994 resultados para Nasal prostheses
Resumo:
Background There is renewed interest in the role played by specific counter-regulatory mechanisms to control the inflammatory host response, poorly investigated in human pathology. Here, we monitored the expression of two anti-inflammatory mediators, annexin 1 and galectin-1, and assessed their potential link to glucocorticoids' (GCs) effective control of nasal polyposis (NP).Methods Total patterns of mRNA and protein expression were analysed by quantitative real-time PCR (qPCR) and Western blotting analyses, whereas ultrastructural immunocytochemistry was used for spatial localization and quantification of each mediator, focusing on mast cells, eosinophils and epithelial cells.Results Up-regulation of the annexin 1 gene, and down-regulation of galectin-1 gene, was detected in polypoid tissue compared with nasal mucosa. Patient treatment with betamethasone augmented galectin-1 protein expression in polyps. At the cellular level, control mast cells and eosinophils displayed higher annexin 1 expression, whereas marked galectin-1 immunolabelling was detected in the granule matrix of mast cells. Cells of glandular duct epithelium also displayed expression of both annexin 1 and galectin-1, augmented after treatment.Conclusion Mast cells and epithelial cells appeared to be pivotal cell types involved in the expression of both annexin 1 and galectin-1. It is possible that annexin 1 and galectin-1 could be functionally associated with a specific mechanism in NP and that GC exert at least part of their beneficial effects on the airway mucosa by up-regulating, in a specific cell target fashion, these anti-inflammatory agonists.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Este artigo trata das grafias não convencionais da sílaba com coda nasal encontradas em textos escritos por jovens e adultos. Para a descrição desses dados de escrita, são consideradas duas complexidades: (i) a fonético-fonológica da sílaba, particularmente do elemento nasal em coda, e (ii) a da representação ortográfica da nasalidade em português. Sob o aspecto fonético, a coda corresponde a uma redução de energia, o que pode tornar os segmentos que preenchem essa posição da sílaba menos audíveis. Sob o aspecto fonológico, a coda pode ser vista como um constituinte não imediato da sílaba cujo preenchimento sofre restrições. Sob o aspecto ortográfico, são três as possibilidades de registro da nasalidade:
Resumo:
Objectives: The present study used strain gauge analysis to perform an in vitro evaluation of the effect of axial loading on 3 elements of implant-supported partial fixed prostheses, varying the type of prosthetic cylinder and the loading points. Material and methods: Three internal hexagon implants were linearly embedded in a polyurethane block. Microunit abutments were connected to the implants applying a torque of 20 Ncm, and prefabricated Co-Cr cylinders and plastic prosthetic cylinders were screwed onto the abutments, which received standard patterns cast in Co-Cr alloy (n=5). Four strain gauges (SG) were bonded onto the surface of the block tangentially to the implants, SG 01 mesially to implant 1, SG 02 and SG 03 mesially and distally to implant 2, respectively, and SG 04 distally to implant 3. Each metallic structure was screwed onto the abutments with a 10 Ncm torque and an axial load of 30 kg was applied at five predetermined points (A, B, C, D, E). The data obtained from the strain gauge analyses were analyzed statistically by RM ANOVA and Tukey's test, with a level of significance of p<0.05. Results: There was a significant difference for the loading point (p=0.0001), with point B generating the smallest microdeformation (239.49 mu epsilon) and point D the highest (442.77 mu epsilon). No significant difference was found for the cylinder type (p=0.748). Conclusions: It was concluded that the type of cylinder did not affect in the magnitude of microdeformation, but the axial loading location influenced this magnitude.
Resumo:
Purpose: To evaluate the flexural strength of two fixed dental prosthesis (FDP) designs simulating frameworks of adhesive fixed partial prostheses, reinforced or not by glass fiber.Materials and Methods: Forty specimens, made with composite resin, were divided into 4 groups according to the framework design and the presence of fiber reinforcement: A1 - occlusal support; A2: occlusal support + glass fiber; B1: occlusal and proximal supports; B2: occlusal and proximal supports + glass fiber. The specimens were subjected to the three-point bending test, and the data were submitted to two-way ANOVA and Tukey's test (5%).Results: Group A2 (97.9 +/- 38 N) was statistically significantly different from all other experimental groups, presenting a significantly lower mean flexural strength.Conclusion: The use of glass fibers did not improve the flexural strength of composite resin, and designs with occlusal and proximal supports presented better results than designs simulating only occlusal support.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this in vitro study was to quantify strain development during axial and nonaxial loading using strain gauge analysis for three-element implant-supported FPDs, varying the arrangement of implants: straight line (L) and offset (O). Materials and Methods: Three Morse taper implants arranged in a straight line and three implants arranged in an offset configuration were inserted into two polyurethane blocks. Microunit abutments were screwed onto the implants, applying a 20 Ncm torque. Plastic copings were screwed onto the abutments, which received standard wax patterns cast in Co-Cr alloy (n = 10). Four strain gauges were bonded onto the surface of each block tangential to the implants. The occlusal screws of the superstructure were tightened onto microunit abutments using 10 Ncm and then axial and nonaxial loading of 30 Kg was applied for 10 seconds on the center of each implant and at 1 and 2 mm from the implants, totaling nine load application points. The microdeformations determined at the nine points were recorded by four strain gauges, and the same procedure was performed for all of the frameworks. Three loadings were made per load application point. The magnitude of microstrain on each strain gauge was recorded in units of microstrain (mu). The data were analyzed statistically by two-way ANOVA and Tukey's test (p < 0.05). Results: The configuration factor was statistically significant (p= 0.0004), but the load factor (p= 0.2420) and the interaction between the two factors were not significant (p= 0.5494). Tukey's test revealed differences between axial offset (mu) (183.2 +/- 93.64) and axial straight line (285.3 +/- 61.04) and differences between nonaxial 1 mm offset (201.0 +/- 50.24) and nonaxial 1 mm straight line (315.8 +/- 59.28). Conclusion: There was evidence that offset placement is capable of reducing the strain around an implant. In addition, the type of loading, axial force or nonaxial, did not have an influence until 2 mm.
Avaliação da colonização nasal por Staphylococcus spp. resistenteà oxacilina em alunos de enfermagem
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Background: Air conditioning-induced rhinitis in allergic individuals is a common epidemiologic finding, but its physiopathology,is still controversial. The aim of this study was to describe and compare the effects of experimental air conditioning temperature changes on the nasal mucosa of individuals with persistent allergic rhinitis compared with a control group.Methods: A case-control challenge study was performed in a laboratory of thermal comfort with experimental twin challenge chambers set at a 12 C difference in temperature. A group of 32 patients with persistent allergic rhinitis and a group of 16 control subjects were exposed for 30 minutes, 3 times alternately in each chamber. Nasal symptom scores were recorded and nasal samples collected before, immediately after, and 24 and 48 hours after the challenge.Results: the rhinitis group showed a higher symptom score, epithelial shedding, percentage of eosinophils, total inflammatory cells, leukotriene C-4, eosinophil cationic protein, albumin, and tryptase levels compared with controls. There was also a significant increase in symptom score, total cells recovered, percentage of eosinophils, epithelial shedding, albumin, myeloperoxidase, and soluble intercellular adhesion molecule 1 in both groups compared with baseline levels.Conclusion: Sudden temperature changes led to a more pronounced inflammatory nasal response in the rhinitis group with the recruitment and activation of eosinophils.Clinical implications: Persistent allergic rhinitis is a risk factor for developing sudden temperature change-related rhinitis even in the absence of allergen exposure.
Resumo:
This investigation evaluated the effectiveness of an infection control protocol for cleansing and disinfecting removable dental prostheses. Sixty-four dentures were rubbed with sterile cotton swab immediately after they had been taken from patients' mouths. Samples were individually placed in the culture medium and immediately incubated at 37 +/- 2 degreesC. The dentures were scrubbed for 1 min with 4% chlorhexidine, rinsed for 1 min in sterile water and placed for 10 min in one of the following immersion solutions: 4% chlorhexidine gluconate, 1% sodium hypochlorite, Biocide (iodophors) and Amosan (alkaline peroxide). After the disinfection procedures, the dentures were immersed in sterile water for 3 min, reswabbed and the samples were incubated. All samples obtained in the initial culture were contaminated with micro-organisms. All the lower dentures immersed in Biocide showed positive growth, and the upper dentures were positive for growth in six of eight dentures. The 4% chlorhexidine gluconate, 1% sodium hypochlorite and Amosan solutions have been proved effective to reduce the growth of the micro-organisms in the 10 min immersion period. The protocol evaluated in this study seems to be a viable method to prevent cross-contamination between dental personnel and patients.
Resumo:
The orofacial characteristics of ectodermal dysplasia include anodontia or hypodontia, hypoplastic conical teeth, underdevelopment of the alveolar ridges, frontal bossing, a depressed nasal bridge, protuberant lips, and hypotrichosis. Patients with this disease often need complex prosthetic treatment. The options for a definitive treatment plan may include fixed, removable, or implant-supported prostheses, singly or in combination. However, financial constraints and other priorities can prevent patients from choosing the most desirable treatment. This clinical report describes the diagnosis and treatment of ectodermal dysplasia in an 18-year-old man. The treatment included interim removable partial dentures fabricated to establish an acceptable therapeutic occlusal vertical dimension, followed by definitive overlay removable partial dentures and composite restorations.