777 resultados para Emergency-room


Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The objective of this study was to analyse the use of lights and siren (L&S) during transport to the hospital by the prehospital severity status of the patient and the time saved by the time of day of the mission. METHODS: We searched the Public Health Services data of a Swiss state from 1 January 2010 to 31 December 2010. All primary patient transports within the state were included (24 718). The data collected were on the use of L&S, patient demographics, the time and duration of transport, the type of mission (trauma vs. nontrauma) and the severity of the condition according to the National Advisory Committee for Aeronautics (NACA) score assigned by the paramedics and/or emergency physician. We excluded 212 transports because of missing data. RESULTS: A total of 24 506 ambulance transports met the inclusion criteria. L&S were used 4066 times, or in 16.6% of all missions. Of these, 40% were graded NACA less than 4. Overall, the mean total transport time to return to the hospital was 11.09 min (confidence interval 10.84-11.34) with L&S and 12.84 min (confidence interval 12.72-12.96) without. The difference was 1.75 min (105 s; P<0.001). For night-time runs alone, the mean time saved using L&S was 0.17 min (10.2 s; P=0.27). CONCLUSION: At present, the use of L&S seems questionable given the severity status or NACA score of transported patients. Our results should prompt the implementation of more specific regulations for L&S use during transport to the hospital, taking into consideration certain physiological criteria of the victim as well as time of day of transport.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Pediatric resuscitation is an intense, stressful, and challenging process. The aim of this study was to review the life-threatening pediatric (LTP) emergencies admitted in a Swiss university hospital with regards to patients' demographics, reason for admission, diagnosis, treatment, significant events, critical incidents, and outcomes. METHODS: A retrospective observational cohort study of prospectively collected data was conducted, including all LTP emergencies admitted over a period of 2 years in the resuscitation room (RR). Variables, including indication for transfer, mode of prehospital transportation, diagnosis, and time spent in RR, were recorded. RESULTS: Of the 60,939 pediatric emergencies treated in our university hospital over 2 years, a total of 277 LTP emergencies (0.46%) were admitted in the RR. They included 160 boys and 117 girls, aged 6 days to 15.95 years (mean, 6.69 years; median, 5.06). A medical problem was identified in 55.9% (n = 155) of the children. Of the 122 children treated for a surgical problem, 35 (28.3%) went directly from the RR to the operating room. Hemodynamic instability was noted in 19.5% of all LTP emergencies, of which 1.1% benefited from O negative transfusion. Admission to the intensive care unit was necessary for 61.6% of the children transferred from another hospital. The average time spent in the RR was 46 minutes. The overall mortality rate was 7.2%. CONCLUSIONS: The LTP emergencies accounted for a small proportion of all pediatric emergencies. They were more medical than surgical cases and resuscitation measures because of hemodynamic instability were the most frequent treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Paediatric resuscitation is an intense, stressful andchallenging process performed in a specific surrounding. In theresuscitation room (RR), a dedicated pediatric team is not alwaysavailable and its composition varies according to local resources. Aregular review of the children admitted in the resuscitation room andthe assessment of various outcome measures are the basis of qualitycontrol (QC). The epidemiology of Potentially Life ThreateningPaediatric (LTP) emergencies admitted in a Swiss university hospitalhas never been reported. The aims of this study were to review theLTP emergency population with regards to origin, patients'demographics, reason for admission and final diagnosis, treatmentmodalities, critical events and outcome.Methods: A retrospective observational cohort study of prospectivelycollected data was conducted, including all LTP emergencies admittedover a period of 2 years in the RR of a Swiss university hospitalfunctioning as a tertiary level referral centre. Multiple variablesincluding indication for transfer, mode of pre-hospital transportation,diagnosis and the time spent in RR were assessed. Data assessmenttook place 2 years after the implementation of a quality control (QC)team assessing the pediatric resuscitations occurring within theinstitution on a monthly basis.Results: Out of 60 939 pediatric emergencies treated in LausanneUniversity Medical center over 2 years, a total of 277 LTP emergencies(0.46%) were admitted to the RR, including 160 boys and 117 girls,aged 6 days to 15.95 years (mean 6.69 years, median 5.06). The tablebelow illustrates in more details the identified problems, average age,time in hospital and outcome of both surgical and medical groups ofpatients.Conclusions: With the need for health care quality improvement andfinancial restrictions, an excellent knowledge of the characteristics ofLTP emergencies is unavoidable. A thorough understanding of theresuscitation process and humans resources involved can be achievedwith a systematic review of the cases. A dedicated quality control teamevaluating LTP emergencies in a hospital will identify areas forimprovement. A LTP registry at the national level would be of greatvalue in Switzerland.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Sirens used by police, fire and paramedic vehicles have been designed so that they can be heard over large distances, but unfortunately the siren noise enters the vehicle and corrupts intelligibility of voice communications from the emergency vehicle to the control room. Often the siren needs to be turned off to enable the control room to hear what is being said. This paper discusses a siren noise filter system that is capable of removing the siren noise picked up by the two-way radio microphone inside the vehicle. The removal of the siren noise improves the response time for emergency vehicles and thus save lives. To date, the system has been trialed within a fire tender in a non-emergency situation, with good results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conference Room Paper, No 12

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Emergency departments (EDs) are an essential component of any developed health care system. There is, however, no national description of EDs in Switzerland. Our objective was to establish the number and location of EDs, patient visits and flow, medical staff and organization, and capabilities in 2006, as a benchmark before emergency medicine became a subspecialty in Switzerland. METHODS In 2007, we started to create an inventory of all hospital-based EDs with a preliminary list from the Swiss Society of Emergency and Rescue Medicine that was improved with input from ED physicians nationwide. EDs were eligible if they offered acute care 24 h per day, 7 days per week. Our goal was to have 2006 data from at least 80% of all EDs. The survey was initiated in 2007 and the 80% threshold reached in 2012. RESULTS In 2006, Switzerland had a total of 138 hospital-based EDs. The number of ED visits was 1.475 million visits or 20 visits per 100 inhabitants. The median number of visits was 8,806 per year; 25% of EDs admitted 5,000 patients or less, 31% 5,001-10,000 patients, 26% 10,001-20,000 patients, and 17% >20,000 patients per year. Crowding was reported by 84% of EDs with >20,000 visits/year. Residents with limited experience provided care for 77% of visits. Imaging was not immediately available for all patients: standard X-ray within 15 min (70%), non-contrast head CT scan within 15 min (38%), and focused sonography for trauma (70%); 67% of EDs had an intensive care unit within the hospital, and 87% had an operating room always available. CONCLUSIONS Swiss EDs were significant providers of health care in 2006. Crowding, physicians with limited experience, and the heterogeneity of emergency care capabilities were likely threats to the ubiquitous and consistent delivery of quality emergency care, particularly for time-sensitive conditions. Our survey establishes a benchmark to better understand future improvements in Swiss emergency care.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Bolt-kit systems are increasingly used as an alternative to conventional external cerebrospinal fluid (CSF) drainage systems. Since 2009 we regularly utilize bolt-kit external ventricular drainage (EVD) systems with silver-bearing catheters inserted manually with a hand drill and skull screws for emergency ventriculostomy. For non-emergency situations, we use conventional ventriculostomy with subcutaneous tunneled silver-bearing catheters, performed in the operating room with a pneumatic drill. This retrospective analysis compared the two techniques in terms of infection rates. METHODS 152 patients (aged 17-85 years, mean=55.4 years) were included in the final analysis; 95 received bolt-kit silver-bearing catheters and 57 received conventionally implanted silver-bearing catheters. The primary endpoint combined infection parameters: occurrence of positive CSF culture, colonization of catheter tips, or elevated CSF white blood cell counts (>4/μl). Secondary outcome parameters were presence of microorganisms in CSF or on catheter tips. Incidence of increased CSF cell counts and number of patients with catheter malposition were also compared. RESULTS The primary outcome, defined as analysis of combined infection parameters (occurrence of either positive CSF culture, colonization of the catheter tips or raised CSF white blood cell counts >4/μl)was not significantly different between the groups (58.9% bolt-kit group vs. 63.2% conventionally implanted group, p=0.61, chi-square-test). The bolt-kit group was non-inferior and not superior to the conventional group (relative risk reduction of 6.7%; 90% confidence interval: -19.9% to 25.6%). Secondary outcomes showed no statistically significant difference in the incidence of microorganisms in CSF (2.1% bolt-kit vs. 5.3% conventionally implanted; p=0.30; chi-square-test). CONCLUSIONS This analysis indicates that silver-bearing EVD catheters implanted with a bolt-kit system outside the operating room do not significantly elevate the risk of CSF infection as compared to conventional implant methods.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article describes the design, implementation, and experiences with AcMus, an open and integrated software platform for room acoustics research, which comprises tools for measurement, analysis, and simulation of rooms for music listening and production. Through use of affordable hardware, such as laptops, consumer audio interfaces and microphones, the software allows evaluation of relevant acoustical parameters with stable and consistent results, thus providing valuable information in the diagnosis of acoustical problems, as well as the possibility of simulating modifications in the room through analytical models. The system is open-source and based on a flexible and extensible Java plug-in framework, allowing for cross-platform portability, accessibility and experimentation, thus fostering collaboration of users, developers and researchers in the field of room acoustics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, electron paramagnetic resonance, photoluminescence (PL) emission, and quantum mechanical calculations were used to observe and understand the structural order-disorder of CaTiO(3), paying special attention to the role of oxygen vacancy. The PL phenomenon at room temperature of CaTiO(3) is directly influenced by the presence of oxygen vacancies that yield structural order-disorder. These oxygen vacancies bonded at Ti and/or Ca induce new electronic states inside the band gap. Ordered and disordered CaTiO(3) was obtained by the polymeric precursor method. (C) 2009 American Institute of Physics. [DOI: 10.1063/1.3190524]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indium tin oxide (ITO) thin films have been deposited on (100) Si substrates by RF magnetron sputtering from a compact target (90% In(2)O(3)-10% SnO(2) in weight) with 6 in. in diameter. In order to perform electromechanical characterizations of these films, strain gauges were fabricated. An experimental set-up based on bending beam theory was developed to determine the longitudinal piezoresistive coefficient (pi(1)) of the strain gauges fabricated. It has been confirmed that electrical resistance of the strain gauges decreases with load increases which results a negative gauge factor. A model based on the activation energy was used to explain the origin of this negative signal. The influence of the temperature on piezoresistive properties of ITO films was also evaluated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interior view showing fireplace and mezzanine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As seen from upper level of house.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Looking towards pool deck, Hanging Basket top right.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As seen from upper level of house.