ce phénomène provoque une réduction globale du débit sanguin coronaire et un déficit d'oxygénation dans le modèle animal ayant une sténose lorsqu’un supplément en oxygène est donné. En conclusion, ce travail a permis d'améliorer notre compréhension des nouvelles techniques diagnostiques en imagerie cardiovasculaire. Par ailleurs, nous avons démontré que la combinaison de manœuvres respiratoires et l’imagerie OS-RMC peut fournir une méthode non-invasive et rentable pour évaluer la fonction vasculaire coronarienne régionale et globale.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background and Objectives: The measurement of salivary immunoglobulin A is a useful and non-invasive method for measuring stress. Personality traits and rumination act as possible mediators in the relationship between psychological stressors and the immune system. This study was aimed to evaluate the levels of salivary IgA under psychological stress and its relationship with rumination and five personality traits in medical students. Methods: In this cross- sectional study, 45 medical students who intended to participate in the final exam were selected by simple random sampling. Two months before the exam, in the basal conditions, the NEO Personality Inventory-Short Form and Emotional Control Questionnaire (ECQ) were completed. Saliva samples were taken from students in both the basal conditions and exam stress conditions. Salivary IgA was measured by an ELISA test. Data was analyzed using paired samples T-test, Pearson correlation analysis, and stepwise regression. Results: A significant reduction of salivary IgA levels was found in exam stress conditions. Also, a significant negative correlation was found between traits of neuroticism and rumination with salivary IgA, as well as a significant positive correlation between of openness to experience and emotional inhibition with salivary IgA. Openness to experience and emotional inhibition may predict a substantial variance (34%) of salivary IgA under exam stress. Conclusions: Salivary IgA is reduced in response to exam stress. In addition, the rumination and personality traits may reduce or increase stress effects on the immune system, particularly the salivary IgA.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Hintergrund: Helicobacter pylori (H. pylori) zählt trotz abnehmender Inzidenz zu den häufigsten bakteriellen Infektionskrankheiten des Menschen. Die Infektion mit H. pylori ist ein Risikofaktor für Krankheiten wie gastroduodenale Geschwüre, Magenkarzinomen und MALT (Mucosa Associated Lymphoid Tissue)-Lymphomen. Zur Diagnostik von H. pylori stehen verschiedene invasive und nichtinvasive Verfahren zur Verfügung. Der 13C-Harnstoff-Atemtest wird zur Kontrolle einer Eradikationstherapie empfohlen, kommt in der Primärdiagnostik von H. pylori derzeit jedoch nicht standardmäßig in Deutschland zum Einsatz. Fragestellung: Welchen medizinischen und gesundheitsökonomischen Nutzen hat die Untersuchung auf H. pylori-Besiedlung mittels 13C-Harnstoff-Atemtest in der Primärdiagnostik im Vergleich zu invasiven und nichtinvasiven diagnostischen Verfahren? Methodik: Basierend auf einer systematischen Literaturrecherche in Verbindung mit einer Handsuche werden Studien zur Testgüte und Kosten-Effektivität des 13C-Harnstoff-Atemtests im Vergleich zu anderen diagnostischen Verfahren zum primären Nachweis von H. pylori identifiziert. Es werden nur medizinische Studien eingeschlossen, die den 13C-Harnstoff-Atemtest direkt mit anderen H. pylori-Testverfahren vergleichen. Goldstandard ist eines oder eine Kombination der biopsiebasierten Testverfahren. Für die gesundheitsökonomische Beurteilung werden nur vollständige gesundheitsökonomische Evaluationsstudien einbezogen, bei denen die Kosten-Effektivität des 13C Harnstoff-Atemtests direkt mit anderen H. pylori-Testverfahren verglichen wird. Ergebnisse: Es werden 30 medizinische Studien für den vorliegenden Bericht eingeschlossen. Im Vergleich zum Immunglobulin G (IgG)-Test ist die Sensitivität des 13C-Harnstoff-Atemtests zwölfmal höher, sechsmal niedriger und einmal gleich, und die Spezifität 13-mal höher, dreimal niedriger und zweimal gleich. Im Vergleich zum Stuhl-Antigen-Test ist die Sensitivität des 13C-Harnstoff-Atemtests neunmal höher, dreimal niedriger und einmal gleich, und die Spezifität neunmal höher, zweimal niedriger und zweimal gleich. Im Vergleich zum Urease-Schnelltest sind die Sensitivität des 13C-Harnstoff-Atemtests viermal höher, dreimal niedriger und viermal gleich und die Spezifität fünfmal höher, fünfmal niedriger und einmal gleich. Im Vergleich mit der Histologie ist die Sensitivität des 13C-Harnstoff-Atemtests einmal höher und zweimal niedriger und die Spezifität zweimal höher und einmal niedriger. In je einem Vergleich zeigt sich kein Unterschied zwischen 13C-Harnstoff-Atemtest und 14C-Harnstoff-Atemtest, sowie eine niedrigere Sensitivität und höhere Spezifität im Vergleich zur Polymerase-Kettenreaktion (PCR). Inwieweit die beschriebenen Unterschiede statistisch signifikant sind, wird in sechs der 30 Studien angegeben. Es werden neun gesundheitsökonomische Evaluationen in dem vorliegenden Bericht berücksichtigt. Die Test-and-Treat-Strategie mittels 13C-Harnstoff-Atemtest wird in sechs Studien mit einem Test-and-Treat-Verfahren auf Basis der Serologie sowie in drei Studien mit einem Test-and-Treat-Verfahren auf Basis des Stuhl-Antigen-Tests verglichen. Dabei ist das Atemtestverfahren dreimal kosteneffektiv gegenüber der serologischen Methode und wird von der Stuhl-Antigen-Test-Strategie einmal dominiert. Vier Studien beinhalten einen Vergleich der Test-and -Treat-Strategie auf Basis des 13C-Harnstoff-Atemtests mit einer empirischen antisekretorischen Therapie, wobei sich das Atemtesverfahren zweimal als kosteneffektive Prozedur erweist und zwei Studien einen Vergleich mit einer empirischen Eradikationstherapie. In fünf Studien wird das Test-and-Treat-Verfahren mittels 13C-Harnstoff-Atemtest einer endoskopiebasierten Strategie gegenübergestellt. Zweimal dominiert die Atemteststrategie die endoskopische Prozedur und einmal wird sie von dieser Strategie dominiert. Diskussion:Sowohl die medizinischen als auch die ökonomischen Studien weisen mehr oder minder gravierende Mängel auf und liefern heterogene Ergebnisse. So werden in der Mehrzahl der medizinischen Studien keine Angaben zur statistischen Signifikanz der berichteten Unterschiede zwischen den jeweiligen Testverfahren gemacht. Im direkten Vergleich weist der 13C-Harnstoff-Atemtest überwiegend eine höhere Testgüte als der IgG und der Stuhl-Antigen-Test auf. Aus den Vergleichen mit dem Urease-Schnelltest lassen sich keine Tendenzen bezüglich der Sensitivität ableiten, wohingegen die Spezifität des 13C-Harnstoff-Atemtests höher einzuschätzen ist. Für die Vergleiche des 13C-Harnstoff-Atemtest mit der Histologie, dem 14C-Harnstoff-Atemtest und der PCR liegen zu wenige Ergebnisse vor. In der eingeschlossenen ökonomischen Literatur deuten einige Studienergebnisse auf eine Kosten-Effektivität der Test-and-Treat-Strategie mittels 13C-Harnstoff-Atemtest gegenüber dem Test-and-Treat-Verfahren auf Basis der Serologie und der empirischen antiskretorischen Therapie hin. Um Tendenzen bezüglich der Kosten-Effektivität der Atemteststrategie gegenüber der Test-and-Treat-Strategie mittels Stuhl-Antigen-Test sowie der empirischen Eradikationstherapie abzuleiten, mangelt es an validen Ergebnissen bzw. ökonomischer Evidenz. Die Untersuchungsresultate hinsichtlich eines Vergleichs mit endoskopiebasierten Verfahren fallen diesbezüglich zu heterogen aus. Insgesamt kann keines der ökonomischen Modelle der Komplexität des Managements von Patienten mit dyspeptischen Beschwerden gänzlich gerecht werden. Schlussfolgerungen/Empfehlungen: Zusammenfassend ist festzuhalten, dass die Studienlage zur medizinischen und ökonomischen Beurteilung des 13C-Harnstoff-Atemtests im Vergleich zu anderen diagnostischen Methoden nicht ausreichend ist, um den Atemtest als primärdiagnostisches Standardverfahren im Rahmen einer Test-and-Treat-Strategie beim Management von Patienten mit dyspeptischen Beschwerden für die deutsche Versorgungslandschaft insbesondere vor dem Hintergrund der Leitlinien der Deutschen Gesellschaft für Verdauungs- und Stoffwechselkrankheiten (DGVS) anstelle einer endoskopiebasierten Methode zu empfehlen.