971 resultados para Implicit difference method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A fourth-order numerical method for solving the Navier-Stokes equations in streamfunction/vorticity formulation on a two-dimensional non-uniform orthogonal grid has been tested on the fluid flow in a constricted symmetric channel. The family of grids is generated algebraically using a conformal transformation followed by a non-uniform stretching of the mesh cells in which the shape of the channel boundary can vary from a smooth constriction to one which one possesses a very sharp but smooth corner. The generality of the grids allows the use of long channels upstream and downstream as well as having a refined grid near the sharp corner. Derivatives in the governing equations are replaced by fourth-order central differences and the vorticity is eliminated, either before or after the discretization, to form a wide difference molecule for the streamfunction. Extra boundary conditions, necessary for wide-molecule methods, are supplied by a procedure proposed by Henshaw et al. The ensuing set of non-linear equations is solved using Newton iteration. Results have been obtained for Reynolds numbers up to 250 for three constrictions, the first being smooth, the second having a moderately sharp corner and the third with a very sharp corner. Estimates of the error incurred show that the results are very accurate and substantially better than those of the corresponding second-order method. The observed order of the method has been shown to be close to four, demonstrating that the method is genuinely fourth-order. © 1977 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the influence of cavity design and photocuring method on the marginal seal of resin composite restorations. METHOD AND MATERIALS: Seventy-two bovine teeth were divided into 2 groups: group 1 received box-type cavity preparations, and group 2 received plate-type preparations. Each group was divided into 3 subgroups. After etching and bonding, Z250 resin composite (3M Espe) was applied in 2 equal increments and cured with 1 of 3 techniques: (1) conventional curing for 30 seconds at 650 mW/cm2; (2) 2-step photocuring, in which the first step was performed 14 mm from the restoration for 10 seconds at 180 mW/cm2 and the second step was performed in direct contact for 20 seconds at 650 mW/cm2; or (3) progressive curing using Jetlite 4000 (J. Morita) for 8 seconds at 125 mW/cm2 and then 22 seconds at 125 mW/cm2 up to 500 mW/cm2. The specimens were thermocycled for 500 cycles and then submitted to dye penetration with a 50% silver nitrate solution. Microleakage was assessed using a stereomicroscope. Data were analyzed using analysis of variance and Tukey test (5% level of significance). RESULTS: A statistically significant difference was found between groups when a double interaction between photocuring and cavity preparation was considered (P = .029). CONCLUSIONS: No one type of cavity preparation or photocuring method prevented micro-leakage. The plate-type preparation showed the worst dye penetration when conventional and progressive photocuring methods were used. The best results were found using the 2-step photocuring with the plate-type preparation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this paper is to present a simple method for determining the high frequency parameters of a three-phase induction motor to be used in studies involving variable speed drives with PWM three-phase inverters, in which it is necessary to check the effects caused to the motor by the electromagnetic interference, (EMI) in the differential mode, as well as in the common mode. The motor parameters determination is generally performed in adequate laboratories using accurate instruments, such as very expensive RLC bridges. The method proposed here consists in the identification of the motor equivalent electrical circuit parameters in rated frequency and in high frequency through characteristic tests in the laboratory, together with the use of characteristic equations and curves, shown in the references to be mentioned for determining the motor high frequency parasite capacitances and also through system simulations using dedicated software, like Pspice, determining the characteristic waveforms involved in the differential and common mode phenomena, comparing and validating the procedure through published papers [01].

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To ensure high accuracy results from GPS relative positioning, the multipath effects have to be mitigated. Although the careful selection of antenna site and the use of especial antennas and receivers can minimize multipath, it cannot always be eliminated and frequently the residual multipath disturbance remains as the major error in GPS results. The high-frequency multipath from large delays can be attenuated by double difference (DD) denoising methods. But the low-frequency multipath from short delays is very difficult to be reduced or modeled. In this paper, it is proposed a method based on wavelet regression (WR), which can effectively detect and reduce the low-frequency multipath. The wavelet technique is firstly applied to decompose the DD residuals into the low-frequency bias and high-frequency noise components. The extracted bias components by WR are then directly applied to the DD observations to correct them from the trend. The remaining terms, largely characterized by the high-frequency measurement noise, are expected to give the best linear unbiased solutions from a least-squares (LS) adjustment. An experiment was carried out using objects placed close to the receiver antenna to cause, mainly, low-frequency multipath. The data were collected for two days to verify the multipath repeatability. The ground truth coordinates were computed with data collected in the absence of the reflector objects. The coordinates and ambiguity solution were compared with and without the multipath mitigation using WR. After mitigating the multipath, ambiguity resolution became more reliable and the coordinates were more accurate.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

the aim of this study was to validate the Alternate Current Biosusceptometry (ACB) for monitoring gastric contractions in rats. In vitro data were obtained to establish the relationship between ACB and the strain-gauge (SG) signal amplitude. In vivo experiments were performed on rats with magnetic markers and SGs previously implanted under the gastric serosa. The effects of the prandial state in gastric motility profiles were obtained. The correlation between in vitro signal amplitudes was strong (R = 0.989). The temporal cross-correlation between the ACB and SG signal amplitude was higher in the postprandial than in the fasting state. Irregular signal profiles, low contraction amplitudes, and smaller signal-to-noise ratios explained the poor correlation for fasting-state recordings. The contraction frequencies using ACB were 0.068 ± 0.007 Hz (postprandial) and 0.058 ± 0.007 Hz (fasting) and those using SG were 0.066 ± 0.006 Hz (postprandial) and 0.059 ± 0.008 Hz (fasting) (P < 0.003). When a magnetic tracer was ingested, there was a strong correlation and a small phasedifference between techniques. We conclude that ACB provides an accurate and sensitive technique for studies of GI motility in the rat. © 2010 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper presents a method for analyzing electromagnetic transients using real transformation matrices in three-phase systems considering the presence of ground wires. So, for the Z and Y matrices that represent the transmission line, the characteristics of ground wires are not implied in the values related to the phases. A first approach uses a real transformation matrix for the entire frequency range considered in this case. This transformation matrix is an approximation to the exact transformation matrix. For those elements related to the phases of the considered system, the transformation matrix is composed of the elements of Clarke's matrix. In part related to the ground wires, the elements of the transformation matrix must establish a relationship with the elements of the phases considering the establishment of a single homopolar reference in the mode domain. In the case of three-phase lines with the presence of two ground wires, it is unable to get the full diagonalization of the matrices Z and Y in the mode domain. This leads to the second proposal for the composition of real transformation matrix: obtain such transformation matrix from the multiplication of two real and constant matrices. In this case, the inclusion of a second matrix had the objective to minimize errors from the first proposal for the composition of the transformation matrix mentioned. © 2012 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O metilmercúrio (MeHg) é a forma mais tóxica do mercúrio. A exposição ao MeHg gera estresse oxidativo, podendo afetar a retina, pois esta possui alta vulnerabilidade em função do seu elevado conteúdo de ácidos graxos poliinsaturados e consumo de oxigênio. Nesse contexto, a administração de antioxidantes exógenos obtidos pela dieta, como os presentes na Euterpe oleracea (açaí), poderia ser uma forma de prevenir esse desequilíbrio e suas consequências. Portanto, o objetivo deste trabalho foi avaliar o possível efeito protetor da Euterpe oleracea nas alterações eletrofisiológicas causadas pelo MeHg na retina. Para tal, foi realizada gavagem com MeHgCl (5 mg/Kg) ou solução salina (NaCl 0,9%) durante 7 dias e pré-tratamento com ração enriquecida com polpa de açaí (10%) por 28 dias. Foram utilizados ratos Wistar divididos em 4 grupos: Grupo MeHg (recebeu ração padrão e MeHgCl); MeHg+Açaí (ração enriquecida com açaí e MeHgCl); Açaí (ração enriquecida com açaí e NaCl); Veículo (ração padrão e NaCl). Um dia após a última gavagem os animais foram submetidos ao eletrorretinograma de campo total (ffERG) para obtenção da resposta escotópica (de bastonetes, mista 1 e mista 2) e fotópica (de cones e de flicker em 12; 18; 24 e 30Hz). No dia seguinte ao ffERG foi aplicado o teste campo aberto para avaliar a atividade locomotora dos animais. Posteriormente, foi feita medição de peroxidação lipídica no tecido retiniano pelo método TBARS. A análise estatística foi feita pelo teste ANOVA de uma via com pós-teste de Tukey, considerando significativo p<0,05. Os resultados do campo aberto e da massa corporal não apresentaram diferença entre os grupos. O MeHg reduziu a amplitude das seguintes respostas: onda-b da resposta de bastonetes (Veículo: 114,6±23,6 μV e MeHg: 41,2±9,6 μV); onda-a (Veículo: 8,4±1,4 μV e MeHg: 3,4±0,3 μV) e onda-b (Veículo: 176,7±17,8 μV e MeHg: 69,5±12,0 μV) na resposta mista 1; onda-a (Veículo: 103,1 ±23,3 μV e MeHg: 40,2±9,6 μV) e onda-b (Veículo: 281±,38,3 μV e MeHg: 138,6±14 μV) da resposta mista 2; onda-a (Veículo: 27,2 ±3,6 μV e MeHg: 7,5±1,8 μV) e onda-b (Veículo: 139,3±16,1 μV e MeHg: 54,4±10 μV) da resposta de cones; onda-b nas frequências 12 Hz (Veículo: 67,7±10μV e MeHg: 28,6±6,9 μV), 18 Hz (Veículo: 31,3±3,4 μV e MeHg: 14,2± 2,3 μV) e 24 Hz (Veículo: 21,0±1,8μV e MeHg: 11,0± 1,1μV) e 30 Hz (Veículo: 10,9±0,6μV e MeHg: 6,0± 1,1μV). O tempo implícito das ondas não foi alterado em nem uma das respostas. O pré-tratamento com Euterpe oleracea evitou a redução de amplitude de ambas as ondas nas respostas mista 1 (onda-a: 8,3±0,6 μV; onda b: 144,1±7,1 μV) e mista 2 (onda-a: 106,4±13,6μV; onda b: 275,2±27,6 μV), assim como da onda-b da resposta de cones (104,5±5,9 μV) e fotópica de flicker em 12 Hz (67,2±9,1 μV), 18 Hz (29,5±4,8 μV) e 24 Hz (21,9±2,4 μV). A peroxidação lipídica no tecido retiniano do grupo MeHg (294,9±205,8%) foi maior que a do Veículo (100±25,1%) e o açaí protegeu contra esse dano oxidativo (MeHg+Açaí: 111,2±26,1%). Nossos resultados demonstraram alteração difusa na resposta eletrofisiológica e aumento na peroxidação lipídica da retina induzidos pelo MeHg e proteção exercida pelo açaí nesses dois parâmetros. Assim, a Euterpe oleracea poderia ser utilizada como importante alternativa para amenizar as alterações causadas pelo MeHg na retina.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neste trabalho é analisado o comportamento da densidade de corrente em cabos OPGW quando submetidos a descargas atmosféricas. Para esta análise, foram aplicados dois modelos de corrente, uma vez que a descarga atmosférica tem duas componentes principais que causam mais danos aos cabos em geral: a componente impulsiva e a componente contínua. O método numérico utilizado para as simulações computacionais é o método ADI-FDTD (Diferenças Finitas no Domínio do Tempo de Direções Alternadas Implícitas), o qual é truncado pela técnica CPML (Convolutional Perfectly Matched Layers). Com base no comportamento da corrente no cabo, é feita uma avaliação para determinar qual das duas componentes de descarga atmosférica pode causar mais danos aos cabos OPGW.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Implementações dos métodos de migração diferença finita e Fourier (FFD) usam fatoração direcional para acelerar a performance e economizar custo computacional. Entretanto essa técnica introduz anisotropia numérica que podem erroneamente posicionar os refletores em mergulho ao longo das direções em que o não foi aplicado a fatoração no operador de migração. Implementamos a migração FFD 3D, sem usar a técnica do fatoração direcional, no domínio da frequência usando aproximação de Padé complexa. Essa aproximação elimina a anisotropia numérica ao preço de maior custo computacional buscando a solução do campo de onda para um sistema linear de banda larga. Experimentos numéricos, tanto no modelo homogêneo e heterogêneo, mostram que a técnica da fatoração direcional produz notáveis erros de posicionamento dos refletores em meios com forte variação lateral de velocidade. Comparamos a performance de resolução do algoritmo de FFD usando o método iterativo gradiente biconjugado estabilizado (BICGSTAB) e o multifrontal massively parallel direct solver (MUMPS). Mostrando que a aproximação de Padé complexa é um eficiente precondicionador para o BICGSTAB, reduzindo o número de iterações em relação a aproximação de Padé real. O método iterativo BICGSTAB é mais eficiente que o método direto MUMPS, quando usamos apenas um termo da expansão de Padé complexa. Para maior ângulo de abertura do operador, mais termos da série são requeridos no operador de migração, e neste caso, a performance do método direto é mais eficiente. A validação do algoritmo e as propriedades da evolução computacional foram avaliadas para a resposta ao impulso do modelo de sal SEG/EAGE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Alkalinization potential is a fundamental property of endodontic epoxy-based cements containing calcium hydroxide. Studies have shown discrepant pH results for same materials at different evaluation periods. A possible reason accounting for these differences may be the assessment procedures. Objective: To evaluate the pH value of an epoxy-based cement (Sealer 26) in different periods of analysis, using two assessment methods. Material and methods: Sealer 26 was manipulated and immediately placed into polyethylene tubes (n=10, each group) and immersed in distilled water. In G1, the tubes were kept in the same water during all experiment; and in G2, the tubes were removed and placed into another flask with an equal amount of water after the pH evaluation. The pH of these solutions was measured at 24 hours, 7, 14 and 28 days. Analysis were made within the same group according to the experimental periods and between groups in each experimental period. Data were submitted to ANOVA (α = 5%) and t test, respectively. Results: For G1 and G2, all periods showed different pH values (p < 0.05), except between 14 and 28 days (p > 0.05) and between 7 and 14 days (p > 0.05), respectively. In each period, no significant differences were observed between the groups. Conclusion: The method to obtain the pH values in different experimental periods no interfered in the final results. However, difference was observed when the results were analyzed at same group.