932 resultados para Intellectual evaluation - WISC III


Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS: Although an added diagnostic and prognostic value of the global coronary artery calcification (CAC) score as an adjunct to single-photon emission computed tomography (SPECT)-myocardial perfusion image (MPI) has been repeatedly documented, none of the previous studies took advantage of the anatomic information provided by the unenhanced cardiac CT. Therefore, no co-registration has so far been used to match a myocardial perfusion defect with calcifications in the subtending coronary artery. To evaluate the prognostic value of integrating SPECT-MPI with CAC images were obtained from non-enhanced cardiac computed tomography (CT) for attenuation correction to predict major adverse cardiac events (MACE). METHODS AND RESULTS: Follow-up was obtained in 462 patients undergoing a 1-day stress/rest (99m)Tc-teterofosmin SPECT and non-enhanced cardiac CT for attenuation correction. Survival free of MACE was determined using the Kaplan-Meier method. After integrating MPI and CT findings, patients were divided into three groups (i) MPI defect matched by calcification (CAC ≥ 1) in the subtending coronary artery (ii) unmatched MPI and CT finding (iii) normal finding by MPI and CT. At a mean follow-up of 34.5 ± 13 months, a MACE was observed in 80 patients (33 death, 6 non-fatal myocardial infarction, 9 hospitalizations due to unstable angina, and 32 revascularizations). Survival analysis revealed the most unfavourable outcome (P < 0.001 log-rank test) for patients with a matched finding. CONCLUSION: In the present study, a novel approach using a combined integration of cardiac SPECT-CAC imaging allows for refined risk stratification, as a matched defect emerged as an independent predictor of MACE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: To investigate epidemiological, social, diagnostic and economic aspects of chlamydia screening in non-genitourinary medicine settings. METHODS: Linked studies around a cross-sectional population-based survey of adult men and women invited to collect urine and (for women) vulvovaginal swab specimens at home and mail these to a laboratory for testing for Chlamydia trachomatis. Specimens were used in laboratory evaluations of an amplified enzyme immunoassay (PCE EIA) and two nucleic acid amplification tests [Cobas polymerase chain reaction (PCR), Becton Dickinson strand displacement amplification (SDA)]. Chlamydia-positive cases and two negative controls completed a risk factor questionnaire. Chlamydia-positive cases were invited into a randomised controlled trial of partner notification strategies. Samples of individuals testing negative completed psychological questionnaires before and after screening. In-depth interviews were conducted at all stages of screening. Chlamydia transmission and cost-effectiveness of screening were investigated in a transmission dynamic model. SETTING AND PARTICIPANTS: General population in the Bristol and Birmingham areas of England. In total, 19,773 women and men aged 16-39 years were randomly selected from 27 general practice lists. RESULTS: Screening invitations reached 73% (14,382/19,773). Uptake (4731 participants), weighted for sampling, was 39.5% (95% CI 37.7, 40.8%) in women and 29.5% (95% CI 28.0, 31.0%) in men aged 16-39 years. Chlamydia prevalence (219 positive results) in 16-24 year olds was 6.2% (95% CI 4.9, 7.8%) in women and 5.3% (95% CI 4.4, 6.3%) in men. The case-control study did not identify any additional factors that would help target screening. Screening did not adversely affect anxiety, depression or self-esteem. Participants welcomed the convenience and privacy of home-sampling. The relative sensitivity of PCR on male urine specimens was 100% (95% CI 89.1, 100%). The combined relative sensitivities of PCR and SDA using female urine and vulvovaginal swabs were 91.8% (86.1, 95.7, 134/146) and 97.3% (93.1, 99.2%, 142/146). A total of 140 people (74% of eligible) participated in the randomised trial. Compared with referral to a genitourinary medicine clinic, partner notification by practice nurses resulted in 12.4% (95% CI -3.7, 28.6%) more patients with at least one partner treated and 22.0% (95% CI 6.1, 37.8%) more patients with all partners treated. The health service and patients costs (2005 prices) of home-based postal chlamydia screening were 21.47 pounds (95% CI 19.91 pounds, 25.99) per screening invitation and 28.56 pounds (95% CI 22.10 pounds, 30.43) per accepted offer. Preliminary modelling found an incremental cost-effectiveness ratio (2003 prices) comparing screening men and women annually to no screening in the base case of 27,000 pounds/major outcome averted at 8 years. If estimated screening uptake and pelvic inflammatory disease incidence were increased, the cost-effectiveness ratio fell to 3700 pounds/major outcome averted. CONCLUSIONS: Proactive screening for chlamydia in women and men using home-collected specimens was feasible and acceptable. Chlamydia prevalence rates in men and women in the general population are similar. Nucleic acid amplification tests can be used on first-catch urine specimens and vulvovaginal swabs. The administrative costs of proactive screening were similar to those for opportunistic screening. Using empirical estimates of screening uptake and incidence of complications, screening was not cost-effective.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objectives of this study were to develop and validate a tool for assessing pain in population-based observational studies and to develop three subscales for back/neck, upper extremity and lower extremity pain. Based on a literature review, items were extracted from validated questionnaires and reviewed by an expert panel. The initial questionnaire consisted of a pain manikin and 34 items relating to (i) intensity of pain in different body regions (7 items), (ii) pain during activities of daily living (18 items) and (iii) various pain modalities (9 items). Psychometric validation of the initial questionnaire was performed in a random sample of the German-speaking Swiss population. Analyses included tests for reliability, correlation analysis, principal components factor analysis, tests for internal consistency and validity. Overall, 16,634 of 23,763 eligible individuals participated (70%). Test-retest reliability coefficients ranged from 0.32 to 0.97, but only three coefficients were below 0.60. Subscales were constructed combining four items for each of the subscales. Item-total coefficients ranged from 0.76 to 0.86 and Cronbach's alpha were 0.75 or higher for all subscales. Correlation coefficients between subscales and three validated instruments (WOMAC, SPADI and Oswestry) ranged from 0.62 to 0.79. The final Pain Standard Evaluation Questionnaire (SEQ Pain) included 28 items and the pain manikin and accounted for the multidimensionality of pain by assessing pain location and intensity, pain during activity, triggers and time of onset of pain and frequency of pain medication. It was found to be reliable and valid for the assessment of pain in population-based observational studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The aim of this study was to investigate the biochemical properties, histological and immunohistochemical appearance, and magnetic resonance (MR) imaging findings of reparative cartilage after autologous chondrocyte implantation (ACI) for osteochondritis dissecans (OCD). METHODS: Six patients (mean age 20.2 +/- 8.8 years; 13-35 years) who underwent ACI for full-thickness cartilage defects of the femoral condyle were studied. One year after the procedure, a second-look arthroscopic operation was performed with biopsy of reparative tissue. The International Cartilage Repair Society (ICRS) visual histological assessment scale was used for histological assessment. Biopsied tissue was immunohistochemically analyzed with the use of monoclonal antihuman collagen type I and monoclonal antihuman collagen type II primary antibodies. Glycosaminoglycan (GAG) concentrations in biopsied reparative cartilage samples were measured by high performance liquid chromatography (HPLC). MR imaging was performed with T1- and T2-weighted imaging and three-dimensional spoiled gradient-recalled (3D-SPGR) MR imaging. RESULTS: Four tissue samples were graded as having a mixed morphology of hyaline and fibrocartilage while the other two were graded as fibrocartilage. Average ICRS scores for each criterion were (I) 1.0 +/- 1.5; (II) 1.7 +/- 0.5; (III) 0.6 +/- 1.0; (IV) 3.0 +/- 0.0; (V) 1.8 +/- 1.5; and (VI) 2.5 +/- 1.2. Average total score was 10.7 +/- 2.8. On immunohistochemical analysis, the matrix from deep and middle layers of reparative cartilage stained positive for type II collagen; however, the surface layer did not stain well. The average GAG concentration in reparative cartilage was 76.6 +/- 4.2 microg/mg whereas that in normal cartilage was 108 +/- 11.2 microg/mg. Common complications observed on 3D-SPGR MR imaging were hypertrophy of grafted periosteum, edema-like signal in bone marrow, and incomplete repair of subchondral bone at the surgical site. Clinically, patients had significant improvements in Lysholm scores. CONCLUSIONS: In spite of a good clinical course, reparative cartilage after ACI had less GAG concentration and was inferior to healthy hyaline cartilage in histological and immunohistochemical appearance and on MRI findings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND While the assessment of analytical precision within medical laboratories has received much attention in scientific enquiry, the degree of as well as the sources causing variation between them remains incompletely understood. In this study, we quantified the variance components when performing coagulation tests with identical analytical platforms in different laboratories and computed intraclass correlations coefficients (ICC) for each coagulation test. METHODS Data from eight laboratories measuring fibrinogen twice in twenty healthy subjects with one out of 3 different platforms and single measurements of prothrombin time (PT), and coagulation factors II, V, VII, VIII, IX, X, XI and XIII were analysed. By platform, the variance components of (i) the subjects, (ii) the laboratory and the technician and (iii) the total variance were obtained for fibrinogen as well as (i) and (iii) for the remaining factors using ANOVA. RESULTS The variability for fibrinogen measurements within a laboratory ranged from 0.02 to 0.04, the variability between laboratories ranged from 0.006 to 0.097. The ICC for fibrinogen ranged from 0.37 to 0.66 and from 0.19 to 0.80 for PT between the platforms. For the remaining factors the ICC's ranged from 0.04 (FII) to 0.93 (FVIII). CONCLUSIONS Variance components that could be attributed to technicians or laboratory procedures were substantial, led to disappointingly low intraclass correlation coefficients for several factors and were pronounced for some of the platforms. Our findings call for sustained efforts to raise the level of standardization of structures and procedures involved in the quantification of coagulation factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rehabilitation robots have become important tools in stroke rehabilitation. Compared to manual arm training, robot-supported training can be more intensive, of longer duration and more repetitive. Therefore, robots have the potential to improve the rehabilitation process in stroke patients. Whereas a majority of previous work in upper limb rehabilitation robotics has focused on end-effector-based robots, a shift towards exoskeleton robots is taking place because they offer a better guidance of the human arm, especially for movements with a large range of motion. However, the implementation of an exoskeleton device introduces the challenge of reproducing the motion of the human shoulder, which is one of the most complex joints of the body. Thus, this paper starts with describing a simplified model of the human shoulder. On the basis of that model, a new ergonomic shoulder actuation principle that provides motion of the humerus head is proposed, and its implementation in the ARMin III arm therapy robot is described. The focus lies on the mechanics and actuation principle. The ARMin III robot provides three actuated degrees of freedom for the shoulder and one for the elbow joint. An additional module provides actuated lower arm pro/supination and wrist flexion/extension. Five ARMin III devices have been manufactured and they are currently undergoing clinical evaluation in hospitals in Switzerland and in the United States.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Given that an alarming 1 in 5 children in the USA are at risk of hunger (1 in 3 among black and Latino children), and that 3.9 million households with children are food insecure, it is crucial to understand how household food insecurity (HFI) affects the present and future well-being of our children. Purpose: The objectives of this review article are to: (i) examine the association between HFI and child intellectual, behavioral and psycho-emotional development, controlling for socio-economic indicators; (ii) review the hypothesis that HFI is indeed a mediator of the relationship between poverty and poor child development outcomes; (iii) examine if the potential impact of HFI on caregivers’ mental health well-being mediates the relationship between HFI and child development outcomes. Methods: Pubmed search using the key words “food insecurity children.” For articles to be included they had to: (i) be based on studies measuring HFI using an experience-based scale, (ii) be peer reviewed, and (iii) include child intellectual, behavioral and/or socio-emotional development outcomes. Studies were also selected based on backward and forward Pubmed searches, and from the authors’ files. After reviewing the abstracts based on inclusion criteria a total of 26 studies were selected. Results: HFI represents not only a biological but also a psycho-emotional and developmental challenge to children exposed to it. Children exposed to HFI are more likely to internalize or externalize problems, as compared to children not exposed to HFI. This in turn is likely to translate into poor academic/cognitive performance and intellectual achievement later on in life. A pathway through which HFI may affect child development is possibly mediated by caregivers’ mental health status, especially parental stress and depression. Thus, HFI is likely to foster dysfunctional family environments. Conclusion: Findings indicate that food insecure households may require continued food assistance and psycho-emotional support until they transition to a “stable” food secure situation. This approach will require a much better integration of social policies and access to programs offering food assistance and mental health services to those in need. Findings also fully justify increased access of vulnerable children to programs that promote early in life improved nutrition as well as early psycho-social and cognitive stimulation opportunities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although the major metabolic pathways of cyclophosphamide are well established, the mechanism of antitumor drug selectivity is highly controversial. However, it is widely accepted that aldophosphamide, one of the primary metabolites, plays a crucial role in drug selectivity. In an attempt to gain a better understanding of the mechanism of selectivity of cyclophosphamide, a series of aldophosphamide analogs have been synthesized.^ The new analogs, unlike aldophosphamide, are relatively stable in neutral solution; however, they are converted rapidly to aldehydo intermediates in the presence of carboxylate esterase. Due to structural differences, these analogs may be classified into three different groups, arbitrarily designated as A, B, C, depending upon the facility with which the intermediate aldehydes form 4-hydroxy cyclic tautomers. The half-life of the aldehydo/4-hydroxy cyclic tautomeric mixture is longer for bis(acetoxy)aldophosphamide acetal I (a representative of group A), shorter for the n-ethyl analog III (B), and shortest for the N,N-dimethyl analog IV (C). The ratio of aldophosphamide: 4-hydroxycyclophosphamide at pseudoequilibrium is 1: 4 for compound I, 1: 2 for compound III and 0: 1 for compound IV. The therapeutic efficacy of these compounds are group A $>$ group B $>$ group C. It is apparent that the equilibrium position between the aldehydo and 4-hydroxy cyclic tautomers, which determines their stability, is a crucial determinant of both the cytotoxicity and antitumor selectivity. These findings, taken in conjunction with the aldehyde dehydrogenase selectivity hypothesis, may provide an explanation for the unique antitumor activity of cyclophosphamide. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Aortic dissection is a severe pathological condition in which blood penetrates between layers of the aortic wall and creates a duplicate channel - the false lumen. This considerable change on the aortic morphology alters hemodynamic features dramatically and, in the case of rupture, induces markedly high rates of morbidity and mortality. METHODS In this study, we establish a patient-specific computational model and simulate the pulsatile blood flow within the dissected aorta. The k-ω SST turbulence model is employed to represent the flow and finite volume method is applied for numerical solutions. Our emphasis is on flow exchange between true and false lumen during the cardiac cycle and on quantifying the flow across specific passages. Loading distributions including pressure and wall shear stress have also been investigated and results of direct simulations are compared with solutions employing appropriate turbulence models. RESULTS Our results indicate that (i) high velocities occur at the periphery of the entries; (ii) for the case studied, approximately 40% of the blood flow passes the false lumen during a heartbeat cycle; (iii) higher pressures are found at the outer wall of the dissection, which may induce further dilation of the pseudo-lumen; (iv) highest wall shear stresses occur around the entries, perhaps indicating the vulnerability of this region to further splitting; and (v) laminar simulations with adequately fine mesh resolutions, especially refined near the walls, can capture similar flow patterns to the (coarser mesh) turbulent results, although the absolute magnitudes computed are in general smaller. CONCLUSIONS The patient-specific model of aortic dissection provides detailed flow information of blood transport within the true and false lumen and quantifies the loading distributions over the aorta and dissection walls. This contributes to evaluating potential thrombotic behavior in the false lumen and is pivotal in guiding endovascular intervention. Moreover, as a computational study, mesh requirements to successfully evaluate the hemodynamic parameters have been proposed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The performance of high-resolution CZE for determination of carbohydrate-deficient transferrin (CDT) in human serum based on internal and external quality data gathered over a 10-year period is reported. The assay comprises mixing of serum with a Fe(III) ion-containing solution prior to analysis of the iron saturated mixture in a dynamically double-coated capillary using a commercial buffer at alkaline pH. CDT values obtained with a human serum of a healthy individual and commercial quality control sera are shown to vary less than 10%. Values of a control from a specific lot were found to slowly decrease as function of time (less than 10% per year). Furthermore, due to unknown reasons, gradual changes in the monitored pattern around pentasialo-transferrin were detected, which limit the use of commercial control sera of the same lot to less than 2 years. Analysis of external quality control sera revealed correct classification of the samples over the entire 10-year period. Data obtained compare well with those of HPLC and CZE assays of other laboratories. The data gathered over a 10-year period demonstrate the robustness of the high-resolution CZE assay. This is the first account of a CZE-based CDT assay with complete internal and external quality assessment over an extended time period.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To compare isoflurane alone or in combination with systemic ketamine and lidocaine for general anaesthesia in horses. STUDY DESIGN Prospective, randomized, blinded clinical trial. ANIMALS Forty horses (ASA I-III) undergoing elective surgery. METHODS Horses were assigned to receive isoflurane anaesthesia alone (ISO) or with ketamine and lidocaine (LKI). After receiving romifidine, diazepam, and ketamine, the isoflurane end-tidal concentration was set at 1.3% and subsequently adjusted by the anaesthetist (unaware of treatments) to maintain a light plane of surgical anaesthesia. Animals in the LKI group received lidocaine (1.5 mg kg(-1) over 10 minutes, followed by 40 microg kg(-1) minute(-1)) and ketamine (60 microg kg(-1) minute(-1)), both reduced to 65% of the initial dose after 50 minutes, and stopped 15 minutes before the end of anaesthesia. Standard clinical cardiovascular and respiratory parameters were monitored. Recovery quality was scored from one (very good) to five (very poor). Differences between ISO and LKI groups were analysed with a two-sample t-test for parametric data or a Fischer's exact test for proportions (p < 0.05 for significance). Results are mean +/- SD. RESULTS Heart rate was lower (p = 0.001) for LKI (29 +/- 4) than for ISO (34 +/- 6). End-tidal concentrations of isoflurane (ISO: 1.57% +/- 0.22; LKI: 0.97% +/- 0.33), the number of horses requiring thiopental (ISO: 10; LKI: 2) or dobutamine (ISO:8; LKI:3), and dobutamine infusion rates (ISO:0.26 +/- 0.09; LKI:0.18 +/- 0.06 microg kg(-1) minute(-1)) were significantly lower in LKI compared to the ISO group (p < 0.001). No other significant differences were found, including recovery scores. CONCLUSIONS AND CLINICAL RELEVANCE These results support the use of lidocaine and ketamine to improve anaesthetic and cardiovascular stability during isoflurane anaesthesia lasting up to 2 hours in mechanically ventilated horses, with comparable quality of recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A descriptive study of the current educational programs of selected health personnel in Nigeria was made in 1986. Data on the content of educational programs was obtained from personal communication with the Heads of the various institutions and from their published materials (catalogs, course outlines and program descriptions). Adequacy of these programs was judged in the light of current health problems and needs of the population. Evaluation was based on the following criteria: (a) Selection of students to maximize their usefulness in the provision of health care. (b) Relevance of the curriculum to the tasks the trainee will be called upon to perform. (c) Types of courses that focus on community health needs. Using official reports, the health situation in the country was described to give a relative priority of health services.^ Findings indicate the following: (1) Health conditions in Nigeria are related to a high prevalence of illness and disease, unsanitary living conditions, a high ratio of infant mortality and a shortage of public health services. Priority needs for improvement call for attitudinal and environmental changes. (2) All health training programs have improved the relevance of education to community health needs by strengthening practical field experience, and teaching those courses which focus on disease prevention. (3) Prospective nurses and community health workers are selected on the basis of a number of personal and intellectual characteristics, but academic performance alone is the criterion for medical students. (4) The curriculum in the medical school needs to be restructured to cut back on time devoted to enriching the medical "background". Basic sciences need better integration with hospital work. (5) Managerial and organization courses have been well incorporated into the nursing and community health workers' curricula. (6) There is a marked overlap in the tasks the community health workers are expected to perform. This causes some redundancy in having four separate categories of these health personnel. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents some of the results of a method to determine the main reliability functions of concentrator solar cells. High concentrator GaAs single junction solar cells have been tested in an Accelerated Life Test. The method can be directly applied to multi-junction solar cells. The main conclusions of this test carried out show that these solar cells are robust devices with a very low probability of failure caused by degradation during their operation life (more than 30 years). The evaluation of the probability operation function (i.e. the reliability function R(t)) is obtained for two nominal operation conditions of these cells, namely simulated concentration ratios of 700 and 1050 suns. Preliminary determination of the Mean Time to Failure indicates a value much higher than the intended operation life time of the concentrator cells.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Among the different optical modulator technologies available such as polymer, III-V semiconductors, Silicon, the well-known Lithium Niobate (LN) offers the best trade-off in terms of performances, ease of use, and power handling capability [1-9]. The LN technology is still widely deployed within the current high data rate fibre optic communications networks. This technology is also the most mature and guarantees the reliability which is required for space applications [9].In or der to fulfil the target specifications of opto-microwave payloads, an optimization of the design of a Mach-Zehnder (MZ) modulator working at the 1500nm telecom wavelength was performed in the frame of the ESA-ARTES "Multi GigaHertz Optical Modulator" (MGOM) project in order to reach ultra-low optical insertion loss and low effective driving voltage in the Ka band. The selected modulator configuration was the X-cut crystal orientation, associated to high stability Titanium in-diffusion process for the optical waveguide. Starting from an initial modulator configuration exhibiting 9 V drive voltage @ 30 GHz, a complete redesign of the coplanar microwave electrodes was carried out in order to reach a 6 V drive voltage @ 30GHz version. This redesign was associated to an optimization of the interaction between the optical waveguide and the electrodes. Following the optimisation steps, an evaluation program was applied on a lot of 8 identical modulators. A full characterisation was carried out to compare performances, showing small variations between the initial and final functional characteristics. In parallel, two similar modulators were submitted to both gamma (10-100 krad) and proton irradiation (10.109 p/cm²) with minor performance degradation.