336 resultados para DIAPHRAGM
Resumo:
Magnetization measurements were performed on CeCoIn5 at temperatures down to 20 mK and magnetic fields up to 17 T applied along different crystallographic orientations. For field configurations nearly parallel to the ab plane (theta less than or similar to 40 degrees and T <= 50 mK), we have found an intriguing vortex dynamics regime revealed by a hysteretic and metastable anomalous peak effect (APE), which gives evidence of surface barrier effects enhanced by antiferromagnetic fluctuations in the mixed state of CeCoIn5. Furthermore, we have observed crossover features in the torque and magnetization traces at fields below H-c2, which are consistent with vortices lattice phase transitions and with the anomalies speculated to be the Fulde-Ferrel-Larkin-Ovchinnikov (FFLO) superconducting state in CeCoIn5. All of the above features were found to be dramatically perturbed in Ce0.98Gd0.02CoIn5.
Resumo:
OBJECTIVE: The standard therapy for patients with high-level spinal cord injury is long-term mechanical ventilation through a tracheostomy. However, in some cases, this approach results in death or disability. The aim of this study is to highlight the anesthetics and perioperative aspects of patients undergoing insertion of a diaphragmatic pacemaker. METHODS: Five patients with quadriplegia following high cervical traumatic spinal cord injury and ventilator-dependent chronic respiratory failure were implanted with a laparoscopic diaphragmatic pacemaker after preoperative assessments of their phrenic nerve function and diaphragm contractility through transcutaneous nerve stimulation. ClinicalTrials.gov:NCT01385384. RESULTS: The diaphragmatic pacemaker placement was successful in all of the patients. Two patients presented with capnothorax during the perioperative period, which resolved without consequences. After six months, three patients achieved continuous use of the diaphragm pacing system, and one patient could be removed from mechanical ventilation for more than 4 hours per day. CONCLUSIONS: The implantation of a diaphragmatic phrenic system is a new and safe technique with potential to improve the quality of life of patients who are dependent on mechanical ventilation because of spinal cord injuries. Appropriate indication and adequate perioperative care are fundamental to achieving better results.
Resumo:
Duchenne muscular dystrophy (DMD) is a recessive X-linked form of muscular dystrophy characterized by progressive and irreversible degeneration of the muscles. The mdx mouse is the classical animal model for DMD, showing similar molecular and protein defects. The mdx mouse, however, does not show significant muscle weakness, and the diaphragm muscle is significantly more degenerated than skeletal muscles. In this work, magnetic resonance spectroscopy (MRS) was used to study the metabolic profile of quadriceps and diaphragm muscles from mdx and control mice. Using principal components analysis (PCA), the animals were separated into groups according to age and lineages. The classification was compared to histopathological analysis. Among the 24 metabolites identified from the nuclear MR spectra, only 19 were used by the PCA program for classification purposes. These can be important key biomarkers associated with the progression of degeneration in mdx muscles and with natural aging in control mice. Glutamate, glutamine, succinate, isoleucine, acetate, alanine and glycerol were increased in mdx samples as compared to control mice, in contrast to carnosine, taurine, glycine, methionine and creatine that were decreased. These results suggest that MRS associated with pattern recognition analysis can be a reliable tool to assess the degree of pathological and metabolic alterations in the dystrophic tissue, thereby affording the possibility of evaluation of beneficial effects of putative therapies. (C) 2012 Elsevier Inc. All rights reserved.
Resumo:
Yamaguti WP, Claudino RC, Neto AP, Chammas MC, Gomes AC, Salge TM, Moriya HT, Cukier A, Carvalho CR. Diaphragmatic breathing training program improves abdominal motion during natural breathing in patients with chronic obstructive pulmonary disease: a randomized controlled trial. Arch Phys Med Rehabil 2012;93:571-7. Objective: To investigate the effects of a diaphragmatic breathing training program (DBTP) on thoracoabdominal motion and functional capacity in patients with chronic obstructive pulmonary disease. Design: A prospective, randomized controlled trial. Setting: Academic medical center. Participants: Subjects (N=30; forced expiratory volume in Is, 4270 +/- 13% predicted) were randomly allocated to either a training group (TG) or a control group (CG). Interventions: Subjects in the TG completed a 4-week supervised DBTP (3 individualized weekly sessions), while those in the CG received their usual care. Main Outcome Measures: Effectiveness was assessed by amplitude of the rib cage to abdominal motion ratio (RC/ABD ratio) (primary outcome) and diaphragmatic mobility (secondary outcome). The RC/ABD ratio was measured using respiratory inductive plethysmography during voluntary diaphragmatic breathing and natural breathing. Diaphragmatic mobility was measured by ultrasonography. A 6-minute walk test and health-related quality of life were also evaluated. Results: Immediately after the 4-week DBTP, the TG showed a greater abdominal motion during natural breathing quantified by a reduction in the RC/ABD ratio when compared with the CG (F=8.66; P<.001). Abdominal motion during voluntary diaphragmatic breathing after the intervention was also greater in the TG than in the CG (F=4.11; P<.05). The TG showed greater diaphragmatic mobility after the 4-week DBTP than did the CG (F=15.08; P<.001). An improvement in the 6-minute walk test and in health-related quality of life was also observed in the TG. Conclusions: DBTP for patients with chronic obstructive pulmonary disease induced increased diaphragm participation during natural breathing, resulting in an improvement in functional capacity.
Resumo:
Chitosan/poly(vinyl sulfonic acid) (PVS) films have been prepared on Nafion® membranes by the layer-by-layer (LbL) method for use in direct methanol fuel cell (DMFC). Computational methods and Fourier transform infrared (FTIR) spectra suggest that an ionic pair is formed between the sulfonic group of PVS and the protonated amine group of chitosan, thereby promoting the growth of LbL films on the Nafion® membrane as well as partial blocking of methanol. Chronopotentiometry and potential linear scanning experiments have been carried out for investigation of methanol crossover through the Nafion® and chitosan/PVS/Nafion® membranes in a diaphragm diffusion cell. On the basis of electrical impedance measurements, the values of proton resistance of the Nafion® and chitosan/PVS/Nafion® membranes are close due to the small thickness of the LbL film. Thus, it is expected an improved DMFC performance once the additional resistance of the self-assembled film is negligible compared to the result associated with the decrease in the crossover effect.
Resumo:
OBJETIVO: Pacientes com lesão medular cervical alta em geral são dependentes de ventilação mecânica, que, embora salve vidas, está associada a complicações e redução da expectativa de vida devido a infecções respiratórias. A estimulação do diafragma por marca-passo, às vezes chamada de ventilação elétrica, induz a inspiração por estimulação dos músculos inspiratórios. Nosso objetivo foi destacar as indicações e alguns aspectos da técnica cirúrgica empregada no implante laparoscópico dos eletrodos, assim como descrever cinco casos de pacientes tetraplégicos submetidos à técnica. MÉTODOS: A seleção dos pacientes envolveu estudos de condução do nervo frênico por via transcutânea para determinar se os nervos estavam preservados. A abordagem cirúrgica foi laparoscopia clássica, com quatro trocartes. A técnica foi iniciada com o mapeamento elétrico para encontrar os "pontos motores" (pontos de contração máxima do diafragma). Se o mapeamento era bem-sucedido, dois eletrodos eram implantados na face abdominal de cada lado do diafragma para estimular ramos do nervo frênico. RESULTADOS: Dos cinco pacientes, três e um, respectivamente, eram capazes de respirar somente com o uso do marca-passo por períodos superiores a 24 e 6 h, enquanto um não era capaz. CONCLUSÕES: Embora seja necessário um acompanhamento mais longo para chegar a conclusões definitivas, os resultados iniciais são promissores, pois, no momento, a maioria dos nossos pacientes pode permanecer sem ventilação mecânica por longos períodos de tempo.
Resumo:
Abstract Introduction Biphasic positive airway pressure (BIVENT) is a partial support mode that employs pressure-controlled, time-cycled ventilation set at two levels of continuous positive airway pressure with unrestricted spontaneous breathing. BIVENT can modulate inspiratory effort by modifying the frequency of controlled breaths. Nevertheless, the optimal amount of inspiratory effort to improve respiratory function while minimizing ventilator-associated lung injury during partial ventilatory assistance has not been determined. Furthermore, it is unclear whether the effects of partial ventilatory support depend on acute lung injury (ALI) etiology. This study aimed to investigate the impact of spontaneous and time-cycled control breaths during BIVENT on the lung and diaphragm in experimental pulmonary (p) and extrapulmonary (exp) ALI. Methods This was a prospective, randomized, controlled experimental study of 60 adult male Wistar rats. Mild ALI was induced by Escherichia coli lipopolysaccharide either intratracheally (ALIp) or intraperitoneally (ALIexp). After 24 hours, animals were anesthetized and further randomized as follows: (1) pressure-controlled ventilation (PCV) with tidal volume (Vt) = 6 ml/kg, respiratory rate = 100 breaths/min, PEEP = 5 cmH2O, and inspiratory-to-expiratory ratio (I:E) = 1:2; or (2) BIVENT with three spontaneous and time-cycled control breath modes (100, 75, and 50 breaths/min). BIVENT was set with two levels of CPAP (Phigh = 10 cmH2O and Plow = 5 cmH2O). Inspiratory time was kept constant (Thigh = 0.3 s). Results BIVENT was associated with reduced markers of inflammation, apoptosis, fibrogenesis, and epithelial and endothelial cell damage in lung tissue in both ALI models when compared to PCV. The inspiratory effort during spontaneous breaths increased during BIVENT-50 in both ALI models. In ALIp, alveolar collapse was higher in BIVENT-100 than PCV, but decreased during BIVENT-50, and diaphragmatic injury was lower during BIVENT-50 compared to PCV and BIVENT-100. In ALIexp, alveolar collapse during BIVENT-100 and BIVENT-75 was comparable to PCV, while decreasing with BIVENT-50, and diaphragmatic injury increased during BIVENT-50. Conclusions In mild ALI, BIVENT had a lower biological impact on lung tissue compared to PCV. In contrast, the response of atelectasis and diaphragmatic injury to BIVENT differed according to the rate of spontaneous/controlled breaths and ALI etiology.
Resumo:
Rationale: NAVA is an assisted ventilatory mode that uses the electrical activity of the diaphragm (Edi) to trigger and cycle the ventilator, and to offer inspiratory assistance in proportion to patient effort. Since Edi varies from breath to breath, airway pressure and tidal volume also vary according to the patient's breathing pattern. Our objective was to compare the variability of NAVA with PSV in mechanically ventilated patients during the weaning phase. Methods: We analyzed the data collected for a clinical trial that compares PSV and NAVA during spontaneous breathing trials using PSV, with PS of 5 cmH2O, and NAVA, with Nava level titrated to generate a peak airway pressure equivalent to PSV of 5 cmH2O (NCT01137271). We captured flow, airway pressure and Edi at 100Hz from the ventilator using a dedicated software (Servo Tracker v2, Maquet, Sweden), and processed the cycles using a MatLab (Mathworks, USA) code. The code automatically detects the tidal volume (Vt), respiratory rate (RR), Edi and Airway pressure (Paw) on a breath-by-breath basis for each ventilatory mode. We also calculated the coefficient of variation (standard deviation, SD, divided by the mean). Results: We analyzed data from eleven patients. The mean Vt was similar on both modes (370 ±70 for Nava and 347± 77 for PSV), the RR was 26±6 for Nava and 26±7 or PSV. Paw was higher for Nava than for PSV (14±1 vs 11±0.4, p=0.0033), and Edi was similar for both modes (12±8 for Nava and 11±6 for PSV). The variability of the respiratory pattern, assessed with the coefficient of variation, was larger for Nava than for PSV for the Vt ( 23%±1% vs 15%±1%, p=0.03) and Paw (17%±1% vs 1% ±0.1%, p=0.0033), but not for RR (21% ±1% vs 16% ±8%, p=0.050) or Edi (33%±14% vs 39% ±16%,p=0.07). Conclusion: The variability of the breathing pattern is high during spontaneous breathing trials independent of the ventilatory mode. This variability results in variability of airway pressure and tidal volume, which are higher on Nava than on PSV. Our results suggest that Nava better reflects the normal variability of the breathing pattern during assisted mechanical ventilation.
Resumo:
This artwork reports on two different projects that were carried out during the three years of Doctor of the Philosophy course. In the first years a project regarding Capacitive Pressure Sensors Array for Aerodynamic Applications was developed in the Applied Aerodynamic research team of the Second Faculty of Engineering, University of Bologna, Forlì, Italy, and in collaboration with the ARCES laboratories of the same university. Capacitive pressure sensors were designed and fabricated, investigating theoretically and experimentally the sensor’s mechanical and electrical behaviours by means of finite elements method simulations and by means of wind tunnel tests. During the design phase, the sensor figures of merit are considered and evaluated for specific aerodynamic applications. The aim of this work is the production of low cost MEMS-alternative devices suitable for a sensor network to be implemented in air data system. The last two year was dedicated to a project regarding Wireless Pressure Sensor Network for Nautical Applications. Aim of the developed sensor network is to sense the weak pressure field acting on the sail plan of a full batten sail by means of instrumented battens, providing a real time differential pressure map over the entire sail surface. The wireless sensor network and the sensing unit were designed, fabricated and tested in the faculty laboratories. A static non-linear coupled mechanical-electrostatic simulation, has been developed to predict the pressure versus capacitance static characteristic suitable for the transduction process and to tune the geometry of the transducer to reach the required resolution, sensitivity and time response in the appropriate full scale pressure input A time dependent viscoelastic error model has been inferred and developed by means of experimental data in order to model, predict and reduce the inaccuracy bound due to the viscolelastic phenomena affecting the Mylar® polyester film used for the sensor diaphragm. The development of the two above mentioned subjects are strictly related but presently separately in this artwork.
Resumo:
Lung ultrasound use is increasing in respiratory medicine thanks to its development in the latest years. Actually it allows to study diseases of the chest wall (traumas, infections, neoplasms), diaphragm (paralysis, ipokinesis), pleura (effusions, pneumothorax, thickenings, neoplasms) and lung parenchyma (consolidations, interstitial syndromes, peripheral lesions). One of the most useful application of chest ultrasound is the evaluation of effusions. However, no standardized approach for ultrasound-guided thoracenthesis is available. Our study showed that our usual ultrasonographic landmark (“V-point”) could be a standard site to perform thoracenthesis: in 45 thoracenthesis no pneumothorax occurred, drainage was always successful at first attempt. Values of maximum thickness at V-point and drained fluid volume showed a significative correlation. Proteins concentration of ultrasound patterns of effusions (anechoic, ipoechoic, moving echoic spots, dense moving spots, hyperechoic) were compared to those of the macroscopic features of fluids showing connection between light-yellow fluid and echoic moving spots pattern and between ipoechoic/dense moving spots and cloudy-yellow/serum-haematic fluids. These observations suggest that ultrasound could predict chemical-physical features of effusions. Lung ultrasound provides useful information about many disease of the lung, but actually there is not useful in obstructive bronchial diseases. Analysing diaphragmatic kinetics using M-mode through transhepatic scan we described a similarity between diaphragm excursion during an expiratory forced maneuver and the volume/time curve of spirometry. This allowed us to identify the M-mode Index of Obstruction (MIO), an ultrasound-analogue of FEV1/VC. We observed MIO values of normal subjects (9) and obstructed patients (9) comparing the two groups. FEV1/VC and MIO showed a significant correlation suggesting that MIO may be affected by airways obstruction; MIO values were significatively different between normal and obstructed so that it could identify an obstructive syndrome. The data show that it is possible to suspect the presence of obstructive syndrome of the airways using ultrasonography of the diaphragm.
Resumo:
The aim of this study was to investigate the influence of the diaphragm flexibility on the behavior of out-of-plane walls in masonry buildings. Simplified models have been developed to perform kinematic and dynamic analyses in order to compare the response of walls with different restraint conditions. Kinematic non linear analyses of assemblages of rigid blocks have been performed to obtain the acceleration-displacement curves for walls with different restraint conditions at the top. A simplified 2DOF model has been developed to analyse the dynamic response of the wall with an elastic spring at the top, following the Housner rigid behaviour hypothesis. The dissipation of energy is concentrated at every impact at the base of the wall and is modelled through the introduction of the coefficient of restitution. The sets of equations of the possible configurations of the wall, depending on the different positions of the centre of rotation at the base and at the intermediate hinge have been obtained. An algorithm for the numerical integration of the sets of the equations of motion in the time domain has been developed. Dynamic analyses of a set of walls with Gaussian impulses and recorded accelerograms inputs have been performed in order to compare the response of the simply supported wall with the one of the wall with elastic spring at the top. The influence of diaphragm stiffness Kd has been investigated determining the variation of maximum displacement demand with the value of Kd. A more regular trend has been obtained for the Gaussian input than for the recorded accelerograms.
Resumo:
Obbiettivo. Analizzare la funzionalità polmonare e diaframmatica dopo interventi di plicatura del diaframma con rete di rinforzo peri-costale eseguiti per relaxatio e riparazione di ernia transdiaframmatica cronica mediante riduzione e sutura diretta. Metodi. Dal 1996 al 2010, 10 pazienti con relaxatio unilaterale del diaframma e 6 pazienti con ernia transdiaframmatica cronica misconosciuta sono stati sottoposti a chirurgia elettiva. Gli accertamenti preoperatori e al follow-up di 12 mesi includevano prove di funzionalità respiratoria, misura della pressione massimale inspiratoria alla bocca in clino e ortostatismo, emogasanlisi, TC del torace e dispnea score. Risultati. I pazienti dei due gruppi non differivano in termini di funzionalità respiratoria preoperatoria nè di complicanze postoperatorie; al follow-up a 12 mesi il gruppo Eventrazione mostrava un significativo aumento del FEV1% (+18,2 – p<0.001), FVC% (+12,8 – p<0.001), DLCO% (+6,84 – p=0,04) e pO2 (+9,8 mmHg – p<0.001). Al contrario nrl gruppo Ernia solo il miglioramento della pO2 era significativo (+8.3 – p=0.04). Sebbene la massima pressione inspiratoria (PImax) fosse aumentata in entrambi i gruppi al follow-up, i pazienti operati per ernia mostravano un miglioramento limitato con persistente caduta significativa della PImax dall’ortostatismo al clinostatismo (p<0.001). Il Transitional dyspnoea score è stato concordante con tali miglioramenti pur senza differenze significative tra i due gruppi. La TC del torace ha evidenziato una sopraelevazione dell’emidiaframma suturato, senza recidiva di ernia, mentre i pazienti sottoposti a plicatura hanno mantenuto l’ipercorrezione. Conclusioni. L’utilizzo di un rinforzo protesico è sicuro e sembra assicurare risultati funzionali migliori a distanza in termini di flussi respiratori e di movimento paradosso del diaframma (valutato mediante PImax). Lacerazioni estese del diaframma coinvolgenti le branche principali di suddivisione del nervo frenico si associano verosimilmente a una relaxatio che può quindi ridurre il guadagno funzionale a lungo termine se non adeguatamente trattata mediante l’utilizzo di un rinforzo protesico.
Resumo:
Rhogocytes, also termed ‘pore cells’, exist free in the hemolymph or embedded in the connective tissue of different body parts of molluscs, notably gastropods. These unique cells can be round, elongated or irregularly shaped, and up to 30 μm in diameter. Their hallmark is the so-called slit apparatus: i.e. pocket-like invaginations of the plasma membrane creating extracellular lacunae, bridged by cytoplasmic bars. These bars form distinctive slits of ca. 20 nm width. A slit diaphragm composed of proteins establishes a molecular sieve with holes of 20 x 20 nm. Different functions have been assigned to this special molluscan cell type, notably biosynthesis of the hemolymph respiratory protein hemocyanin. It has further been proposed, but not proven, that in the case of red-blooded snail species rhogocytes might synthesize the hemoglobin. However, the secretion pathway of these hemolymph proteins, and the functional role of the enigmatic slit apparatus remained unclear. Additionally proposed functions of rhogocytes, such as heavy metal detoxification or hemolymph protein degradation, are also not well studied. This work provides more detailed electron microscopical, histological and immunobiochemical information on the structure and function of rhogocytes of the freshwater snails Biomphalaria glabrata and Lymnaea stagnalis. By in situ hybridization on mantle tissues, it proves that B. glabrata rhogocytes synthesize hemoglobin and L. stagnalis rhogocytes synthesize hemocyanin. Hemocyanin is present, in endoplasmic reticulum lacunae and in vesicles, as individual molecules or pseudo-crystalline arrays. The first 3D reconstructions of rhogocytes are provided by means of electron tomography and show unprecedented details of the slit apparatus. A highly dense material in the cytoplasmic bars close to the diaphragmatic slits was shown, by immunogold labeling, to contain actin. By immunofluorescence microscopy, the protein nephrin was localized at the periphery of rhogocytes. The presence of both proteins in the slit apparatus supports the previous hypothesis, hitherto solely based on similarities of the ultrastructure, that the molluscan rhogocytes are phylogenetically related to mammalian podocytes and insect nephrocytes. A possible secretion pathway of respiratory proteins that includes a transfer mechanism of vesicles through the diaphragmatic slits is proposed and discussed. We also studied, by electron microscopy, the reaction of rhogocytes in situ to two forms of animal stress: deprivation of food and cadmium contamination of the tank water. Significant cellular reactions to both stressors were observed and documented. Notably, the slit apparatus surface and the number of electron-dense cytoplasmic vesicles increased in response to cadmium stress. Food deprivation led to an increase in hemocyanin production. These observations are also discussed in the framework of using such animals as potential environmental biomarkers.
Resumo:
FGFRL1 (fibroblast growth factor receptor like 1) is the fifth and most recently discovered member of the fibroblast growth factor receptor (FGFR) family. With up to 50% amino acid similarity, its extracellular domain closely resembles that of the four conventional FGFRs. Its intracellular domain, however, lacks the split tyrosine kinase domain needed for FGF-mediated signal transduction. During embryogenesis of the mouse, FGFRL1 is essential for the development of parts of the skeleton, the diaphragm muscle, the heart, and the metanephric kidney. Since its discovery, it has been hypothesized that FGFRL1 might act as a decoy receptor for FGF ligands. Here we present several lines of evidence that support this notion. We demonstrate that the FGFRL1 ectodomain is shed from the cell membrane of differentiating C2C12 myoblasts and from HEK293 cells by an as yet unidentified protease, which cuts the receptor in the membrane-proximal region. As determined by ligand dot blot analysis, cell-based binding assays, and surface plasmon resonance analysis, the soluble FGFRL1 ectodomain as well as the membrane-bound receptor are capable of binding to some FGF ligands with high affinity, including FGF2, FGF3, FGF4, FGF8, FGF10, and FGF22. We furthermore show that ectopic expression of FGFRL1 in Xenopus embryos antagonizes FGFR signaling during early development. Taken together, our data provide strong evidence that FGFRL1 is indeed a decoy receptor for FGFs.
Resumo:
Neurally adjusted ventilatory assist (NAVA) delivers airway pressure (Paw) in proportion to neural inspiratory drive as reflected by electrical activity of the diaphragm (EAdi). Changing positive end-expiratory pressure (PEEP) impacts respiratory muscle load and function and, hence, EAdi. We aimed to evaluate how PEEP affects the breathing pattern and neuroventilatory efficiency during NAVA.