750 resultados para Intrasubject repeatability


Relevância:

10.00% 10.00%

Publicador:

Resumo:

ε-Caprolactam (CAP) is a monomer of nylon 6 used as food packaging for bologna sausage, turkey blanquettes, fowl breast, pâtés and ham luncheon meat. After polymerization a part of the monomer can remain in the packaging and migrate into the food. The aim of this work was develop and validate a single laboratory method to determine CAP in ethanol 95% that simulates fatty food characteristics. Thus, linear range was 2 to 32 mg/L of CAP, detection and quantification limits were 0.83 and 1.63 mg/L, respectively. Repeatability showed Hor Rat values lower than 2 while recovery range was 97.5 to 106.5%. The method was considered adequate for purpose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In honey 5-hydroxymethyl-2-furaldehyde (HMF) is one of the most typical products of degradation: it is usually absent in fresh honey, but its concentration tends to rise as a result of heating processes or long-term storage. The validation protocol was performed in terms of detection and quantification limits, precision (by repeatability and intermediate precision), linearity and accuracy (by recovery tests). The method has been tested on 15 honey samples of different ages and geographical origin. HMF correlated highly with the age of the samples has been considered a very important parameter to put these honeys on the market or not and/or to estimate their shelf life.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new electroanalytical method coupling TLC-DPV in solid state was developed for quantitative determination of phytoantioxidants with medicinal purpose, e.g. rosmarinic acid (RA) in samples of phytopharmaceuticals, e.g. rosemary (Rosmarinus officinalis L.). The method showed to be feasible, presenting linearity in concentrations ranging from 0.694 x 10-3 to 9.526 x 10-3 mol L-1 (r = 0.9945), good sensibility, selectivity, reproducibility, repeatability, agility and affordable cost. The concentrations of RA in different extracts of rosemary ranged from 0.05 to 0.52 (% w/w), presenting high recovery levels when compared to HPLC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We optimized a method for the determination of three main folate isoforms in leafy vegetables. Analysis was carried out by HPLC, using gradient of elution and fluorescence detection. Limits of quantification were 2 ng/mL; 2 ng/mL and 28 ng/mL for tetrahydrofolate (THF), 5-methyltetrahydrofolate (5-MTHF) and 5-formyltetrahydrofolate (5-FTHF), respectively. Recovery rates of THF, 5-MTHF and 5-FTHF varied from 87.86 to 100.64%; 88.12-94.22% and 89.82-106.69%, respectively. Test of repeatability showed relative standard deviation for peak areas lower than 10%. Tests for linearity showed high coefficients of determination. The results showed advances in folates extraction and analysis in raw and cooked leafy vegetables.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow injection on-line pre-concentration system coupled to thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) for cadmium determination at sub μg L-1 levels in seawater samples was developed. The on-line system was evaluated by analysing cadmium containing in a synthetic seawater matrix (2.5% m/v NaCl, 0.5% m/v MgCl2 and 0.8% m/v CaCl2). A sample volume of 2 mL allows determining Cd with a detection limits of 30 ng L-1 (3* σblank/slope), pre-concentration factor of 34 and repeatability of 1,8% (calculated as RSD, N=8 and containing 200 ng L-1 of Cd ).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Analysis of seven pesticides in sediments was successfully achieved using comprehensive two-dimensional gas chromatography with micro-electron capture detection, as it provided higher sensitivity and less matrix interference. Repeatability and intermediate precision of peak areas and heights were less than 4% and the recovery percentage for the analytes ranged from 52 to 115%. Instrumental LOD and LOQ were in the range of 0.60 to 2.31 μg L-1 and 1.83 to 5.62 μg L-1, respectively. Concentrations of 3.34 μg kg-1 (dry basis) for trifloxystrobin and azoxystrobin (below the LOQ) were found in a sediment sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method based on headspace - solid phase microextraction coupled with gas chromatography - mass spectrometry was validated for the quantitative determination of 18 organochlorine pesticides in water. For the extraction conditioning some parameters as the best type of coating fiber, time and temperature of extraction, pH and ionic strength were evaluated. The method HS-SPME/GC-MS/MS showed linear coefficient above 0.9948. The repeatability of the measurements were lower than 7.6%. Relative recoveries were between 88 and 110%. Limits of detection from 0.5 x 10-3 to 1.0 mg L-1 were obtained. A total of 31 samples were analyzed and 16 presented from 1 to 5 pesticides.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A RP-HPLC procedure for the simultaneous determination of cisplatin and the complex cis,cis,trans-diamminedichlorodihydroxo-platinum(IV), was development. The developed procedure was validated in terms of linearity, accuracy, precision, limits of detection (LOD), limits of quantification (LOQ) and specificity. The limits of detection (LOD) were 0.47 x 10-4 and 0.53 x 10-4 mol L-1 and the limits of quantification (LOQ) were 1.57 x 10-4 and 1.75 x 10-4 mol L-1, for cisplatin and cis,cis,trans-diamminedichlorodihydroxopla-tinum(IV), respectively. The average recoveries of cisplatin and cis,cis,trans-diamminedichlorodihydroxoplatinum(IV) was 100.6% ± 1.4 and 101.2% ± 1.1, respectively. Intermediate (inter-day) precision, repeatability and specificity of the procedure for hydrolysis products of cisplatin were studied. The results of the study showed that the proposed RP-HPLC procedure is simple, rapid, precise, accurate and specific.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method using LC/ESI-MS/MS for the quantitative analysis of Ochratoxin A in roasted coffee was described. Linearity was demonstrated (r = 0.9175). The limits of detection and quantification were 1.0 and 3.0 ng g-1, respectively. Trueness, repeatability and intermediate precision values were 89.0-108.8%; 2.4-13.7%; 12.5-17.8%, respectively. To the best of our knowledge, this is the first report in which Ochratoxin A in roasted coffee is analysed by LC/ESI-MS/MS, contributing to the field of mycotoxin analysis, and it will be used for future production of Certified Reference Material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ascorbic acid has important nutritional characteristics such as high antioxidant potential, preventing diverse damage and diseases in the tissues and the process of aging. Different isomeric forms of the ascorbic acid can be found in nature and each one have different potential antioxidant and different activity pro-vitamin C. This work examined a method to detect and quantify the isomers L-ascorbic acid (LAA) and D-iso-ascorbic acid (DIAA) in jelly fruit. The method showed acceptable selectivity, linearity, repeatability and recovery. DIAA was not found in the analyzed samples, but LAA was found up to 605 mg in 100 g of sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, the materials used in the recovery of estrogens from aqueous matrices by filtration and solid phase extraction were evaluated. The results showed that glass-fiber filters allow a recovery and repeatability compatible with this type of analysis, whereas cellulose esters lead to significant losses of the analytes, mainly due to adsorption processes. On the other hand, the transferring of the sample to the extraction cartridges should be carried out with glass or Teflon tubing, since the adsorption observed with other polymeric materials (eg. silicone, Tygon, polyethylene and PVC) dramatically reduces the recovery and repeatability of the extraction process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper regards the implementation of the QuEChERS method for the analysis by GC-FPD of 53 different pesticides from the organophosphate class, in whole UHT and pasteurized milk. Selectivity, linearity, repeatability, recovery and limits of detection and quantification were evaluated. Of all pesticide recoveries, 51 were considered satisfactory since the values ranged from 70 to 120% with RSD < 20%. The quantification limits ranged from 0.005 to 0.4 mg kg-1. The QuEChERS method was suitable for determination of 52 pesticides, presenting several advantages - quick, cheap, easy, effective, rugged and safe - with regard to other traditional methodologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The need for effective and reliable quality control in products from pharmaceutical industries renders the analyses of their active ingredients and constituents of great importance. This study presents the theoretical basis of ¹H NMR for quantitative analyses and an example of the method validation according to Resolution RE Nº 899 by the Brazilian National Health Surveillance Agency (ANVISA), in which the compound paracetamol was the active ingredient. All evaluated parameters (selectivity, linearity, accuracy, repeatability and robustness) showed satisfactory results. It was concluded that a single NMR measurement provides structural and quantitative information of active components and excipients in the sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple, precise, specific, repeatable and discriminating dissolution test for primaquine (PQ) matrix tablets was developed and validated according to ICH and FDA guidelines. Two UV assaying methods were validated for determination of PQ released in 0.1 M hydrochloric acid and water media. Both methods were linear (R²>0.999), precise (R.S.D.<1.87%) and accurate (97.65-99.97%). Dissolution efficiency (69-88%) and equivalence of formulations (f2) was assessed in different media and apparatuses (basket/100 rpm and paddle/50 rpm) tested. Discriminating condition was 900 mL aqueous medium, basket at 100 rpm and sampling times at 1, 4 and 8 h. Repeatability (R.S.D.<2.71%) and intermediate precision (R.S.D.<2.06%) of dissolution method were satisfactory.