745 resultados para Hydrogen Cluster
Resumo:
Microsatellites are important highly polymorphic genetic markers dispersed in the human genome. Using a panel of 22 (CA)n repeat microsatellite markers mapped to recurrent breakpoint cluster regions specifically involved in leukemia, we investigated 114 adult leukemias (25 acute lymphocytic leukemia [ALL], 32 acute myeloid leukemia [AML], 36 chronic lymphocytic leukemia [CLL], and 21 chronic myeloid leukemia [CML] in chronic phase) for somatic mutations at these loci. In each patient, DNA from fresh leukemia samples was analyzed alongside normal constitutive DNA from buccal epithelium. We detected loss of heterozygosity (LOH) in 81 of 114 patients (ALL 16/25, AML 25/32, CLL 30/36, CML 10/21). Deletions were most often seen in ALL at 11q23 and 19p13; in AML at 8q22 and 11q23; in CLL at 13q14.3, 11q13, and 11q23; and in CML at 3q26. Only six deletions were reported in 74 karyotypes analyzed, whereas in these same cases, 91 LOH events were detected by microsatellites. Of 26 leukemias with a normal karyotype, 16 nevertheless showed at least one LOH by microsatellite analysis. Replication errors were found in 10 of 114 patients (8.8%). Thus, microsatellite instability is rare in leukemia in contrast to many solid tumors. Our findings suggest that in adult leukemia, LOH may be an important genetic event in addition to typical chromosomal translocations. LOH may point to the existence of tumor suppressor genes involved in leukemogenesis to a degree that has hitherto been underestimated.
Resumo:
1.1 Fundamentals Chest pain is a common complaint in primary care patients (1 to 3% of all consultations) (1) and its aetiology can be miscellaneous, from harmless to potentially life threatening conditions. In primary care practice, the most prevalent aetiologies are: chest wall syndrome (43%), coronary heart disease (12%) and anxiety (7%) (2). In up to 20% of cases, potentially serious conditions as cardiac, respiratory or neoplasic diseases underlie chest pain. In this context, a large number of laboratory tests are run (42%) and over 16% of patients are referred to a specialist or hospitalized (2).¦A cardiovascular origin to chest pain can threaten patient's life and investigations run to exclude a serious condition can be expensive and involve a large number of exams or referral to specialist -‐ often without real clinical need. In emergency settings, up to 80% of chest pains in patients are due to cardiovascular events (3) and scoring methods have been developed to identify conditions such as coronary heart disease (HD) quickly and efficiently (4-‐6). In primary care, a cardiovascular origin is present in only about 12% of patients with chest pain (2) and general practitioners (GPs) need to exclude as safely as possible a potential serious condition underlying chest pain. A simple clinical prediction rule (CPR) like those available in emergency settings may therefore help GPs and spare time and extra investigations in ruling out CHD in primary care patients. Such a tool may also help GPs reassure patients with more common origin to chest pain.
Resumo:
L-2-amino-4-methoxy-trans-3-butenoic acid (AMB) is a potent antibiotic and toxin produced by Pseudomonas aeruginosa. Using a novel biochemical assay combined with site-directed mutagenesis in strain PAO1, we have identified a five-gene cluster specifying AMB biosynthesis, probably involving a thiotemplate mechanism. Overexpression of this cluster in strain PA7, a natural AMB-negative isolate, led to AMB overproduction.
Resumo:
A new species of Plebeia, the second largest genus of stingless bees in the Neotropical region, is described from eastern Brazil. Plebeia grapiuna sp. nov., known only from the lowland forests of southern Bahia, is most similar to P. lucii Moure, a species recently described from Minas Gerais. The lack of yellow marks and the smoother integument of the frons and mesoscutum in P. grapiuna sp. nov. distinguish them. Main features of the nesting habits of the new species are described and illustrated.
Resumo:
Positron emission tomography with [18F] fluorodeoxyglucose (FDG-PET) plays a well-established role in assisting early detection of frontotemporal lobar degeneration (FTLD). Here, we examined the impact of intensity normalization to different reference areas on accuracy of FDG-PET to discriminate between patients with mild FTLD and healthy elderly subjects. FDG-PET was conducted at two centers using different acquisition protocols: 41 FTLD patients and 42 controls were studied at center 1, 11 FTLD patients and 13 controls were studied at center 2. All PET images were intensity normalized to the cerebellum, primary sensorimotor cortex (SMC), cerebral global mean (CGM), and a reference cluster with most preserved FDG uptake in the aforementioned patients group of center 1. Metabolic deficits in the patient group at center 1 appeared 1.5, 3.6, and 4.6 times greater in spatial extent, when tracer uptake was normalized to the reference cluster rather than to the cerebellum, SMC, and CGM, respectively. Logistic regression analyses based on normalized values from FTLD-typical regions showed that at center 1, cerebellar, SMC, CGM, and cluster normalizations differentiated patients from controls with accuracies of 86%, 76%, 75% and 90%, respectively. A similar order of effects was found at center 2. Cluster normalization leads to a significant increase of statistical power in detecting early FTLD-associated metabolic deficits. The established FTLD-specific cluster can be used to improve detection of FTLD on a single case basis at independent centers - a decisive step towards early diagnosis and prediction of FTLD syndromes enabling specific therapies in the future.
Resumo:
Metodologia d'instal·lació d'un sistema operatiu i aplicacions orientada al seu ús en clusters de càlcul i enfocada principalment a la senzillesa de manteniment i a la compartició d'un màxim de programari entre equips.
Resumo:
In earlier work, the present authors have shown that hardness profiles are less dependent on the level of calculation than energy profiles for potential energy surfaces (PESs) having pathological behaviors. At variance with energy profiles, hardness profiles always show the correct number of stationary points. This characteristic has been used to indicate the existence of spurious stationary points on the PESs. In the present work, we apply this methodology to the hydrogen fluoride dimer, a classical difficult case for the density functional theory methods
Resumo:
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. However, hydrogen (H2) detection after a GC separation is only possible with a Thermal Conductivity Detector (TCD), a Helium Ionisation Detector (HID) or expensive Atomic Emission Detector (AED). Recently, indirect H2 detection by GC coupled to mass spectrometry (MS) was demonstrated but the mechanism of carrier gas protonation remained unclear. With electron impact as ionisation source of MS and helium (He) as GC carrier gas, H2 is not ionised according the expected Penning ionisation neither according to the Associative ionisation. Rearrangement ionisation (RI) was found to be the main channel for H2 and D2 ionisation under GC-MS conditions used in most of laboratories using GC-MS, leading to the formation of [He−H]+ and [He−D]+ ions.
Resumo:
A set of bottled waters from a single natural spring distributed worldwide in polyethylene terephthalate (PET) bottles has been used to examine the effects of storage in plastic polymer material on the isotopic composition (delta(18)O and delta(2)H values) of the water. All samples analyzed were subjected to the same packaging procedure but experienced different conditions of temperature and humidity during storage. Water sorption and the diffusive transfer of water and water vapor through the wall of the PET bottle may cause isotopic exchange between water within the bottle and water vapor in air near the PET-water interface. Changes of about +4 parts per thousand for delta(2)H and +0.7 parts per thousand for delta(18)O have been measured for water after 253 days of storage within the PET bottle. The results of this study clearly indicate the need to use glass bottles for storing water samples for isotopic studies. It is imperative to transfer PET-bottled natural waters to glass bottles for their use as calibration material or potential international working standards. Copyright (C) 2008 John Wiley & Sons, Ltd.
Resumo:
Carbon isotope ratio (CIR) analysis has been routinely and successfully used in sports drug testing for many years to uncover the misuse of endogenous steroids. One limitation of the method is the availability of steroid preparations exhibiting CIRs equal to endogenous steroids. To overcome this problem, hydrogen isotope ratios (HIR) of endogenous urinary steroids were investigated as a potential complement; results obtained from a reference population of 67 individuals are presented herein. An established sample preparation method was modified and improved to enable separate measurements of each analyte of interest where possible. From the fraction of glucuronidated steroids; pregnanediol, 16-androstenol, 11-ketoetiocholanolone, androsterone (A), etiocholanolone (E), dehydroepiandrosterone (D), 5α- and 5β-androstanediol, testosterone and epitestosterone were included. In addition, sulfate conjugates of A, E, D, epiandrosterone and 17α- and 17β-androstenediol were considered and analyzed after acidic solvolysis. The obtained results enabled the calculation of the first reference-population-based thresholds for HIR of urinary steroids that can readily be applied to routine doping control samples. Proof-of-concept was accomplished by investigating urine specimens collected after a single oral application of testosterone-undecanoate. The HIR of most testosterone metabolites were found to be significantly influenced by the exogenous steroid beyond the established threshold values. Additionally, one regular doping control sample with an extraordinary testosterone/epitestosterone ratio of 100 without suspicious CIR was subjected to the complementary methodology of HIR analysis. The HIR data eventually provided evidence for the exogenous origin of urinary testosterone metabolites. Despite further investigations on HIR being advisable to corroborate the presented reference-population-based thresholds, the developed method proved to be a new tool supporting modern sports drug testing procedures.
Resumo:
Spectroscopic and photometric observations in a 6 arcmin x 6 arcmin field centered on the rich cluster of galaxies Abell 2390 are presented. The photometry concerns 700 objects and the spectroscopy 72 objects. The redshift survey shows that the mean redshift of the cluster is 0.232. An original method for automatic determination of the spectral type of galaxies is presented.
Resumo:
We present new photometric and spectroscopic observations of objects in the field of the cluster of galaxies Abell 2218. The photometric survey, centered on the cluster core, extends to a field of about 4 x 4 arcmin. It was performed in 5 bands (B,g,r,i and z filters). This sample, which includes 729 objects, is about three times larger than the survey made by Butcher and collaborators (Butcher et al., 1983, Butcher and Oemler, 1984) in the same central region of the field. Only 228 objects appear in both catalogues since our survey covers a smaller region. The spectral range covered by our filters is wider and the photometry is much deeper, up to magnitude 27 in r. The spectroscopic survey concerns 66 objects, on a field comparable to that of Butcher and collaborators. From our observations we calculate the mean redshift of the cluster, 0.1756, and its velocity dispersion, 1370 km/s. The spectral types are determined for many galaxies in the sample by comparing their spectra with synthetic ones from Rocca-Volmerange and Guiderdoni (1988).
Resumo:
The aim of our study was to present a new headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable to the routine determination of hydrogen sulfide (H(2)S) concentrations in biological and gaseous samples. The primary analytical drawback of the GC/MS methods for H(2)S measurement discussed in the literature was the absence of a specific H(2)S internal standard required to perform quantification. Although a deuterated hydrogen sulfide (D(2)S) standard is currently available, this standard is not often used because this standard is expensive and is only available in the gas phase. As an alternative approach, D(2)S can be generated in situ by reacting deuterated chloride with sodium sulfide; however, this technique can lead to low recovery yield and potential isotopic fractionation. Therefore, N(2)O was chosen for use as an internal standard. This method allows precise measurements of H(2)S concentrations in biological and gaseous samples. Therefore, a full validation using accuracy profile based on the β-expectation tolerance interval is presented. Finally, this method was applied to quantify H(2)S in an actual case of H(2)S fatal intoxication.